Tankless water heaters · 54 codes · Checked November 2026
Takagi error codes, in plain words
Takagi codes are three digits, like 111 or 991. Here’s every code in Takagi’s manuals, troubleshooting guides and service handbooks, in plain words. A few codes point to a different part on different models, so we say which model each one applies to.
From Dan and Dave at Dan's Plumbing, a family plumbing shop in Westlake Village, California. Every line below comes from Takagi’s own documents, with the page it’s on.
Smell gas? Don’t touch any switch or try to reset anything. Leave the house, then call 911 or your gas company from outside. In Southern California that’s SoCalGas, 1-800-427-2200.
Every code
All 54 Takagi codes
Home tankless heaters made today
110, 310 and 510 (T-KJr2, T-K4, T-D2), the U and C versions, the H and HX3 condensing models (140, 240, 340, 540), 540P and X3P.
-
The small DIP switches on the control board are set wrong for this heater.Incorrect DIP switch setting
The small DIP switches on the control board are set wrong for this heater. A common one is the gas type switch (natural gas vs. propane). (110/310/510 troubleshooting guide)
By model: 110 (T-KJr2)/310 (T-K4): red LED flashes once; TK-RE02 remote shows 03 (im-62s051 p.47). All other current models: green LED one flash. T-H1 chart calls 031 'Wrong Gas Type' (im-th1 p.17). On the old T-KJr the 2-digit code 03 = 'Wrong Gas' (im-tkjr p.17).
Likely causes
- Gas type is a common dipswitch error. (110/310/510 troubleshooting guide, p. 13)
- Easy-Link systems: the master (parent) heater needs DIP switch No. 10 on the right bank ON; child heaters need it OFF. (110/310/510 troubleshooting guide, p. 13)
- X3P models: also shown if DIP switches were changed while the heater power was on. (X3P service handbook, p. 16)
For a technician
- Turn off power, remove the front cover, and check both DIP switch banks against the settings table. (110/310/510 troubleshooting guide, pp. 13, 19-20)
- Check gas type, vent-length and altitude DIP switch settings against the tables, then turn power back on. (T-H3 service handbook, p. 14)
-
The heater found a problem with air coming in or exhaust going out, right after it shut off.Insufficient combustion air and gas (manual) / Combustion Air and/or Exhaust Gas Blockage (service handbook)
The heater found a problem with air coming in or exhaust going out, right after it shut off. It checks this once a day. (X3P manual)
By model: Only listed for 160X3P/180X3P/199X3P. Green LED: three flashes (im-2000570774 p.71).
Likely causes
- Dust and dirt on the air screen of the rain protection tray, or a blocked air intake. (X3P manual, p. 73)
- Wiring or computer-board fault in the air pressure sensor circuit (parts 123, 715, 701). (X3P manual, p. 73)
- Same causes as 991: wrong gas type/orifice, wrong altitude or vent-length DIP switches, blocked intake or exhaust. (X3P service handbook, pp. 15, 22-23)
What you can check
- Look at the vent and air intake outside and make sure the air intake is not blocked. (X3P manual, p. 73)
For a technician
- Clean the air screen of the rain protection tray (front cover must come off). (X3P manual, pp. 69, 73)
- Check wires to the air pressure sensor (parts 123, 715) and the computer board for burn marks; then follow the 991 procedure. (X3P service handbook, pp. 11, 22-24)
-
The burner is getting too much gas for the air it has.Warning for the “991” error code (Abnormal Combustion)
The burner is getting too much gas for the air it has. The heater keeps running for now, but it will shut down with code 991 if the problem is not fixed. (110/310/510 troubleshooting guide)
By model: 110 (T-KJr2)/310 (T-K4): red LED five flashes; TK-RE02 shows 10. X3P (160/180/199X3P): named 'Combustion air and exhaust air blockage warning' and appears during the pre-purge (sh-2000585401 p.22-23). The discontinued T-H1 uses 101 for 'Insufficient Gas Supply' (see separate entry).
Likely causes
- Blockage in the airway: vent obstruction (birds' nests, trash), backflow preventer installed backwards, heat exchanger, fan. (110/310/510 troubleshooting guide, p. 13)
- Undersized gas lines can lead to a 101 or 991 error code. (T-H3 service handbook, p. 14)
- Gas type of the heater does not match the gas supplied. (110/310/510 manual, p. 47)
- Intake air contaminated with dust, lint (laundry nearby), grease (kitchens) building up in the burner and fan. (110/310/510 troubleshooting guide, p. 13)
- Weather: high winds, frozen vent termination flap. (110/310/510 troubleshooting guide, p. 13)
- High altitude: a DIP switch change is required above 2,000 ft (T-H3 family). (T-H3 service handbook, p. 21)
- Installations around or over 3,000 ft need the FM+ DIP switch settings (110/310/510). (110/310/510 troubleshooting guide, p. 13)
- Direct-vent intake and exhaust terminals too close together. (110/310/510 manual, p. 47)
What you can check
- Check outside that the intake air and exhaust are not blocked. (110/310/510 manual, p. 47)
- Keep the area around the heater, vent termination and air intake free of dust, debris and lint. (H-series manual (140H–540H), p. 54)
For a technician
- Check and, if needed, adjust manifold gas pressure (only with Takagi technical support approval on T-H3 family). (T-H3 service handbook, p. 22)
- Clean the burner and fan if contaminated. (110/310/510 troubleshooting guide, p. 13)
- Set altitude/vent-length DIP switches correctly. (110/310/510 troubleshooting guide, p. 13)
- After the cause is fixed, reset the computer board to clear the code. (110/310/510 troubleshooting guide, pp. 13, 23)
-
The burner did not light after three tries.Ignition failure
The burner did not light after three tries. (110/310/510 troubleshooting guide)
By model: 110/310 (T-KJr2/T-K4): red LED three flashes; TK-RE02 shows 11. X3P valve resistances differ: MV 1.15-1.65 kOhm, SV1 1.35-1.65, SV2/SV3 2.07-2.53 (sh-2000585401 p.17). On the old T-KJr the 2-digit code 11 = 'Hi-limit, Igniter' (im-tkjr p.17).
Likely causes
- High-limit switch tripped. (110/310/510 troubleshooting guide, p. 13)
- Not enough gas: gas valve not fully open, faulty pressure regulator at the meter, air or debris in the gas line. (110/310/510 troubleshooting guide, pp. 13-14)
- Propane units: a cold regulator in colder periods of the day. (110/310/510 troubleshooting guide, p. 14)
- Gas pressure drops more than 1 to 1.5 in. W.C. at full demand: not enough fuel reaching the heater. (T-H3 service handbook, p. 14)
- Clear plastic tube from the proportional gas valve to the combustion chamber disconnected. (110/310/510 troubleshooting guide, p. 14)
- Overheat cutoff fuse (OHCF) open. (110/310/510 troubleshooting guide, p. 14)
- Dirty flame sensor (flame lights 1-2 seconds then goes out). (110/310/510 troubleshooting guide, p. 14)
- No spark or weak spark from the igniter. (110/310/510 troubleshooting guide, p. 14)
- Blocked venting (bird nests, animals, trash). (110/310/510 troubleshooting guide, p. 14)
- Computer board or gas solenoid valve fault. (110/310/510 troubleshooting guide, p. 14)
- Water leaking from the heat exchanger. (110/310/510 manual, p. 47)
What you can check
- Make sure the gas supply valve is fully open. (110/310/510 manual, p. 44)
- Propane: check there is enough gas in the tank. (110/310/510 manual, p. 44)
- Check that the gas is turned on. (910 (T-M50) manual, p. 44)
- Turn hot water off. The code clears when water flow stops; then try again. (110/310/510 manual, p. 47)
For a technician
- Reset the high-limit switch (white button) with power off; if it trips again find the cause (possibly scale: descale; check incoming water is not pre-heated). (T-H3 service handbook, pp. 14-15)
- Descale the heat exchanger if the high-limit keeps tripping. (T-H3 service handbook, pp. 15, 38)
- Measure inlet gas pressure static and at full fire; purge air from the gas line. (110/310/510 troubleshooting guide, pp. 14, 21-22)
- Check the clear plastic tube between the proportional valve and combustion chamber. (110/310/510 troubleshooting guide, p. 14)
- Test the overheat cutoff fuse for continuity. (T-H3 service handbook, pp. 15, 35)
- Clean or replace the flame sensor; check igniter spark, igniter wires and 108-132 VAC across the igniter wires. (T-H3 service handbook, p. 15)
- Check main gas valve resistance (1.35-1.65 kOhm) and solenoid valves (SV1/SV2 1.35-1.65 kOhm, SV3 2.07-2.53 kOhm). (T-H3 service handbook, p. 15)
-
The burner lit, then the flame went out while hot water was still running, and it could not relight.Loss of flame / Flame loss
The burner lit, then the flame went out while hot water was still running, and it could not relight. (110/310/510 troubleshooting guide)
By model: 110/310 (T-KJr2/T-K4): red LED three flashes; TK-RE02 shows 12. On the old T-KJr, 12 = 'Flame Sensor, Hi-limit' (im-tkjr p.17).
