Noritz · Error code 29 · Checked November 2026
Noritz error code 29: a condensate drain problem
On most condensing models, the condensate drain line is clogged, frozen or not sloped down. On a few models, 29 means something else.
Smell gas? Don’t touch any switch or try to reset anything. Leave the house, then call 911 or your gas company from outside. In Southern California that’s SoCalGas, 1-800-427-2200.
From Dan and Dave at Dan's Plumbing, a family plumbing shop in Westlake Village, California. We install Noritz heaters. Everything below comes from Noritz’s own documents, cited line by line.
What it means
What Noritz says code 29 means
“Clogging of condensate trap or drain pipe”— Owner’s Guide - Condensing Tankless Gas Water Heater, Models NRC111DV (GQ-C3257WX-FF US) / NRC111OD (GQ-C3257WX US), page 28
On most Noritz condensing heaters, code 29 means the condensate can’t drain out. Condensate is the acidic water a condensing heater makes, and it leaves through a small drain line. If that line is clogged, frozen or doesn’t slope down, the heater stops.
The number means something else on some models. On current EZ (GQ-61) heaters, 29 only shows when an outside condensate pump is wired in and that pump is blocked or unplugged. On 2008–2011 NRC111 and NCC199 heaters it’s the built-in neutralizer. On NRCP heaters it’s the air pressure switch.
Model differences. Condensing units only. NRC1111/NCC1991 (2012): "Condensate drain trap abnormality". Different meanings on other families: GQ-61 = external condensate pump; 2009 NRC111/NCC199 = neutralizer; NRCP = air pressure switch. Not listed for non-condensing NR662/NR501/NER66.
On other Noritz models, 29 means something else:
- External Condensate Pump abnormalityOn current GQ-61 models, 29 only shows when an outside condensate pump is wired to the heater. On: GQ-61 (2023 on): EZ111DV, EZ98DV, EZ71DV, NRCR, NCC199CDV.
- Clogging of neutralizer (Neutralizer Water Level Electrode abnormality)On 2008-2011 NRC111 and NCC199 heaters with a built-in neutralizer, the neutralizer or its drain is clogged. On: 2008–2011 series: NRC111, NCC199, NR50 to NR111.
- Air Pressure Switch AbnormalityOn NRCP models, a pressure switch found the exhaust or air path blocked. On: NRCP with built-in recirculation.
Why it happens
Likely causes of Noritz code 29
- Condensate drain line clogged or frozen; drain pipe not sloped down. (GQ-57 service manual (2018), p. 35)
- Drain line smaller than 1/2 inch, not plastic, extra traps added, or run outside where it freezes. (Noritz Help Center: 29)
- 2012 NRC98/NRC83: condensate trap clogging - drain line clogged or frozen. NRC1111/NCC1991: condensate drain trap or drain pipe blocked, or water level electrode not connected. (Service manual (2012), pp. 40-41)
- Display-window condensing models: condensate container clogging - drain line clogged or frozen. (Service manual (2013), p. 28)
What to do
Safe checks first. Then call a pro.
Safe checks you can do
Check whether the condensate drain pipe is clogged or frozen. Call the installer or Noritz Technical Support for help. (NRC111 GQ-57 owner’s guide (2017), p. 28; NRC661 owner’s guide (2013), p. 25)
2012 condensing: check whether the condensate drain pipe is clogged or frozen; call the installer or Noritz. (NRC1111 owner’s guide (2013), p. 27)
Commercial NCC199DV / NCC300: same check. (NCC300 owner’s guide (2017), p. 42)
Thermalux NERC98DV / NERC11DV: same check; owner’s guide gives the Thermalux customer care number. (NERC98 owner’s guide (2019), p. 28)
To clear the code:
- Press the power button to turn the unit off, open a hot water tap, and turn the unit back on. If the flashing number does not return, the problem is solved. (NRC111 GQ-57 owner’s guide (2017), p. 28)
- Unplug the unit from power or press the power button on the optional remote to turn it off, open a hot water tap, and turn the unit back on. (NRC661 owner’s guide (2013), p. 25)
What a technician checks, and why
- Check the drain trap and drain line for blockage and slope; check the water level electrode connection (maintenance monitor No. 19 should read OFF/000).Opens the cabinet / needs meters or service mode (GQ-57 service manual (2018), pp. 35, 40-41)
- Check the drain line is at least 1/2 inch, plastic, short, sloped toward the drain, with no extra traps, and protected from freezing.Drain piping changes are plumbing work (Noritz Help Center: 29)
- 2012: check the neutralizer / drain-trap water level electrode with maintenance monitor 19 (000 = normal, 001 = abnormal).Opens the cabinet / needs meters or service mode (Service manual (2012), p. 41)
Please don’t
- Don’t open the burner, the gas valve or the sealed combustion chamber.
