Free reference · 7 brands · Checked November 2026

Water heater error codes, in plain words

Pick your brand and type the code. You’ll see what it means, what you can safely check yourself, and what needs a pro. Every answer comes from the maker’s own manual, and we show you which one.

  • 889 codes
  • 277 maker documents
  • Every line sourced
Dan and Dave of Dan's Plumbing in front of their work truck

From Dan and Dave at Dan's Plumbing, a family plumbing shop in Westlake Village, California. Water heaters are most of what we do. We install Noritz and Bradford White and work on all of these.

Find your code

Status light blinking on a tank? Pick the brand and type the number of blinks.

Most looked up

Smell gas? Don’t touch any switch or try to reset anything. Leave the house, then call 911 or your gas company from outside. In Southern California that’s SoCalGas, 1-800-427-2200.

By brand

Pick your water heater’s brand

Same number, different brand

Code 11 on a Rinnai isn’t always code 11 on a Noritz

Several tankless makers use the same two-digit numbers, and many of them line up. Some don’t. Here’s each number side by side, straight from each maker’s manual. Open the table and tap one for the details.

Show all 49 codes side by side
CodeRinnaiNoritzRheemBradford White
03Power went out while the bath-fill feature was running.Not usedOnly on two or more heaters linked together.Not used
05The valve that mixes cold water into the hot side (the bypass valve) is not working right.This is a maintenance reminder, not a breakdown.Warning: the heat exchanger is reading colder than it should while the heater runs.Not used
07On the RH180 hybrid, not enough water is moving through the internal circulation loop.Not usedWiFi models: water saving mode is limiting how much water flows.Not used
10The heater cannot move enough air in or exhaust out.An early warning that air or gas flow is not right.Not enough air is moving through the heater.The flame went out 8 times.
11Water is flowing and the heater tried to light, but the burner never lit.The heater tried to light but did not see a flame.The heater tried to light but did not sense a flame.The burner failed to light 10 times.
12The burner lit, but the flame went out or the heater could not sense it.The heater lit, but then lost the flame while running (a weak flame).The flame lit, then went out, three times in a row.Not used
13On the RH180 hybrid, combustion is not right.An optional carbon monoxide (CO) alarm wired to the heater went off, or its wire is broken.Earlier indoor models: the second flame sensor sees poor burning, usually from low gas supply or a venting problem.Not used
14The heat exchanger got too hot and a safety switch shut the heater down.The heat exchanger got far too hot and a one-time safety fuse burned open.The overheat safety limit has tripped or broken.Not used
15The part that mixes air and gas (the venturi on the gas valve) is not responding correctly.The water going into the main heat exchanger is hotter than it should be.Water inside the heater got hotter than 207°F for over 15 seconds.Not used
16The hot water leaving the heater got too hot, so the heater shut itself off for safety.The hot water leaving the heater got too hot, so the heater shut off and slowed the water flow for safety.The hot water leaving the heater is hotter than the temperature set on the display.Water in the heat exchanger or outlet went over 199 F.
17The air/gas venturi is blocked by debris, so the heater cannot mix air and gas right.Not usedWiFi models: the leak sensor inside the heater found water.Not used
20Not usedA safety switch on the heat exchanger tripped because the water got near boiling.Not usedThe high-limit overheat switch opened.
21After a control board swap, the settings did not copy over to the new board correctly.A safety switch on the burner box tripped because that area got too hot.Not usedNot used
29Not usedOn condensing models, the acidic water (condensate) the heater makes cannot drain out.Condensing models: acidic condensate water is not draining out of the heater’s built-in trap.Condensate is not draining, or the exhaust is blocked.
30On the RH180 hybrid, the flammable vapor sensor has a fault or sensed vapors.The air temperature sensor inside the heater is open, shorted or unplugged.Not usedNot used
31The burner temperature sensor (thermocouple) is reading too high or too low, or has failed.The incoming (cold) water temperature sensor is open, shorted or unplugged.The cold-water inlet temperature sensor has failed or is reading wrong.The cold-water inlet sensor reads open or shorted.
32The sensor that reads the hot water leaving the heater is bad, unplugged, or coated with scale.The hot water outlet temperature sensor is open, shorted or unplugged.The heat exchanger temperature sensor has failed or is reading wrong.The hot water outlet sensor reads open or shorted.
33The temperature sensor on the heat exchanger outlet is bad, unplugged, or coated with scale.The heat exchanger temperature sensor is open, shorted or unplugged.The hot-water outlet temperature sensor has failed or is reading wrong.The heat exchanger temperature sensor reads open or shorted.
34The sensor that reads the temperature of the incoming combustion air (in the fan housing) is bad, or the air/burner is running too hot.The sensor that watches for scale on the heat exchanger fell off or is open, shorted or unplugged.The air (ambient) temperature sensor has failed or is reading wrong.Not used
