Noritz · Error code 12 · Checked November 2026
Noritz error code 12: the flame went out
The heater lit, then lost the flame while it was running. Usually the flame was weak, from low gas or a vent problem.
Smell gas? Don’t touch any switch or try to reset anything. Leave the house, then call 911 or your gas company from outside. In Southern California that’s SoCalGas, 1-800-427-2200.
From Dan and Dave at Dan's Plumbing, a family plumbing shop in Westlake Village, California. We install Noritz heaters. Everything below comes from Noritz’s own documents, cited line by line.
What it means
What Noritz says code 12 means
“Flame Rod does not detect flame (Flame fault detection)”— Service Manual - Condensing Tankless Gas Water Heater (EZ111DV, EZ98DV, EZ71DV, NRCR111DV, NRCR92DV, NCC199CDV), page 45
Noritz calls code 12 “flame rod does not detect flame.” The heater lit, then lost the flame while it was running, usually because the flame was weak.
Noritz lists not enough gas to stay lit, a vent problem such as a direct-vent air intake pulling in exhaust, the wrong vent type on concentric-vent models, and the flame rod or its ground wire inside the heater. NRCP models show 12 after the flame is lost 8 times in a row.
Model differences. Sub-codes 12-1/12-2 on GQ-61 and 121/122 on display-window units. NRCP shows Er12 (Flame Loss) after flame loss 8 times in a row (NRCP SM p. 60).
Why it happens
Likely causes of Noritz code 12
- Flame went out, abnormal combustion, gas valve, flame rod, poor ground, or exhaust gas leaking inside the unit or vent pipe. (GQ-61 service manual (2026), p. 45)
- Not enough gas to stay lit; improper venting, for example a direct-vent air intake drawing in exhaust; the wrong vent type on DVC concentric models. (Noritz Help Center: 12)
- GQ-57: flame rod or its ground, gas solenoid valves, or gas supply / manifold pressure abnormality. (GQ-57 service manual (2018), p. 41)
- NRCP: flame lost 8 times in a row during combustion. (NRCP1112/NRCP982 service manual (2019), p. 60)
- 2008-2011: flame went out, abnormal combustion, gas solenoid valves, flame rod, ground. (Service manual (2011), pp. 54-56)
What to do
Safe checks first. Then call a pro.
Safe checks you can do
NRCP: make sure the main gas supply valve is fully open, and clean the intake air filter (owner’s guide shows how). (NRCP1112/NRCP982 service manual (2019), p. 58)
NRCP owner’s guide: clean the air intake filter monthly (remove the filter screw, wash with a toothbrush, dry, reinstall). (NRCP111/NRCP98 owner’s guide (2019), p. 30)
If the heater stops while running: are the gas and water valves fully open, is the water supply on, and do other gas appliances (like the stove) work? With propane, is there gas in the tank? (GQ-61 owner’s guide (2025), p. 31)
Look at the outside vent ends for blockage or for another appliance’s exhaust right next to the air intake, and tell your installer. (Noritz Help Center: 12)
To clear the code:
- Ignition-type codes: close the hot water tap and open it again; the heater resumes. The code can also be cleared by turning the POWER button / Power switch off and on. (GQ-61 owner’s guide (2025), p. 31)
- Press the button to turn the water heater off, open a hot water tap, and turn the water heater back on. If the blinking number does not return, the problem is solved. (GQ-60 owner’s guide (2021), p. 18)
- Press the power button to turn the unit off, open a hot water tap, and turn the unit back on. If the flashing number does not return, the problem is solved. (NRC111 GQ-57 owner’s guide (2017), p. 28)
- Unplug the unit from power or press the power button on the optional remote to turn it off, open a hot water tap, and turn the unit back on. (NRC661 owner’s guide (2013), p. 25)
What a technician checks, and why
- Check for flame loss and abnormal combustion; check gas valve, flame rod and ground on the circuit board; check for exhaust leaks inside the unit and at the vent.Opens the cabinet / needs meters or service mode (GQ-61 service manual (2026), p. 45)
- NRCP: check or change the burner window by removing the flame sensor.Opens the burner area (NRCP111/NRCP98 service manual (2019), p. 62)
- GQ-57: visually confirm flame, check flame rod wiring and current (1 µA or more), ground wire, gas solenoid valves (36-58 Ω), and manifold pressure.Gas pressure and gas-valve work need a qualified service technician (GQ-57 service manual (2018), p. 41)
- 2008-2011: check for flame loss, combustion, gas solenoid valves, flame rod and ground.Gas pressure and gas-valve work need a qualified service technician (Service manual (2011), p. 55)
- NRCB: check flame, combustion, gas valve, flame rod and ground.Gas pressure and gas-valve work need a qualified service technician (NRCB service manual (2020), p. 18)
- Clean the flame rod; check for sufficient gas; check venting (DV intake drawing exhaust; DVC units need the correct concentric vent).Burner work and venting changes (Noritz Help Center: 12)
Please don’t
- Don’t open the burner, the gas valve or the sealed combustion chamber.