Likely causes
- High-limit switch tripped. (110/310/510 troubleshooting guide, p. 14)
- Not enough gas, faulty regulator at the meter, cold propane regulator. (110/310/510 troubleshooting guide, p. 14)
- Clear plastic tube to the combustion chamber disconnected. (110/310/510 troubleshooting guide, p. 14)
- Dirty flame sensor (flame on 1-2 seconds, then out). (110/310/510 troubleshooting guide, p. 14)
- Overheat cutoff fuse compromised. (110/310/510 troubleshooting guide, p. 14)
- Blocked venting. (110/310/510 troubleshooting guide, p. 14)
- Computer board or gas solenoid fault. (110/310/510 troubleshooting guide, p. 14)
- Water leaking from the heat exchanger. (110/310/510 manual, p. 47)
What you can check
- Make sure the gas supply valve is fully open; for propane, make sure the tank has gas. (110/310/510 manual, p. 44)
- Turn hot water off. The code clears when water flow stops; then try again. (110/310/510 manual, p. 47)
For a technician
- Reset/check the high-limit switch, check gas pressure in standby and running, check the clear tube, clean the flame sensor, test the OHCF, check venting. (110/310/510 troubleshooting guide, p. 14)
- Follow the combined 111/121 procedure in the service handbook (high limit, OHCF, igniter, MV and SV resistance). (T-H3 service handbook, pp. 14-15)
-
The heater found a problem with its air or gas supply system, such as the high-limit switch, the fan, or the air pressure sensor.Combustion air and gas line failure
The heater found a problem with its air or gas supply system, such as the high-limit switch, the fan, or the air pressure sensor. (X3P manual)
By model: Only listed for X3P models. Green LED: one flash.
Likely causes
- High-limit switch tripped. (X3P manual, p. 73)
- Fan motor not working properly. (X3P manual, p. 73)
- Pressure sensor (part 123) not working; wire breakage or burn marks on the computer board. (X3P service handbook, pp. 12, 17)
For a technician
- Check the high-limit switch (reset button in its center); if it keeps tripping, call a qualified technician. (X3P manual, p. 73)
- Check the pressure sensor, fan motor and wiring/computer board. (X3P service handbook, p. 17)
-
The sensor that checks air pressure inside the heater is not working or its wiring is bad.Air pressure sensor failure (manual: Pressure sensor failure)
The sensor that checks air pressure inside the heater is not working or its wiring is bad. (X3P manual)
By model: X3P only. The discontinued T-H1 used 211 for 'Vent Pipe Obstruction' (separate entry).
Likely causes
- Wire breakage (parts 123, 715) or burn marks on the computer board. (X3P manual, p. 73)
For a technician
- Check 4 to 6 VDC between black and red wires during operation; replace the sensor if out of range, the board if in range. (X3P service handbook, p. 17)
-
Condensate (acidic water the heater makes) cannot drain.Blocked condensate drain system
Condensate (acidic water the heater makes) cannot drain. The drain line, neutralizer or inside drain may be clogged. (H-series manual (140H–540H))
By model: Listed in the 2021 manual for 140H/240H/340H/540H (im-68a161 p.59-60) and for 240HX3/340HX3/540HX3 (im-2000599585 p.54). Not listed in the 2016 T-H3 service handbook or the older 140 (T-H3M) manual 88A161. Green LED: five flashes.
Likely causes
- Blockage in the condensate drain line or neutralizer. (H-series manual (140H–540H), p. 60)
- Blockage in the condensate drain assembly inside the heater (parts 416, 421, 423). (H-series manual (140H–540H), p. 60)
- Horizontal drain runs not sloped downward, or sags in the drain line. (H-series manual (140H–540H), p. 60)
What you can check
- Check the condensate drain hose and neutralizer outside the heater for clogs or kinks; make sure horizontal runs slope downward with no sags. (H-series manual (140H–540H), p. 60)
For a technician
- Clear the condensate drain assembly inside the heater (parts 416, 421, 423). (HX3 manual, p. 54)
-
A temperature sensor in the heater is bad, dirty or unplugged.Outlet (output) thermistor failure; on some models Heat exchanger thermistor failure
A temperature sensor in the heater is bad, dirty or unplugged. Which sensor depends on the model. (110/310/510 troubleshooting guide)
By model: Output/outlet thermistor on 110/310/510, T-M50, T-M32, T-H2, 140 (T-H3M), 240/340 (T-H3J/T-H3S), 110C/310C, 240HX3/340HX3, T-H1. Heat exchanger thermistor on 540 (T-H3) / 540H (sh-2000534342 p.11; im-68a161 p.60), 540P (im-2000536265 p.68), 510C (im-2000535218 p.42), 540HX3 (im-2000599585 p.55), X3P (im-2000570774 p.73). 'Outlet and Mixing thermistor failure' on 110U/310U/510U (im-60z101 p.45). 110/310 red LED two flashes, TK-RE02 shows 31.
Likely causes
- Loose, burned or cut thermistor wires. (110/310/510 troubleshooting guide, p. 15)
- Debris/scale on the thermistor probe. (110/310/510 manual, p. 47)
- Failed thermistor (resistance out of range). (110/310/510 troubleshooting guide, p. 15)
For a technician
- Check wiring; check resistance (about 9.0 kOhm at about 74 F on T-KJr2/T-K4/T-D2; use the resistance table on T-H3 family). (110/310/510 troubleshooting guide, p. 15)
- Drain the unit, pull the probe, clean it to a silver finish (keep the o-ring), reinstall; replace if the code persists. (T-H3 service handbook, pp. 16-17)
-
The sensor that reads the incoming cold water temperature is bad, dirty or unplugged.Inlet thermistor failure
The sensor that reads the incoming cold water temperature is bad, dirty or unplugged. (110/310/510 troubleshooting guide)
By model: Same meaning on every Takagi document checked. 110/310 red LED two flashes, TK-RE02 shows 32. On the old T-KJr, 32 = 'Input Thermistor'.
Likely causes
- Loose, burned or cut wires; the inlet thermistor is in the water inlet connection. (110/310/510 troubleshooting guide, p. 15)
- Debris on the thermistor. (110/310/510 manual, p. 47)
For a technician
- Check wiring and resistance (about 9.0 kOhm at about 74 F); drain, remove the computer board to reach the probe, clean to a silver finish, replace if it persists. (110/310/510 troubleshooting guide, p. 15)
-
A temperature sensor is bad, dirty or unplugged.Mixing thermistor failure / Outlet thermistor failure / Heat exchanger thermistor failure (by model)
A temperature sensor is bad, dirty or unplugged. On some models it is the mixing sensor, on others the outlet sensor. (110/310/510 troubleshooting guide)
By model: Mixing thermistor: 510 (T-D2) only in that family (im-62s051 p.47), T-M50, T-M32, T-H2, T-H1. Outlet thermistor: 540 (T-H3) / 540H only (sh-2000534342 p.12; im-68a161 p.61), 540P, 510C only, 540HX3 only, X3P. Heat exchanger thermistor: 510U (T-D2U) only (im-60z101 p.45). Not used on 110/310 (T-KJr2/T-K4), 240/340 (T-H3J/S) or 140 (T-H3M).