35On the RH180 hybrid, the storage-tank temperature sensor is bad or unplugged.The exhaust temperature sensor is open, shorted or unplugged.One of the temperature sensors is loose or plugged into the wrong spot.The exhaust temperature sensor reads open or shorted.
38The sensor that reads exhaust temperature is bad or unplugged, or exhaust conditions are wrong.On NRCP models, the circuit board has a memory error.Not usedNot used
39Not usedOn NRCP models, the heater still sees a flame after the gas valve closed.Not usedThe flame sensor still sees flame (or outside light) after the burner shut off.
40Not usedOn NRCP models, a gas sensor inside the heater detected gas.Not usedThe heater’s built-in gas leak detection tripped.
41The outside-air sensor used for freeze protection is open, shorted or unplugged.On a multi-unit NCC199CDV system, a second or later heater cannot sense water flow, so it cannot run.Not usedThe fan is running too fast while firing, often from a vent problem.
42Not usedOn NRCR models, the recirculation flow sensor is not working, so recirculation mode cannot stay stable.Not usedThe air pressure switch opened, often from a blocked exhaust.
43Not usedOn NRCP models, a safety switch at the burner tripped.Not usedThe burner overheat switch opened.
44Not usedOn NRCP models, the built-in recirculation pump or loop is not working right.Not usedGR only: the built-in recirculation pump may have failed.
45Not usedOn NRCP models, a leak sensor in the bottom of the heater got wet.Not usedThe built-in leak detector found water; the heater closed its cold-water inlet valve to limit damage.
46Not usedOn NRCP111/NRCP98, the recirculation flow is too low.Not usedGR only: not enough flow in the recirculation loop.
51The sensor that reads incoming cold water temperature is bad, dirty or unplugged.A gas valve inside the heater is not working or not connected.Flame is still sensed a few seconds after the heater shut off.Not used
52The gas valve or its venturi assembly is not working right on a SENSEI, RX or CX heater.Not usedThe proportional (modulating) gas valve that adjusts the flame size is not working right.Not used
60Not usedOn NRCP models, the hot water got too hot (over 167°F at normal settings).Not usedGR only: hot water temperature is abnormal.
61The fan that pushes air through the burner is not running right.The combustion fan is not turning at the right speed, or the heater cannot read its speed.The combustion fan is not spinning at the right speed.The fan speed signal is wrong or the fan is not turning.
63The recirculation pump loop is not moving enough water.On NRCR models, the built-in recirculation pump is not moving water.Recirculation models: the built-in pump is not running at the right speed.Not used
65The valve that controls water flow through the heater failed.The motor valve that controls water flow through the heater is not working or not connected.The motorized water valve that limits how much water flows through the heater is not working.The water supply (flow control) valve has a fault.
66The bypass (mixing) valve servo is not working right.The bypass water valve that mixes cold water into the hot is not working or not connected.The bypass valve, which blends cold water in to control the outlet temperature, is not working.The internal mixing valve has a fault.
67Not usedOn NRCP models, the air-gas mixer motor is stuck or not wired right.Not usedThe AGM (air/gas mixing) part at the fan inlet has a fault.
70The main control board has a fault or a setting/plug problem.The main circuit board has a fault.The control board’s computer chip is not working.Not used
71A gas valve solenoid circuit has a fault, or the PC board’s gas-valve DIP switch is on.The circuit board cannot run the gas valve correctly.The gas valve’s shut-off solenoid circuit has a problem.Not used
72The flame sensor (flame rod) is not reading the flame correctly.The heater sees a flame when there should not be one.The flame sensor sees flame before the igniter even sparks.The flame sensor sees flame or light before ignition.
73The burner temperature sensor circuit has a wiring or sensor fault.The circuit board settings do not match (gas type, vent, DIP switches), or a plug or switch was changed with power on.Not usedThe DIP switch settings do not match the heater.
76Not usedOn display-window models, the unit’s own display is not talking to the circuit board.The display or remote cannot talk to the heater’s control board.The main control and the display panel are not talking.
78Not usedOn NRCP models, two linked heaters are not talking.Not usedCascaded (linked) heaters only: units lost communication.
79The leak sensor found water in the bottom of the heater cabinet.On NRCR models, the part of the board that runs the pump failed.The fan motor is drawing the wrong amount of electrical current.Not used
90Not usedThe fuel-and-air mix is off, so the heater shut down.The heater found a blocked vent before lighting.Not used
92Not usedThe built-in condensate neutralizer is near the end of its life.Earlier condensing models: the condensate neutralizer needs to be replaced soon.Not used
93Not usedThe built-in condensate neutralizer is used up.Earlier condensing models: the heater will not run until the condensate neutralizer is replaced.Not used
94Not usedOn a condensing heater, the exhaust is hotter than it should be.Not usedExhaust temperature is too high.
99Not usedA serious combustion problem.The heater found a blocked vent after it shut off (during the fan’s post-purge).Not used

“Not used” means the code isn’t in any of that maker’s documents we read. Takagi uses three-digit codes and Navien uses codes that start with E, so they have their own pages.

