Navien · Error code E110 · Checked November 2026
Navien error code E110: air or exhaust blocked
Air or exhaust isn’t moving through the heater the way it should. A clogged air intake filter or a blocked vent is the usual cause.
Smell gas? Don’t touch any switch or try to reset anything. Leave the house, then call 911 or your gas company from outside. In Southern California that’s SoCalGas, 1-800-427-2200.
From Dan and Dave at Dan's Plumbing, a family plumbing shop in Westlake Village, California. Everything below comes from Navien’s own documents, cited line by line.
What it means
What Navien says code E110 means
“Abnormal air pressure”— User’s Information Manual - NPE Condensing Water Heaters (NPE-180A2, NPE-210A2, NPE-240A2, NPE-180S2, NPE-210S2, NPE-240S2), page 17
Navien calls E110 “abnormal air pressure” on its tankless water heaters and “exhaust blockage” on the NCB-H and NCB700 combi-boilers and the NHB-H and NFB-H boilers. Either way, air isn’t moving through the heater the way it should.
The cause Navien names most is a clogged air intake filter. The owner’s manual says dust and lint clog it and to clean it every 3 to 4 months. Navien does walk owners through it, but it means turning the heater off, unplugging it and taking off the front cover. If you’d rather not, it’s a quick job for a pro.
Model differences. Water heaters and NCB-E call it 'Abnormal air pressure'; NCB-H, NCB700, NHB-H and NFB-H call it 'Exhaust Blockage'. NPN lists only the vent check (no air filter step). Only the NCB700 manual mentions the condensate drain for E110.
Sub-codes. Some models add a number after the code. Here’s what Navien’s manuals say each one means:
- E110-1 exhaust blockage (checking the FAN); E110-2 exhaust blockage (using hot water); E110-3 exhaust blockage (using space heating). (NPE service manual (2020), p. 76)
- NPN: E110-1 abnormal air pressure. (NPN service manual (2025), p. 76)
Why it happens
Likely causes of Navien code E110
- Air intake filter clogged by dust or lint: the heater stops and shows 'Error Code 110'. (NPE-2 user’s manual, p. 14; NPE user’s manual, p. 13; NCB-H user’s manual, p. 16)
- Blocked intake, exhaust or condensate drain pipe (ice, snow, wildlife and so on). (NPE-2 service manual (2025), p. 74)
- Condensate drain trouble blocks the exhaust: frozen condensate hose or siphon, kinked hose, or a blocked trap. (NPE-2 service manual (2025), p. 98)
- Clogged venturi (burner) hole, flue installed wrong or too close to things, rainwater collected in a badly installed intake/exhaust pipe, or a bad air pressure sensor (APS) or PCB. (NPE-2 service manual (2025), p. 97)
- Exhaust gas getting pulled back into the air intake causes bad combustion and E110. (NPE-2 service manual (2025), p. 98)
- Broken or clogged APS hose. (NPE-2 service manual (2025), p. 98)
- NPN: debris in the exhaust pipe, debris on the heat exchanger surface, condensate in the exhaust duct, or a bad APS. (NPN service manual (2025), pp. 78, 91)
What to do
Safe checks first. Then call a pro.
Safe checks you can do
Look outside at the exhaust (vent) pipe and make sure nothing is blocking it. (NPE-2 user’s manual, p. 17)
Clean the air intake filter. Navien’s owner’s manual has you turn the heater off, unplug it, remove the front cover and the one screw holding the filter, rinse it, let it dry and put it back. Navien says to do this every 3-4 months. (NPE-2 user’s manual, pp. 14, 17)
NCB700: check that the condensate drain outlet is not blocked and is draining properly. (NCB700 installation manual, p. 136)
Look at the intake and exhaust pipe ends outside and clear snow, ice, nests or debris. Check the condensate drain hose outside the heater is not kinked or frozen. (NPE-2 service manual (2025), pp. 74, 98)
To clear the code:
- NPE-A2/S2: press the Back button on the front panel to reset. If that does not fix it, see Troubleshooting or call Technical Support at 1-800-519-8794. Settings are kept during a power outage. (NPE-2 user’s manual, pp. 10, 16)
- NPE-A/NPE-S: press the Reset button on the front panel. (NPE user’s manual, pp. 9, 15)
- NPN: press the Reset button on the front panel (indoor models), or press the OK button once on the remote controller (outdoor models); 'RST' appears on the remote. (NPN user’s manual, pp. 12, 21)
- NCB-E combi-boiler: press the Reset button on the front panel. (NCB-E user’s manual, pp. 11, 21)
What a technician checks, and why
- Check the exhaust venting.Vent inspection or changes beyond a visual check are technician work. Listed for NHB-H/NFB-H. (NHB-H user’s manual, p. 24)
- If E110 comes and goes at ignition or during firing, compare the standard fan RPM with the actual RPM at min and max fire (PCB DIP 1-1 and 1-2). Higher than normal points to a vent blockage, a blocked condensate drain, or a broken/clogged APS hose.Vent system inspection or changes; carbon monoxide risk. (NPE-2 service manual (2025), p. 98)
- Take off the bottom of the condensate trap and make sure it is not blocked.Trap is inside the cabinet. (NPE-2 service manual (2025), p. 98)
- Check the venturi (burner) hole for clogging and the flue for damage, obstruction and collected rainwater.Vent system inspection or changes; carbon monoxide risk. (NPE-2 service manual (2025), pp. 97-98)
- Check the vent termination is at least 12 in. (305 mm) above the highest expected snow line, or what local code requires, whichever is greater; check intake-to-exhaust spacing so exhaust is not pulled back in.Vent system inspection or changes; carbon monoxide risk. (NPE-2 service manual (2025), p. 98)
- Check the APS: RED-BLACK DC 5 V, WHITE-BLACK DC 0.3-4.5 V; also check the condensate trap and drain piping.Sensor and wiring checks inside the cabinet with a meter. (NPE-2 service manual (2025), p. 64)
- Replace an old PCB with the latest version.Control board diagnosis or replacement. (NPE-2 service manual (2025), p. 98)
- NPN: check the APS, fan RPM, exhaust flue, heat exchanger surface for foreign matter, and condensate in the exhaust duct; clear foreign matter around the exhaust, then reset.Vent system inspection or changes; carbon monoxide risk. (NPN service manual (2025), p. 91)
Please don’t
- Don’t open the burner, the gas valve or the sealed combustion chamber.