Likely causes
- Loose, burned or cut wires; debris on the thermistor. (110/310/510 troubleshooting guide, p. 15)
For a technician
- Check wiring and resistance; drain, clean the probe to a silver finish (keep the red o-ring), replace if it persists. (110/310/510 troubleshooting guide, p. 15)
-
The sensor that reads exhaust temperature on an indoor condensing model is bad, dirty or unplugged.Exhaust thermistor failure (indoor models only)
The sensor that reads exhaust temperature on an indoor condensing model is bad, dirty or unplugged. (T-H2 troubleshooting guide)
By model: Indoor models only on T-H3 family, 140 (T-H3M), 540P and HX3. X3P lists it without an indoor-only note (im-2000570774 p.73).
Likely causes
- Loose, burned or cut wires; dirty probe. (T-H2 troubleshooting guide, p. 17)
For a technician
- Check wiring; resistance about 10.75 kOhm at about 74 F (T-H2); clean the probe (keep the white gasket) or replace. (T-H2 troubleshooting guide, p. 17)
- Use the exhaust-thermistor column of the resistance table on T-H3 family. (T-H3 service handbook, p. 16)
-
The sensor on the recirculation return line is bad, dirty or unplugged.Return thermistor failure
The sensor on the recirculation return line is bad, dirty or unplugged. (540P manual)
By model: Only on the built-in-pump models 540P and X3P. Green LED two flashes.
Likely causes
- Wire breakage or debris on the thermistor. (540P manual, p. 68)
For a technician
- Check thermistor wiring and resistance; see the thermistor procedure in the X3P service handbook. (X3P service handbook, pp. 12, 18)
-
A flame-sensing rod is not seeing flame.Air-fuel ratio rod failure (X3P: Flame rod failure)
A flame-sensing rod is not seeing flame. It is often dirty, or the ground wire is loose. (T-H3 service handbook)
By model: X3P names it 'Flame rod failure' (im-2000570774 p.74). 110/310: red LED two flashes, TK-RE02 shows 39. The old T-H1 uses 391 for 'Abnormal Thermocouple' (separate entry).
Likely causes
- A floating ground can cause this error. (T-H3 service handbook, p. 17)
- Loose, burned or cut wires; green ground wire not connected. (T-H3 service handbook, p. 17)
- Clear plastic tube from the proportional gas valve to the combustion chamber disconnected. (110/310/510 troubleshooting guide, p. 16)
- Soot on the AFR rod. (110/310/510 manual, p. 48)
What you can check
- Make sure the heater is plugged into a properly grounded outlet. (T-H3 service handbook, p. 17)
For a technician
- Check wiring and ground wire; check the clear tube; clean the AFR rod / flame rod. (T-H3 service handbook, pp. 17, 36)
-
In a group of linked heaters, one heater was told to turn on but did not sense water flow.Flow sensor failure (Easy-Link / Multi-Unit system only on most models)
In a group of linked heaters, one heater was told to turn on but did not sense water flow. (110/310/510 troubleshooting guide)
By model: Easy-Link only on 510 (T-D2), 510U, T-H3 family, T-M50, T-M32, T-H2, 510C. On X3P it also shows when no flow is seen while the built-in pump runs; check valves, return filter, pump pressure drop (sh-2000585401 p.19; im-2000570774 p.74). Green LED two flashes.
Likely causes
- No water supply to the heater in error (isolation valves closed). (110/310/510 troubleshooting guide, p. 16)
- Flow sensor wires disconnected. (110/310/510 troubleshooting guide, p. 16)
- Debris in the inlet filter or on the flow sensor impeller. (110/310/510 troubleshooting guide, p. 16)
What you can check
- Make sure the shutoff valves on the hot and cold lines to the heater are open. (H-series manual (140H–540H), p. 61)
- Clean the cold-water inlet filter (Owner’s Guide draining and filter-cleaning steps). (H-series manual (140H–540H), pp. 54, 61)
For a technician
- Disconnect the heater from the linked system and test it alone; check flow reading on the controller; remove and check the flow sensor. (T-H3 service handbook, p. 17)
-
The control board found a problem in the gas valve circuit.Abnormal main gas solenoid valve (MV) - name varies by document
The control board found a problem in the gas valve circuit. Most manuals say the main gas valve. (110/310/510 troubleshooting guide)
By model: Takagi documents disagree on which valve 510 means: 110/310/510 troubleshooting guide = 'Abnormal Gas Valves', main or solenoid (tg-321923 p.16); the 110/310/510 owner’s guide = 'Abnormal gas solenoid valve' (im-62s051 p.48); 110U/310U/510U = 'Abnormal Gas Solenoid Valve' (im-60z101 p.46); T-H3 family, 140H, 540P, 110C/310C/510C, HX3 = 'Abnormal main gas solenoid valve' (MV); T-M50, T-M32, T-H1 = 'Abnormal Main Gas Valve'; T-H2 = 'Abnormal main and/or solenoid gas valve' (tg-321922 p.18); T-H3M handbook = 'Abnormal main OR abnormal solenoid gas valve' (sh-100267626 p.11). X3P manual lists it as '511/510' (see 511). 110/310 red LED six flashes; TK-RE02 shows 51. On the old T-KJr, 51 = 'Proportional Gas Valve'.
Likely causes
- Burned or cut wires to the gas valve assembly. (110/310/510 troubleshooting guide, p. 16)
- Gas valve wires plugged into the wrong place after a repair. (110/310/510 troubleshooting guide, p. 16)
- Inlet gas pressure too high can jam or damage the main gas valve. (T-H3 service handbook, p. 17)
- Rust or corrosion on gas valve contacts and harness; vent corrosion. (910 (T-M50) manual, p. 44)
- Burn marks on the computer board. (110/310/510 manual, p. 48)
What you can check
- If you turn off the hot water and still see flame through the window, shut off gas and power to the heater at once and call for service. (110/310/510 troubleshooting guide, p. 16)
For a technician
- Check wiring and plug positions (stamped numbers must match wire labels). (T-H3 service handbook, p. 17)
- Verify supply gas pressure is within limits. (T-H3 service handbook, p. 17)
- With power off, MV resistance 1.35-1.65 kOhm; during operation 93-120 VDC across MV wires; replace valve or board as indicated. (T-H3 service handbook, pp. 17-18)
-
The control board found a problem in the main gas valve circuit.Abnormal main gas valve (MV)
The control board found a problem in the main gas valve circuit. (X3P manual)
By model: X3P only; the manual’s table shows '511/510' together (im-2000570774 p.74). Green LED six flashes.
Likely causes
- Breakage of the blue and brown wires to the gas valve assembly, or burn marks on the computer board. (X3P manual, p. 74)
- Inlet gas pressure too high can jam or damage the main gas valve. (X3P service handbook, p. 19)
What you can check
- If you turn off the hot water and still see flame through the window, shut off gas and power to the heater at once and call for service. (X3P service handbook, p. 19)
For a technician
- Check wiring; check MV resistance 1.15-1.65 kOhm with power off and 93-120 VDC during operation. (X3P service handbook, p. 19)
-
On a 110 (T-KJr2) or 310 (T-K4), the remote shows 55 for a gas valve circuit problem.Abnormal main gas valve (owner’s guide) / Abnormal solenoid gas valve (troubleshooting guide)
On a 110 (T-KJr2) or 310 (T-K4), the remote shows 55 for a gas valve circuit problem. (110/310/510 manual)
By model: 2-digit code on the TK-RE02 remote, 110 (T-KJr2)/310 (T-K4) only; red LED six flashes. The owner’s guide says main gas valve; the troubleshooting guide says solenoid gas valve. Old T-KJr chart: 55 = 'Main Gas Valve' (im-tkjr p.17). 3-digit equivalent on 110U/310U/510U is 551.
