Rheem · Error code 11 · Checked November 2026
Rheem tankless error code 11: no flame detected
The heater tried to light and never sensed a flame. Start with the gas shut-off valve: it has to be fully open.
Smell gas? Don’t touch any switch or try to reset anything. Leave the house, then call 911 or your gas company from outside. In Southern California that’s SoCalGas, 1-800-427-2200.
From Dan and Dave at Dan's Plumbing, a family plumbing shop in Westlake Village, California. Everything below comes from Rheem’s own documents, cited line by line.
What it means
What Rheem says code 11 means
“the water heater will attempt ignition 2 times. If no flame is detected, the water heater displays the “11” error code”— High and Super High Efficiency Tankless Water Heater Troubleshooting Manual, page 37
Rheem’s manuals call code 11 “flame not detected by flame rod.” The heater tried to light and never sensed a flame. Current “-3” models try twice before showing 11. The Ruud RUTG and RUTGH are covered by the same manuals, so it means the same thing on a Ruud.
Rheem’s owner’s manual names one cause: the gas shut-off valve isn’t fully open. Its troubleshooting manual adds gas pressure, a blocked gas filter, the vent, and the igniter and flame rods.
Rheem’s newer IKONIC heaters show A011 for the same problem, after 10 tries.
Model differences. '-3' models try ignition 2 times before showing 11 (AP21822 p. 37). Earlier indoor models have 2 flame rods (SVC 820P p. 43). IKONIC equivalent is A011 (10 attempts).
Why it happens
Likely causes of Rheem code 11
- The gas shut-off valve is not fully opened. (AP21820 condensing tankless manual, p. 75; AP22009 RTG tankless manual, p. 77)
- Gas supply pressure, blocked gas filter, venting, igniter rod or flame rod. (AP21822 tankless troubleshooting manual, p. 37)
- Commonly gas supply and/or venting; also gas control valve (earlier platform). (SVC 820P tankless service manual, p. 41)
What to do
Safe checks first. Then call a pro.
Safe checks you can do
Check the gas shut-off valve and open it completely. (AP21820 condensing tankless manual, p. 75)
Look at the vent termination outside for blockage. (AP21822 tankless troubleshooting manual, p. 37)
To clear the code:
- Owner reset for a displayed code: turn off all hot taps; turn the heater off with POWER ON/OFF; wait about 5 minutes and turn it back on; open a hot tap and recheck. If the code is still there: turn off the tap and heater, unplug the heater for about 30 seconds, plug back in, follow the code chart, and recheck. If it still shows, write down the code and call for service. (AP21820 condensing tankless manual, p. 74)
- Same owner reset steps (turn off, wait about 5 minutes, restart; then unplug about 30 seconds) in the 2012 Use and Care manuals. (AP15897 condensing tankless manual (2012), p. 25)
What a technician checks, and why
- Check static and dynamic gas pressure at the heater’s gas connection (NG 4.0-10.5 in. W.C., LP 8.0-13.0 in. W.C.).Static and dynamic gas pressure are measured with a manometer at the heater’s gas connection (NG 4.0-10.5 in. W.C., LP 8.0-13.0 in. W.C.). (AP21822 tankless troubleshooting manual, p. 37)
- Clean the gas filter at the gas connection.Requires removing the front cover and testing or replacing internal parts (control board, sensors, valves, connectors) with a meter; the troubleshooting manual is written for qualified technicians only. (AP21822 tankless troubleshooting manual, p. 37)
- Check DIP switches for venting and altitude.Venting connections, terminations and vent-length/altitude DIP settings are installer work. (AP21822 tankless troubleshooting manual, p. 37)
- No spark: reseat igniter connectors; 108-132 VAC on connector O while igniting; clean or replace igniter rod and coil.Requires removing the front cover and testing or replacing internal parts (control board, sensors, valves, connectors) with a meter; the troubleshooting manual is written for qualified technicians only. (AP21822 tankless troubleshooting manual, p. 38)
- Spark but no flame signal: check flame rod status (0Y), clean or replace the flame rod; test gas valve solenoids (10-50 ohms, 5-15 VDC; inlet solenoid 11-17 VDC); replace gas valve or control board.Requires removing the front cover and testing or replacing internal parts (control board, sensors, valves, connectors) with a meter; the troubleshooting manual is written for qualified technicians only. (AP21822 tankless troubleshooting manual, p. 39)
Please don’t
- Don’t open the burner, the gas valve or the sealed combustion chamber.
- Don’t keep resetting a code that keeps coming back. A code that returns means the cause is still there.
- Don’t bypass or unplug a safety sensor to get hot water back.
- Don’t cover, tape or move the vent or the air intake.
Heater getting old, or the same code keeps coming back? Repair or replace? Three taps and Dan’s answer → Or see what a water heater repair usually involves.
Common questions
Rheem code 11 questions
How do I reset a Rheem tankless after code 11?
Turn off all hot taps, turn the heater off with the power button, wait about 5 minutes and turn it back on, then open a hot tap. If 11 is still there, unplug the heater for about 30 seconds and try again. If it still shows, write down the code and call for service. That’s Rheem’s own reset, from its owner’s manual.
Is code 11 the same on a Ruud tankless?
Yes. The Ruud RUTG and RUTGH are covered by the same Rheem manuals, and 11 means the flame wasn’t detected.
Where this comes from
Sources
Taken from Rheem’s own documents, checked November 13, 2026. Page numbers are the printed page. Where models differ, we say which model each part applies to.
- High and Super High Efficiency Tankless Water Heater Troubleshooting Manual Rheem Manufacturing Company, Water Heater Division · AP21822 · Rev 02 (Copyright 2025) · Models: RTGH-68/84/90/95 DV(E)L(N/P)-3, RUTGH-..-3, ECOH160/180/200..-3, RMTGH..-3, RTG-70/84/95 DV(E)L / X(E)L (N/P)-3, RUTG-..-3, ECO160/180/200..-3, RMTG..-3
- Super High Efficiency Condensing Tankless Water Heater Use and Care Manual With Installation Instructions for the Installer Rheem Manufacturing Company · AP21820 · Rev 06 (PDF dated Jan 2024) · Models: RTGH-95DVELN-3, RTGH-68/84/90/95DVL-3
- High-Efficiency Non-Condensing Tankless Water Heater Use and Care Manual With Installation Instructions for the Installer Rheem Manufacturing Company · AP22009 · Rev 06 (PDF dated Jan 2024) · Models: RTG-95DVLN-3, RTG-70/84/95 (DV/X)-3
- Tankless Gas Troubleshooting Pocket Manual SVC 820P - For Non-Condensing & Condensing Platforms Rheem Manufacturing Company · SVC-820P · REV 3 (printed 05/19) · Models: Non-condensing 64DV/X, 70DV/X, 84DV/X, 95DV/X, 150DV/X, 160DV/X, 180DV/X, 200DV/X, 2-20R, 2-25R, 2-28R, Condensing (up to -2 models) H-68, H-84, H-90, H-95, H-160, H-180, H-200, H-25R, H-32R
Water heater help
More about water heaters
Code won’t clear?
If you’re within about 30 miles of Westlake Village, call or text Dan a photo of the display and the label. He’ll tell you what it is.
Or send the details and Dan will call you back. Monday to Friday, 9am – 5pm.