- Don’t keep resetting a code that keeps coming back. A code that returns means the cause is still there.
- Don’t bypass or unplug a safety sensor to get hot water back.
- Don’t cover, tape or move the vent or the air intake.
Heater getting old, or the same code keeps coming back? Repair or replace? Three taps and Dan’s answer → Or see what a water heater repair usually involves.
Common questions
Noritz code 29 questions
Can I clear a clogged Noritz condensate line myself?
You can check whether the end of the drain line is clogged or frozen. Noritz’s GQ-61 owner’s guide says that if water doesn’t come out of the end of the drain line, a qualified service technician must clean the condensate line.
Where this comes from
Sources
Taken from Noritz’s own documents, checked November 13, 2026. Page numbers are the printed page. Where models differ, we say which model each part applies to.
- Owner’s Guide - Condensing Tankless Gas Water Heater, Models NRC111DV (GQ-C3257WX-FF US) / NRC111OD (GQ-C3257WX US) Noritz America · Rev. 01/17 · Models: NRC111DV (GQ-C3257WX-FF US), NRC111OD (GQ-C3257WX US)
- Service Manual - Gas Water Heater: GQ-2457WS(-FFA) US [NR83], GQ-C2857WS(-FF) US [NRC98], GQ-C3257WX(-FF) US [NRC111], GQ-C3257WZ(-FF) US [NCC199], GQ-2857WX(-FFA,-F) US [NR98], GQ-2857WZ(-FFA) US [NC199] Noritz America · Rev: March, 2018 · Models: NR83 (-DVC,-OD), NRC98 (-DV,-OD), NRC111 (-DV,-OD), NCC199 (-DV,-OD), NR98 (-DVC,-OD,-SV), NC199 (-DVC,-OD)
- Noritz Help Center: Error Code 29 Noritz America · modified 2022-03-04 · Models: high efficiency condensing units
- Service Manual - Gas Water Heater: NRC83 (-DV,-OD), NRC98 (-DV,-OD), NRC1111/NCC1991 (-DV,-OD), NR981/NC1991 (-DVC,-OD,-SV), NR83-DVC Noritz America · Rev: October, 2012 · Models: NRC83, NRC98, NRC1111, NCC1991, NR981, NC1991, NR83-DVC
- Service Manual - Gas Water Heater: NR501-OD, NR662-OD, NRC661 (-DV,-OD), NRC711 (-DV,-OD) Noritz America · Rev: Dec, 2013 · Models: NR501-OD, NR662-OD, NRC661-DV/-OD, NRC711-DV/-OD
- Owner’s Guide - Condensing Tankless Gas Water Heater, Models NRC661-DV / NRC661-OD Noritz America · Rev. 01/13 · Models: NRC661-DV, NRC661-OD
- Owner’s Guide - Condensing Tankless Gas Water Heater, Models NRC1111-DV / NRC1111-OD Noritz America · Rev. 03/13 · Models: NRC1111-DV, NRC1111-OD
- Owner’s Guide - Condensing Tankless Gas Water Heater, Models NCC300DV (GQ-C5032WZ-FF US) / NCC300OD (GQ-C5032WZ US) Noritz America · Rev. 08/17 · Models: NCC300DV (GQ-C5032WZ-FF US), NCC300OD (GQ-C5032WZ US)