Likely causes
- Wire breakage (part 708) or burn marks on the computer board. (110/310/510 manual, p. 48)
- Driving circuit fault for the solenoid gas valve; too-high inlet gas pressure. (110/310/510 troubleshooting guide, p. 16)
What you can check
- If you turn off the hot water and still see flame through the window, shut off gas and power to the heater at once and call for service. (110/310/510 troubleshooting guide, p. 16)
For a technician
- Check gas valve wiring and plug positions; verify supply gas pressure. (110/310/510 troubleshooting guide, p. 16)
-
The air damper inside the heater is stuck or not working.Air damper failure
The air damper inside the heater is stuck or not working. (X3P service handbook)
By model: X3P only. Green LED six flashes.
Likely causes
- Altitude DIP switches set wrong. (X3P service handbook, p. 19)
- Damper blocked by debris or loose; wire breakage or burn marks on the board. (X3P service handbook, p. 19)
For a technician
- Check altitude DIP switches; inspect the damper; check 3-11 VDC between COM (white) and brown during operation; reset with the 991 reset procedure. (X3P service handbook, pp. 19, 24)
-
The control board found a problem with one of the gas valves that open burner sections.Abnormal gas solenoid valve (SV1, SV2 and/or SV3)
The control board found a problem with one of the gas valves that open burner sections. (T-H3 service handbook)
By model: On 110U/310U/510U the owner’s guide calls 551 'Abnormal Main Gas Valve' (im-60z101 p.46). X3P: SV1 1.35-1.65 kOhm, SV2/SV3 2.07-2.53 kOhm (sh-2000585401 p.20). Green LED six flashes.
Likely causes
- Burned or cut wires; wires plugged into the wrong place after service. (T-H3 service handbook, p. 18)
- Inlet gas pressure too high. (T-H3 service handbook, p. 18)
- Rust or corrosion on gas valve contacts and harness. (910 (T-M50) manual, p. 44)
What you can check
- If you turn off the hot water and still see flame through the window, shut off gas and power to the heater at once and call for service. (910 troubleshooting guide, p. 16)
For a technician
- With power off, SV1/SV2 1.35-1.65 kOhm, SV3 2.07-2.53 kOhm; during operation 93-120 VDC per valve; replace valve or board. (T-H3 service handbook, p. 18)
-
The combustion fan is not running right.Fan motor fault (Abnormal fan motor)
The combustion fan is not running right. (110/310/510 troubleshooting guide)
By model: 110/310 red LED four flashes; TK-RE02 shows 61. On the old T-KJr, 61 = 'Fan'.
Likely causes
- Broken fan wiring, burn marks on the board, or moisture. (110/310/510 troubleshooting guide, p. 17)
- Water in the fan housing (may have damaged the motor). (110/310/510 troubleshooting guide, p. 17)
- Dust buildup in the fan motor; frozen or corroded connectors. (110/310/510 manual, p. 48)
- Blocked venting or contaminants (lint, dust) in the heater area. (T-H3 service handbook, p. 18)
What you can check
- Look outside for a blocked exhaust or air intake and clear it. (X3P manual, p. 74)
For a technician
- With power off, check fan wiring and board; check fan housing for water and dry it. (110/310/510 troubleshooting guide, p. 17)
- During operation check fan voltages: red-blue 132-192 VDC, yellow-blue 13-17 VDC, orange-blue 2-6.5 VDC; replace fan if in range, board if not. (T-H3 service handbook, p. 18)
-
The pump wired to the heater (outside pump on commercial models, built-in pump on 540P/X3P) has a problem.Pump failure / Abnormal external pump / Pump fault
The pump wired to the heater (outside pump on commercial models, built-in pump on 540P/X3P) has a problem. (910 troubleshooting guide)
By model: External pump on T-M50, T-M32, T-H2; built-in pump on 540P and X3P. Green LED four flashes on 540P/X3P.
Likely causes
- External pump connected to the board not working. (910 troubleshooting guide, p. 17)
- 540P: wire breakage in the pump, or water frozen in the pump. (540P manual, p. 69)
- X3P: water moving backwards through the pump (missing/failed check valve), debris in the pump, dirty return filter. (X3P service handbook, p. 20)
What you can check
- Clean the return and cold-water inlet filters (X3P Owner’s Guide). (X3P manual, p. 67)
For a technician
- X3P: verify the check valve on the return line; clean pump debris; check pump wiring; check pump voltages; replace pump or board. (X3P service handbook, p. 20)
-
The motorized valve that controls water flow through the heater is stuck, leaking or not wired right.Flow adjustment valve fault
The motorized valve that controls water flow through the heater is stuck, leaking or not wired right. (T-H3 service handbook)
By model: Easy-Link (or Multi-Unit) systems only on 510 (T-D2), 510U, T-H3 family, T-M50, T-M32, 540P, 510C. The old T-H1 used 651 for 'Abnormal Bypass Valve' (separate entry).
Likely causes
- Broken or disconnected wires; scale or debris locking the valve; water leakage. (T-H3 service handbook, p. 18)
For a technician
- Check resistance black-red 90-200 Ohm (power off) and 7-16 VDC at the board; replace valve or board. (T-H3 service handbook, pp. 18-19)
- Remove the valve, clean sediment with a brush or descaling solution, reinstall; replace if it cannot be cleaned. (110/310/510 troubleshooting guide, p. 17)
-
The bypass valve that mixes some cold water in is stuck, leaking or not wired right.Bypass valve fault (T-M50: Water control valve fault, bypass function; T-H2: Abnormal water bypass valve)
The bypass valve that mixes some cold water in is stuck, leaking or not wired right. (T-H3 service handbook)
By model: Only models with a bypass valve: 540 (T-H3)/540H, 510U only, 510C only, 540HX3 only, 540P, X3P, T-M50, T-M32, T-H2. The old T-H1 used 661 for 'Abnormal Output Adjustment Valve' (separate entry).
Likely causes
- Broken or disconnected wires; scale or debris locking the motor drive; water leakage at the valve. (T-H3 service handbook, p. 19)
For a technician
- Check resistance brown-red 50-85 Ohm (power off) and 3-11 VDC; replace valve or board. (T-H3 service handbook, p. 19)
- Remove and clean the valve with a brush or descaling solution. (910 troubleshooting guide, p. 18)
-
The control board, or the gas valve that adjusts the flame, has a fault.Computer board fault (T-H3 handbook: Computer Board Fault / Proportional Gas Valve Fault)
The control board, or the gas valve that adjusts the flame, has a fault. (110/310/510 troubleshooting guide)
By model: T-H2 guide: 'Proportional Gas Valve / Computer' (tg-321922 p.20). 110/310 red LED one flash; TK-RE02 shows 70. Old T-KJr: 70 = 'Computer Board'. The old T-H1 used 701 for 'Abnormal Mixing Thermistor' (separate entry).
Likely causes
- Loose, burned or cut wires; burn marks on the board. (110/310/510 troubleshooting guide, p. 17)
- Supply gas pressure out of spec. (110/310/510 troubleshooting guide, p. 17)
- Power supply problem. (110/310/510 manual, p. 48)
- Proportional valve resistance out of 20-40 Ohm range; outlet thermistor reading off. (T-H3 service handbook, p. 19)
For a technician
- Inspect board and wiring; check outlet vs. inlet thermistor reading; check proportional valve resistance (20-40 Ohm). (T-H3 service handbook, p. 19)
- Contact Takagi technical service. (110/310/510 troubleshooting guide, p. 17)
-
At power-up the board found a break in the gas valve, high-limit switch or overheat fuse circuit.Gas solenoid valve drive circuit failure (handbooks: High limit switch / Overheat cutoff fuse circuit is compromised)
At power-up the board found a break in the gas valve, high-limit switch or overheat fuse circuit. (T-H3 service handbook)
By model: T-H2 guide: may appear instead of 111 or 121 (tg-321922 p.20). 110U/310U/510U owner’s guide lists 711 with no description (im-60z101 p.46). Old T-H1 chart: 'Abnormal Gas Solenoid Valve'. Old T-KJr: 71 = 'Solenoid Gas Valve'. Green LED one flash.
