Noritz error code 11: ignition failure

The heater tried to light and never saw a flame. Most often the gas is off, the gas pressure is low, or there’s no spark.

Smell gas? Don’t touch any switch or try to reset anything. Leave the house, then call 911 or your gas company from outside. In Southern California that’s SoCalGas, 1-800-427-2200.

Dan and Dave of Dan's Plumbing in front of their work truck

From Dan and Dave at Dan's Plumbing, a family plumbing shop in Westlake Village, California. We install Noritz heaters. Everything below comes from Noritz’s own documents, cited line by line.

What it means

What Noritz says code 11 means

“Ignition failure (Initial flame fault detection)”— Service Manual - Condensing Tankless Gas Water Heater (EZ111DV, EZ98DV, EZ71DV, NRCR111DV, NRCR92DV, NCC199CDV), page 45

Noritz calls code 11 an “ignition failure.” The heater tried to light and never saw a flame. Most often the gas is off, the gas pressure is low, or there’s no spark.

Noritz’s Help Center points outside the heater too: the gas meter, the regulator, the gas line and shut-off valves, and in earthquake areas like California, an earthquake safety shut-off valve. Gas pressure can also drop when other gas appliances run at the same time.

After a heater has been drained or shut off for a long time, Noritz says 11 can show from air in the gas line, and that it isn’t a malfunction.

Model differences. NRCP shows Er:11 only after 10 failed ignitions and it is a hard lockout (Power button off/on). After draining or a long shutdown, 11 (and 41 on GQ-61) can appear and is not a malfunction (GQ-61 OG p. 25; older OGs say the same). Display-window units show 11 on both the window and the remote.

Why it happens

Likely causes of Noritz code 11

What to do

Safe checks first. Then call a pro.

Safe checks you can do

  1. Check that the gas valve is open. Close the hot water tap and open it again; the heater tries again. You can also turn the POWER button off and on. If the number stops blinking, the problem is solved. (GQ-61 owner’s guide (2025), p. 31)

  2. If the heater stops while running: are the gas and water valves fully open, is the water supply on, and do other gas appliances (like the stove) work? With propane, is there gas in the tank? (GQ-61 owner’s guide (2025), p. 31)

  3. If the heater tries to light but fails: reset it and try again (there may be air in the gas line). Have a professional check the gas supply pressure. (GQ-61 owner’s guide (2025), p. 28)

  4. Check that the gas valve is open. Press the power button to turn the unit off, open a hot water tap, and turn the unit back on. If the number does not come back, the problem is solved. (NRC111 GQ-57 owner’s guide (2017), p. 28)

  5. Display-window models: unplug the unit or press the power button on the remote, open a hot tap, and turn the unit back on. (NRC661 owner’s guide (2013), p. 25)

  6. NRCP: press the Power button to clear Er:11, make sure the gas valve is fully open; if it happens again call the installer or Noritz. (NRCP111/NRCP98 owner’s guide (2019), p. 34)

  7. GQ-60 EZ: check that the gas valve is open; press the button to turn the heater off, open a hot water tap, and turn the heater back on. (GQ-60 owner’s guide (2021), p. 18)

  8. GQ-59 EZ: same reset as the remote-controller models (power off, open a hot tap, power on). (GQ-59 owner’s guide (2021), p. 28)

  9. 2008-2011 and 2005 models: check the gas valve is open; press the power button off, open a hot tap, turn it back on. (NR111 owner’s guide (2009), p. 25)

  10. 2002 models: check the gas valve is open; turn off the operation button, open a hot tap, and turn the operation button on again. (N-042 owner’s guide, p. 23)

  11. NRCB combi boiler: check the gas valve is open; power off, open a hot tap, power on. (NRCB owner’s guide (2021), p. 36)

To clear the code:

  • Ignition-type codes: close the hot water tap and open it again; the heater resumes. The code can also be cleared by turning the POWER button / Power switch off and on. (GQ-61 owner’s guide (2025), p. 31)
  • Press the button to turn the water heater off, open a hot water tap, and turn the water heater back on. If the blinking number does not return, the problem is solved. (GQ-60 owner’s guide (2021), p. 18)
  • Press the power button to turn the unit off, open a hot water tap, and turn the unit back on. If the flashing number does not return, the problem is solved. (NRC111 GQ-57 owner’s guide (2017), p. 28)
  • Unplug the unit from power or press the power button on the optional remote to turn it off, open a hot water tap, and turn the unit back on. (NRC661 owner’s guide (2013), p. 25)

