Rinnai · Error code 79 · Checked November 2026
Rinnai error code 79: a water leak inside
The heater’s leak sensor found water in the bottom of the cabinet. Turn off the water to the heater and call a pro.
Smell gas? Don’t touch any switch or try to reset anything. Leave the house, then call 911 or your gas company from outside. In Southern California that’s SoCalGas, 1-800-427-2200.
From Dan and Dave at Dan's Plumbing, a family plumbing shop in Westlake Village, California. Everything below comes from Rinnai’s own documents, cited line by line.
What it means
What Rinnai says code 79 means
“Water has been detected at the bottom of the unit. Turn off water supply.”— Direct Vent Tankless Water Heater Installation and Operation Manual — Value Series (V94i, V94Xi, V75i, V65i, V94e, V75e, V65e), page 35
Code 79 means the heater’s leak sensor found water in the bottom of the cabinet. Rinnai’s manual says to turn off the water supply and contact a licensed professional.
The water can come from a leak in the heat exchanger or a pipe inside the heater. Rinnai also says condensation in very humid spots can set off a false 79, and it makes a shorter sensing element for that.
Rinnai lists code 79 for its RE, REP and V series heaters and the older Ultra models. It isn’t in the newest SENSEI manuals.
Model differences. Listed in Value, RE/REP and KB (2012, RU80/RU98) owner tables; not in the 2017 KBD table. Demand Duo R-Series also lists 79 (Demand Duo manual p. 46).
Why it happens
Likely causes of Rinnai code 79
- Leaking heat exchanger or internal piping, water pooled in the cabinet, or a faulty leak sensor. (Diagnostic codes guide (2024), p. 62)
- Condensation in very humid locations can cause nuisance 79s; Rinnai offers a shorter sensing element. (Bulletin TB-101, p. 1)
What to do
Safe checks first. Then call a pro.
Safe checks you can do
Turn off the water supply and contact a licensed professional. (RE manual, p. 51)
What a technician checks, and why
- Check leak-detector wiring; check heat exchanger and internal piping for leaks; dry the cabinet and sensor and restart.Requires removing the front cover and working inside the cabinet. (Diagnostic codes guide (2024), p. 62)
- If no water is found, unplug the sensor and fire the heater; if it runs, replace sensor and screw.Live electrical testing inside the unit; Rinnai says only trained and qualified professionals should do it. (Diagnostic codes guide (2024), p. 62)
- For nuisance codes from humidity, install the modified (shorter) sensing element.Requires removing the front cover and working inside the cabinet. (Bulletin TB-101, p. 1)
Please don’t
- Don’t open the burner, the gas valve or the sealed combustion chamber.
- Don’t keep resetting a code that keeps coming back. A code that returns means the cause is still there.
- Don’t bypass or unplug a safety sensor to get hot water back.
- Don’t cover, tape or move the vent or the air intake.
Heater getting old, or the same code keeps coming back? Repair or replace? Three taps and Dan’s answer → Or see what a water heater repair usually involves.
Common questions
Rinnai code 79 questions
Can I keep using my Rinnai with code 79?
Rinnai’s manual says to turn off the water supply and contact a licensed professional. Water inside the cabinet can come from a leak in the heater itself.
Where this comes from
Sources
Taken from Rinnai’s own documents, checked November 13, 2026. Page numbers are the printed page. Where models differ, we say which model each part applies to.
- Direct Vent Tankless Water Heater Installation and Operation Manual — Value Series (V94i, V94Xi, V75i, V65i, V94e, V75e, V65e) Rinnai America Corporation · 100000258 / U307-1120X04 · (10) · Models: V94i, V94Xi, V75i, V65i, V94e, V75e, V65e
- Troubleshooting Tankless Water Heater Diagnostic Codes Rinnai America Corporation · 100000652 · file '100000652-Troubleshooting TWH Diagnostic Codes (3).pdf', PDF dated 2024-05-08; byte-identical to the library’s 'TWH Troubleshooting Technical Data Sheet' · Models: RU/RUR/RSC/CU SENSEI, RX/RXP/CX/CXP SENSEI RX/CX, RE/REP (VE), V53e/V53De/V65/V75/V94/V94X (VC Value), RL75/RL94/RLX94 (VC Luxury, VB), R50LS/R63LS/R75LS/R94LS/R98LS (VA), RC80/RC98 (KA), RU80/RU90/RU98, RUC80/90/98, C199 (KB/KBD), RUR98 (KBP), RUCS65/75, RUS65/75 (KCM), RH180 (HTT)
- Technical Bulletin 101 — Code 79 Sensing Element Rinnai America Corporation · TB-101 · ©2013 · Models: Non-SENSEI models with leak sensor (library tags V75i)
- Installation and Operation Manual — RE Models (RE199/RE180/RE160/RE140 i/e, VE platform) Rinnai America Corporation · 100000722 · (03) · Models: RE199i, RE180i, RE160i, RE140i, RE199e, RE180e, RE160e, RE140e
Water heater help
More about water heaters
Code won’t clear?
If you’re within about 30 miles of Westlake Village, call or text Dan a photo of the display and the label. He’ll tell you what it is.
Or send the details and Dan will call you back. Monday to Friday, 9am – 5pm.