Likely causes
- Break in the dark blue common wire to the high limit, OHCF and gas valves. (T-H3 service handbook, p. 19)
- Wrong gas valve harness connections. (T-H3 service handbook, p. 19)
- High-limit switch tripped or overheat cutoff fuse open. (T-H3 service handbook, pp. 19-20)
- Board and/or gas valve fault. (T-H3 service handbook, p. 20)
For a technician
- Check the high-limit switch and OHCF (less than 1 Ohm blue-blue), wiring, then 510/551 checks. (T-H2 troubleshooting guide, p. 20)
- Refer to the 111 and 121 error codes. (H-series manual (140H–540H), p. 61)
-
The heater saw a flame when there should not be one.False flame detection
The heater saw a flame when there should not be one. Takagi treats this as dangerous. (T-H3 service handbook)
By model: 110/310 red LED six flashes; TK-RE02 shows 72. Old T-KJr: 72 = 'Abnormal Burning'. Old T-H1: 721 = 'Computer Pre / Post Check Problem' (separate entry).
Likely causes
- Dirty flame sensor or cracked ceramic. (T-H3 service handbook, p. 20)
- Indoor models: condensate drain not installed on the vent collar. (110/310/510 manual, p. 48)
- Water leaking from the heat exchanger onto the flame/igniter rods. (X3P manual, p. 74)
What you can check
- Shut off all gas and power to the heater and call for service. (110/310/510 troubleshooting guide, p. 18)
For a technician
- Inspect/clean the flame sensor; check the vent-collar condensate drain and heat exchanger leaks; contact Takagi technical service. (T-H3 service handbook, p. 20)
-
The heater and the wall remote are not talking to each other.Miscommunication between water heater and remote controller
The heater and the wall remote are not talking to each other. (110/310/510 troubleshooting guide)
By model: 110/310: TK-RE02 shows 74 (no LED flash). X3P remote voltage 11-17 VDC (sh-2000585401 p.22).
Likely causes
- Remote disconnected while the heater power was on. (110/310/510 troubleshooting guide, p. 18)
- Wrong remote model, or more than one remote installed. (110/310/510 troubleshooting guide, p. 18)
- Loose wiring to the remote; power surges. (T-H3 service handbook, p. 20)
What you can check
- Check the wire connections at the remote. (110/310/510 troubleshooting guide, p. 18)
- Turn the heater off and back on to reset (X3P). (X3P manual, p. 74)
For a technician
- Check 10-25 VDC across the remote wires; replace remote if in range, board if not. (T-H3 service handbook, p. 20)
-
The heater and its own front-panel controller are not talking to each other.Miscommunication between water heater and built-in controller (indoor models)
The heater and its own front-panel controller are not talking to each other. (T-H3 service handbook)
By model: Old T-H1 chart: 'Temperature Remote control Trouble'.
Likely causes
- Loose wiring to the built-in controller; power surges. (T-H3 service handbook, p. 20)
What you can check
- Turn the heater off and back on to reset (X3P). (X3P manual, p. 74)
For a technician
- Check 11-25 VDC across the controller wires; replace controller if in range, board if not. (T-H3 service handbook, p. 20)
-
In a group of linked heaters, the main heater lost contact with one of the others.Miscommunication in Easy-Link (or Multi-Link) system
In a group of linked heaters, the main heater lost contact with one of the others. (110/310/510 manual)
By model: Shown only on the parent/master heater. Old T-H1 chart: 'Multi-system Controller'. Linked-system models only.
Likely causes
- Link wiring between parent and child units wrong or loose. (110/310/510 manual, p. 48)
- A child unit has no power (switch off, blown fuse or surge absorber). (T-H3 service handbook, p. 20)
- Power surges. (110/310/510 troubleshooting guide, p. 18)
What you can check
- Check that power is on to all heaters. (H-series manual (140H–540H), p. 61)
For a technician
- Inspect link wiring; verify power at each board; cycle the parent’s power (Easy-Link) or press Alarm Reset on the multi-unit controller. (T-H3 service handbook, pp. 20-21)
-
The exhaust got too hot, so a safety switch shut the burners off.Abnormal exhaust temperature (indoor models only)
The exhaust got too hot, so a safety switch shut the burners off. (T-H3 service handbook)
By model: Indoor models only. 140 (T-H3M) manual: check if exhaust is above 149 F (im-88a161 p.49). Green LED five flashes.
Likely causes
- Excessive vent length or blockage in intake air/exhaust. (T-H3 service handbook, p. 21)
- Dust or lint in the burner and heat exchanger. (T-H3 service handbook, p. 21)
- Incoming water above 140 F (for example a recirculation system set above 140 F). (T-H3 service handbook, p. 21)
What you can check
- Look outside for a blocked intake or exhaust. (T-H3 service handbook, p. 21)
For a technician
- Check vent length, clean burner/heat exchanger, check exhaust thermistor resistance and exhaust high-limit wiring. (T-H3 service handbook, p. 21)
-
The burner is not burning cleanly, usually from too little air or a blocked vent.Imperfect combustion (Abnormal combustion)
The burner is not burning cleanly, usually from too little air or a blocked vent. The heater shuts down. (110/310/510 troubleshooting guide)
By model: X3P: 'Combustion air and exhaust air blockage', appears during heater operation; also check the rain-tray screen and drain tube (sh-2000585401 p.15, 23). 110/310: red LED five flashes; TK-RE02 shows 99. Old T-H1 chart: 'Abnormal Burning'.
Likely causes
- Same causes as 101: blocked airway or vent, contaminated burner/fan, wrong gas type, wrong DIP settings, altitude, manifold pressure. (110/310/510 troubleshooting guide, p. 18)
- Undersized gas line, meter or regulator (more than 1 in. W.C. drop between standby and full fire). (T-H3 service handbook, p. 21)
- Flue gas recirculation: terminations too close, or another appliance’s exhaust pulled into the intake. (T-H3 service handbook, p. 22)
What you can check
- Check outside that the intake air and exhaust are not blocked. (110/310/510 manual, p. 48)
For a technician
- Verify gas type, venting, DIP settings, gas pressure; clean fan and burner. (T-H3 service handbook, pp. 21-22)
- Adjust manifold pressure only with Takagi technical support approval. (T-H3 service handbook, p. 22)
- Clear the code with the INCREASE+DECREASE reset procedure. (T-H3 service handbook, p. 22)
Commercial models: 710 and 910
T-M32 and T-M50.
-
On a T-M50, an outside fan wired to the heater’s board has a problem.Abnormal external fan motor (External fan motor failure)
On a T-M50, an outside fan wired to the heater’s board has a problem. (910 troubleshooting guide)
By model: T-M50 only.
For a technician
- Check the external fan motor connected to the central computer board. (910 troubleshooting guide, p. 18)
Discontinued models
T-H2, T-H2S, the Flash T-KJr and the T-H1. Some of their numbers mean something else than on today’s Takagi heaters.
-
On the old T-H1, 101 means the heater is not getting enough gas.Insufficient Gas Supply
On the old T-H1, 101 means the heater is not getting enough gas. (T-H1 manual)
By model: Only for the discontinued Flash T-H1. On every current Takagi, 101 is the warning before 991.
Likely causes
- Insufficient gas supply (chart wording only; no further steps given). (T-H1 manual, p. 17)
-
On the old T-H1, 211 means the vent pipe is blocked.Vent Pipe Obstruction
On the old T-H1, 211 means the vent pipe is blocked. (T-H1 manual)
By model: Discontinued T-H1 only. On X3P, 211 = air pressure sensor failure.
Likely causes
- Vent pipe obstruction (chart wording only). (T-H1 manual, p. 17)
What you can check
- Look outside for anything blocking the vent (chart names a vent pipe obstruction). (T-H1 manual, p. 17)
-
On the old T-H1, 391 points to the thermocouple.Abnormal Thermocouple
On the old T-H1, 391 points to the thermocouple. (T-H1 manual)
By model: Discontinued T-H1 only.
