Rheem and Ruud: tankless, gas tanks and heat pumps · 148 codes · Checked November 2026
Rheem and Ruud error codes, in plain words
Ruud is part of Rheem, and Ruud tankless heaters are covered by the same Rheem manuals. Gas tanks with a status light blink a count, power-vent tanks flash a pattern and can show a number, and tankless heaters show a two-digit code. Here’s every one in Rheem’s manuals, in plain words. The same number means different things on a tank and a tankless, so start with what you have.
From Dan and Dave at Dan's Plumbing, a family plumbing shop in Westlake Village, California. Every line below comes from Rheem’s own documents, with the page it’s on.
Smell gas? Don’t touch any switch or try to reset anything. Leave the house, then call 911 or your gas company from outside. In Southern California that’s SoCalGas, 1-800-427-2200.
Every code
All 148 Rheem codes
Gas tanks with a status light
Standard Rheem and Ruud gas tanks: the light next to the gas control knob. One blue blink every 3 seconds is normal. Red blinks are codes. Ultra Low NOx tanks add 9 and 10 red blinks.
-
The status light is dark.STATUS LIGHT CODE: OFF
The status light is dark. The gas control is turned off, the pilot is out, or the pilot’s thermopile is not making enough power to run the light. (AP23060 gas tank manual, p. 24)
By model: Same chart in the Ultra Low NOx manuals (AP23699 p. 24, AP23698 p. 24).
Likely causes
- Combination gas control turned off. (AP23060 gas tank manual, p. 24)
- Pilot not lit. (AP23060 gas tank manual, p. 24)
- Insufficient power supply (millivoltage) from the thermopile. (AP23060 gas tank manual, p. 24)
What you can check
- Turn the gas control on following the operating instructions in the Use & Care manual. (AP23060 gas tank manual, p. 24)
- Relight the pilot using the lighting instructions on the heater and in the manual (smell for gas first; remove only the outer door). (AP23060 gas tank manual, pp. 17, 24)
For a technician
- Check the thermopile connector at the combination gas control; check the thermopile wires for damage and replace if needed; inspect the pilot assembly. (AP23060 gas tank manual, p. 24)
- If the pilot will not stay lit after several attempts, turn the knob OFF and call a technician (disconnected or defective thermopile, defective safety magnet, or opened single-use gas shut-off device in the gas control are listed causes). (AP23060 gas tank manual, pp. 17, 22)
-
The light stays on without blinking.STATUS LIGHT CODE: Constantly lit
The light stays on without blinking. The pilot just went out and is cooling down, or the knob was just turned to OFF. (AP23060 gas tank manual, p. 24)
Likely causes
- Pilot recently went out and the thermopile is cooling down. (AP23060 gas tank manual, p. 24)
- Temperature knob recently turned to OFF. (When the knob is turned OFF with the pilot lit, the light stays lit briefly and changes from blue to red.) (AP23060 gas tank manual, p. 24)
What you can check
- Relight the pilot using the lighting instructions on the heater and in the Use & Care manual. (AP23060 gas tank manual, pp. 17, 24)
-
Normal.1 BLUE - Normal Operation; One (1) blink every three (3) seconds
Normal. The pilot is lit. If the burner never comes on, the knob may still be on PILOT. (AP23060 gas tank manual, p. 24)
Likely causes
- Normal operation. (AP23060 gas tank manual, p. 24)
- Temperature knob left in the PILOT position with the pilot lit. (AP23060 gas tank manual, p. 24)
What you can check
- Set the temperature knob on the combination gas control to the desired setting. (AP23060 gas tank manual, p. 24)
-
The pilot is lit, but the thermopile (the part the pilot heats to make power for the gas control) is making too little voltage.2 RED - Thermopile Voltage Low
The pilot is lit, but the thermopile (the part the pilot heats to make power for the gas control) is making too little voltage. (AP23060 gas tank manual, p. 24)
Likely causes
- Low thermopile voltage while the pilot is lit. (AP23060 gas tank manual, p. 24)
For a technician
- Check the thermopile connector at the combination gas control is properly connected; check the thermopile wires for damage and replace if needed; inspect the pilot assembly. (AP23060 gas tank manual, p. 24)
-
The water got too hot and the high-temperature safety limit shut the heater off.4 RED - High Temperature Shutdown
The water got too hot and the high-temperature safety limit shut the heater off. (AP23060 gas tank manual, p. 24)
By model: The same manual says the gas control has a single-use gas shut-off device that shuts off the burner if the water exceeds normal operating temperatures (p. 19), and that a technician must replace the gas control if that device has opened (p. 22). The status chart itself does not link the two.
Likely causes
- High water temperature limit tripped. (AP23060 gas tank manual, p. 24)
For a technician
- Contact a qualified service technician. (AP23060 gas tank manual, p. 24)
-
The gas control’s water temperature sensor has failed.5 RED - Temperature Sensor Failure
The gas control’s water temperature sensor has failed. (AP23060 gas tank manual, p. 24)
Likely causes
- Water temperature sensor failure. (AP23060 gas tank manual, p. 24)
For a technician
- Contact a qualified service technician. (AP23060 gas tank manual, p. 24)
-
The gas control valve itself has failed.7 RED - Gas Control or Valve Failure
The gas control valve itself has failed. (AP23060 gas tank manual, p. 24)
Likely causes
- Combination gas control (thermostat) failure. (AP23060 gas tank manual, p. 24)
For a technician
- Contact a qualified service technician. (AP23060 gas tank manual, p. 24)
-
The control sees a pilot flame signal when it should not.8 RED - Flame Sense Error
The control sees a pilot flame signal when it should not. (AP23060 gas tank manual, p. 24)
Likely causes
- False pilot flame signal. (AP23060 gas tank manual, p. 24)
For a technician
- Contact a qualified service technician. (AP23060 gas tank manual, p. 24)
-
Ultra Low NOx models only: the sensor that watches the combustion chamber has failed or tripped.9 RED - Chamber Sensor Failure
Ultra Low NOx models only: the sensor that watches the combustion chamber has failed or tripped. (AP23699 Ultra Low NOx tank manual, p. 24)
By model: Only in the Ultra Low NOx (SCAQMD Rule 1121) manuals AP23699, AP23698, AP22858, AP20849. Not in the standard atmospheric chart (AP23060). AP20849 (XG75 high demand) adds 'or bimetal switch activated'.
Likely causes
- Chamber sensor failure. (AP23699 Ultra Low NOx tank manual, p. 24)
- Chamber sensor failure (Professional Classic Ultra Low NOx). (AP23698 Professional Classic ULN manual, p. 24)
- Chamber sensor failure (high-BTU Ultra Low NOx). (AP22858 Ultra Low NOx tank manual, p. 23)
- High-demand Ultra Low NOx model: chamber sensor failure or bimetal switch activated. (AP20849 Ultra Low NOx 75-gal manual, p. 24)
For a technician
- Contact a qualified service technician. (AP23699 Ultra Low NOx tank manual, p. 24)
-
Ultra Low NOx models only: the combustion chamber got too hot and the heater shut down.10 RED - Chamber Temperature Shutdown
Ultra Low NOx models only: the combustion chamber got too hot and the heater shut down. (AP23699 Ultra Low NOx tank manual, p. 24)
By model: Only in the Ultra Low NOx manuals (AP23699, AP23698, AP22858, AP20849). These manuals also say the heater has a combustion shut-off device that trips on flammable vapors or blocked combustion air openings (p. 22), but the status chart does not tie that to 10 blinks.
Likely causes
- Chamber temperature shutdown. (AP23699 Ultra Low NOx tank manual, p. 24)
- Chamber temperature shutdown (Professional Classic Ultra Low NOx). (AP23698 Professional Classic ULN manual, p. 24)
- Chamber temperature shutdown (high-BTU Ultra Low NOx). (AP22858 Ultra Low NOx tank manual, p. 23)
- Chamber temperature shutdown (high-demand Ultra Low NOx). (AP20849 Ultra Low NOx 75-gal manual, p. 24)
For a technician
- Contact a qualified service technician. (AP23699 Ultra Low NOx tank manual, p. 24)
Power-vent gas tanks
The light on the gas control flashes a pattern every 3 seconds, like “6 flashes of 2.” Models with a display also show a number, listed as LCD.
-
Normal standby.Gas Valve LED Codes: Short flash once every four seconds - None
Normal standby. No fault. (AP22510 power-vent manual, p. 37)
Likely causes
- No problem (LCD code: none; solution: none required). (AP22510 power-vent manual, p. 37)
- Idle: no call for heat, no fault; temperature setpoint reached and burner is off (2009 manual wording). (AP14818 power-vent manual (2009), p. 36)
-
Normal.Gas Valve LED Codes: “Heartbeat”, alternates bright/dim - None
Normal. The heater is heating (calling for heat) with no fault. (AP22510 power-vent manual, p. 37)
Likely causes
- No problem (LCD code: none; solution: none required). (AP22510 power-vent manual, p. 37)
- Call for heat, no fault; water is below setpoint and burner is on (2009 manual wording). (AP14818 power-vent manual (2009), p. 36)
-
The control sees a weak pilot flame.Low flame signal
The control sees a weak pilot flame. It keeps running (2009 manual), but the pilot or gas supply needs attention. (AP22510 power-vent manual, p. 37)
Likely causes
- Gas supply pressure is too low. (AP22510 power-vent manual, p. 37)
- Low voltage to the water heater. (AP22510 power-vent manual, p. 37)
- Pilot tube restriction, carbon build-up on the electrode, pilot wire damage or gas supply (2009 manual). (AP14818 power-vent manual (2009), p. 36)
For a technician
- Increase the inlet gas supply pressure. (AP22510 power-vent manual, p. 37)
- Increase supply voltage to the rated voltage. (AP22510 power-vent manual, p. 37)
- Replace the pilot assembly. (AP22510 power-vent manual, p. 37)
-
The blower’s pressure switch is stuck closed before the blower starts, so the control will not light.Pressure switch failed closed.
The blower’s pressure switch is stuck closed before the blower starts, so the control will not light. (AP22510 power-vent manual, p. 37)
Likely causes
- Pressure switch failed closed. (AP22510 power-vent manual, p. 37)
- Pressure switch tube blockage or faulty pressure switch (2009 manual). (AP14818 power-vent manual (2009), p. 36)
For a technician
- Verify the wiring to the blower pressure switch is correct and connected properly. (AP22510 power-vent manual, p. 37)
- Replace the blower assembly (2009 manual: replace the pressure switch). (AP22510 power-vent manual, p. 37)
-
The blower’s pressure switch or its heat switch did not close.Pressure and/or blower thermal switch failed open.
The blower’s pressure switch or its heat switch did not close. Often the vent is blocked or the blower is not working right. (AP22510 power-vent manual, p. 37)
Likely causes
- Pressure switch and/or blower thermal switch failed open. (AP22510 power-vent manual, p. 37)
- Vent blockage or improper installation, switch tube blockage, faulty switch, blower not working properly, or temperature switch open (2009 manual). (AP14818 power-vent manual (2009), p. 36)
What you can check
- Look at the outdoor vent terminal and the air inlet openings for blockage or obstructions (the manual’s routine maintenance tells the user to check the outdoor vent terminal). (AP22510 power-vent manual, pp. 32, 37)
For a technician
- Verify the wiring to the blower pressure switch and thermal switch is correct and connected properly. (AP22510 power-vent manual, p. 37)
- Check the vent system for blockage or obstructions. (AP22510 power-vent manual, p. 37)
- Replace the blower assembly (2009 manual: replace pressure switch, blower temperature switch, or blower). (AP22510 power-vent manual, p. 37)
-
The temperature cut-off (TCO, the over-temperature safety) has tripped.TCO activated.
The temperature cut-off (TCO, the over-temperature safety) has tripped. (AP22510 power-vent manual, p. 37)
Likely causes
- TCO (thermal cut-off) activated. (AP22510 power-vent manual, p. 37)
- Thermal well fault, gas control fault, or tank not filled with water (2009 manual). (AP14818 power-vent manual (2009), p. 36)
What you can check
- Make sure the tank is full of water. (AP22510 power-vent manual, p. 37)
For a technician
- Reset the TCO and check for proper combination gas control (thermostat) cycling. (AP22510 power-vent manual, p. 37)
-
The control sees flame when it should not.Flame out of sequence
The control sees flame when it should not. A gas valve may be stuck open. (AP22510 power-vent manual, p. 37)
By model: The 2009 manual (AP14818-1 p. 36) prints 'Four Flash, three second pause' for LCD 14 as well as for LCD 31; the current manuals (AP22510/AP22511 p. 37) give five flashes for LCD 14. Trust the LCD number if the unit has a display.
Likely causes
- Flame out of sequence. (AP22510 power-vent manual, p. 37)
- Pilot or burner valve has failed open (2009 manual). (AP14818 power-vent manual (2009), p. 36)
For a technician
- Replace the combination gas control (thermostat). (AP22510 power-vent manual, p. 37)
-
Lockout: the heater tried to light and could not.System in lockout. Failed trial for ignitions.
Lockout: the heater tried to light and could not. (AP22510 power-vent manual, p. 37)
Likely causes
- Gas supply is off or too low to operate. (AP22510 power-vent manual, p. 37)
- Insufficient gas supply, unstable pilot, carbon buildup on the electrode, or wire/pilot tube damage (2009 manual). (AP14818 power-vent manual (2009), p. 36)
What you can check
- Make sure the gas supply is turned on (manual gas shut-off valve open). (AP22510 power-vent manual, p. 37)
For a technician
- Increase the inlet gas supply pressure. (AP22510 power-vent manual, p. 37)
- Replace the pilot assembly. (AP22510 power-vent manual, p. 37)
- Replace the combination gas control (thermostat). (AP22510 power-vent manual, p. 37)
-
Lockout: the blower pressure switch or heat switch kept opening.System in lockout. Blower pressure switch and/or thermal switch open.
Lockout: the blower pressure switch or heat switch kept opening. Usually a vent or blower problem. (AP22510 power-vent manual, p. 37)
Likely causes
- Blower pressure switch and/or thermal switch open. (AP22510 power-vent manual, p. 37)
- Vent blockage or improper installation, switch tube blockage, faulty switch, blower problem, blower temperature switch open, or excessive wind at the vent termination (2009 manual). (AP14818 power-vent manual (2009), p. 36)
What you can check
- Look at the outdoor vent terminal and air inlet openings for blockage or obstructions. (AP22510 power-vent manual, pp. 32, 37)
For a technician
- Verify wiring to the blower pressure switch and thermal switch is correct and connected properly. (AP22510 power-vent manual, p. 37)
- Check the vent system for blockage or obstructions; check vent termination compliance with the manual (2009 manual). (AP22510 power-vent manual, p. 37)
- Replace the blower assembly. (AP22510 power-vent manual, p. 37)
-
Lockout: the flame lit but kept going out.System in lockout. Flame lost.
Lockout: the flame lit but kept going out. (AP22510 power-vent manual, p. 37)
Likely causes
- Gas supply pressure is too low. (AP22510 power-vent manual, p. 37)
- Blocked combustion air-inlet openings around the jacket. (AP22510 power-vent manual, p. 37)
- Pilot tube restriction, low gas pressure, carbon on the electrode, wire/pilot tube damage, or combustion air port blockage (2009 manual). (AP14818 power-vent manual (2009), p. 36)
What you can check
- Check the combustion air-inlet openings around the water heater jacket for blockage or obstructions (lint, dirt). (AP22510 power-vent manual, pp. 32, 37)
For a technician
- Increase the inlet gas supply pressure. (AP22510 power-vent manual, p. 37)
- Replace the pilot assembly. (AP22510 power-vent manual, p. 37)
-
Lockout: flame was sensed when the valve should be closed.System in lockout. Flame sense out of sequence.
