Rinnai · Error code 79 · Checked November 2026

Rinnai error code 79: a water leak inside

The heater’s leak sensor found water in the bottom of the cabinet. Turn off the water to the heater and call a pro.

Smell gas? Don’t touch any switch or try to reset anything. Leave the house, then call 911 or your gas company from outside. In Southern California that’s SoCalGas, 1-800-427-2200.

Dan and Dave of Dan's Plumbing in front of their work truck

From Dan and Dave at Dan's Plumbing, a family plumbing shop in Westlake Village, California. Everything below comes from Rinnai’s own documents, cited line by line.

What it means

What Rinnai says code 79 means

“Water has been detected at the bottom of the unit. Turn off water supply.”— Direct Vent Tankless Water Heater Installation and Operation Manual — Value Series (V94i, V94Xi, V75i, V65i, V94e, V75e, V65e), page 35

Code 79 means the heater’s leak sensor found water in the bottom of the cabinet. Rinnai’s manual says to turn off the water supply and contact a licensed professional.

The water can come from a leak in the heat exchanger or a pipe inside the heater. Rinnai also says condensation in very humid spots can set off a false 79, and it makes a shorter sensing element for that.

Rinnai lists code 79 for its RE, REP and V series heaters and the older Ultra models. It isn’t in the newest SENSEI manuals.

Model differences. Listed in Value, RE/REP and KB (2012, RU80/RU98) owner tables; not in the 2017 KBD table. Demand Duo R-Series also lists 79 (Demand Duo manual p. 46).

Why it happens

Likely causes of Rinnai code 79

What to do

Safe checks first. Then call a pro.

Safe checks you can do

  1. Turn off the water supply and contact a licensed professional. (RE manual, p. 51)

What a technician checks, and why

  • Check leak-detector wiring; check heat exchanger and internal piping for leaks; dry the cabinet and sensor and restart.Requires removing the front cover and working inside the cabinet. (Diagnostic codes guide (2024), p. 62)
  • If no water is found, unplug the sensor and fire the heater; if it runs, replace sensor and screw.Live electrical testing inside the unit; Rinnai says only trained and qualified professionals should do it. (Diagnostic codes guide (2024), p. 62)
  • For nuisance codes from humidity, install the modified (shorter) sensing element.Requires removing the front cover and working inside the cabinet. (Bulletin TB-101, p. 1)

Please don’t

  • Don’t open the burner, the gas valve or the sealed combustion chamber.
  • Don’t keep resetting a code that keeps coming back. A code that returns means the cause is still there.
  • Don’t bypass or unplug a safety sensor to get hot water back.
  • Don’t cover, tape or move the vent or the air intake.

Heater getting old, or the same code keeps coming back? Repair or replace? Three taps and Dan’s answer → Or see what a water heater repair usually involves.

Common questions

Rinnai code 79 questions

Can I keep using my Rinnai with code 79?

Rinnai’s manual says to turn off the water supply and contact a licensed professional. Water inside the cabinet can come from a leak in the heater itself.

Where this comes from

Sources

Taken from Rinnai’s own documents, checked November 13, 2026. Page numbers are the printed page. Where models differ, we say which model each part applies to.

  1. Direct Vent Tankless Water Heater Installation and Operation Manual — Value Series (V94i, V94Xi, V75i, V65i, V94e, V75e, V65e) Rinnai America Corporation · 100000258 / U307-1120X04 · (10) · Models: V94i, V94Xi, V75i, V65i, V94e, V75e, V65e
  2. Troubleshooting Tankless Water Heater Diagnostic Codes Rinnai America Corporation · 100000652 · file '100000652-Troubleshooting TWH Diagnostic Codes (3).pdf', PDF dated 2024-05-08; byte-identical to the library’s 'TWH Troubleshooting Technical Data Sheet' · Models: RU/RUR/RSC/CU SENSEI, RX/RXP/CX/CXP SENSEI RX/CX, RE/REP (VE), V53e/V53De/V65/V75/V94/V94X (VC Value), RL75/RL94/RLX94 (VC Luxury, VB), R50LS/R63LS/R75LS/R94LS/R98LS (VA), RC80/RC98 (KA), RU80/RU90/RU98, RUC80/90/98, C199 (KB/KBD), RUR98 (KBP), RUCS65/75, RUS65/75 (KCM), RH180 (HTT)
  3. Technical Bulletin 101 — Code 79 Sensing Element Rinnai America Corporation · TB-101 · ©2013 · Models: Non-SENSEI models with leak sensor (library tags V75i)
  4. Installation and Operation Manual — RE Models (RE199/RE180/RE160/RE140 i/e, VE platform) Rinnai America Corporation · 100000722 · (03) · Models: RE199i, RE180i, RE160i, RE140i, RE199e, RE180e, RE160e, RE140e

Water heater help

More about water heaters

Dan standing in front of his white work truck, smiling

Code won’t clear?

If you’re within about 30 miles of Westlake Village, call or text Dan a photo of the display and the label. He’ll tell you what it is.

Or send the details and Dan will call you back. Monday to Friday, 9am – 5pm.

Find us

Dan's Plumbing

2352 Hillsbury Rd
Westlake Village, CA 91361

(805) 330-3111 · Monday to Friday, 9am – 5pm

Serving Westlake Village, Thousand Oaks, Agoura Hills, Oak Park and Lake Sherwood. Zip codes 91361, 91362, 91360, 91320, 91301, 91377, 91302, 90265.

Dan (left) and Dave. Family run since 1977. One of them does the work.