Rheem · Error code 13 · Checked November 2026

Rheem tankless error code 13: poor combustion, then lockout

On Rheem’s earlier tankless heaters, 13 is poor combustion followed by a lockout. Rheem’s current manuals list 13 but don’t explain it.

Smell gas? Don’t touch any switch or try to reset anything. Leave the house, then call 911 or your gas company from outside. In Southern California that’s SoCalGas, 1-800-427-2200.

Dan and Dave of Dan's Plumbing in front of their work truck

From Dan and Dave at Dan's Plumbing, a family plumbing shop in Westlake Village, California. Everything below comes from Rheem’s own documents, cited line by line.

What it means

What Rheem says code 13 means

“Indoor units ONLY. Flame rod is detecting poor combustion. This is commonly caused by inadequate GAS SUPPLY and/or VENTING.”— Tankless Gas Troubleshooting Pocket Manual SVC 820P - For Non-Condensing & Condensing Platforms, page 49

On Rheem’s earlier tankless heaters, code 13 means the second flame rod sees poor combustion, and it only happens on indoor units. Rheem’s service manual says the usual cause is low gas supply or a venting problem. After 5 shutdowns in 4 hours, the heater locks out until a technician resets it.

On today’s “-3” and RTG-R models, Rheem’s troubleshooting manuals list 13 only among the “hard lockout” codes in their reset steps, which are written for technicians. They don’t say what causes it, and we won’t guess.

Model differences. On the current '-3' and RTG-R platforms, 13 appears only in the list of hard lockouts in the reset procedure (AP21822 p. 61; AP24838 p. 56); those manuals give no description of it.

Why it happens

Likely causes of Rheem code 13

What to do

Safe checks first. Then call a pro.

Safe checks you can do

  1. Do the owner reset steps; if the code is still displayed, contact a dealer or qualified service technician. (AP16115 tankless manual (2012), pp. 25-26)

To clear the code:

What a technician checks, and why

  • Check gas supply and venting; check DIP2 altitude setting.Static and dynamic gas pressure are measured with a manometer at the heater’s gas connection (NG 4.0-10.5 in. W.C., LP 8.0-13.0 in. W.C.). (SVC 820P tankless service manual, p. 49)
  • Reseat connector T; check flame rod status in maintenance mode (0Y); clean or replace flame rods; remove and clean the manifold and burner; check gas supply, venting and ground.Requires removing the front cover and testing or replacing internal parts (control board, sensors, valves, connectors) with a meter; the troubleshooting manual is written for qualified technicians only. (SVC 820P tankless service manual, pp. 49-50)
  • After 5 shutdowns in 4 hours, perform the hard-lockout reset.Requires removing the front cover and testing or replacing internal parts (control board, sensors, valves, connectors) with a meter; the troubleshooting manual is written for qualified technicians only. (SVC 820P tankless service manual, pp. 27, 49)

Please don’t

  • Don’t open the burner, the gas valve or the sealed combustion chamber.
  • Don’t keep resetting a code that keeps coming back. A code that returns means the cause is still there.
  • Don’t bypass or unplug a safety sensor to get hot water back.
  • Don’t cover, tape or move the vent or the air intake.

Heater getting old, or the same code keeps coming back? Repair or replace? Three taps and Dan’s answer → Or see what a water heater repair usually involves.

Where this comes from

Sources

Taken from Rheem’s own documents, checked November 13, 2026. Page numbers are the printed page. Where models differ, we say which model each part applies to.

  1. Tankless Gas Troubleshooting Pocket Manual SVC 820P - For Non-Condensing & Condensing Platforms Rheem Manufacturing Company · SVC-820P · REV 3 (printed 05/19) · Models: Non-condensing 64DV/X, 70DV/X, 84DV/X, 95DV/X, 150DV/X, 160DV/X, 180DV/X, 200DV/X, 2-20R, 2-25R, 2-28R, Condensing (up to -2 models) H-68, H-84, H-90, H-95, H-160, H-180, H-200, H-25R, H-32R
  2. Tankless Water Heater Use and Care Manual With Installation Instructions for the Installer - Noncondensing 199,900, 180,000 and 150,000 Btu/hr Models Rheem Manufacturing Company · AP16115-1 · (8/12) · Models: 2012-era non-condensing 150k-199.9k Btu/hr (model numbers not printed)
  3. High and Super High Efficiency Tankless Water Heater Troubleshooting Manual Rheem Manufacturing Company, Water Heater Division · AP21822 · Rev 02 (Copyright 2025) · Models: RTGH-68/84/90/95 DV(E)L(N/P)-3, RUTGH-..-3, ECOH160/180/200..-3, RMTGH..-3, RTG-70/84/95 DV(E)L / X(E)L (N/P)-3, RUTG-..-3, ECO160/180/200..-3, RMTG..-3
  4. High Efficiency Tankless Water Heater with Recirculation Troubleshooting Manual Rheem Manufacturing Company, Water Heater Division · AP24838 · Rev 01 (Copyright 2025) · Models: RTG-R70/R95 DVEL(N/P)-3 and XEL(N/P)-3, RUTG-R..-3, ECOR160/200..-3, RMTGR..-3, FDTG-R..-3

Water heater help

More about water heaters

Dan standing in front of his white work truck, smiling

Code won’t clear?

If you’re within about 30 miles of Westlake Village, call or text Dan a photo of the display and the label. He’ll tell you what it is.

Or send the details and Dan will call you back. Monday to Friday, 9am – 5pm.

Find us

Dan's Plumbing

2352 Hillsbury Rd
Westlake Village, CA 91361

(805) 330-3111 · Monday to Friday, 9am – 5pm

Serving Westlake Village, Thousand Oaks, Agoura Hills, Oak Park and Lake Sherwood. Zip codes 91361, 91362, 91360, 91320, 91301, 91377, 91302, 90265.

Dan (left) and Dave. Family run since 1977. One of them does the work.