Lockout: flame was sensed when the valve should be closed. The valve may be stuck open. (AP22510 power-vent manual, p. 37)
Likely causes
- Flame sensed out of sequence; valve stuck in open position (2009 manual: 'Soft Lockout'). (AP14818 power-vent manual (2009), p. 36)
For a technician
- Replace the combination gas control (thermostat). (AP22510 power-vent manual, p. 37)
-
Lockout: several ignition attempts failed.System in lockout. Failed Ignition attempts.
Lockout: several ignition attempts failed. (AP22510 power-vent manual, p. 37)
By model: Not in the 2009 manual (AP14818-1); only in the current power vent manuals.
Likely causes
- Gas supply is off or too low to operate. (AP22510 power-vent manual, p. 37)
What you can check
- Make sure the gas supply is turned on (manual gas shut-off valve open). (AP22510 power-vent manual, p. 37)
For a technician
- Increase the inlet gas supply pressure. (AP22510 power-vent manual, p. 37)
- Replace the pilot assembly. (AP22510 power-vent manual, p. 37)
- Replace the combination gas control (thermostat). (AP22510 power-vent manual, p. 37)
-
Lockout: the flammable vapor sensor smelled gasoline or other flammable vapors (or the sensor failed).System in lockout. Flammable vapor sensor.
Lockout: the flammable vapor sensor smelled gasoline or other flammable vapors (or the sensor failed). The heater will not restart on its own. (AP22510 power-vent manual, p. 37)
Likely causes
- The flammable vapor sensor detected flammable vapors (gasoline, some paints/stains/thinners, vent pipe cement and solvents, bleach touching the sensor). (AP22510 power-vent manual, pp. 31, 37)
- The sensor has failed (2009 manual). (AP14818 power-vent manual (2009), p. 36)
What you can check
- Verify that no gasoline or flammable vapors are present; clear any hazardous materials and ventilate the area. (AP22510 power-vent manual, pp. 3, 37)
- Do NOT turn off the appliance or move the ON/OFF switch; contact a qualified service technician. (AP22510 power-vent manual, p. 3)
For a technician
- Reset the combination gas control (thermostat). (AP22510 power-vent manual, pp. 3, 37)
- Replace the flammable vapor sensor. (AP22510 power-vent manual, p. 37)
-
The flammable vapor sensor or its wiring has a fault.Flammable vapor sensor, fault detected.
The flammable vapor sensor or its wiring has a fault. (AP22510 power-vent manual, p. 37)
Likely causes
- Flammable vapor sensor fault. (AP22510 power-vent manual, p. 37)
- Sensor resistance out of range, faulty sensor wiring, or faulty control (2009 manual). (AP14818 power-vent manual (2009), p. 36)
For a technician
- Replace the flammable vapor sensor. (AP22510 power-vent manual, p. 37)
- Replace the combination gas control (thermostat). (AP22510 power-vent manual, p. 37)
-
The tank temperature sensor (thermal well) or its wiring has a fault.Temperature sensor fault detected.
The tank temperature sensor (thermal well) or its wiring has a fault. (AP22510 power-vent manual, p. 37)
Likely causes
- Temperature sensor (thermal well) fault. (AP22510 power-vent manual, p. 37)
For a technician
- Check the wiring connections between the combination gas control and the thermal well. (AP22510 power-vent manual, p. 37)
- Replace the thermal well of the combination gas control. (AP22510 power-vent manual, p. 37)
-
The gas control’s electronics found an internal fault.Electronics fault detected.
The gas control’s electronics found an internal fault. (AP22510 power-vent manual, p. 37)
Likely causes
- Electronics fault; thermal well fault or gas control fault (2009 manual). (AP14818 power-vent manual (2009), p. 36)
For a technician
- Replace the combination gas control (thermostat). (AP22510 power-vent manual, p. 37)
- Replace the thermal well of the combination gas control. (AP22510 power-vent manual, p. 37)
-
The gas control found a fault in itself.Combination gas control (thermostat) fault detected.
The gas control found a fault in itself. It may need a power reset or replacement. (AP22510 power-vent manual, p. 37)
Likely causes
- Gas control valve needs to be reset or has been damaged (2009 manual). (AP14818 power-vent manual (2009), p. 36)
What you can check
- Cycle power to the combination gas control (thermostat). (AP22510 power-vent manual, p. 37)
For a technician
- Replace the combination gas control (thermostat). (AP22510 power-vent manual, p. 37)
Tankless: current “-3” models and RTG-R
RTG, RTGH, the ECO and ECOH, Ruud RUTG and RUTGH, and the RTG-R with a built-in pump. A two-digit code on the front display.
-
Not enough hot water is flowing through the heater for it to turn on.P1 Error Code – Not enough water flow for operation (old manuals: P1 Warning Code)
Not enough hot water is flowing through the heater for it to turn on. It needs at least 0.4 gallons per minute. (AP21822 tankless troubleshooting manual, p. 34)
By model: Same meaning on all three platforms. IKONIC shows this as T113.
Likely causes
- Not enough water flow (minimum 0.4 GPM to activate). (AP21822 tankless troubleshooting manual, p. 34)
- Debris in the heat exchanger or the water inlet filter. (AP21822 tankless troubleshooting manual, p. 34)
- Blocked water flow sensor in the water control valve. (AP21822 tankless troubleshooting manual, p. 34)
- Plumbing cross-over in the home (hot and cold mixing at a fixture). (AP21822 tankless troubleshooting manual, p. 34)
- Recirculation pump in the line (if installed); low flow during a recirculation cycle on RTG-R models. (AP23962 RTG-R manual, p. 74)
- Hot and cold water lines crossed at the heater. (SVC 820P tankless service manual, p. 32)
What you can check
- Increase the water flow from the fixtures (open the hot tap more). (AP21820 condensing tankless manual, p. 75)
- Make sure the water shut-off valve is fully open and the hot faucet is fully open. (AP21820 condensing tankless manual, p. 72)
- Clean the fixture aerator screens. (AP21820 condensing tankless manual, p. 72)
- Clean the water inlet filter (the owner’s manual says to check and clean it monthly). (AP21820 condensing tankless manual, pp. 66-68, 72)
- RTG-R: confirm there is no debris caught in the inlet water filter and increase the water flow from fixtures. (AP23962 RTG-R manual, p. 74)
For a technician
- Check the flow rate in maintenance mode 1Y with hot taps running; if above 0.4 GPM and the unit does not fire, replace the control board. (AP21822 tankless troubleshooting manual, p. 34)
- Remove the water control valve and clean the water flow sensor. (AP21822 tankless troubleshooting manual, p. 34)
- Test for a plumbing cross-over by closing the heater’s hot valve and opening each fixture’s hot side. (AP21822 tankless troubleshooting manual, p. 34)
- Flush the heat exchanger (see 1L). (AP21822 tankless troubleshooting manual, pp. 34-35)
- Recirculation lines: check pump size, aquastat, check valve and operation. (SVC 820P tankless service manual, p. 32)
-
Scale (lime) is building up inside the heat exchanger.1L Warning Code – Lime build-up detected in heat exchanger
Scale (lime) is building up inside the heat exchanger. The heater must be drained and flushed to prevent permanent damage. (AP21822 tankless troubleshooting manual, p. 34)
By model: IKONIC shows lime build-up as A01L (owner’s manual) / A018 (service manual).
Likely causes
- Water heater has buildup of lime deposits. (AP21820 condensing tankless manual, p. 75)
- Lime and scale build-up inside the heat exchanger; may need repeat flushing for heavy scale. (AP21822 tankless troubleshooting manual, p. 34)
What you can check
- Contact a dealer or qualified service technician (RTG-R manual adds: flushing the water heater is recommended). (AP23962 RTG-R manual, p. 74)
For a technician
- Flush: gas off, cold and hot valves off, power cycled and unplugged; hoses on the service valves; circulate 2 gallons of food-grade white vinegar with a submersible pump for 45-60 minutes; drain; rinse with cold water about 5 minutes; clean the inlet filter; purge air; restore power and gas. (AP21822 tankless troubleshooting manual, pp. 34-35)
- Reset the 1L code by holding the MIN and MAX buttons on the control board together for 10 seconds. (AP21822 tankless troubleshooting manual, p. 34)
-
Only on two or more heaters linked together.03 Error Code – Manifold setting failure
Only on two or more heaters linked together. One heater cannot talk to the lead (manager) heater or the manifold controller. (AP21822 tankless troubleshooting manual, p. 35)
Likely causes
- Connection cable between water heaters and the manifold controller (EZ-Link, MIC-6 or MIC-185). (AP21822 tankless troubleshooting manual, p. 35)
- DIP switch setting on the control board (DIP1 switch #4 must be ON on every unit). (AP21822 tankless troubleshooting manual, p. 35)
For a technician
- Turn gas, water and power off to all units; remove and reinsert the connecting cables; set DIP1 switch #4 ON on all units; restore power; on MIC-6/MIC-185 wait for solid LEDs; retest. If 03 remains, call Rheem technical support (800) 432-8373. (AP21822 tankless troubleshooting manual, p. 35)
-
Warning: the heat exchanger is reading colder than it should while the heater runs.05 Warning Code – Low heat exchanger temperature detected
Warning: the heat exchanger is reading colder than it should while the heater runs. If it keeps happening, the heater shows error 28. (AP21822 tankless troubleshooting manual, p. 35)
By model: Different meaning on the earlier platform: see the separate 05 entry for tankless-legacy.
Likely causes
- Inlet thermistor, heat exchanger thermistor, proportional gas valve or water valve. (AP21822 tankless troubleshooting manual, p. 35)
For a technician
- Measure resistance at connector C between #4 (black) and #5 (yellow): 7K-23K ohms; check the heat exchanger thermistor at the yellow Molex; clean scale off the thermistor or replace it; replace the harness or control board as the chart directs. Check gas valve and water valve per codes 32, 65 and 66. (AP21822 tankless troubleshooting manual, pp. 35-36)
-
The heat exchanger kept reading too cold after a 05 warning, so the heater stopped with error 28.28 Error Code – Low heat exchanger temperature detected
The heat exchanger kept reading too cold after a 05 warning, so the heater stopped with error 28. (AP21822 tankless troubleshooting manual, p. 35)
By model: Recirculation models: same section in AP24838 pp. 28-29.
Likely causes
- Inlet thermistor, heat exchanger thermistor, proportional gas valve or water valve. (AP21822 tankless troubleshooting manual, p. 35)
For a technician
- Same checks as 05: thermistor resistance 7K-23K ohms at connector C (#4/#5), clean or replace the heat exchanger thermistor, harness or control board. (AP21822 tankless troubleshooting manual, pp. 35-36)
-
Not enough air is moving through the heater.10 Warning Code – Incorrect inlet air volume
Not enough air is moving through the heater. It may have been run before the vent was connected, the vent may be blocked, or the fan is weak. It is a 'hard lockout' that needs a technician reset. (AP21822 tankless troubleshooting manual, p. 37)
By model: Listed as a 'warning code' but it is one of the three hard lockouts (10, 13, 99) that need the DIP-switch reset (AP21822 p. 61; SVC 820P p. 27).
Likely causes
- Venting disconnected or termination blocked (intake or exhaust side). (AP21822 tankless troubleshooting manual, p. 37)
- Blower motor not creating enough ventilation. (AP21822 tankless troubleshooting manual, p. 37)
What you can check
- Look at the vent and air intake terminations outside for blockage. (AP21822 tankless troubleshooting manual, p. 37)
For a technician
- Reconnect vents or clean the terminations (both inlet and exhaust). (AP21822 tankless troubleshooting manual, p. 37)
- Check the blower motor as for code 61. (AP21822 tankless troubleshooting manual, p. 37)
- Earlier platform: do the reset first, then remove, clean and reinstall the blower motor and housing; test blower voltages at connector G (indoor 144-192 VDC, 12-18 VDC, 4-10 VDC). (SVC 820P tankless service manual, pp. 38-40)
- Hard-lockout reset at the control board DIP switches (DIP1 #2, then MIN + MAX until 'UL'). (AP21822 tankless troubleshooting manual, p. 61)
-
The heater tried to light but did not sense a flame.11 Error Code – Flame Not Detected by Flame Rod
The heater tried to light but did not sense a flame. (AP21822 tankless troubleshooting manual, p. 37)
By model: '-3' models try ignition 2 times before showing 11 (AP21822 p. 37). Earlier indoor models have 2 flame rods (SVC 820P p. 43). IKONIC equivalent is A011 (10 attempts).
Likely causes
- The gas shut-off valve is not fully opened. (AP21820 condensing tankless manual, p. 75; AP22009 RTG tankless manual, p. 77)
- Gas supply pressure, blocked gas filter, venting, igniter rod or flame rod. (AP21822 tankless troubleshooting manual, p. 37)
- Commonly gas supply and/or venting; also gas control valve (earlier platform). (SVC 820P tankless service manual, p. 41)
What you can check
- Check the gas shut-off valve and open it completely. (AP21820 condensing tankless manual, p. 75)
- Look at the vent termination outside for blockage. (AP21822 tankless troubleshooting manual, p. 37)
For a technician
- Check static and dynamic gas pressure at the heater’s gas connection (NG 4.0-10.5 in. W.C., LP 8.0-13.0 in. W.C.). (AP21822 tankless troubleshooting manual, p. 37)
- Clean the gas filter at the gas connection. (AP21822 tankless troubleshooting manual, p. 37)
- Check DIP switches for venting and altitude. (AP21822 tankless troubleshooting manual, p. 37)
- No spark: reseat igniter connectors; 108-132 VAC on connector O while igniting; clean or replace igniter rod and coil. (AP21822 tankless troubleshooting manual, p. 38)
- Spark but no flame signal: check flame rod status (0Y), clean or replace the flame rod; test gas valve solenoids (10-50 ohms, 5-15 VDC; inlet solenoid 11-17 VDC); replace gas valve or control board. (AP21822 tankless troubleshooting manual, p. 39)
-
The flame lit, then went out, three times in a row.12 Error Code – Detected Presence of Flame, Then Lost it
The flame lit, then went out, three times in a row. (AP21822 tankless troubleshooting manual, p. 40)
By model: IKONIC equivalent A012 counts 15 consecutive flame losses.
Likely causes
- Gas service has been interrupted. (AP21820 condensing tankless manual, p. 75)
- LP gas is running low (LP models only). (AP21820 condensing tankless manual, p. 75)
- Gas supply pressure, gas filter, venting or flame rod. (AP21822 tankless troubleshooting manual, p. 40)
What you can check
- If gas service was interrupted, contact your gas utility company. (AP21820 condensing tankless manual, p. 75)
- LP models: refill or replace the LP gas container. (AP21820 condensing tankless manual, p. 75)
For a technician
- Check static and dynamic gas pressure; clean the gas filter; check venting and DIP switches. (AP21822 tankless troubleshooting manual, p. 40)
- Check flame rod status (0Y), clean or replace the flame rod; test gas valve solenoids; replace gas valve or control board. (AP21822 tankless troubleshooting manual, p. 40)
-
The overheat safety limit has tripped or broken.14 Error Code – Over heat limiter is active
The overheat safety limit has tripped or broken. Rheem says this is usually caused by the wrong gas supply or venting. (AP21822 tankless troubleshooting manual, p. 41)
By model: AP21822 says to replace the whole unit if the OHL resistance is out of range. The RTG-R owner’s manual calls the OHL a 'protective overheating wrap' (AP23962 p. 74).