- Don’t keep resetting a code that keeps coming back. A code that returns means the cause is still there.
- Don’t bypass or unplug a safety sensor to get hot water back.
- Don’t cover, tape or move the vent or the air intake.
Heater getting old, or the same code keeps coming back? Repair or replace? Three taps and Dan’s answer → Or see what a water heater repair usually involves.
Common questions
Navien code E110 questions
What does E110 01 mean on a Navien?
It depends on the model. Navien’s NPE-A and NPE-S service manual says E110-1 is an exhaust blockage found while checking the fan, E110-2 while using hot water, and E110-3 while heating the house. The NPN service manual lists E110-1 as abnormal air pressure. Either way, air or exhaust isn’t flowing the way it should.
How often should I clean a Navien air filter?
Navien’s NPE owner’s manual says every 3 to 4 months, more often if the heater is somewhere dusty or near a dryer.
Where this comes from
Sources
Taken from Navien’s own documents, checked November 13, 2026. Page numbers are the printed page. Where models differ, we say which model each part applies to.
- User’s Information Manual - NPE Condensing Water Heaters (NPE-180A2, NPE-210A2, NPE-240A2, NPE-180S2, NPE-210S2, NPE-240S2) Navien, Inc. · 20049624A · Version 1.0 (2020); PDF file NPE-A2_S2_User’s_Information_Manual_EN_CAFR_201202 · Models: NPE-180A2, NPE-210A2, NPE-240A2, NPE-180S2, NPE-210S2, NPE-240S2
- Service Manual - NPE Condensing Water Heaters (NPE-180A, NPE-210A, NPE-240A, NPE-150S, NPE-180S, NPE-210S, NPE-240S) Navien, Inc. · file NPE_Service_Manual_EN_200130 · Version 2.40 (Jan. 2020) on back cover; page footers say Version 2.21 · Models: NPE-180A, NPE-210A, NPE-240A, NPE-150S, NPE-180S, NPE-210S, NPE-240S
- Service Manual - NPN Non-Condensing Water Heaters (NPN-160U, NPN-180U, NPN-199U, NPN-160E, NPN-180E, NPN-199E) Navien, Inc. · file NPN_Service_Manual_EN_250108 · Version 1.0 (January, 2025) on back cover; revision table shows 1.0 First Issue September 2019 · Models: NPN-160U, NPN-180U, NPN-199U, NPN-160E, NPN-180E, NPN-199E
- User’s Information Manual - NPE Condensing Water Heaters (NPE-180A, NPE-210A, NPE-240A, NPE-150S, NPE-180S, NPE-210S, NPE-240S) Navien, Inc. · 20026535G · Version 5.3 (May 23, 2019) · Models: NPE-180A, NPE-210A, NPE-240A, NPE-150S, NPE-180S, NPE-210S, NPE-240S
- User’s Information Manual - NCB-H Condensing Combi-Boilers (NCB-190/060H ... NCB-250/150H) Navien, Inc. · Version 1.0 (April, 2024) · Models: NCB-190/060H, NCB-190/080H, NCB-240/110H, NCB-240/130H, NCB-250/150H
- Service Manual - NPE Condensing Water Heaters (NPE-180A2, NPE-210A2, NPE-240A2, NPE-180S2, NPE-210S2, NPE-240S2, NPE-150S2) Navien, Inc. · file NPE-A2_S2_Service_Manual_EN_250122 · Version 1.1 (January, 2025) on back cover; revision table shows 1.00 First Issue March 24, 2020 · Models: NPE-180A2, NPE-210A2, NPE-240A2, NPE-180S2, NPE-210S2, NPE-240S2, NPE-150S2
- Installation & Operation Manual - NCB700 Condensing Combi-Boilers Navien, Inc. · Version 1.0 (July, 2026) · Models: NCB700-190/060, NCB700-190/080, NCB700-240/110, NCB700-240/130, NCB700-250/150
- User’s Information Manual - NHB-H Condensing Boilers (NHB-055H/080H/110H/150H) Navien, Inc. · Version 1.0 (April, 2024) · Models: NHB-055H, NHB-080H, NHB-110H, NHB-150H
Water heater help
More about water heaters
Code won’t clear?
If you’re within about 30 miles of Westlake Village, call or text Dan a photo of the display and the label. He’ll tell you what it is.
Or send the details and Dan will call you back. Monday to Friday, 9am – 5pm.