Likely causes
- Abnormal thermocouple (chart wording only). (T-H1 manual, p. 17)
-
On an indoor T-H2/T-H2S, the exhaust fan is not running right.Abnormal exhaust fan motor (indoor models only)
On an indoor T-H2/T-H2S, the exhaust fan is not running right. (T-H2 troubleshooting guide)
By model: Only in the T-H2/T-H2S troubleshooting guide.
Likely causes
- Broken wiring, burn marks on the board, moisture, water or debris in the fan. (T-H2 troubleshooting guide, p. 19)
For a technician
- Check wiring and fan housing; remove and inspect the exhaust fan; PCB may need replacement. (T-H2 troubleshooting guide, p. 19)
-
On the old T-H1, 651 points to the bypass valve.Abnormal Bypass Valve
On the old T-H1, 651 points to the bypass valve. (T-H1 manual)
By model: Discontinued Flash T-H1 only; do not apply to current models.
Likely causes
- Abnormal Bypass Valve (chart wording only; no steps given). (T-H1 manual, p. 17)
-
On the old T-H1, 661 points to the output (flow) adjustment valve.Abnormal Output Adjustment Valve
On the old T-H1, 661 points to the output (flow) adjustment valve. (T-H1 manual)
By model: Discontinued Flash T-H1 only; do not apply to current models.
Likely causes
- Abnormal Output Adjustment Valve (chart wording only; no steps given). (T-H1 manual, p. 17)
-
On the old T-H1, 701 points to the mixing temperature sensor.Abnormal Mixing Thermistor
On the old T-H1, 701 points to the mixing temperature sensor. (T-H1 manual)
By model: Discontinued Flash T-H1 only; do not apply to current models.
Likely causes
- Abnormal Mixing Thermistor (chart wording only; no steps given). (T-H1 manual, p. 17)
-
On the old T-H1, 721 means the board’s start-up or shut-down self-check failed.Computer Pre / Post Check Problem
On the old T-H1, 721 means the board’s start-up or shut-down self-check failed. (T-H1 manual)
By model: Discontinued Flash T-H1 only; do not apply to current models.
Likely causes
- Computer Pre / Post Check Problem (chart wording only; no steps given). (T-H1 manual, p. 17)
-
On the old T-H1, 921 is a reminder that the condensate neutralizer needs replacing.Neutralizer ‘Replacement Needed’ warning
On the old T-H1, 921 is a reminder that the condensate neutralizer needs replacing. (T-H1 manual)
By model: Discontinued Flash T-H1 only; do not apply to current models. 921/931 also appear in the X3P green-LED flash table with no meaning given (see not_found).
Likely causes
- Neutralizer ‘Replacement Needed’ warning (chart wording only; no steps given). (T-H1 manual, p. 17)
-
On the old T-H1, 931 is a condensate neutralizer error.Neutralizer error
On the old T-H1, 931 is a condensate neutralizer error. (T-H1 manual)
By model: Discontinued Flash T-H1 only; do not apply to current models. 921/931 also appear in the X3P green-LED flash table with no meaning given (see not_found).
Likely causes
- Neutralizer error (chart wording only; no steps given). (T-H1 manual, p. 17)
-
On the old Flash T-KJr remote: Gas type setting is wrong.Wrong Gas (check point)
On the old Flash T-KJr remote: Gas type setting is wrong. (Flash T-KJr manual)
By model: Old Flash T-KJr (2007) only. The newer 110 (T-KJr2)/310 (T-K4) TK-RE02 remote also shows 2-digit codes, and some numbers mean different things there (see 3-digit entries).
Likely causes
- Check point named in the chart: Wrong Gas. (Flash T-KJr manual, p. 17)
For a technician
- Check the wrong gas named in the chart. (Flash T-KJr manual, p. 17)
-
On the old Flash T-KJr remote: Control board problem.Computer Board (check point)
On the old Flash T-KJr remote: Control board problem. (Flash T-KJr manual)
By model: Old Flash T-KJr (2007) only. The newer 110 (T-KJr2)/310 (T-K4) TK-RE02 remote also shows 2-digit codes, and some numbers mean different things there (see 3-digit entries).
Likely causes
- Check point named in the chart: Computer Board. (Flash T-KJr manual, p. 17)
For a technician
- Check the computer board named in the chart. (Flash T-KJr manual, p. 17)
-
On the old Flash T-KJr remote: Gas solenoid valve problem.Solenoid Gas Valve (check point)
On the old Flash T-KJr remote: Gas solenoid valve problem. (Flash T-KJr manual)
By model: Old Flash T-KJr (2007) only. The newer 110 (T-KJr2)/310 (T-K4) TK-RE02 remote also shows 2-digit codes, and some numbers mean different things there (see 3-digit entries).
Likely causes
- Check point named in the chart: Solenoid Gas Valve. (Flash T-KJr manual, p. 17)
For a technician
- Check the solenoid gas valve named in the chart. (Flash T-KJr manual, p. 17)
-
On the old Flash T-KJr remote: Outlet temperature sensor problem.Output Thermistor (check point)
On the old Flash T-KJr remote: Outlet temperature sensor problem. (Flash T-KJr manual)
By model: Old Flash T-KJr (2007) only. The newer 110 (T-KJr2)/310 (T-K4) TK-RE02 remote also shows 2-digit codes, and some numbers mean different things there (see 3-digit entries).
Likely causes
- Check point named in the chart: Output Thermistor. (Flash T-KJr manual, p. 17)
For a technician
- Check the output thermistor named in the chart. (Flash T-KJr manual, p. 17)
-
On the old Flash T-KJr remote: Inlet temperature sensor problem.Input Thermistor (check point)
On the old Flash T-KJr remote: Inlet temperature sensor problem. (Flash T-KJr manual)
By model: Old Flash T-KJr (2007) only. The newer 110 (T-KJr2)/310 (T-K4) TK-RE02 remote also shows 2-digit codes, and some numbers mean different things there (see 3-digit entries).
Likely causes
- Check point named in the chart: Input Thermistor. (Flash T-KJr manual, p. 17)
For a technician
- Check the input thermistor named in the chart. (Flash T-KJr manual, p. 17)
-
On the old Flash T-KJr remote: Burner did not light; check the high-limit switch and igniter.Hi-limit, Igniter (check point)
On the old Flash T-KJr remote: Burner did not light; check the high-limit switch and igniter. (Flash T-KJr manual)
By model: Old Flash T-KJr (2007) only. The newer 110 (T-KJr2)/310 (T-K4) TK-RE02 remote also shows 2-digit codes, and some numbers mean different things there (see 3-digit entries).
Likely causes
- Check point named in the chart: Hi-limit, Igniter. (Flash T-KJr manual, p. 17)
For a technician
- Check the hi-limit, igniter named in the chart. (Flash T-KJr manual, p. 17)
-
On the old Flash T-KJr remote: Flame went out; check the flame sensor and high-limit switch.Flame Sensor, Hi-limit (check point)
On the old Flash T-KJr remote: Flame went out; check the flame sensor and high-limit switch. (Flash T-KJr manual)
By model: Old Flash T-KJr (2007) only. The newer 110 (T-KJr2)/310 (T-K4) TK-RE02 remote also shows 2-digit codes, and some numbers mean different things there (see 3-digit entries).
Likely causes
- Check point named in the chart: Flame Sensor, Hi-limit. (Flash T-KJr manual, p. 17)
For a technician
- Check the flame sensor, hi-limit named in the chart. (Flash T-KJr manual, p. 17)
-
On the old Flash T-KJr remote: Problem with the gas valve that adjusts the flame.Proportional Gas Valve (check point)
On the old Flash T-KJr remote: Problem with the gas valve that adjusts the flame. (Flash T-KJr manual)
By model: Old Flash T-KJr (2007) only. The newer 110 (T-KJr2)/310 (T-K4) TK-RE02 remote also shows 2-digit codes, and some numbers mean different things there (see 3-digit entries).