Likely causes
- Over Heat Limiter (OHL) activated or broken; normally caused by inadequate/wrong gas supply and/or venting. (AP21822 tankless troubleshooting manual, p. 41)
- Water heater is overheating. (AP21820 condensing tankless manual, p. 75)
- RTG-R owner’s manual: protective overheating wrap has been broken. (AP23962 RTG-R manual, p. 74)
- Earlier condensing models: over temp limit switch (monitors vent temperature) can also cause 14. (SVC 820P tankless service manual, p. 51)
For a technician
- Inspect the OHL for damage; reseat connector C (RTG-R: connector E) and the purple OHL Molex; measure OHL resistance 50K-500K ohms; if not, replace the unit; if yes, replace the control board. (AP21822 tankless troubleshooting manual, p. 41)
- Check gas supply and venting. (SVC 820P tankless service manual, p. 51)
-
Water inside the heater got hotter than 207°F for over 15 seconds.15 Error Code – Excessively hot water detected
Water inside the heater got hotter than 207°F for over 15 seconds. (AP21822 tankless troubleshooting manual, p. 42)
Likely causes
- Gas supply pressure, venting, heat exchanger thermistor, outlet thermistor, or sediment build-up in the heat exchanger. (AP21822 tankless troubleshooting manual, p. 42)
- The heat exchanger is too hot (earlier owner’s manual). (AP16115 tankless manual (2012), p. 26)
What you can check
- Check for blockage in the vent; then contact a dealer or qualified service technician. (AP16115 tankless manual (2012), p. 26)
For a technician
- Check gas pressure and venting; test heat exchanger and outlet thermistors (codes 32, 33); flush the heat exchanger (see 1L). (AP21822 tankless troubleshooting manual, p. 42)
-
The hot water leaving the heater is hotter than the temperature set on the display.16 Error Code – Outlet thermistor failure
The hot water leaving the heater is hotter than the temperature set on the display. (AP21822 tankless troubleshooting manual, p. 42)
Likely causes
- Outlet thermistor (check it first) or water bypass valve. (AP21822 tankless troubleshooting manual, p. 42)
For a technician
- Test the outlet thermistor (see 33), then the bypass valve (see 66). (AP21822 tankless troubleshooting manual, p. 42)
-
A button on the display or remote was held for more than 20 seconds, or is stuck.24 Error Code – DIP switch malfunction
A button on the display or remote was held for more than 20 seconds, or is stuck. (AP21822 tankless troubleshooting manual, p. 43)
By model: AP21822 titles 24 'DIP switch malfunction' but the explanation is about buttons held over 20 seconds.
Likely causes
- Display or remote buttons pressed more than 20 seconds; remote wiring damage. (AP21822 tankless troubleshooting manual, p. 43)
What you can check
- Release the buttons and operate the unit. (SVC 820P tankless service manual, p. 55)
For a technician
- Inspect remote wiring; unplug the unit, disconnect and reconnect the remote wires; if 24 returns, replace the built-in controller or remote. (AP21822 tankless troubleshooting manual, p. 43)
-
Condensing models: acidic condensate water is not draining out of the heater’s built-in trap.29 Error Code – Condensation not drained from collector
Condensing models: acidic condensate water is not draining out of the heater’s built-in trap. (AP21822 tankless troubleshooting manual, p. 43)
By model: Condensing models only (RTGH/ECOH '-3'; H-series earlier). On earlier models SVC 820P calls this '29 (A)' and also has a different '29 (B)' (see next entry).
Likely causes
- Neutralizer is clogged. (AP21820 condensing tankless manual, p. 75)
- Protection plug not removed from the drain connection at the bottom of the unit. (AP21822 tankless troubleshooting manual, p. 43)
- Condensate drain line blocked or pinched; unnecessary P-trap in the drain line. (AP21822 tankless troubleshooting manual, p. 43)
What you can check
- Check that the condensate drain line is not blocked, pinched or frozen; the manual says a blocked drain must be cleared. (AP21820 condensing tankless manual, pp. 41, 68)
For a technician
- Remove the protection plug from the condensate connection; remove any P-trap from the drain line. (AP21822 tankless troubleshooting manual, p. 43)
- Replace a clogged or depleted condensate neutralizer (owner’s manual: contact a dealer or qualified service technician). (AP21820 condensing tankless manual, pp. 68, 75)
-
The cold-water inlet temperature sensor has failed or is reading wrong.31 Error Code – Inlet thermistor malfunction
The cold-water inlet temperature sensor has failed or is reading wrong. (AP21822 tankless troubleshooting manual, p. 44)
Likely causes
- Faulty inlet thermistor. (AP21820 condensing tankless manual, p. 75)
For a technician
- Measure 7K-23K ohms at connector C (#4 black, #7 white); check the white Molex; clean scale from the thermistor; replace water valve, harness or control board as the chart directs. (AP21822 tankless troubleshooting manual, p. 44)
-
The heat exchanger temperature sensor has failed or is reading wrong.32 Error Code – Heat exchanger thermistor malfunction
The heat exchanger temperature sensor has failed or is reading wrong. (AP21822 tankless troubleshooting manual, p. 45)
By model: Earlier platform: condensing units measure #3 black to #5 green on connector R (SVC 820P p. 61).
Likely causes
- Heat exchanger thermistor. (AP21822 tankless troubleshooting manual, p. 45)
For a technician
- Measure 7K-23K ohms at connector C (#4 black, #5 yellow); check the yellow Molex; clean scale or replace the heat exchanger thermistor; replace harness or control board as the chart directs. (AP21822 tankless troubleshooting manual, p. 45)
-
The hot-water outlet temperature sensor has failed or is reading wrong.33 Error Code – Outlet thermistor malfunction
The hot-water outlet temperature sensor has failed or is reading wrong. (AP21822 tankless troubleshooting manual, p. 46)
Likely causes
- Faulty outlet thermistor. (AP21820 condensing tankless manual, p. 75)
For a technician
- Measure 7K-23K ohms at connector C (#3 red, #4 black); check the black Molex; clean scale or replace the outlet thermistor; replace harness or control board as the chart directs. (AP21822 tankless troubleshooting manual, p. 46)
-
The air (ambient) temperature sensor has failed or is reading wrong.34 Error Code – Ambient/air supply thermistor malfunction
The air (ambient) temperature sensor has failed or is reading wrong. (AP21822 tankless troubleshooting manual, p. 47)
By model: Earlier platform ('Ambient thermistor malfunction'): 64DV/84DV/95DV read 7K-23K ohms; 64X/84X/95X/H95X/H95DV read 2K-72K ohms (SVC 820P p. 65).
Likely causes
- Inlet air (ambient) thermistor. (AP21822 tankless troubleshooting manual, p. 47)
For a technician
- Measure 7K-23K ohms at connector C (#4 black, #6 blue); check the blue Molex; clean debris or replace the ambient thermistor; replace harness or control board. (AP21822 tankless troubleshooting manual, p. 47)
-
One of the temperature sensors is loose or plugged into the wrong spot.35 Error Code – Improper thermistor connection
One of the temperature sensors is loose or plugged into the wrong spot. (AP21822 tankless troubleshooting manual, p. 48)
By model: Earlier platform has four thermistors (adds ambient) (SVC 820P p. 67); '-3' manual lists three.
Likely causes
- Inlet, outlet or heat exchanger thermistor with a poor connection or in the wrong location. (AP21822 tankless troubleshooting manual, p. 48)
For a technician
- Reseat connector C and each thermistor Molex (inlet white, outlet black, heat exchanger yellow); if 35 persists, test all thermistors (31, 32, 33). (AP21822 tankless troubleshooting manual, p. 48)
-
Flame is still sensed a few seconds after the heater shut off.51 Error Code – Main gas solenoid valve (SV) malfunction
Flame is still sensed a few seconds after the heater shut off. A gas valve may not be closing all the way. (AP21822 tankless troubleshooting manual, p. 49)
Likely causes
- Flame rod or proportional gas valve. (AP21822 tankless troubleshooting manual, p. 49)
- Gas control valve malfunction: flame present when hot water demand ended and the unit turned off (earlier platform). (SVC 820P tankless service manual, p. 68)
For a technician
- Reseat connectors D and G; watch the burner through the sight glass while cycling the unit ON-OFF 3 times at 10-second intervals; if flame is visible while off more than 5 seconds, replace the proportional gas valve; otherwise clean or replace the flame rod or replace the control board. (AP21822 tankless troubleshooting manual, p. 49)
-
The proportional (modulating) gas valve that adjusts the flame size is not working right.52 Error Code – Proportional gas valve malfunction
The proportional (modulating) gas valve that adjusts the flame size is not working right. (SVC 820P tankless service manual, p. 71)
By model: In AP21822 p. 50 and AP24838 p. 43 the 52 'Explanation' paragraph repeats the code-51 wording (flame detected after turning off), but the heading and test steps are for the proportional gas valve. Meaning quote taken from SVC 820P p. 71.
Likely causes
- Proportional gas valve; flame rod. (AP21822 tankless troubleshooting manual, p. 50)
- PGFR (Proportional Gas Flow Regulator), the modulating valve in the gas control valve (earlier platform). (SVC 820P tankless service manual, p. 71)
For a technician
- Reseat connector D and the red/black Molex on the gas valve; while igniting, check 1.5-14 VDC at connector D (#8 black, #9 red) and at the valve; replace control board, harness or gas control valve as the chart directs. (AP21822 tankless troubleshooting manual, p. 50)
-
The combustion fan is not spinning at the right speed.61 Error Code – Blower motor speed incorrect for combustion
The combustion fan is not spinning at the right speed. (AP21822 tankless troubleshooting manual, p. 51)
By model: The 2012 owner’s manuals group '61 or 99' as 'Faulty blower motor' (AP16115-1 p. 26).
Likely causes
- Faulty blower motor. (AP21820 condensing tankless manual, p. 75)
- Blower motor RPM signal incorrect. (AP21822 tankless troubleshooting manual, p. 51)
For a technician
- Reseat connector K and the blower connector; check 144-192 VDC (#6/#4), 12-18 VDC and pulsing 4-10 VDC (outdoor units use different wire colors); replace control board and/or blower motor. Do NOT touch meter leads across #1 and #3. (AP21822 tankless troubleshooting manual, p. 51)
-
Recirculation models: the built-in pump is not running at the right speed.63 Error Code – Recirculation pump speed incorrect
Recirculation models: the built-in pump is not running at the right speed. (AP24838 RTG-R troubleshooting manual, p. 45)
By model: Only on built-in recirculation models (RTG-R/ECOR '-3'). IKONIC SR uses A063 with a different definition.
Likely causes
- There is an abnormality in the pump’s operation. (AP23962 RTG-R manual, p. 74)
- Recirculation pump RPM signal incorrect. (AP24838 RTG-R troubleshooting manual, p. 45)
What you can check
- Remove any blockage that would prevent the pump from flowing water, then contact a dealer or qualified service technician. (AP23962 RTG-R manual, p. 74)
For a technician
- Reseat connector B; check 145-195 VDC and 12-18 VDC; if 63 continues, replace the recirculation pump and control board. (AP24838 RTG-R troubleshooting manual, p. 45)
-
The motorized water valve that limits how much water flows through the heater is not working.65 Error Code – Water motor failed (earlier: water volume control valve malfunction)
The motorized water valve that limits how much water flows through the heater is not working. (AP24838 RTG-R troubleshooting manual, p. 46)
By model: The '-3' manual AP21822 names '65 Error Code: Water motor failed' (p. 35) but has no 65 section; full steps are in AP24838 and SVC 820P.
Likely causes
- Water volume control valve. (AP24838 RTG-R troubleshooting manual, p. 46)
- Faulty water flow solenoid (2012 owner’s manual). (AP16115 tankless manual (2012), p. 26)
For a technician
- Reseat connector D; check 4-16 VDC and pulsing 4-10 VDC while water flows and the unit tries to ignite; replace the water valve assembly or control board. (AP24838 RTG-R troubleshooting manual, p. 46)
- Earlier platform: the valve only activates when hot water demand exceeds the unit’s limit, so test under high demand. (SVC 820P tankless service manual, p. 77)
-
The bypass valve, which blends cold water in to control the outlet temperature, is not working.66 Error Code – Bypass motor failed
The bypass valve, which blends cold water in to control the outlet temperature, is not working. (AP21822 tankless troubleshooting manual, p. 52)
Likely causes
- Faulty bypass motor. (AP21820 condensing tankless manual, p. 75)
For a technician
- Reseat connector N; check voltages at connector N while water flows; replace the water valve assembly or control board. (AP21822 tankless troubleshooting manual, p. 52)
- Earlier platform: set the temperature to 102°F so the bypass valve activates before measuring voltage. (SVC 820P tankless service manual, p. 79)
-
The control board’s computer chip is not working.70 Error Code – Microcomputer abnormality
The control board’s computer chip is not working. (AP21822 tankless troubleshooting manual, p. 53)
Likely causes
- Control board. (AP21822 tankless troubleshooting manual, p. 53)
What you can check
- Turn power off and back on (owner reset steps). (AP21820 condensing tankless manual, p. 74)
For a technician
- Turn power off and on; if 70 appears again, replace the control board. (AP21822 tankless troubleshooting manual, p. 53)
-
The gas valve’s shut-off solenoid circuit has a problem.71 Error Code – Solenoid valve (SV) circuit failure
The gas valve’s shut-off solenoid circuit has a problem. (AP21822 tankless troubleshooting manual, p. 54)
By model: AP21820 p. 75's solution for 71 also says 'Flushing procedure may need to be repeated for excessive lime and scale build-up', which looks copied from the 1L row.