What a technician checks, and why

  • Check gas supply piping and pressure at full fire, igniter spark, gas valve, flame rod, and the ground connection to the circuit board.Gas pressure and gas-valve work need a qualified service technician (GQ-61 service manual (2026), pp. 45, 70)
  • Check the gas meter, regulator, shut-off valves and any earthquake shut-off valve upstream of the heater.Noritz says gas troubleshooting should be left to a professional (Noritz Help Center: 11)
  • Look through the burner sight glass: no flame = check spark and gas; brief flame then 11 = clean/inspect the flame rod and check ground wires.Burner and ignition-rod work opens the combustion chamber (Noritz Help Center: 11)
  • GQ-57: check igniter output (DC 14-16 V), gas solenoid valve resistance (19-31 Ω primary, 36-58 Ω valve 1), proportioning valve (50-80 Ω), flame rod current (1 µA or more), ground wire, and manifold pressure.Gas pressure and gas-valve work need a qualified service technician (GQ-57 service manual (2018), p. 40)
  • NRCP: make sure gas supply and inlet gas pressure are within spec; check spark through the burner window.Gas pressure and gas-valve work need a qualified service technician (NRCP111/NRCP98 service manual (2019), p. 62)
  • NRCP: check the flame detector sensor line and connector; replace the flame sensor or the flame observation glass and gasket depending on voltage.Burner-area parts (NRCP1112/NRCP982 service manual (2019), p. 59)
  • 2008-2011: check gas supply piping and pressure, igniter spark, gas solenoid valves, flame rod and ground.Gas pressure and gas-valve work need a qualified service technician (Service manual (2011), p. 55)
  • NRCB: check gas piping and pressure, igniter spark, gas valve, flame rod and ground to the board.Gas pressure and gas-valve work need a qualified service technician (NRCB service manual (2020), p. 18)
  • Noritz training lists inlet gas pressure ranges for units up to 199k Btu: NG 4-10.5 in. WC, LP 8-14 in. WC (GQ-61 service manual gives NG 3.5-10.5, LP 8-13 for that platform).Gas pressure and gas-valve work need a qualified service technician (Noritz Level 2 training (2024), p. 6)

Please don’t

  • Don’t open the burner, the gas valve or the sealed combustion chamber.
  • Don’t keep resetting a code that keeps coming back. A code that returns means the cause is still there.
  • Don’t bypass or unplug a safety sensor to get hot water back.
  • Don’t cover, tape or move the vent or the air intake.

Heater getting old, or the same code keeps coming back? Repair or replace? Three taps and Dan’s answer → Or see what a water heater repair usually involves.

Common questions

Noritz code 11 questions

Can an earthquake shut-off valve cause Noritz code 11?

Yes. Noritz’s Help Center lists an earthquake safety shut-off valve among the things outside the heater that cause 11. If the stove and other gas appliances are out too, call your gas company or a plumber to reset it.

How do I clear Noritz code 11?

Make sure the gas valve is open. Then close the hot water tap and open it again so the heater tries again, or turn the power button off and on. If 11 keeps coming back, have the gas supply pressure checked.

Where this comes from

Sources

Taken from Noritz’s own documents, checked November 13, 2026. Page numbers are the printed page. Where models differ, we say which model each part applies to.