Likely causes
- Check point named in the chart: Proportional Gas Valve. (Flash T-KJr manual, p. 17)
For a technician
- Check the proportional gas valve named in the chart. (Flash T-KJr manual, p. 17)
-
On the old Flash T-KJr remote: The burner is not burning right.Abnormal Burning (check point)
On the old Flash T-KJr remote: The burner is not burning right. (Flash T-KJr manual)
By model: Old Flash T-KJr (2007) only. The newer 110 (T-KJr2)/310 (T-K4) TK-RE02 remote also shows 2-digit codes, and some numbers mean different things there (see 3-digit entries).
Likely causes
- Check point named in the chart: Abnormal Burning. (Flash T-KJr manual, p. 17)
For a technician
- Check the abnormal burning named in the chart. (Flash T-KJr manual, p. 17)
-
On the old Flash T-KJr remote: Fan problem.Fan (check point)
On the old Flash T-KJr remote: Fan problem. (Flash T-KJr manual)
By model: Old Flash T-KJr (2007) only. The newer 110 (T-KJr2)/310 (T-K4) TK-RE02 remote also shows 2-digit codes, and some numbers mean different things there (see 3-digit entries).
Likely causes
- Check point named in the chart: Fan. (Flash T-KJr manual, p. 17)
For a technician
- Check the fan named in the chart. (Flash T-KJr manual, p. 17)
-
On the old Flash T-KJr remote: Pressure switch problem.Pressure switch (check point)
On the old Flash T-KJr remote: Pressure switch problem. (Flash T-KJr manual)
By model: Old Flash T-KJr (2007) only. The newer 110 (T-KJr2)/310 (T-K4) TK-RE02 remote also shows 2-digit codes, and some numbers mean different things there (see 3-digit entries).
Likely causes
- Check point named in the chart: Pressure switch. (Flash T-KJr manual, p. 17)
For a technician
- Check the pressure switch named in the chart. (Flash T-KJr manual, p. 17)
No Takagi code matches that. Check the number on the display again, or look at the other brands.
Clearing a code
How to reset a Takagi, and when to stop
To clear a code
- Codes marked * (for example 111, 121, 311, 321, 611, 701, 721, 991 on the 110/310/510) clear when water flow stops. (110/310/510 manual, pp. 47-48)
- Codes marked * clear when water flow stops (111, 121, 311-391, 611, 651, 661, 701, 711, 721). (H-series manual (140H–540H), pp. 60-61)
- 111/121 automatically reset when water flow through the heater stops, or when the power is interrupted. (T-H3 service handbook, p. 14)
- Resetting the computer board: no water flowing, remote power off, power off and on, hold INC and DEC on the board until the red LED is solid, then switch power off and on. Used after fixing 101/991. (110/310/510 troubleshooting guide, pp. 13, 18, 23)
- Same computer-board reset (INC + DEC until the red LED is solid, then power off and on) after fixing 101/991 on the T-M50. (910 troubleshooting guide, pp. 13, 19, 24)
- Clear 101/991: power on, controller standby light off, hold INCREASE and DECREASE on the board 5 seconds until the green LED goes off, power off with the switch above the board, wait 5 seconds, power on. (T-H3 service handbook, p. 22)
- Clear 101/521/991 on X3P: same INCREASE+DECREASE 5-second procedure, then power off 5 seconds and on, then press On/Off on the controller. (X3P service handbook, p. 24)
- 741/751: turn the water heater OFF then ON to reset. 761: turn the parent water heater OFF then ON. (X3P manual, pp. 74-75)
- 761: Easy-Link - cycle the parent unit’s power; Multi-Link - push Alarm Reset on the multi-unit controller. (T-H3 service handbook, pp. 20-21)
- Codes marked * clear when water flow stops. (910 (T-M50) manual, pp. 44-45)
- Codes marked * clear when water flow stops. (110C/310C/510C manual, pp. 42-43)
- Codes marked * clear when water flow stops. (HX3 manual, pp. 54-55)
Takagi’s safety notes
- WHAT TO DO IF YOU SMELL GAS: do not try to light any appliance; do not touch any electric switch or use any phone in your building; call your gas supplier from a neighbor’s phone; if you cannot reach them, call the fire department. (110/310/510 manual, pp. 1, 35)
- Do not use this appliance if any part has been under water. Call a qualified installer or service agency to replace a flooded water heater; do not attempt to repair it. (110/310/510 manual, p. 35)
- Use only your hand to turn the gas shutoff valve; never use tools. If it will not turn by hand, call a qualified service technician. (110/310/510 manual, p. 35)
- Codes 510/551: if the hot water is shut off but flames are still visible through the sight glass, immediately shut off gas and power to the unit and contact technical service. (110/310/510 troubleshooting guide, p. 16)
- Code 721: First and foremost, shut off all gas and power to the unit. The problem could be the flame sensor, but if it isn’t, this is a very dangerous situation. (110/310/510 troubleshooting guide, p. 18)
- Adjusting manifold pressure can cause unexpected combustion conditions and a health hazard; not recommended without strong reason and Takagi technical service consultation. (110/310/510 troubleshooting guide, p. 23)
- Measuring inlet gas pressure: THIS IS ONLY TO BE DONE BY A LICENSED PROFESSIONAL. (110/310/510 manual, p. 43)
- Turn off electrical power and close the manual gas and water valves before servicing. (110/310/510 manual, p. 42)
- Service procedures must be performed by licensed, qualified service professionals only. The service handbook is for qualified service professionals only. (T-H3 service handbook, pp. 1, 21)
- If the high limit switch continues to trip, contact a qualified service technician. (X3P manual, p. 73)
- Water above 125 F can cause severe burns instantly or death from scalds. (110/310/510 manual, p. 36)
Heater getting old, or the same code keeps coming back? Repair or replace? Three taps and Dan’s answer → Or see what a water heater repair usually involves.
Which one do you have?
The Takagi heaters these codes cover
- 110, 310, 510 (T-KJr2, T-K4, T-D2): non-condensingT-KJr2-IN, T-KJr2-OS, T-K4-IN, T-K4-OS, T-D2-IN, T-D2-OS · 510 (T-D2): 3-digit code shown one digit at a time on the 7-segment LED on the computer board, and in full on the TM-RE30 remote. 110 (T-KJr2) and 310 (T-K4): the red LED on the computer board flashes 1 to 6 times; the optional TK-RE02 remote shows a 2-digit code (for example 32 for 321).
- 110U, 310U, 510U: ultra-low-NOx, non-condensingT-KJr2U-IN, T-KJr2U-OS, T-K4U-IN, T-K4U-OS, T-D2U-IN, T-D2U-OS · 3-digit code on the TM-RE40 remote; the green LED on the computer board blinks 1 to 6 times.
- 240, 340, 540 (T-H3J, T-H3S, T-H3) and 240H–540H: condensingT-H3J-DV, T-H3J-OS, T-H3S-DV, T-H3S-OS, T-H3-DV, T-H3-OS, 240H, 340H, 540H · 3-digit code on the built-in temperature controller (indoor) or the remote (TM-RE42); the green LED on the computer board flashes 1 to 6 times (0.5 s on, 0.5 s off, 3 s pause). Easy-Link: parent shows the code and the unit number alternately.
- 140 and 140H (T-H3M): condensingT-H3M-DV, T-H3M-OS, 140H · 3-digit code on the built-in controller (indoor) or TM-RE42 remote; green LED on the computer board flashes 1 to 6 times.
- 910 (T-M50): commercialT-M50-DV, T-M50-OS, T-M50-ASME · 3-digit code on the 7-segment LED on the center computer board (one digit at a time) and on the TM-RE30 remote; red lamps next to the 7-segment LED show whether the right or left section has the error.
- 710 (T-M32): commercialT-M32-IN, T-M32-OS, T-M32-ASME · 3-digit code on the 7-segment LED on the computer board or on the remote (if installed).