Likely causes
- Solenoid valve circuit failure. (AP21820 condensing tankless manual, p. 75)
- Gas control valve malfunction (inlet solenoid) (earlier platform). (SVC 820P tankless service manual, p. 80)
For a technician
- Reseat connector D and the display Molex; inspect solenoid wiring; check 11-17 VDC at connector D (#1 yellow, #4 black); replace the manifold assembly and gas valve, or the control board. (AP21822 tankless troubleshooting manual, p. 54)
-
The flame sensor sees flame before the igniter even sparks.72 Error Code – Flame rod detected flame before ignition
The flame sensor sees flame before the igniter even sparks. (AP21822 tankless troubleshooting manual, p. 55)
Likely causes
- Flame rod or proportional gas valve. (AP21822 tankless troubleshooting manual, p. 55)
For a technician
- Reseat connector G and the flame rod terminal; power-cycle and watch through the sight glass; if flame shows before the spark, replace the proportional gas valve; otherwise clean or replace the flame rod, or replace the control board. (AP21822 tankless troubleshooting manual, p. 55)
-
The display or remote cannot talk to the heater’s control board.76 Error Code – Built-in display (or remote controller) to water heater comm. failure
The display or remote cannot talk to the heater’s control board. (AP21822 tankless troubleshooting manual, p. 56)
Likely causes
- Built-in controller or remote controller, or their wiring. (AP21822 tankless troubleshooting manual, p. 56)
What you can check
- Models with a wall remote: look for loose or damaged remote control wiring. (AP21822 tankless troubleshooting manual, p. 57)
For a technician
- Reseat connector A (built-in display) or F (remote) and the display Molex; check 2-5 VDC; replace the built-in display/remote or the control board. (AP21822 tankless troubleshooting manual, pp. 56-57)
-
The fan motor is drawing the wrong amount of electrical current.79 Error Code – Blower motor current failure
The fan motor is drawing the wrong amount of electrical current. (AP21822 tankless troubleshooting manual, p. 58)
Likely causes
- Blower motor. (AP21822 tankless troubleshooting manual, p. 58)
For a technician
- Reseat connector K; remove the blower (three screws) and clean the blower and housing; check 144-192 VDC, 12-18 VDC and pulsing 4-10 VDC; replace control board or blower motor. (AP21822 tankless troubleshooting manual, p. 58)
-
Flame is still sensed after the gas valves closed.80 Error Code - Detected flame presence after closing solenoid valves
Flame is still sensed after the gas valves closed. (AP21822 tankless troubleshooting manual, p. 59)
Likely causes
- Flame rod or solenoid valves. (AP21822 tankless troubleshooting manual, p. 59)
- Gas control valve malfunction (earlier platform). (SVC 820P tankless service manual, p. 92)
For a technician
- Check the flame rod (as for code 12) and the solenoid valves (as for code 51). (AP21822 tankless troubleshooting manual, p. 59)
-
The gas-type chip on the control board is loose, wrong, or bad.82 Error Code – Installed chip error
The gas-type chip on the control board is loose, wrong, or bad. (AP21822 tankless troubleshooting manual, p. 59)
Likely causes
- Gas chip on the control board. (AP21822 tankless troubleshooting manual, p. 59)
- Control board program chip malfunction (earlier platform). (SVC 820P tankless service manual, p. 95)
For a technician
- Confirm the correct gas chip is installed; remove and reinsert it; replace with a new gas chip. (AP21822 tankless troubleshooting manual, p. 59)
-
A maintenance reminder is due (set for 500, 750 or 1,000 burner hours): flush the heat exchanger and/or replace the water treatment filter.88 Error Code – Maintenance notice
A maintenance reminder is due (set for 500, 750 or 1,000 burner hours): flush the heat exchanger and/or replace the water treatment filter. If ignored, the heater will eventually shut down. (AP21822 tankless troubleshooting manual, p. 2)
By model: The reminder is off by default and set in maintenance mode 1Y / 8A (AP21820 p. 76). IKONIC uses T111.
Likely causes
- Reminder of flushing the heat exchanger and/or replacing the water treatment filter. (AP21820 condensing tankless manual, p. 75)
- This is a warning code and the unit will eventually shut down to protect itself. (AP21822 tankless troubleshooting manual, p. 60)
What you can check
- After maintenance is done, clear 88: remote ON; close gas and water shut-off valves; press DOWN to the lowest setting; hold DOWN and UP 5-10 seconds; reopen the valves. (AP21820 condensing tankless manual, p. 77)
- Contact a dealer or qualified service technician for the flush. (AP21820 condensing tankless manual, p. 75)
For a technician
- Drain and flush the heat exchanger (see 1L). (AP21822 tankless troubleshooting manual, p. 60)
-
The exhaust got too hot and a limit switch tripped.89 Error Code – High exhaust temperature detected
The exhaust got too hot and a limit switch tripped. Rheem says this is usually a gas supply or venting problem. (AP21822 tankless troubleshooting manual, p. 1)
By model: AP24838 (non-condensing recirculation models) uses the same text, including 'secondary heat exchanger' (p. 56).
Likely causes
- Over temperature limit switch on the secondary heat exchanger activated; normally caused by inadequate/wrong gas supply and/or venting. (AP21822 tankless troubleshooting manual, p. 61)
For a technician
- Check the over temperature limit switch, gas supply and venting. (AP21822 tankless troubleshooting manual, p. 61)
-
The heater found a blocked vent before lighting.90 Error Code - Blockage in venting detected (before unit goes to ignition)
The heater found a blocked vent before lighting. (AP21822 tankless troubleshooting manual, p. 61)
Likely causes
- Air intake or vent exhaust opening may be blocked. (AP21820 condensing tankless manual, p. 75)
- The vent pipes on the vent termination may not be connected properly. (AP21820 condensing tankless manual, p. 75)
- Unit operated before vent installation, or blockage detected during pre-purge. (AP21822 tankless troubleshooting manual, p. 61)
What you can check
- Remove any blockage from the air intake and vent exhaust (the air intake needs 12 in. [30 cm] of clearance). (AP21820 condensing tankless manual, p. 75)
For a technician
- Reconnect vent pipes at the termination. (AP21820 condensing tankless manual, p. 75)
- Check vent materials, terminations, lengths, spacing (exhaust recirculation), sealing, fan speed (maintenance mode), and pull and clean the blower. (SVC 820P tankless service manual, p. 97)
-
The heater found a blocked vent after it shut off (during the fan’s post-purge).99 Error Code - Blockage in venting detected (after unit shut down)
The heater found a blocked vent after it shut off (during the fan’s post-purge). This is a hard lockout that needs a technician reset. (AP21822 tankless troubleshooting manual, p. 61)
By model: The 2012 owner’s manuals list '61 or 99' as 'Faulty blower motor' (AP16115-1 p. 26, AP15897-1 p. 26), while the service manuals define 99 as a venting blockage after shutdown.
Likely causes
- Air intake or vent exhaust opening may be blocked. (AP21820 condensing tankless manual, p. 75)
- The vent pipes on the vent termination may not be connected properly. (AP21820 condensing tankless manual, p. 75)
- Unit operated before vent installation, or blockage detected during post-purge. (AP21822 tankless troubleshooting manual, p. 61)
What you can check
- Remove any blockage from the air intake and vent exhaust (the air intake needs 12 in. [30 cm] of clearance). (AP21820 condensing tankless manual, p. 75)
For a technician
- Hard-lockout reset at the control board (DIP1 #2, then MIN + MAX until 'UL'). (AP21822 tankless troubleshooting manual, p. 61)
- Check vent materials, terminations, lengths, spacing, sealing, fan speed, and pull and clean the blower. (SVC 820P tankless service manual, p. 97)
-
WiFi models: the leak sensor inside the heater found water.17 Error Code – Water leak detected
WiFi models: the leak sensor inside the heater found water. (AP21822 tankless troubleshooting manual, p. 62)
By model: Only when the WiFi controller is used.
Likely causes
- Leak from the heat exchanger or water valve. (AP21822 tankless troubleshooting manual, p. 62)
- Condensation build-up in the cabinet or condensation entering from the intake venting. (AP21822 tankless troubleshooting manual, p. 62)
What you can check
- There is a potential water leak; contact a dealer or qualified service technician. (AP23962 RTG-R manual, p. 74)
For a technician
- With power off and water flowing, look inside for the leak; replace the water valve, or replace the water heater if the heat exchanger pipe leaks; otherwise dry the sensor and look for external leak sources. (AP21822 tankless troubleshooting manual, p. 62)
-
WiFi models: the leak alarm (17) was turned off in the app for 24 hours.48 Warning Code – Water leak detection disabled
WiFi models: the leak alarm (17) was turned off in the app for 24 hours. After 24 hours the heater shows 48. (AP21822 tankless troubleshooting manual, p. 62)
By model: Only when the WiFi controller is used.
Likely causes
- Leak detection was disabled for 24 hours through the WiFi app after a 17 code. (AP21822 tankless troubleshooting manual, p. 62)
-
WiFi models: the heater cannot find its leak sensor.49 Warning Code – Water leak sensor not installed
WiFi models: the heater cannot find its leak sensor. (AP21822 tankless troubleshooting manual, p. 62)
By model: Only when the WiFi controller is used. RTG-R manual also lists 149 for a missing/disconnected leak sensor.
Likely causes
- Water leak sensor not installed. (AP21822 tankless troubleshooting manual, p. 62)
For a technician
- Check the water leak sensor. (AP21822 tankless troubleshooting manual, p. 62)
-
WiFi models: water saving mode is limiting how much water flows.07 Warning Code – Limited hot water condition
WiFi models: water saving mode is limiting how much water flows. This is a warning, not a failure. (AP21822 tankless troubleshooting manual, p. 63)
By model: Only when the WiFi controller is used.
Likely causes
- Water saving mode is limiting the flow rate. (AP21822 tankless troubleshooting manual, p. 63)
-
WiFi models: the WiFi chip lost contact with the display.77 Warning Code – WiFi chip communication failure
WiFi models: the WiFi chip lost contact with the display. (AP21822 tankless troubleshooting manual, p. 63)
By model: Only when the WiFi controller is used.
Likely causes
- WiFi display. (AP21822 tankless troubleshooting manual, p. 63)
For a technician
- Check the WiFi display. (AP21822 tankless troubleshooting manual, p. 63)
-
WiFi models: the display could not read its saved settings.83 Warning Code – Configuration data restore failure
WiFi models: the display could not read its saved settings. (AP21822 tankless troubleshooting manual, p. 63)
By model: Only when the WiFi controller is used.
Likely causes
- WiFi display. (AP21822 tankless troubleshooting manual, p. 63)
For a technician
- Check the WiFi display. (AP21822 tankless troubleshooting manual, p. 63)
-
WiFi models: the display’s memory has been written to too many times.84 Warning Code – Configuration write limit exceeded
WiFi models: the display’s memory has been written to too many times. (AP21822 tankless troubleshooting manual, p. 63)
By model: Only when the WiFi controller is used.
Likely causes
- WiFi display. (AP21822 tankless troubleshooting manual, p. 63)
For a technician
- Check the WiFi display. (AP21822 tankless troubleshooting manual, p. 63)
-
WiFi models with a recirculation line: the recirculation setting in the app does not match the control board’s DIP switches.85 Warning Code – DIP switch not set for intended recirculation mode
WiFi models with a recirculation line: the recirculation setting in the app does not match the control board’s DIP switches. (AP21822 tankless troubleshooting manual, p. 64)
By model: Only with the WiFi controller and a recirculation line.
Likely causes
- Recirculation setting in the WiFi app does not match the DIP switch setting on the control board. (AP21822 tankless troubleshooting manual, p. 64)
What you can check
- Check the recirculation setting in the WiFi app. (AP21822 tankless troubleshooting manual, p. 64)
For a technician
- Check and set the DIP switches on the control board to match. (AP21822 tankless troubleshooting manual, p. 64)
-
Multi-heater setups: heater number 2, 3, 4, 5 or 6 (the last digit) cannot be seen by the manager heater.102-106 Error Code – Manifolding comm. error between unit 2-6 and manager unit
Multi-heater setups: heater number 2, 3, 4, 5 or 6 (the last digit) cannot be seen by the manager heater. (AP24838 RTG-R troubleshooting manual, p. 59)
Likely causes
- Incorrect manifold set-up; RJ11 cable not connected or damaged. (AP24838 RTG-R troubleshooting manual, p. 59)
- Manifolding communication error. (AP23962 RTG-R manual, p. 74)
For a technician
- Confirm all RJ11 cables are connected and in good condition; redo the setup; confirm the Manager unit and Unit Instance values. (AP24838 RTG-R troubleshooting manual, p. 59)
-
WiFi recirculation models: the leak sensor is missing or unplugged.149 Error Code – Water leak sensor not installed
WiFi recirculation models: the leak sensor is missing or unplugged. (AP24838 RTG-R troubleshooting manual, p. 59)
By model: Listed as an 'Error Code' in the heading but described as a 'warning code' in the text.
Likely causes
- Leak sensor missing or its connection to the WiFi display harness lost. (AP24838 RTG-R troubleshooting manual, p. 59)
For a technician
- Check the leak sensor and the WiFi display wire harness. (AP24838 RTG-R troubleshooting manual, p. 59)
-
WiFi recirculation models: the WiFi display lost contact with the heater’s control board.176 Error Code – WiFi display to water heater comm. error
WiFi recirculation models: the WiFi display lost contact with the heater’s control board. (AP24838 RTG-R troubleshooting manual, p. 60)
Likely causes
- WiFi display or PCB; cable connection. (AP24838 RTG-R troubleshooting manual, p. 60)
What you can check
- Confirm the cable connections are installed properly. (AP23962 RTG-R manual, p. 74)
For a technician
- Check the WiFi display and the PCB. (AP24838 RTG-R troubleshooting manual, p. 60)
-
Multi-heater setups: the manager heater found a problem with one of the linked heaters.195 Error Code – The manager unit detects a failure in one of the manifolded units
Multi-heater setups: the manager heater found a problem with one of the linked heaters. (AP24838 RTG-R troubleshooting manual, p. 60)
Likely causes
- Incorrect manifold set-up. (AP24838 RTG-R troubleshooting manual, p. 60)
For a technician
- Recheck the manifolding instructions (Multiple Unit Controls section). (AP23962 RTG-R manual, p. 74)
-
Multi-heater setups: the pump DIP switch settings do not match between heaters.196 Error Code – The manifolded unit detects incorrect local dip switch setting
Multi-heater setups: the pump DIP switch settings do not match between heaters. (AP24838 RTG-R troubleshooting manual, p. 60)
Likely causes
- Pump DIP switches not matching between linked RTG-R-3 heaters; or recirculation enabled on a no-pump RTG-3 heater that is linked to an RTG-R-3. (AP24838 RTG-R troubleshooting manual, p. 60)
For a technician
- Set the PCB DIP switches so the pump settings match on all RTG-R-3 heaters; leave RTG-3 (no pump) heaters on 'No Operation'. (AP24838 RTG-R troubleshooting manual, p. 60)
Tankless: earlier models
Rheem and Ruud tankless heaters from before the “-3” series. A few numbers mean something else on these.
-
Earlier indoor models: the flame sensor sees poor burning.05 – Warning Code (earlier platform)
Earlier indoor models: the flame sensor sees poor burning. Usually a venting or gas supply problem. (SVC 820P tankless service manual, p. 36)
By model: Same number, different meaning from the current '-3' platform (where 05 = low heat exchanger temperature). Both 2012 owner’s manuals (AP16115-1, AP15897-1) list 05 as a blocked intake/vent.
Likely causes
- Venting and/or gas supply problems; DIP2 altitude setting. (SVC 820P tankless service manual, p. 36)
- Air intake or vent exhaust opening may be blocked. (AP16115 tankless manual (2012), p. 26)
- The vent pipes on the vent termination may not be connected properly. (AP16115 tankless manual (2012), p. 26)
What you can check
- Remove any blockage from the air intake or vent exhaust opening (air intake needs 12 in. [30 cm] of clearance). (AP16115 tankless manual (2012), p. 26)
For a technician
- Check gas supply and venting; make sure DIP2 is set to the correct altitude. (SVC 820P tankless service manual, p. 36)
- Reconnect vent pipes at the termination (owner’s manual: contact a dealer or qualified service technician). (AP16115 tankless manual (2012), p. 26)
-
Earlier indoor models: the second flame sensor sees poor burning, usually from low gas supply or a venting problem.13 – Error Code
Earlier indoor models: the second flame sensor sees poor burning, usually from low gas supply or a venting problem. After 5 shutdowns in 4 hours it locks out until a technician resets it. (SVC 820P tankless service manual, p. 49)
By model: On the current '-3' and RTG-R platforms, 13 appears only in the list of hard lockouts in the reset procedure (AP21822 p. 61; AP24838 p. 56); those manuals give no description of it.