- Don’t keep resetting a code that keeps coming back. A code that returns means the cause is still there.
- Don’t bypass or unplug a safety sensor to get hot water back.
- Don’t cover, tape or move the vent or the air intake.
Heater getting old, or the same code keeps coming back? Repair or replace? Three taps and Dan’s answer → Or see what a water heater repair usually involves.
Common questions
Noritz code 12 questions
What’s the difference between Noritz code 11 and 12?
11 means the burner never lit. 12 means it lit, then the flame went out while it was running.
Where this comes from
Sources
Taken from Noritz’s own documents, checked November 13, 2026. Page numbers are the printed page. Where models differ, we say which model each part applies to.
- Service Manual - Condensing Tankless Gas Water Heater (EZ111DV, EZ98DV, EZ71DV, NRCR111DV, NRCR92DV, NCC199CDV) Noritz America · Rev. 3/26 · Models: EZ111DV (GQ-C3261WX-FF(-1) US), EZ98DV (GQ-C2861WX-FF(-1) US), EZ71DV (GQ-C2661WX-FF(-1) US), NRCR111DV (GQ-C3261WXQ-FF(-1) US), NRCR92DV (GQ-C2661WXQ-FF(-1) US), NCC199CDV (GQ-C3261WZ-FF(-1) US)
- Noritz Help Center: Error Code 12 Noritz America · modified 2023-06-13 · Models: general
- Service Manual - Gas Water Heater: GQ-2457WS(-FFA) US [NR83], GQ-C2857WS(-FF) US [NRC98], GQ-C3257WX(-FF) US [NRC111], GQ-C3257WZ(-FF) US [NCC199], GQ-2857WX(-FFA,-F) US [NR98], GQ-2857WZ(-FFA) US [NC199] Noritz America · Rev: March, 2018 · Models: NR83 (-DVC,-OD), NRC98 (-DV,-OD), NRC111 (-DV,-OD), NCC199 (-DV,-OD), NR98 (-DVC,-OD,-SV), NC199 (-DVC,-OD)
- Service Manual - Condensing Tankless Gas Water Heater, Models NRCP1112-DV / NRCP982-DV (Eco TOUGH) Noritz America · Rev.05/19 · Models: NRCP1112-DV, NRCP982-DV
- Service Manual - Gas Water Heater: NR50-OD; NR66/N-0531S; NR71/N-0631S; NR98/NC199/N-0751M; NCC199/N-0841MC; NRC111/N-0842MC; NR111/NC250/N-0931M; NC380/N-1321M-ASME Noritz America · Rev: July, 2011 · Models: NR50-OD, NR66, NR71, NR98, NC199, NCC199, NRC111, NR111, NC250-ASME, NC380-ASME, N-0531S, N-0631S, N-0751M, N-0841MC, N-0842MC, N-0931M, N-1321M-ASME
- Owner’s Guide - Condensing Tankless Gas Water Heater, Models NRCP111-DV / NRCP98-DV Noritz America · Rev.05/19 · Models: NRCP111-DV, NRCP98-DV
- Owner’s Guide - Condensing Tankless Gas Water Heater (EZ111DV/EZ98DV/EZ71DV, NRCR111DV/NRCR92DV, GQ-C**61...-1) Noritz America · SBB81M1 · Rev. 10/25 · Models: EZ111DV (GQ-C3261WX-FF-1 US), EZ98DV (GQ-C2861WX-FF-1 US), EZ71DV (GQ-C2661WX-FF-1 US), NRCR111DV (GQ-C3261WXQ-FF-1 US), NRCR92DV (GQ-C2661WXQ-FF-1 US)
- Service Manual - Condensing Tankless Gas Water Heater, Models NRCP111-DV / NRCP98-DV Noritz America · Rev.09/19 · Models: NRCP111-DV, NRCP98-DV
- Service Manual - Condensing Gas-Fired Combination Boiler NRCB199DV (GHQ-C3201WX-FF US) / NRCB180DV (GHQ-C2801WX-FF US) Noritz America · Rev: September 2020 (cover also shows 2022) · Models: NRCB199DV, NRCB180DV
Water heater help
More about water heaters
Code won’t clear?
If you’re within about 30 miles of Westlake Village, call or text Dan a photo of the display and the label. He’ll tell you what it is.
Or send the details and Dan will call you back. Monday to Friday, 9am – 5pm.