- 520 and 320 (T-H2, T-H2S): condensing, discontinuedT-H2-DV, T-H2-OS, T-H2S-DV, T-H2S-OS · 3-digit code on the 7-segment LED at the center of the computer board or on the TM-RE30 remote.
- 540P: condensing with a built-in pumpTK-540P-NIH, TK-540P-PIH, TK-540P-NEH, TK-540P-PEH · 3-digit code on the built-in controller (indoor) or TM-RE43 remote; green LED on the computer board flashes 1 to 6 times.
- 110C, 310C, 510C: concentric ventTK-110C-NI, TK-310C-NI, TK-510C-NI · 3-digit code on the built-in controller or TM-RE42 remote; green LED on the computer board flashes 1 to 6 times.
- 240HX3, 340HX3, 540HX3: condensing, X3 scale preventionTK-240X3-NIH, TK-340X3-NIH, TK-540X3-NIH, TK-240X3-NEH, TK-340X3-NEH, TK-540X3-NEH · 3-digit code on the built-in controller (indoor) or remote; green LED on the computer board flashes 1 to 6 times.
- 160X3P, 180X3P, 199X3P: condensing, X3 and a built-in pump160X3P, 180X3P, 199X3P · 3-digit code on the built-in controller or TM-RE43 remote; green LED on the computer board flashes 1 to 6 times.
- Flash T-KJr: discontinuedT-KJr · Red LED on the computer board blinks 1 to 4 times; the TK-RE02 remote shows a 2-digit code.
- Flash T-H1: discontinuedT-H1 · 3-digit code at the bottom left of the computer board or on the TM-RE30 remote.
Common questions
Takagi error code questions
What does Takagi error code 111 mean?
Ignition failure: the burner didn’t light after three tries. Takagi’s owner’s guides say to make sure the gas supply valve is fully open, check a propane tank has gas, then turn the hot water off. The code clears when the water stops flowing. If it keeps coming back, Takagi’s guides point to the gas pressure, the igniter, the flame sensor and the vent, which are a technician’s job.
How do I reset a Takagi tankless water heater?
Most Takagi codes clear on their own once you turn off the hot water and water stops flowing through the heater. Takagi’s manuals mark those codes with a star. 101 and 991 are different: they need a reset on the circuit board inside the heater after the cause is fixed. That’s a job for a technician.
What’s the difference between Takagi 101 and 991?
101 is a warning. The burner is getting too much gas for the air it has, but the heater keeps running. If the cause isn’t fixed, it becomes 991 and the heater shuts down. Takagi lists the same causes for both, starting with a blocked air intake or vent.
Where this comes from
Sources
Every meaning, cause and step on this page is from Takagi’s own documents, checked November 13, 2026. Page numbers are the printed page. We left out codes we only found on forums.
- Troubleshooting Guide, Non-Condensing Models On-Demand Water Heater: 110 (T-KJr2), 310 (T-K4), 510 (T-D2) A.O. Smith Water Products Co. (Takagi) · 321923-000 · 9/12/11 · Models: T-KJr2-IN, T-KJr2-OS, T-K4-IN, T-K4-OS, T-D2-IN, T-D2-OS
- On-Demand Water Heater Installation Manual and Owner’s Guide: 110, 310, 510 Indoor/Outdoor Takagi (A.O. Smith) · 62S051-10 / DIR 2000534765 · Rev. B · Models: T-KJr2-IN, T-KJr2-OS, T-K4-IN, T-K4-OS, T-D2-IN, T-D2-OS
- On-Demand Water Heater Installation Manual and Owner’s Guide: 110U (T-KJr2U), 310U (T-K4U), 510U (T-D2U) Takagi (A.O. Smith) · 60Z101 · not printed (PDF dated 2012) · Models: T-KJr2U-IN, T-KJr2U-OS, T-K4U-IN, T-K4U-OS, T-D2U-IN, T-D2U-OS
- On-Demand Water Heater Installation Manual and Owner’s Guide: 140H, 240H, 340H, 540H Takagi (A.O. Smith) · 68A161 (file name on takagi.com) · not printed (PDF dated Aug 2021) · Models: 140H, 240H, 340H, 540H, T-H3-DV/OS, T-H3J-DV/OS, T-H3S-DV/OS
- Condensing Models On-Demand Water Heater Service Handbook: 240 (T-H3J), 340 (T-H3S), 540 (T-H3), Series 100/101 A.O. Smith Water Products Co. (Takagi) · DIR 2000534342 · Rev. A, October 2016 · Models: T-H3J-DV, T-H3J-OS, T-H3S-DV, T-H3S-OS, T-H3-DV, T-H3-OS
- On-Demand Water Heater Installation Manual and Owner’s Guide: 140 Indoor / 140 Outdoor (T-H3M) Takagi (A.O. Smith) · 88A161-5 · not printed (PDF dated Feb 2017) · Models: T-H3M-DV, T-H3M-OS
- Condensing Models On-Demand Water Heater Service Handbook (ATI/ATO-140H, GTS-140, GT-140, T-H3M) A.O. Smith Water Products Co. (Takagi) · 100267626 · January 2016 · Models: T-H3M-DV-NG, T-H3M-DV-LP, T-H3M-OS-NG, T-H3M-OS-LP
- On-Demand Water Heater Installation Manual and Owner’s Guide: 910 / 910 ASME (T-M50) Takagi (A.O. Smith) · 63V051-9 / DIR 2000534709 · Rev. B · Models: T-M50, T-M50-ASME
- Troubleshooting Guide 910 / 910 ASME (T-M50 / T-M50 ASME) On-Demand Water Heater A.O. Smith Water Products Co. (Takagi) · 321925-000 · 9/12/11 · Models: T-M50, T-M50-ASME
- Troubleshooting Guide 710 / 710 ASME (T-M32 / T-M32 ASME) On-Demand Water Heater A.O. Smith Water Products Co. (Takagi) · 321924-000 · 9/12/11 · Models: T-M32, T-M32-ASME
- Troubleshooting Guide, Condensing Models On-Demand Water Heater: 520 (T-H2), 320 (T-H2S) A.O. Smith Water Products Co. (Takagi) · 321922-000 · 9/12/11 · Models: T-H2-DV, T-H2-OS, T-H2S-DV, T-H2S-OS
- On-Demand Water Heater Installation Manual and Owner’s Guide: 540P Indoor / 540P Outdoor Takagi (A.O. Smith) · 2000536265 · Rev. B · Models: TK-540P-NIH, TK-540P-PIH, TK-540P-NEH, TK-540P-PEH
- On-Demand Water Heater Installation Manual and Owner’s Guide: 110C, 310C, 510C Takagi (A.O. Smith) · DIR 2000535218 · Rev. B · Models: TK-110C-NI, TK-310C-NI, TK-510C-NI
- On-Demand Water Heater Installation Manual and Owner’s Guide: 240HX3, 340HX3, 540HX3 Takagi (A.O. Smith) · 2000599585 · Rev. B (printed on p. 64) · Models: TK-240X3, TK-340X3, TK-540X3
- On-Demand Water Heater Installation Manual and Owner’s Guide: 160X3P, 180X3P, 199X3P Takagi (A.O. Smith) · 2000570774 · Rev. B · Models: 160X3P, 180X3P, 199X3P
- Condensing Models On-Demand Water Heater Service Handbook: 160X3P, 180X3P, 199X3P (Series 100) Takagi (A.O. Smith) · DIR 2000585401 · Rev. B, March 2020 · Models: 160X3P, 180X3P, 199X3P
- T-KJr. Instantaneous Water Heater Installation Manual and Owner’s Guide Takagi Industrial Co. USA · not printed · file dated 4-17-2007 · Models: T-KJr
- T-H1 Instantaneous Appliance Installation Manual and Owner’s Guide Takagi Industrial Co. USA · M-001-TH1-0 · not printed · Models: T-H1
- takagi.com Support > Manuals and Troubleshooting Guides pages (model-to-document links) Takagi (A.O. Smith) · checked 2026-11-13