Likely causes
- Inadequate gas supply and/or venting; wrong DIP2 altitude setting. (SVC 820P tankless service manual, p. 49)
- Dirty flame rod (FL-2), dirty burner or manifold. (SVC 820P tankless service manual, p. 50)
What you can check
- Do the owner reset steps; if the code is still displayed, contact a dealer or qualified service technician. (AP16115 tankless manual (2012), pp. 25-26)
For a technician
- Check gas supply and venting; check DIP2 altitude setting. (SVC 820P tankless service manual, p. 49)
- Reseat connector T; check flame rod status in maintenance mode (0Y); clean or replace flame rods; remove and clean the manifold and burner; check gas supply, venting and ground. (SVC 820P tankless service manual, pp. 49-50)
- After 5 shutdowns in 4 hours, perform the hard-lockout reset. (SVC 820P tankless service manual, pp. 27, 49)
-
Earlier models (condensing and non-condensing): the heat exchanger stayed too cold for more than 3 minutes.29 – Error Code (B) (earlier platform)
Earlier models (condensing and non-condensing): the heat exchanger stayed too cold for more than 3 minutes. (SVC 820P tankless service manual, p. 57)
By model: Same number, different meaning from the condensate code. SVC 820P lists both 29 (A) and 29 (B).
Likely causes
- Inlet or heat exchanger thermistor, gas control valve, or water volume control valve. (SVC 820P tankless service manual, p. 57)
For a technician
- On condensing units first make sure condensate drains; test thermistors (31, 32); test gas valve resistances (connector R 40-80 ohms; connector K 0.8K-2.4K ohms); calculate temperature rise and max GPM; check connector C voltages; replace water volume control valve or control board. (SVC 820P tankless service manual, pp. 57-58)
-
Earlier condensing models: the condensate neutralizer needs to be replaced soon.92 & 93 – Error Code: 92 (neutralizer warning)
Earlier condensing models: the condensate neutralizer needs to be replaced soon. The heater still runs for now but will shut down later. (SVC 820P tankless service manual, p. 98)
By model: Condensing (H-series) models only.
Likely causes
- The neutralizer needs to be replaced soon. (AP15897 condensing tankless manual (2012), p. 26)
What you can check
- The unit can be used for a while, but contact a dealer or qualified service technician. (AP15897 condensing tankless manual (2012), p. 26)
For a technician
- Replace the neutralizer (calcium carbonate media) and reset with MIN + MAX. (SVC 820P tankless service manual, p. 98)
-
Earlier condensing models: the heater will not run until the condensate neutralizer is replaced.92 & 93 – Error Code: 93 (neutralizer must be replaced)
Earlier condensing models: the heater will not run until the condensate neutralizer is replaced. (SVC 820P tankless service manual, p. 98)
By model: Condensing (H-series) models only.
Likely causes
- The neutralizer must be replaced. (AP15897 condensing tankless manual (2012), p. 26)
What you can check
- The unit cannot be used until the neutralizer is replaced; contact a dealer or qualified service technician. (AP15897 condensing tankless manual (2012), p. 26)
For a technician
- Replace the neutralizer immediately and reset with MIN + MAX (CL shows, then press again more than 5 seconds). (SVC 820P tankless service manual, p. 98)
IKONIC tankless
Codes start with A or T, like A011, on the screen under SERVICE, Current Alarms.
-
Scale (lime) is building up inside the heat exchanger.A01L (owner’s chart) / ERROR A018 (service manual) - Lime build-up inside the heat exchanger
Scale (lime) is building up inside the heat exchanger. The heater must be drained and flushed. (AP21822 tankless troubleshooting manual, p. 34)
By model: The owner’s chart prints 'A01L' (AP22745 p. 107); the service manual heading is 'ERROR A018' (AP24727 p. 116). Same condition.
Likely causes
- Water heater has buildup of lime deposits. (AP22745 IKONIC manual, p. 107)
What you can check
- Contact a dealer or qualified service technician. (AP22745 IKONIC manual, p. 107)
For a technician
- Before flushing set SERVICE > 'Flush Heater?' to YES; flush with the Rheem/Ruud kit RTG20124; set it back to NO; clear the alarm. Flush yearly or as a professional recommends. (AP24727 IKONIC service guide, p. 116)
-
The heater tried to light 10 times and did not sense a flame.ERROR A011 - Flame Not Detected From Flame Rod
The heater tried to light 10 times and did not sense a flame. (AP24727 IKONIC service guide, p. 100)
Likely causes
- The gas shut-off valve is not fully opened. (AP22745 IKONIC manual, p. 107)
- Gas supply pressure, gas filter, air filter, venting, igniter rod, flame rod, gas-air ratio valve or solenoid valve. (AP24727 IKONIC service guide, p. 100)
What you can check
- Check the gas shut-off valve is open completely and venting/air supply is not blocked. (AP22745 IKONIC manual, p. 107)
For a technician
- Check gas supply pressure (NG 4.0-10.5 in. W.C., LP 8.0-13.0 in. W.C.); clean the gas filter and the air filter; check venting; check igniter, flame rod (Tankless Status > Flame Rod Status), solenoid valve and gas-air ratio valve (108-132 VAC); replace parts or control board per the chart. (AP24727 IKONIC service guide, pp. 100-106)
-
The flame lit and then went out 15 times in a row.ERROR A012 - Unit Detected Flame and Lost It
The flame lit and then went out 15 times in a row. (AP24727 IKONIC service guide, p. 108)
Likely causes
- Gas service has been interrupted. (AP22745 IKONIC manual, p. 107)
- LP gas is running low (LP models only). (AP22745 IKONIC manual, p. 107)
- Gas supply pressure, gas filter, air filter, venting, flame rod, gas-air ratio valve or solenoid valve. (AP24727 IKONIC service guide, p. 108)
What you can check
- If gas service was interrupted, contact your gas utility company. (AP22745 IKONIC manual, p. 107)
- LP models: refill or replace the LP gas container. (AP22745 IKONIC manual, p. 107)
For a technician
- Check gas pressure, gas filter, air filter, venting; check flame rod status; clean or replace the flame rod; check gas-air ratio valve and solenoid valve; replace control board per the chart. (AP24727 IKONIC service guide, pp. 108-112)
-
An overheat safety (limiter or fuse) has tripped.ERROR A014 - Over Heat Limiter (OHL) activated
An overheat safety (limiter or fuse) has tripped. Rheem says this is usually from the wrong gas supply or venting. (AP24727 IKONIC service guide, p. 114)
By model: IKONIC OHL/OHLF resistance spec is 5K-500K ohms (AP24727 p. 115); the '-3' OHL spec is 50K-500K ohms (AP21822 p. 41).
Likely causes
- Water heater is overheating. (AP22745 IKONIC manual, p. 107)
- OHL or OHLF activated; normally caused by inadequate/wrong gas supply and/or venting. (AP24727 IKONIC service guide, p. 114)
- A damaged or missing flame rod/igniter rod gasket can damage the OHL. (AP24727 IKONIC service guide, p. 114)
For a technician
- Reseat connector I and the blue OHL/OHLF Molex; measure OHL/OHLF resistance 5K-500K ohms; if not, replace the unit; if yes, replace the control board. (AP24727 IKONIC service guide, pp. 114-115)
-
The internal leak sensor (select models) found water.A017 - Leak sensor has detected water
The internal leak sensor (select models) found water. The heater will not run. (AP22745 IKONIC manual, p. 103)
By model: Only on models with the internal leak sensor. Not covered in the AP24727 service manual’s code list.
Likely causes
- Leak sensor has detected water. (AP22745 IKONIC manual, p. 107)
What you can check
- If water is found outside the heater, contact a dealer or qualified service technician immediately. (AP22745 IKONIC manual, p. 103)
- If no leak is seen, use the 24-hour temporary override: SETTINGS > LEAK OVERRIDE > YES. If A017 returns after 24 hours, check that the leak sensor is dry. (AP22745 IKONIC manual, p. 103)
For a technician
- If installing the outdoor conversion kit (RTGH-SX), the leak sensor must be disconnected. (AP22745 IKONIC manual, p. 103)
-
Condensate (acidic drain water) is not draining from the heater’s built-in trap.ERROR A029 - Condensate blockage
Condensate (acidic drain water) is not draining from the heater’s built-in trap. (AP24727 IKONIC service guide, p. 118)
By model: The service manual also says to remove the cap on the condensate connection at install or an A029 will occur (AP24727 p. 34).
Likely causes
- Blocked condensate line. (AP22745 IKONIC manual, p. 107)
- External condensate trap or the drain line from the unit’s condensate trap. (AP24727 IKONIC service guide, p. 118)
What you can check
- Check the external condensate trap and drain line from the heater for blockage. (AP24727 IKONIC service guide, p. 118)
For a technician
- Drain the condensate trap through its bottom plug; remove the drain line and retest; reseat the condensate trap connector; replace the control board per the chart. (AP24727 IKONIC service guide, p. 120)
-
The cold-water inlet temperature sensor has failed.ERROR A031 - Inlet Thermistor Malfunction
The cold-water inlet temperature sensor has failed. (AP21822 tankless troubleshooting manual, p. 3)
Likely causes
- Faulty inlet water thermistor. (AP22745 IKONIC manual, p. 107)
For a technician
- Measure thermistor resistance per the chart (inlet: 7K-23K ohms); clean scale off the thermistor; replace the thermistor, harness or control board. (AP24727 IKONIC service guide, pp. 122-123)
-
The heat exchanger temperature sensor has failed.ERROR A032 - Heat Exchanger Thermistor Malfunction
The heat exchanger temperature sensor has failed. (AP21822 tankless troubleshooting manual, p. 3)
Likely causes
- Faulty heat exchanger thermistor. (AP22745 IKONIC manual, p. 107)
For a technician
- Measure thermistor resistance per the chart (inlet: 7K-23K ohms); clean scale off the thermistor; replace the thermistor, harness or control board. (AP24727 IKONIC service guide, pp. 124-125)
-
The hot-water outlet temperature sensor has failed.ERROR A033 - Outlet Thermistor Malfunction
The hot-water outlet temperature sensor has failed. (AP21822 tankless troubleshooting manual, p. 3)
Likely causes
- Faulty outlet water thermistor. (AP22745 IKONIC manual, p. 107)
For a technician
- Measure thermistor resistance per the chart (inlet: 7K-23K ohms); clean scale off the thermistor; replace the thermistor, harness or control board. (AP24727 IKONIC service guide, pp. 126-127)
-
The exhaust temperature sensor has failed.ERROR A036 - Exhaust Thermistor Malfunction
The exhaust temperature sensor has failed. (AP24727 IKONIC service guide, p. 130)
Likely causes
- Faulty exhaust thermistor. (AP22745 IKONIC manual, p. 107)
For a technician
- Measure thermistor resistance per the chart (inlet: 7K-23K ohms); clean scale off the thermistor; replace the thermistor, harness or control board. (AP24727 IKONIC service guide, pp. 130-131)
-
A temperature sensor is loose or plugged into the wrong spot.ERROR A035 - Improper thermistor connection
A temperature sensor is loose or plugged into the wrong spot. (AP21822 tankless troubleshooting manual, p. 48)
Likely causes
- Improper thermistor connection (inlet, outlet, heat exchanger or exhaust thermistor). (AP24727 IKONIC service guide, p. 128)
For a technician
- Reseat and test the thermistors per the chart. (AP24727 IKONIC service guide, pp. 128-129)
-
The motor that sets the air/gas butterfly valve in the venturi is not working.ERROR A055 - Gas motor failed
The motor that sets the air/gas butterfly valve in the venturi is not working. (AP24727 IKONIC service guide, p. 132)
By model: The owner’s chart calls A055 'Faulty gas valve'; the service manual says it is the gas control motor on the venturi butterfly valve.
Likely causes
- Faulty gas valve (owner’s chart). (AP22745 IKONIC manual, p. 107)
- Gas control motor on the venturi assembly. (AP24727 IKONIC service guide, p. 132)
For a technician
- Reseat connector J; inspect the gas control motor; check 4-16 VDC at connector J while igniting; replace the motor/venturi parts or control board per the chart. (AP24727 IKONIC service guide, pp. 132-134)
-
The combustion fan is not spinning at the right speed.ERROR A061 - Blower RPM signal incorrect
The combustion fan is not spinning at the right speed. (AP24727 IKONIC service guide, p. 136)
Likely causes
- Faulty blower motor. (AP22745 IKONIC manual, p. 107)
For a technician
- Reseat connector D and the blower connector; check 144-192 VDC and other test voltages in operating mode 2H; replace control board or blower. (AP24727 IKONIC service guide, pp. 136-138)
-
Recirculation: the pump is running but no water flow is sensed.ERROR A063 - Pump abnormality
Recirculation: the pump is running but no water flow is sensed. (AP24727 IKONIC service guide, p. 140)
By model: Owner’s chart says SR (built-in pump) models only; service manual mentions internal or external pump. Different definition from the RTG-R '63' (pump speed).
Likely causes
- (Built-in recirculation) pump abnormality - 'SR models' only. (AP22745 IKONIC manual, p. 107)
- Recirculation pump (internal or external). (AP24727 IKONIC service guide, p. 140)
For a technician
- Reseat connector A and the pump Molex; check 108-132 VAC at connector A while the pump runs; replace the pump (internal or external) or the control board. (AP24727 IKONIC service guide, pp. 140-141)
-
The motorized valve that limits water flow through the heater is not working.ERROR A065 - Water volume control valve malfunction
The motorized valve that limits water flow through the heater is not working. (SVC 820P tankless service manual, p. 77)
Likely causes
- Faulty water flow solenoid (owner’s chart). (AP22745 IKONIC manual, p. 107)
For a technician
- Reseat connector G; check 4-10 VDC while water flows (the valve only works when demand exceeds the unit’s limit); replace the valve or control board. (AP24727 IKONIC service guide, pp. 142-144)
-
The bypass valve that blends water to control temperature is not working.ERROR A066 - Water bypass control valve malfunction
The bypass valve that blends water to control temperature is not working. (AP24727 IKONIC service guide, p. 146)
Likely causes
- Faulty bypass solenoid (owner’s chart). (AP22745 IKONIC manual, p. 107)
For a technician
- Set the temperature to 102 so the bypass valve activates; reseat connector G; check 4-16 VDC; replace the valve or control board. (AP24727 IKONIC service guide, pp. 146-148)
-
The control board’s computer chip is not working.ERROR A070 - Microcomputer Abnormality
The control board’s computer chip is not working. (AP21822 tankless troubleshooting manual, p. 53)
Likely causes
- Faulty control board. (AP22745 IKONIC manual, p. 107)
What you can check
- Turn power off and on. (AP24727 IKONIC service guide, p. 150)
For a technician
- If A070 appears again after a power cycle, replace the control board. (AP24727 IKONIC service guide, p. 150)
-
Flame is still sensed 8 seconds after the heater turned off.ERROR A071 - Gas Air ratio valve malfunction
Flame is still sensed 8 seconds after the heater turned off. The gas valve may not be closing. (AP24727 IKONIC service guide, p. 151)
Likely causes
- Faulty gas solenoid valve (owner’s chart). (AP22745 IKONIC manual, p. 107)
- Flame rod or gas-air ratio valve. (AP24727 IKONIC service guide, p. 151)
For a technician
- Reseat connectors C and H; watch through the sight glass while cycling ON-OFF 3 times; if flame shows while off more than 5 seconds, replace the gas-air ratio valve; else clean or replace the flame rod. (AP24727 IKONIC service guide, pp. 151-152)
-
Flame is sensed before the igniter sparks.ERROR A072 - Flame rod malfunction
Flame is sensed before the igniter sparks. (AP24727 IKONIC service guide, p. 154)
Likely causes
- Flame detected before ignition. (AP22745 IKONIC manual, p. 107)
- Flame rod or gas-air ratio valve. (AP24727 IKONIC service guide, p. 154)
For a technician
- Reseat connector H; power-cycle and watch through the sight glass; if flame shows before the spark, replace the gas-air ratio valve; else clean or replace the flame rod. (AP24727 IKONIC service guide, pp. 154-156)
-
The gas-type chip on the control board is loose, wrong, or bad.ERROR A082 - Installed Chip Error
The gas-type chip on the control board is loose, wrong, or bad. (AP21822 tankless troubleshooting manual, p. 59)
Likely causes
- Software error (owner’s chart). (AP22745 IKONIC manual, p. 107)
- Gas chip. (AP24727 IKONIC service guide, p. 158)
For a technician
- Confirm, reseat or replace the gas chip. (AP24727 IKONIC service guide, p. 158)
-
The heater found a blocked vent, air intake or air filter.ERROR A090 - Detected Blockage in Venting
The heater found a blocked vent, air intake or air filter. (AP24727 IKONIC service guide, p. 160)
Likely causes
- Air intake or vent exhaust opening may be blocked. (AP22745 IKONIC manual, p. 107)
- The vent pipes on the vent termination may not be connected properly. (AP22745 IKONIC manual, p. 107)
- Blocked vent termination or inlet air filter. (AP22745 IKONIC manual, p. 107)
- Venting, air filter or gas inlet pressure. (AP24727 IKONIC service guide, p. 160)
What you can check
- Remove any blockage from the air intake or vent exhaust (air intake requires 12 in. [30 cm] of clearance). (AP22745 IKONIC manual, p. 107)
For a technician
- Reconnect vent pipes; clean the inlet air filter (front cover must be removed); check gas inlet pressure. (AP24727 IKONIC service guide, p. 160)
-
The display (User Interface) cannot talk to the heater’s control board.ERROR A200 - Water Heater Communication Failure
The display (User Interface) cannot talk to the heater’s control board. (AP24727 IKONIC service guide, p. 162)
By model: Not in the owner’s chart (AP22745 p. 107).