  1. Service Manual - Condensing Tankless Gas Water Heater (EZ111DV, EZ98DV, EZ71DV, NRCR111DV, NRCR92DV, NCC199CDV) Noritz America · Rev. 3/26 · Models: EZ111DV (GQ-C3261WX-FF(-1) US), EZ98DV (GQ-C2861WX-FF(-1) US), EZ71DV (GQ-C2661WX-FF(-1) US), NRCR111DV (GQ-C3261WXQ-FF(-1) US), NRCR92DV (GQ-C2661WXQ-FF(-1) US), NCC199CDV (GQ-C3261WZ-FF(-1) US)
  2. Owner’s Guide - Condensing Tankless Gas Water Heater (EZ111DV/EZ98DV/EZ71DV, NRCR111DV/NRCR92DV, GQ-C**61...-1) Noritz America · SBB81M1 · Rev. 10/25 · Models: EZ111DV (GQ-C3261WX-FF-1 US), EZ98DV (GQ-C2861WX-FF-1 US), EZ71DV (GQ-C2661WX-FF-1 US), NRCR111DV (GQ-C3261WXQ-FF-1 US), NRCR92DV (GQ-C2661WXQ-FF-1 US)
  3. Noritz Help Center: Error Code 11 Noritz America · modified 2026-10-20 · Models: general
  4. Service Manual - Gas Water Heater: GQ-2457WS(-FFA) US [NR83], GQ-C2857WS(-FF) US [NRC98], GQ-C3257WX(-FF) US [NRC111], GQ-C3257WZ(-FF) US [NCC199], GQ-2857WX(-FFA,-F) US [NR98], GQ-2857WZ(-FFA) US [NC199] Noritz America · Rev: March, 2018 · Models: NR83 (-DVC,-OD), NRC98 (-DV,-OD), NRC111 (-DV,-OD), NCC199 (-DV,-OD), NR98 (-DVC,-OD,-SV), NC199 (-DVC,-OD)
  5. Service Manual - Condensing Tankless Gas Water Heater, Models NRCP1112-DV / NRCP982-DV (Eco TOUGH) Noritz America · Rev.05/19 · Models: NRCP1112-DV, NRCP982-DV
  6. Service Manual - Gas Water Heater: NR50-OD; NR66/N-0531S; NR71/N-0631S; NR98/NC199/N-0751M; NCC199/N-0841MC; NRC111/N-0842MC; NR111/NC250/N-0931M; NC380/N-1321M-ASME Noritz America · Rev: July, 2011 · Models: NR50-OD, NR66, NR71, NR98, NC199, NCC199, NRC111, NR111, NC250-ASME, NC380-ASME, N-0531S, N-0631S, N-0751M, N-0841MC, N-0842MC, N-0931M, N-1321M-ASME
  7. Owner’s Guide - Condensing Tankless Gas Water Heater, Models NRC111DV (GQ-C3257WX-FF US) / NRC111OD (GQ-C3257WX US) Noritz America · Rev. 01/17 · Models: NRC111DV (GQ-C3257WX-FF US), NRC111OD (GQ-C3257WX US)
  8. Owner’s Guide - Condensing Tankless Gas Water Heater, Models NRC661-DV / NRC661-OD Noritz America · Rev. 01/13 · Models: NRC661-DV, NRC661-OD
  9. Owner’s Guide - Condensing Tankless Gas Water Heater, Models NRCP111-DV / NRCP98-DV Noritz America · Rev.05/19 · Models: NRCP111-DV, NRCP98-DV
  10. Owner’s Guide - Condensing Tankless Gas Water Heater, EZ111DV (GQ-C3260WX-FF US), EZ98DV (GQ-C2860WX-FF US) Noritz America · SBB8163-2 · Rev. 04/21 · Models: EZ111DV (GQ-C3260WX-FF US), EZ98DV (GQ-C2860WX-FF US)
  11. Owner’s Guide - Condensing Tankless Gas Water Heater, EZ111DV (GQ-C3259WX-FF US), EZ98DV (GQ-C2859WX-FF US) Noritz America · Rev. 04/21 · Models: EZ111DV (GQ-C3259WX-FF US), EZ98DV (GQ-C2859WX-FF US)
  12. Owner’s Guide - Tankless Gas Water Heater, Models NR111-SV / NR111-OD / NR111-DV Noritz America · Rev. 09/09 · Models: NR111-SV, NR111-OD, NR111-DV
  13. Owner’s Manual and Installation Guide and Warranty Registration Card - Model N-042 Noritz America · not printed · Models: N-042
  14. Owner’s Guide - Condensing Gas Combi Boiler, Model NRCB199DV (GHQ-C3201WX-FF US) Noritz America · Rev. 04/21 · Models: NRCB199DV (GHQ-C3201WX-FF US)
  15. Service Manual - Condensing Tankless Gas Water Heater, Models NRCP111-DV / NRCP98-DV Noritz America · Rev.09/19 · Models: NRCP111-DV, NRCP98-DV
  16. Service Manual - Condensing Gas-Fired Combination Boiler NRCB199DV (GHQ-C3201WX-FF US) / NRCB180DV (GHQ-C2801WX-FF US) Noritz America · Rev: September 2020 (cover also shows 2022) · Models: NRCB199DV, NRCB180DV
  17. Residential Level 2 - Maintenance and Troubleshooting (training printable) Noritz America · PDF dated 2024-08-28 · Models: residential tankless (general)

Water heater help

More about water heaters

Dan standing in front of his white work truck, smiling

Code won’t clear?

If you’re within about 30 miles of Westlake Village, call or text Dan a photo of the display and the label. He’ll tell you what it is.

Or send the details and Dan will call you back. Monday to Friday, 9am – 5pm.

Find us

Dan's Plumbing

2352 Hillsbury Rd
Westlake Village, CA 91361

(805) 330-3111 · Monday to Friday, 9am – 5pm

Serving Westlake Village, Thousand Oaks, Agoura Hills, Oak Park and Lake Sherwood. Zip codes 91361, 91362, 91360, 91320, 91301, 91377, 91302, 90265.

Dan (left) and Dave. Family run since 1977. One of them does the work.