Tank water heaters

Status light blinking? Count the blinks

Many gas tank heaters, including Bradford White, Rheem and A.O. Smith, have a gas control with a small status light near the knob. Count the blinks between pauses. The count is the code. The same count means different things on each brand and each kind of tank, so look yours up below.

Bradford White

All 51 Bradford White light codes, including power vent →

Rheem

All 27 Rheem light codes, including power vent →

A.O. Smith

All 60 A.O. Smith light codes, including power vent →

The gas control at the bottom of a tank water heater, with its status light. Below it, the light's pattern: 4 blinks, then a pause, over and over. STATUS LIGHT PAUSE · REPEAT
The light blinks a set number of times, pauses, then repeats. Count from one pause to the next.

Before you call anyone

The safe checks the manuals keep coming back to

  1. Is the gas on?

    Look at the gas shutoff on the pipe going into the heater. The handle should line up with the pipe. If the stove or other gas appliances don’t work either, call your gas company.

  2. Is the water on?

    The valves on the heater’s water pipes should be open. A tankless needs a minimum flow to light, so open a hot tap all the way when you test it.

  3. Is the power on?

    A tankless heater, and a power-vent tank, needs electricity. Check the plug, the breaker and any GFCI outlet it’s on.

  4. Look at the vent and air intake outside

    Leaves, a bird’s nest, a bush, a cover or a stack of boxes can block them. Clear anything you can reach from outside without taking pipes apart.

  5. Condensing tankless? Check the drain hose

    Its small drain hose carries water out of the heater. A kinked, clogged or frozen hose stops the heater.

  6. Reset it once

    Turn the heater off and back on, the way the maker says on its page here. If the code comes back, stop. That’s the heater telling you it needs service.

Leave these to a pro

  • Don’t open the burner, the gas valve or the sealed combustion chamber.
  • Don’t keep resetting a code that keeps coming back. A code that returns means the cause is still there.
  • Don’t bypass or unplug a safety sensor to get hot water back.
  • Don’t cover, tape or move the vent or the air intake.

Each code’s own page says which of these that maker’s manual lists for that code, with the page number.

Common questions

Water heater error code questions

What does a water heater error code mean?

It’s the heater telling you which safety check failed, like no flame, a blocked vent, low water flow or a bad sensor. The heater shuts the burner off and shows the code so the problem can be found quickly. The number means something different on each brand, so look it up by brand.

Can I reset a water heater error code myself?

Often, yes. Depending on the brand, you press a reset or back button, turn the heater off and on, or simply turn off the hot water so the heater stops. Each brand’s page here has its maker’s steps. If the same code comes back, stop resetting it. Something is still wrong and needs a technician.

Why does the light on my water heater’s gas valve blink?

On many newer gas tank heaters the gas control has a status light. On Rheem and A.O. Smith tanks, one blink every 3 seconds means it’s working. A set number of blinks, then a pause, is a code. Count the blinks and look up your brand, because the same count can mean different things on different tanks.

Is it safe to use hot water while the heater shows an error?

Most codes simply stop the burner, so you won’t get hot water but nothing is unsafe. If you smell gas, see water on the floor, or the code is about the vent or exhaust, turn the heater off and call for service.

Does an error code mean I need a new water heater?

Not usually. Many codes come from things around the heater, like a closed valve, a blocked vent, a dirty filter or scale. Age and leaks matter more. A tank that leaks from the tank itself does need replacing.

How we built this

Where every answer comes from

We started with the codes people search for most, from Google’s own search data, and then read the makers’ documents for each brand: owner’s manuals, installation manuals, service manuals and troubleshooting guides.

Every meaning, cause and step on these pages comes from those documents, and each one shows the document and page it came from. Where two models use the same code for different things, we say which model each meaning belongs to. If we only found a code on a forum and not in a maker’s document, we left it out.

We split each fix into what an owner can safely check without tools or opening the heater, and what needs a licensed technician. Gas valves, burners and the inside of the cabinet are always a technician’s job.

Spotted a mistake, or have a manual we should add? Tell us. You’re welcome to link to any of these pages.

Water heater help

More about water heaters

Dan standing in front of his white work truck, smiling

Code won’t clear?

If you’re within about 30 miles of Westlake Village, call or text Dan a photo of the display and the label. He’ll tell you what it is.

Or send the details and Dan will call you back. Monday to Friday, 9am – 5pm.

Find us

Dan's Plumbing

2352 Hillsbury Rd
Westlake Village, CA 91361

(805) 330-3111 · Monday to Friday, 9am – 5pm

Serving Westlake Village, Thousand Oaks, Agoura Hills, Oak Park and Lake Sherwood. Zip codes 91361, 91362, 91360, 91320, 91301, 91377, 91302, 90265.

Dan (left) and Dave. Family run since 1977. One of them does the work.