Likely causes
- User interface. (AP24727 IKONIC service guide, p. 162)
For a technician
- Check the user interface and its connection per the chart. (AP24727 IKONIC service guide, p. 162)
-
Multi-heater setups (up to 20): the manager heater shows A2 plus the number of the heater that has a problem.ERROR 2## - Water heater comm. failure instance (## is No. 02 to No. 20)
Multi-heater setups (up to 20): the manager heater shows A2 plus the number of the heater that has a problem. Example: A205 means heater number 5 has an error. (AP24727 IKONIC service guide, p. 164)
Likely causes
- One of the manifolded water heaters is showing an error code. (AP24727 IKONIC service guide, p. 164)
For a technician
- Read the error code on the heater with that instance number and diagnose that code. (AP24727 IKONIC service guide, p. 164)
-
The WiFi chip lost contact with the display.ERROR T110 - WiFi chip communication error
The WiFi chip lost contact with the display. (AP24727 IKONIC service guide, p. 165)
Likely causes
- User interface (WiFi chip). (AP24727 IKONIC service guide, p. 165)
What you can check
- Reset the WiFi setting on the display and set up WiFi again. (AP24727 IKONIC service guide, p. 165)
For a technician
- If T110 persists after WiFi setup, replace the user interface. (AP24727 IKONIC service guide, p. 165)
-
A service reminder is due: flush the heat exchanger and/or replace the water treatment filter.NOTIFICATION T111 - Service reminder alert
A service reminder is due: flush the heat exchanger and/or replace the water treatment filter. If ignored, the heater will eventually shut down. (AP24727 IKONIC service guide, p. 166)
Likely causes
- Reminder of flushing the heat exchanger and/or replacing the water treatment filter. (AP22745 IKONIC manual, p. 107)
- This is a warning code and the unit will eventually shut down to protect itself. (AP24727 IKONIC service guide, p. 166)
What you can check
- Contact a dealer or qualified service technician. (AP22745 IKONIC manual, p. 107)
For a technician
- Drain and flush the unit, then clear the alarm (Clearing Current Alarms). (AP24727 IKONIC service guide, p. 166)
-
Not enough hot water is flowing for the heater to turn on (needs at least 0.4 gallons per minute).NOTIFICATION T113 - flow rate below 0.4 GPM
Not enough hot water is flowing for the heater to turn on (needs at least 0.4 gallons per minute). (AP24727 IKONIC service guide, p. 168)
Likely causes
- Not enough hot water to operate the unit. (AP22745 IKONIC manual, p. 107)
- Not enough water flow; water supply lines; water filter. (AP24727 IKONIC service guide, p. 168)
What you can check
- Increase the water flow from the fixtures. (AP22745 IKONIC manual, p. 107)
- Clean the water inlet filter (owner’s manual: check and clean monthly). (AP22745 IKONIC manual, pp. 97-98)
For a technician
- Check for crossed hot/cold lines; drain and flush for scale; clean the in-line water filter; remove and clean the water control valve flow sensor. (AP24727 IKONIC service guide, p. 168)
-
Recirculation schedule mode is on, but the display never got the schedule time.NOTIFICATION T115 - Pump schedule disable - No time received
Recirculation schedule mode is on, but the display never got the schedule time. (AP24727 IKONIC service guide, p. 170)
Likely causes
- Recirc Pump Mode set to SCHEDULE without a received time. (AP24727 IKONIC service guide, p. 170)
What you can check
- Recheck the scheduled time setting in the EcoNet app. (AP24727 IKONIC service guide, p. 170)
-
Multi-heater setups: a linked heater cannot talk to the manager heater.ERROR T116 - Manifold unit fault
Multi-heater setups: a linked heater cannot talk to the manager heater. (AP24727 IKONIC service guide, p. 171)
Likely causes
- Connecting cable between water heaters. (AP24727 IKONIC service guide, p. 171)
For a technician
- Reseat the cable; swap cables between heaters to see if the fault follows the cable; replace the cable, or the user interface and/or control board. (AP24727 IKONIC service guide, p. 171)
ProTerra heat pump water heaters
Electric hybrid tanks. Codes start with A or T under Current Alarm. They have nothing to do with the gas codes above.
-
The heat pump compressor shut down.Comp.Shutdown: Discharge-Suction Trip
The heat pump compressor shut down. The heater switches to its electric elements. (AP23657 ProTerra manual, p. 33)
By model: HEAT PUMP (electric) model, not gas.
Likely causes
- Heating source defaults to elements due to compressor malfunction (AP23657 ProTerra manual, pp. 33-35)
What you can check
- Confirm the filter screen is clean. (AP23657 ProTerra manual, p. 33)
For a technician
- Confirm the fan runs while the compressor is on (check fan continuity/voltage; replace fan or, rarely, control board); inspect the compressor area for oily residue (refrigerant leak). Rheem does not service sealed-system parts; the unit is replaced if the compressor fails or leaks. (AP23657 ProTerra manual, p. 33)
-
The compressor got too hot and shut down.Compressor Shutdown: Discharge Temp High
The compressor got too hot and shut down. The heater switches to its electric elements. (AP23657 ProTerra manual, p. 33)
By model: HEAT PUMP (electric) model, not gas.
Likely causes
- Heating source defaults to elements due to compressor malfunction (AP23657 ProTerra manual, pp. 33-35)
What you can check
- Confirm the filter screen is clean. (AP23657 ProTerra manual, p. 33)
For a technician
- Confirm the fan runs while the compressor is on (check fan continuity/voltage; replace fan or, rarely, control board); inspect the compressor area for oily residue (refrigerant leak). Rheem does not service sealed-system parts; the unit is replaced if the compressor fails or leaks. (AP23657 ProTerra manual, p. 33)
-
The compressor got too hot because of low airflow.Compressor Shutdown: Discharge Temp High
The compressor got too hot because of low airflow. The heater switches to its electric elements. (AP23657 ProTerra manual, p. 33)
By model: HEAT PUMP (electric) model, not gas.
Likely causes
- Heating source defaults to elements due to low airflow (AP23657 ProTerra manual, pp. 33-35)
What you can check
- Confirm the filter screen is clean. (AP23657 ProTerra manual, p. 33)
For a technician
- Confirm the fan runs while the compressor is on (check fan continuity/voltage; replace fan or, rarely, control board); inspect the compressor area for oily residue (refrigerant leak). Rheem does not service sealed-system parts; the unit is replaced if the compressor fails or leaks. (AP23657 ProTerra manual, p. 33)
-
The heat pump’s suction temperature is too low.Suction Temperature Too Low
The heat pump’s suction temperature is too low. The heater switches to its electric elements. (AP23657 ProTerra manual, p. 33)
By model: HEAT PUMP (electric) model, not gas.
Likely causes
- Heating source defaults to elements due to compressor malfunction (AP23657 ProTerra manual, pp. 33-35)
What you can check
- Confirm the filter screen is clean. (AP23657 ProTerra manual, p. 33)
For a technician
- Confirm the fan runs while the compressor is on (check fan continuity/voltage; replace fan or, rarely, control board); inspect the compressor area for oily residue (refrigerant leak). Rheem does not service sealed-system parts; the unit is replaced if the compressor fails or leaks. (AP23657 ProTerra manual, p. 33)
-
The heat pump’s suction temperature is too low.Suction Temperature Too Low
The heat pump’s suction temperature is too low. The heater switches to its electric elements. (AP23657 ProTerra manual, p. 33)
By model: HEAT PUMP (electric) model, not gas.
Likely causes
- Heating source defaults to elements due to compressor malfunction (AP23657 ProTerra manual, pp. 33-35)
What you can check
- Confirm the filter screen is clean. (AP23657 ProTerra manual, p. 33)
For a technician
- Confirm the fan runs while the compressor is on (check fan continuity/voltage; replace fan or, rarely, control board); inspect the compressor area for oily residue (refrigerant leak). Rheem does not service sealed-system parts; the unit is replaced if the compressor fails or leaks. (AP23657 ProTerra manual, p. 33)
-
The tank does not have enough water (often air trapped after install), so the heater is turned off to protect the elements.Detected Dry Fire Condition
The tank does not have enough water (often air trapped after install), so the heater is turned off to protect the elements. (AP23657 ProTerra manual, p. 33)
By model: HEAT PUMP (electric) model, not gas. Rheem notes this is generally an installation issue; board or sensor problems would show a different code.
Likely causes
- Dry fire protection- Not sufficient water in storage tank: Heater disabled (AP23657 ProTerra manual, pp. 33-35)
What you can check
- Fill the storage tank with water and purge all air by running a hot water faucet; if A008 is still shown, air is still present, so purge again. (AP23657 ProTerra manual, p. 33)
-
Possible compressor wiring fault.Compressor wiring may be faulty
Possible compressor wiring fault. The heater switches to its electric elements. (AP23657 ProTerra manual, p. 33)
By model: HEAT PUMP (electric) model, not gas.
Likely causes
- Heating source default to elements due to compressor malfunction (AP23657 ProTerra manual, pp. 33-35)
For a technician
- Check wiring and sensor connections; measure thermistor ohms against the ohm chart; check Service > Sensors on the display (-40°F = open circuit, +250°F = shorted); confirm by unplugging the thermistor and measuring. (AP23657 ProTerra manual, p. 33)
-
Possible compressor wiring fault.Compressor wiring may be faulty
Possible compressor wiring fault. The heater switches to its electric elements. (AP23657 ProTerra manual, p. 33)
By model: HEAT PUMP (electric) model, not gas.
Likely causes
- Heating source default to elements due to compressor malfunction (AP23657 ProTerra manual, pp. 33-35)
For a technician
- Check wiring and sensor connections; measure thermistor ohms against the ohm chart; check Service > Sensors on the display (-40°F = open circuit, +250°F = shorted); confirm by unplugging the thermistor and measuring. (AP23657 ProTerra manual, p. 33)
-
A heat pump temperature sensor failed.Suction Temperature Sensor Failure
A heat pump temperature sensor failed. The heater switches to its electric elements. (AP23657 ProTerra manual, p. 33)
By model: HEAT PUMP (electric) model, not gas.
Likely causes
- Heating source defaults to elements due to heat pump temperature sensor malfunction (AP23657 ProTerra manual, pp. 33-35)
For a technician
- Check wiring and sensor connections; measure thermistor ohms against the ohm chart; check Service > Sensors on the display (-40°F = open circuit, +250°F = shorted); confirm by unplugging the thermistor and measuring. (AP23657 ProTerra manual, p. 33)
-
A heat pump temperature sensor failed.Ambient Temperature Sensor Failure
A heat pump temperature sensor failed. The heater switches to its electric elements. (AP23657 ProTerra manual, p. 33)
By model: HEAT PUMP (electric) model, not gas.
Likely causes
- Heating source defaults to elements due to heat pump temperature sensor malfunction (AP23657 ProTerra manual, pp. 33-35)
For a technician
- Check wiring and sensor connections; measure thermistor ohms against the ohm chart; check Service > Sensors on the display (-40°F = open circuit, +250°F = shorted); confirm by unplugging the thermistor and measuring. (AP23657 ProTerra manual, p. 33)
-
A tank temperature sensor failed.Lower Heater Temp Sensor Failure
A tank temperature sensor failed. The heater is turned off. (AP23657 ProTerra manual, p. 33)
By model: HEAT PUMP (electric) model, not gas. The manual’s cause cell reads 'Lower tank temperature sensor malfunction' for both A103 and A104.
Likely causes
- Lower tank temperature sensor malfunction. Heater disabled. (AP23657 ProTerra manual, pp. 33-35)
For a technician
- Check wiring and sensor connections; measure thermistor ohms against the ohm chart; check Service > Sensors on the display (-40°F = open circuit, +250°F = shorted); confirm by unplugging the thermistor and measuring. (AP23657 ProTerra manual, p. 33)
-
A tank temperature sensor failed.Upper Heater Temp Sensor Failure
A tank temperature sensor failed. The heater is turned off. (AP23657 ProTerra manual, p. 33)
By model: HEAT PUMP (electric) model, not gas. The manual’s cause cell reads 'Lower tank temperature sensor malfunction' for both A103 and A104.
Likely causes
- Lower tank temperature sensor malfunction. Heater disabled. (AP23657 ProTerra manual, pp. 33-35)
For a technician
- Check wiring and sensor connections; measure thermistor ohms against the ohm chart; check Service > Sensors on the display (-40°F = open circuit, +250°F = shorted); confirm by unplugging the thermistor and measuring. (AP23657 ProTerra manual, p. 33)
-
A heat pump temperature sensor failed.Evaporator Temp Sensor Failure
A heat pump temperature sensor failed. The heater switches to its electric elements. (AP23657 ProTerra manual, p. 33)
By model: HEAT PUMP (electric) model, not gas.
Likely causes
- Heating source defaults to elements due to heat pump temperature malfunction. (AP23657 ProTerra manual, pp. 33-35)
For a technician
- Check wiring and sensor connections; measure thermistor ohms against the ohm chart; check Service > Sensors on the display (-40°F = open circuit, +250°F = shorted); confirm by unplugging the thermistor and measuring. (AP23657 ProTerra manual, p. 33)
-
A heat pump temperature sensor failed.Discharge Temp Sensor Failure
A heat pump temperature sensor failed. The heater switches to its electric elements. (AP23657 ProTerra manual, p. 33)
By model: HEAT PUMP (electric) model, not gas.
Likely causes
- Heating source defaults to elements due to heat pump temperature malfunction. (AP23657 ProTerra manual, pp. 33-35)
For a technician
- Check wiring and sensor connections; measure thermistor ohms against the ohm chart; check Service > Sensors on the display (-40°F = open circuit, +250°F = shorted); confirm by unplugging the thermistor and measuring. (AP23657 ProTerra manual, p. 33)
-
The leak (rope) sensor found water in the drain pan.Water Detected on Floor: Check For Leaks
The leak (rope) sensor found water in the drain pan. (AP23657 ProTerra manual, p. 33)
By model: HEAT PUMP (electric) model, not gas.
Likely causes
- Water is detected in the drain pan (AP23657 ProTerra manual, pp. 33-35)
What you can check
- Check for obvious water leaks; if there is a leak, have the unit serviced for leakage. (AP23657 ProTerra manual, p. 33)
- Press and hold the 'Clear Alarm' button for 5 seconds to override the alarm for 24 hours. (AP23657 ProTerra manual, p. 33)
For a technician
- If no leak: disconnect the rope sensor from the board; if the code clears, dry (a blow dryer is acceptable) or replace the rope sensor; if it persists with a new sensor, replace the board. (AP23657 ProTerra manual, p. 33)
-
The condensate drain is blocked.Condensate Blocked: Unclog Line
The condensate drain is blocked. The heater switches to its electric elements. (AP23657 ProTerra manual, p. 33)
By model: HEAT PUMP (electric) model, not gas.
Likely causes
- Heating source defaults to elements due to condensate drain blockage (AP23657 ProTerra manual, pp. 33-35)
What you can check
- Check where the condensate line is routed and that it is not blocked. (AP23657 ProTerra manual, p. 33)
For a technician
- Remove the top cover; check the condensate line and pan; clear the blockage; if the pan is dry and the line is clear, replace the condensate sensor. (AP23657 ProTerra manual, p. 33)
-
A heating element or its relay has failed.Lower Element Error or Relay Stuck Closed
A heating element or its relay has failed. The heater is turned off. (AP23657 ProTerra manual, p. 34)
By model: HEAT PUMP (electric) model, not gas.
Likely causes
- Heating element or control board failure. Heater disabled. (AP23657 ProTerra manual, pp. 33-35)
For a technician
- Disconnect power; check element resistance against the ohm chart; if the reading is good replace the board, if not replace the element. (AP23657 ProTerra manual, p. 34)
-
A heating element or its relay has failed.Upper Element Error or Relay Stuck Closed
A heating element or its relay has failed. The heater is turned off. (AP23657 ProTerra manual, p. 34)
By model: HEAT PUMP (electric) model, not gas.
Likely causes
- Heating element or control board failure. Heater disabled. (AP23657 ProTerra manual, pp. 33-35)
For a technician
- Disconnect power; check element resistance against the ohm chart; if the reading is good replace the board, if not replace the element. (AP23657 ProTerra manual, p. 34)
-
The heating elements are wired wrong, or the control board failed.Element Wire Routing Error
The heating elements are wired wrong, or the control board failed. The heater is turned off. (AP23657 ProTerra manual, p. 34)
By model: HEAT PUMP (electric) model, not gas.
Likely causes
- Elements mis-wired or control board failure. Heater disabled. (AP23657 ProTerra manual, pp. 33-35)
For a technician
- Disconnect power; check element wiring at element and board; check element ohms; replace board or element. (AP23657 ProTerra manual, p. 34)
-
A control board relay for a heating element did not close.Lower Element Relay Failure to Close Error
A control board relay for a heating element did not close. The heater is turned off. (AP23657 ProTerra manual, p. 34)
By model: HEAT PUMP (electric) model, not gas.
Likely causes
- Control board relay failure. Heater disabled. (AP23657 ProTerra manual, pp. 33-35)
For a technician
- Disconnect power; check wiring and ohm readings; replace the board or relay. (AP23657 ProTerra manual, p. 34)
-
A control board relay for a heating element did not close.Upper Element Relay Failure to Close Error
A control board relay for a heating element did not close. The heater is turned off. (AP23657 ProTerra manual, p. 34)
By model: HEAT PUMP (electric) model, not gas.
Likely causes
- Control board relay failure. Heater disabled. (AP23657 ProTerra manual, pp. 33-35)
For a technician
- Disconnect power; check wiring and ohm readings; replace the board or relay. (AP23657 ProTerra manual, p. 34)
-
The unit is off and the air around it is below freezing.Unit Off/Air Temp Freezing: Enable Unit
The unit is off and the air around it is below freezing. (AP23657 ProTerra manual, p. 34)
By model: HEAT PUMP (electric) model, not gas.
Likely causes
- Ambient temperature is below freezing. --FREEZE WARNING (AP23657 ProTerra manual, pp. 33-35)
What you can check
- Select a mode to enable the heater (turn it on). (AP23657 ProTerra manual, p. 34)
-
Reminder to clean the air filter.Clean Filter Reminder
Reminder to clean the air filter. (AP23657 ProTerra manual, p. 34)
By model: HEAT PUMP (electric) model, not gas.
Likely causes
- Air filter routine maintenance reminder (AP23657 ProTerra manual, pp. 33-35)
What you can check
- Set the mode to Electric or OFF; remove the air filter and wash it with mild detergent; dry and reinstall; set the unit back to the desired mode. (AP23657 ProTerra manual, p. 34)
-
The heater cannot keep up with hot water use.Water Heater difficulty satisfying demand
The heater cannot keep up with hot water use. (AP23657 ProTerra manual, p. 34)
By model: HEAT PUMP (electric) model, not gas.
Likely causes
- Water heater can not satisfy demand (AP23657 ProTerra manual, pp. 33-35)
What you can check
- Check for open faucets and for water leaks; if none, the unit may be improperly sized. (AP23657 ProTerra manual, p. 34)
-
Problem with the optional automatic water shut-off valve.Shutoff Valve Can’t Close Error
Problem with the optional automatic water shut-off valve. (AP23657 ProTerra manual, p. 34)
By model: HEAT PUMP (electric) model, not gas.
Likely causes
- Shut-Off Valve malfunction (AP23657 ProTerra manual, pp. 33-35)
What you can check
- Unplug and plug back in the shut-off valve; if the alarm persists, call customer service. If no shut-off valve is installed, set 'shut off valve' to NO in the mode menu. (AP23657 ProTerra manual, p. 34)
For a technician
- Check the shut-off valve wiring connections. (AP23657 ProTerra manual, p. 34)
-
Problem with the optional automatic water shut-off valve.Shutoff Valve Can’t Open Error
Problem with the optional automatic water shut-off valve. (AP23657 ProTerra manual, p. 34)
By model: HEAT PUMP (electric) model, not gas.
Likely causes
- Shut-Off Valve malfunction (AP23657 ProTerra manual, pp. 33-35)
What you can check
- Unplug and plug back in the shut-off valve; if the alarm persists, call customer service. If no shut-off valve is installed, set 'shut off valve' to NO in the mode menu. (AP23657 ProTerra manual, p. 34)
For a technician
- Check the shut-off valve wiring connections. (AP23657 ProTerra manual, p. 34)
-
Problem with the optional automatic water shut-off valve.Shutoff Valve Inputs in Error
Problem with the optional automatic water shut-off valve. (AP23657 ProTerra manual, p. 34)
By model: HEAT PUMP (electric) model, not gas.
Likely causes
- Shut-Off Valve malfunction (AP23657 ProTerra manual, pp. 33-35)
What you can check
- Unplug and plug back in the shut-off valve; if the alarm persists, call customer service. If no shut-off valve is installed, set 'shut off valve' to NO in the mode menu. (AP23657 ProTerra manual, p. 34)
For a technician
- Check the shut-off valve wiring connections. (AP23657 ProTerra manual, p. 34)
-
Problem with the optional automatic water shut-off valve.Shut-Off Valve Not Installed
Problem with the optional automatic water shut-off valve. (AP23657 ProTerra manual, p. 34)
By model: HEAT PUMP (electric) model, not gas.
Likely causes
- Shut-Off Valve malfunction (AP23657 ProTerra manual, pp. 33-35)
What you can check
- Unplug and plug back in the shut-off valve; if the alarm persists, call customer service. If no shut-off valve is installed, set 'shut off valve' to NO in the mode menu. (AP23657 ProTerra manual, p. 34)
For a technician
- Check the shut-off valve wiring connections. (AP23657 ProTerra manual, p. 34)
-
The high-temperature safety (ECO) tripped.High Water Temp! [ECO] Call Tech Service
The high-temperature safety (ECO) tripped. The heater is turned off. (AP23657 ProTerra manual, p. 34)
By model: HEAT PUMP (electric) model, not gas. Not the same as IKONIC tankless A200 (communication failure).
Likely causes
- ECO Tripped. Heater Disabled (AP23657 ProTerra manual, pp. 33-35)
For a technician
- Disconnect power; check elements screw-to-ground; check thermistor resistance; if neither is the cause, replace the board. (AP23657 ProTerra manual, p. 34)
-
The heater cannot find its water leak sensor.Water Leak Sensor Not Installed
The heater cannot find its water leak sensor. (AP23657 ProTerra manual, p. 34)
By model: HEAT PUMP (electric) model, not gas.
Likely causes
- Water Leak Sensor Not Installed (AP23657 ProTerra manual, pp. 33-35)
What you can check
- Check that the water leak sensor is installed. (AP23657 ProTerra manual, p. 34)
For a technician
- Check sensor wiring to the board and the sensor’s resistance (ohm chart) to decide whether to replace the sensor or the board. (AP23657 ProTerra manual, p. 34)
-
Control board problem.Time Clock needs to be programmed
Control board problem. The heater is turned off. (AP23657 ProTerra manual, p. 35)
By model: HEAT PUMP (electric) model, not gas.
Likely causes
- Controller malfunction. Heater disabled. (AP23657 ProTerra manual, pp. 33-35)
For a technician
- Replace the control board. (AP23657 ProTerra manual, p. 35)
-
Control board problem.Time Clock not advancing time properly
Control board problem. The heater is turned off. (AP23657 ProTerra manual, p. 35)
By model: HEAT PUMP (electric) model, not gas.
Likely causes
- Controller malfunction. Heater disabled. (AP23657 ProTerra manual, pp. 33-35)
For a technician
- Replace the control board. (AP23657 ProTerra manual, p. 35)
-
Control board problem.WiFi Chip Communication Error
Control board problem. The heater is turned off. (AP23657 ProTerra manual, p. 35)
By model: HEAT PUMP (electric) model, not gas.
Likely causes
- Controller malfunction. Heater disabled. (AP23657 ProTerra manual, pp. 33-35)
For a technician
- Replace the control board. (AP23657 ProTerra manual, p. 35)
-
Control board problem.Controller Fault: Call Tech Service
Control board problem. The heater is turned off. (AP23657 ProTerra manual, p. 35)
By model: HEAT PUMP (electric) model, not gas.
Likely causes
- Controller malfunction. Heater disabled. (AP23657 ProTerra manual, pp. 33-35)
For a technician
- Replace the control board. (AP23657 ProTerra manual, p. 35)
-
Control board problem.Controller Fault: Call Tech Service
Control board problem. The heater is turned off. (AP23657 ProTerra manual, p. 35)
By model: HEAT PUMP (electric) model, not gas.
Likely causes
- Controller malfunction. Heater disabled. (AP23657 ProTerra manual, pp. 33-35)
For a technician
- Replace the control board. (AP23657 ProTerra manual, p. 35)
-
Control board problem.Controller Fault: Call Tech Service
Control board problem. The heater is turned off. (AP23657 ProTerra manual, p. 35)
By model: HEAT PUMP (electric) model, not gas.
Likely causes
- Controller malfunction. Heater disabled. (AP23657 ProTerra manual, pp. 33-35)
For a technician
- Replace the control board. (AP23657 ProTerra manual, p. 35)
-
Control board problem.Controller Fault: Call Tech Service
Control board problem. The heater is turned off. (AP23657 ProTerra manual, p. 35)
By model: HEAT PUMP (electric) model, not gas.
Likely causes
- Controller malfunction. Heater disabled. (AP23657 ProTerra manual, pp. 33-35)
For a technician
- Replace the control board. (AP23657 ProTerra manual, p. 35)
-
Control board problem.Controller Fault: Call Tech Service
Control board problem. The heater is turned off. (AP23657 ProTerra manual, p. 35)
By model: HEAT PUMP (electric) model, not gas.
Likely causes
- Controller malfunction. Heater disabled. (AP23657 ProTerra manual, pp. 33-35)
For a technician
- Replace the control board. (AP23657 ProTerra manual, p. 35)
-
Control board problem.Controller Fault: Call Tech Service
Control board problem. The heater is turned off. (AP23657 ProTerra manual, p. 35)
By model: HEAT PUMP (electric) model, not gas.
Likely causes
- Controller malfunction. Heater disabled. (AP23657 ProTerra manual, pp. 33-35)
For a technician
- Replace the control board. (AP23657 ProTerra manual, p. 35)
-
The control board is getting too hot.Power Board Temp. Protection Sensor Failure
The control board is getting too hot. (AP23657 ProTerra manual, p. 35)
By model: HEAT PUMP (electric) model, not gas.
Likely causes
- Controller getting too hot. (AP23657 ProTerra manual, pp. 33-35)
For a technician
- Replace the control board. (AP23657 ProTerra manual, p. 35)
No Rheem code matches that. Check the number on the display again, or look at the other brands.
Clearing a code
How to reset a Rheem, and when to stop
To clear a code
- There is no reset button for the STATUS light. If the light is not blinking blue, relight the pilot by following the lighting instructions on the heater and in the manual. Codes can only be read while the pilot is lit. (AP23060 gas tank manual, pp. 17, 24)
- Lighting instructions (owner): turn the knob to OFF and wait 5 minutes; if you smell gas, stop. Remove the outer door only (not the inner door), turn the knob to PILOT, hold it in while pressing the igniter button until the STATUS light blinks, check the pilot through the sight glass, replace the outer door, release the knob and set the temperature. (AP23060 gas tank manual, p. 17)
- The power-vent gas control tries to light 3 times, then locks out and a warning light shows. The manual’s owner steps are to check the error code table and call a technician; resetting the control (TCO reset, flammable vapor sensor reset, power cycle of the gas control) is listed as a solution step in the code table. (AP22510 power-vent manual, pp. 29, 37)
- The Professional Classic power-vent manual has the same LED/LCD code table and the same solution steps (for example 'Reset the TCO' for LCD 31 and 'Cycle power to the combination gas control' for LCD 93). (AP22511 Professional Classic power-vent manual, p. 37)
- Owner reset for a displayed code: turn off all hot taps; turn the heater off with POWER ON/OFF; wait about 5 minutes and turn it back on; open a hot tap and recheck. If the code is still there: turn off the tap and heater, unplug the heater for about 30 seconds, plug back in, follow the code chart, and recheck. If it still shows, write down the code and call for service. (AP21820 condensing tankless manual, p. 74)
- Same owner reset steps (turn off, wait about 5 minutes, restart; then unplug about 30 seconds) in the 2012 Use and Care manuals. (AP15897 condensing tankless manual (2012), p. 25)
- Hard lockouts (codes 10, 13 and 99) need a technician reset at the control board: remote OFF, front cover off, all DIP switches OFF, flip DIP1 switch #2 ON then OFF, then within 5 seconds hold MIN and MAX for 2 seconds until the display flashes 'UL'. (AP21822 tankless troubleshooting manual, p. 61)
- Same hard-lockout reset for codes 10, 13 and 99 on the earlier platform (DIP1 switch #2, then MIN + MAX, display flashes 'UL'). Fault history is cleared with DIP1 switch #1 and MIN or MAX ('CL'). (SVC 820P tankless service manual, pp. 27-28)
- 1L lime code is reset by holding the MIN and MAX buttons on the control board for 10 seconds (after flushing). (AP21822 tankless troubleshooting manual, p. 34)
- Code 88 clearing (owner manual): remote ON; close the gas and water shut-off valves; press DOWN to the lowest temperature; hold DOWN and UP together 5-10 seconds; reopen the gas and water valves. Rheem says to flush the heat exchanger and/or replace the water treatment filter first. (AP21820 condensing tankless manual, p. 77)
- Neutralizer codes 92/93 (earlier condensing models): after the neutralizer is replaced, with the remote ON and no water flowing, press MIN and MAX together ('CL' shows), then press MIN and MAX again for more than 5 seconds until CL disappears. (SVC 820P tankless service manual, p. 98)
- IKONIC: clear codes from the display: turn off hot taps, press SERVICE, ENTER on 'Current Alarms', choose 'Clear Alarms?', select 'Yes' and press ENTER. If the code is still shown, turn the heater off, note the code and call for service. (AP22745 IKONIC manual, p. 106)
- ProTerra: read alarms by pressing NEXT until 'Current Alarm' shows, then the Down arrow to scroll. The Clear Alarm button clears alarms; for A107 (water on floor) holding Clear Alarm for 5 seconds overrides the alarm for 24 hours. (AP23657 ProTerra manual, pp. 32-33)
Rheem’s safety notes
- What to do if you smell gas: do not try to light any appliance; do not touch any electric switch or use any phone in the building; call the gas supplier from a neighbor’s phone; if you cannot reach them, call the fire department. (AP23060 gas tank manual, p. 17)
- Before lighting, smell all around the appliance area for gas, including next to the floor, because some gas is heavier than air. (AP23060 gas tank manual, p. 17)
- Use only your hand to turn the gas control knob. Never use tools. If the knob will not turn by hand, do not try to repair it; call a qualified service technician. (AP23060 gas tank manual, p. 17)
- Do not use the water heater if any part has been under water. Call a qualified installer or service agency to replace a flooded water heater. (AP23060 gas tank manual, p. 17)
- If the pilot will not stay lit after several lighting attempts, turn the knob to OFF and call your service technician or gas supplier. If the knob does not pop back out when released, stop and immediately call your service technician or gas supplier. (AP23060 gas tank manual, p. 17)
- Should overheating occur or the gas supply fail to shut off, turn off the manual gas control valve to the appliance. (AP23060 gas tank manual, p. 19)
- DO NOT attempt repair of gas piping, the Combination Gas Control (Thermostat), burners, vent connectors or other safety devices. Refer repairs to qualified service personnel. (AP23060 gas tank manual, pp. 22-23)
- Power vent: if the flammable vapor sensor shuts the heater down, contact a qualified service technician, clear any hazardous materials and ventilate the area. Do NOT turn off the appliance or adjust the ON/OFF switch, and do not tamper with the sensor. (AP22510 power-vent manual, p. 3)
- Power vent: label all wires before disconnecting when servicing controls; wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. (AP22510 power-vent manual, p. 37)
- Tankless: shock hazard. Make certain power to the heater is OFF before removing the protective cover. Do not attempt repair of electrical wiring, gas piping, remote control, burners, vent connectors or other safety devices. (AP21820 condensing tankless manual, p. 74)
- Tankless: if the displayed error code is not listed in the chart, immediately turn off the water heater and call for service assistance. (AP21820 condensing tankless manual, p. 74)
- Tankless (service manual): the ignition cable carries more than 10,000 volts. Turn off all power and verify with a meter before replacing parts. (AP21822 tankless troubleshooting manual, p. 7)
- Earlier tankless platform, code 13: if the unit shuts down 5 times within a 4-hour period due to code 13, it must be reset with the hard-lockout reset procedure (technician). (SVC 820P tankless service manual, p. 49)
- IKONIC: when cleaning or replacing the flame rod or igniter rod, the gasket must be replaced with the Rheem-approved gasket; a damaged or missing gasket can cause unsafe operation or damage the overheat limiter. (AP24727 IKONIC service guide, pp. 104, 114)
- IKONIC: removing the front cover panel (for example to clean the air filter) exposes live electricity. (AP22745 IKONIC manual, p. 97)
Heater getting old, or the same code keeps coming back? Repair or replace? Three taps and Dan’s answer → Or see what a water heater repair usually involves.
Which one do you have?
The Rheem heaters these codes cover
- Gas tank with a status light (standard vent)XG40T06EC36U1, XG50T06TH40U0, XG50T06HE40U0, XG50T06TC38U1 · STATUS light next to the gas control knob. One blue blink every 3 seconds = normal. Red blinks repeated every 3 seconds = a fault code. The pilot must be lit to read codes.
- Ultra Low NOx gas tank with a status lightXG50T06EN34U0, PROG50-34U RH EC1, XG50T06EN48U0, XG75T06EN76U1 · Same STATUS light as the standard atmospheric control, plus two extra red codes (9 and 10 blinks) for the combustion-chamber sensor.
- Power-vent gas tankXG40T06PV40U0, XP50T06PV42U0, PROG50-42N RH67 PV · LED on the gas control flashes a pattern every 3 seconds (e.g. 'six flashes of two'). Models with the optional display also show a 2-digit LCD code (e.g. 45).
- Tankless “-3”: RTG, RTGH, ECO, ECOH, Ruud RUTG, RUTGHRTGH-68DVLN-3, RTGH-84DVLN-3, RTGH-90DVLN-3, RTGH-95DVELN-3, RTGH-95DVLN-3, RUTGH-95DVLN-3, ECOH160DVLN-3, ECOH180DVELN-3, ECOH200DVELN-3, RTG-70DVLN-3, RTG-84DVLN-3, RTG-95DVLN-3, RTG-95DVELN-3, RTG-70XLN-3, RTG-84XLN-3, RTG-95XLN-3, RTG-95XELN-3, RUTG-95DVLN-3, ECO160DVLN-3, ECO180DVELN-3, ECO200DVELN-3, ECO200XELN-3 · 2-character code on the built-in LED display on the front of the heater; outdoor non-condensing models can use the UMC-117 remote, which shows the same codes.
- Tankless RTG-R with built-in pumpRTG-R70DVELN-3, RTG-R95DVELN-3, RTG-R70XELN-3, RTG-R95XELN-3, RUTG-R95DVELN-3, ECOR160DVELN-3, ECOR200DVELN-3, ECOR200XELN-3 · 2- or 3-digit code on the built-in LED/WiFi display.
- Earlier tankless (up to the “-2” series)64DV/64X, 70DV/70X, 84DV/84X, 95DV/95X, 150DV/X, 160DV/X, 180DV/X, 200DV/X, 2-20R/2-25R/2-28R, H-68, H-84, H-90, H-95, H-160, H-180, H-200, H-25R, H-32R · 2-character code on the wired remote control.
- IKONIC condensing tanklessRTGH-S84i, RTGH-S10i, RTGH-S11i, RTGH-SR84i, RTGH-SR10i, RTGH-SR11i, RUTGH-S11i, RUTGH-SR11i · Code with a letter prefix (A011, A090, T113...) on the LCD User Interface; listed under SERVICE > Current Alarms.
- ProTerra heat pump (electric)PROPH50 T2 RH375-15 · Alarm code (A### or T###) under 'Current Alarm' on the control display, with a beep and a ! icon.
Common questions
Rheem error code questions
What does it mean when my Rheem water heater blinks red?
On a Rheem gas tank with a status light, red blinks are a code. Count them: 2 red blinks means the thermopile voltage is low, 4 is a high-temperature shutdown, 5 is a failed temperature sensor, 7 is a failed gas control, and 8 is a flame sense error. One blue blink every 3 seconds is normal.
How do I reset a Rheem tankless water heater?
Rheem’s owner’s manual says: turn off all hot taps, turn the heater off with the power button, wait about 5 minutes and turn it back on, then open a hot tap. If the code is still there, unplug the heater for about 30 seconds and try again. If it still shows, write down the code and call for service.
Is there a reset button for the Rheem status light?
No. Rheem says there’s no reset button for the status light. If it isn’t blinking blue, relight the pilot by following the lighting instructions on the heater. The light can only show a code while the pilot is lit.
What is the Rheem lime code?
Rheem tankless heaters show 1L when scale is building up in the heat exchanger. It isn’t LC, which is Rinnai’s code. IKONIC heaters show A01L in the owner’s manual and A018 in the service manual.
Where this comes from
Sources
Every meaning, cause and step on this page is from Rheem’s own documents, checked November 13, 2026. Page numbers are the printed page. We left out codes we only found on forums.
- Use & Care Manual With Installation Instructions for the Installer - Residential Gas - FVIR Certified Water Heaters Rheem Manufacturing Company · AP23060 · Rev 01 (PDF dated Apr 2022) · Models: XG40T06EC36U1, XG50T06TH40U0, XG50T06HE40U0, XG50T06TC38U1
- Use & Care Manual With Installation Instructions for the Installer - Residential Gas - Low NOx Emissions Water Heaters, FVIR Certified (SCAQMD Rule 1121 10 ng/J) Rheem Manufacturing Company · AP23699 · not printed (PDF dated Jul 2023) · Models: XG50T06EN34U0 (Performance Ultra Low NOx skinny)
- Use & Care Manual - Residential Gas - Low NOx Emissions Water Heaters (SCAQMD Rule 1121 10 ng/J) - Professional Classic skinny Rheem Manufacturing Company · AP23698 · not printed (PDF dated Jul 2023) · Models: PROG50-34U RH EC1 (Professional Classic Ultra Low NOx skinny)
- Use & Care Manual - Residential Gas Ultra Low NOx, high-BTU models with side water connections Rheem Manufacturing Company · AP22858 · not printed (PDF dated Jul 2023) · Models: XG50T06EN48U0
- Use & Care Manual With Installation Instructions for the Installer - Residential Gas - Ultra Low NOx Emissions Water Heaters (high demand) Rheem Manufacturing Company · AP20849 · Rev 02 (PDF dated Jun 2021) · Models: XG75T06EN76U1
- Use & Care Manual With Installation Instructions for the Installer - Residential Gas - FVIR Certified (Power Vent) Rheem Manufacturing Company · AP22510 · Rev 02 (PDF dated Jun 2021) · Models: XG40T06PV40U0, XP50T06PV42U0
- Use & Care Manual With Installation Instructions for the Installer - Residential Gas - FVIR Certified (Professional Classic Power Vent) Rheem Manufacturing Company · AP22511 · Rev 02 (PDF dated Jun 2021) · Models: PROG50-42N RH67 PV
- Use & Care Manual - Residential Gas - FVIR Certified Water Heaters WITH ELECTRONIC CONTROL, Residential 40, 50 Gallon (power vent) Rheem Manufacturing Company · AP14818-1 · (11/09) · Models: 2009-era Rheem 40/50-gal power vent with electronic control (model numbers not printed in the manual)
- High and Super High Efficiency Tankless Water Heater Troubleshooting Manual Rheem Manufacturing Company, Water Heater Division · AP21822 · Rev 02 (Copyright 2025) · Models: RTGH-68/84/90/95 DV(E)L(N/P)-3, RUTGH-..-3, ECOH160/180/200..-3, RMTGH..-3, RTG-70/84/95 DV(E)L / X(E)L (N/P)-3, RUTG-..-3, ECO160/180/200..-3, RMTG..-3
- Super High Efficiency Condensing Tankless Water Heater Use and Care Manual With Installation Instructions for the Installer Rheem Manufacturing Company · AP21820 · Rev 06 (PDF dated Jan 2024) · Models: RTGH-95DVELN-3, RTGH-68/84/90/95DVL-3
- High-Efficiency Non-Condensing Tankless Water Heater Use and Care Manual With Installation Instructions for the Installer Rheem Manufacturing Company · AP22009 · Rev 06 (PDF dated Jan 2024) · Models: RTG-95DVLN-3, RTG-70/84/95 (DV/X)-3
- High Efficiency Tankless Water Heater with Recirculation Troubleshooting Manual Rheem Manufacturing Company, Water Heater Division · AP24838 · Rev 01 (Copyright 2025) · Models: RTG-R70/R95 DVEL(N/P)-3 and XEL(N/P)-3, RUTG-R..-3, ECOR160/200..-3, RMTGR..-3, FDTG-R..-3
- High-Efficiency Non-Condensing Tankless Water Heater with Recirculation Use and Care Manual Rheem Manufacturing Company · AP23962 · Rev 02 (PDF dated Jul 2025) · Models: RTG-R95DVELN-3, RTG-R70/R95 DVL-3
- Tankless Gas Troubleshooting Pocket Manual SVC 820P - For Non-Condensing & Condensing Platforms Rheem Manufacturing Company · SVC-820P · REV 3 (printed 05/19) · Models: Non-condensing 64DV/X, 70DV/X, 84DV/X, 95DV/X, 150DV/X, 160DV/X, 180DV/X, 200DV/X, 2-20R, 2-25R, 2-28R, Condensing (up to -2 models) H-68, H-84, H-90, H-95, H-160, H-180, H-200, H-25R, H-32R
- Tankless Water Heater Use and Care Manual With Installation Instructions for the Installer - Noncondensing 199,900, 180,000 and 150,000 Btu/hr Models Rheem Manufacturing Company · AP16115-1 · (8/12) · Models: 2012-era non-condensing 150k-199.9k Btu/hr (model numbers not printed)
- 94% Condensing Tankless Water Heater Use and Care Manual With Installation Instructions for the Installer - 199,900, 180,000 and 157,000 Btu/hr Models Rheem Manufacturing Company · AP15897-1 · (08/12) · Models: 2012-era condensing 157k-199.9k Btu/hr (model numbers not printed)
- Technical Training and Service Manual Pocket Guide - Tankless Water Heaters (IKONIC) Rheem Manufacturing Company · AP24727 · not printed (PDF dated Feb 2025) · Models: RTGH-S11i, RTGH-S10i, RTGH-S84i, RTGH-SR11i, RTGH-SR10i, RTGH-SR84i, RUTGH-S11i/S10i/S84i, RUTGH-SR11i/SR10i/SR84i, CRTGH-S/SR
- Condensing Tankless Water Heater Use and Care Manual With Installation Instructions for the Installer (IKONIC) - 199,900, 180,000 and 157,000 Btu/hr Models Rheem Manufacturing Company · AP22745 · Rev 07 (PDF dated Feb 2025) · Models: RTGH-S10i (product page), RTGH-S/SR series
- Use & Care Manual With Installation Instructions for the Installer - Electric Residential Hybrid Water Heater (ProTerra) Rheem Sales Company · AP23657 · Rev 04 (2024) · Models: PROPH50 T2 RH375-15 (product page)
Other brands
Error codes for other water heaters
Water heater help
More about water heaters
Code won’t clear?
If you’re within about 30 miles of Westlake Village, call or text Dan a photo of the display and the label. He’ll tell you what it is.
Or send the details and Dan will call you back. Monday to Friday, 9am – 5pm.