The fuel-and-air mix is off, so the heater shut itself down. It’s usually the air supply, the exhaust, the gas supply or a clogged condensate drain, and you can check some of that yourself.
Smell gas? Don’t touch any switch or try to reset anything. Leave the house, then call 911 or your gas company from outside. In Southern California that’s SoCalGas, 1-800-427-2200.
From Dan and Dave at Dan's Plumbing, a family plumbing shop in Westlake Village, California. We install Noritz heaters. Everything below comes from Noritz’s own documents, cited line by line.
What it means
What Noritz says code 90 means
“Combustion abnormality (Unit shuts off)”— Service Manual - Condensing Tankless Gas Water Heater (EZ111DV, EZ98DV, EZ71DV, NRCR111DV, NRCR92DV, NCC199CDV), page 45
Noritz calls code 90 a “combustion abnormality.” The fuel-and-air mix is off, so the heater shut itself down. It’s struggling to pull in air, push out exhaust or get enough gas. On condensing models, a clogged or frozen condensate drain can cause it too.
Noritz’s Help Center says that on a new install, 90 usually comes from low gas pressure, the wrong venting, a bad condensate drain install, or the wrong elevation and vent settings. On an older install, it’s usually a dirty heater or a clogged condensate drain.
On today’s EZ series, 90 only clears when the power is disconnected and reconnected. If it’s detected 30 times, the heater locks out with 908 and a technician has to reset it.
Model differences. Meaning is the same in every family that uses it (combustion / air-flow abnormality), but details differ: GQ-61 adds sub-codes 90-1, 90-2, 90-8 and locks (908) after 30 detections; GQ-57, 2012 and 2008-2011 models can show 90 first as a warning while still running, then shut off; display-window models show 901/902/903/908 on the unit and 90 on the remote; on GQ-61/GQ-60/GQ-59/NRCB code 10 is the early warning. NRCP models do not use 90 at all.
Why it happens
Likely causes of Noritz code 90
Air supply vent may be clogged (when combustion air comes from indoors); exhaust vent may be clogged; abnormal combustion or low gas supply pressure; condensate drain line may be clogged. (GQ-61 owner’s guide (2025), p. 31)
Unit detected abnormal air flow when it started; a gas with too low a heating value can also cause it. (GQ-61 service manual (2026), p. 92)
New installs: low gas heating value, low gas pressure, wrong venting, bad condensate drain install, wrong elevation / vent size / vent length settings. Older installs: usually a dirty unit or clogged condensate drain. (Noritz Help Center: 90 (Pro))
Fan speed (maintenance monitor 49) above 100 means trouble moving air in or out; outlet temperature (monitor 31) well below set point means not enough gas reaches the burner. A lint-filled fan can cause 90. (Noritz Help Center: 90)
GQ-57: fan speed raised to 103% gives a warning while running; 104% stops combustion. (GQ-57 service manual (2018), p. 40)
2008-2011 models: fan speed raised 110% (N-0631S -OD 115%) gives a warning; more makes combustion stop. (Service manual (2011), p. 62)
Display-window models: 90 on the remote is shown as 901 / 903 / 908 (air flow or combustion) or 902 (low gas pressure) on the unit window. (NRC711 owner’s guide (2017), p. 25)
2002 N-132: combustion abnormality where the burner sensor detects high temperature, or BTU drop. (N-132 service manual (2002), p. 15)
What to do
Safe checks first. Then call a pro.
Safe checks you can do
1
If the heater takes combustion air from inside the house, look at the air supply vent for dust, lint or oil and clean it with a vacuum or damp towel. Do not remove the inlet screen. (GQ-61 owner’s guide (2025), pp. 26, 31)
2
Look at the exhaust vent and its outside end for anything blocking it. (GQ-61 owner’s guide (2025), p. 31)
Have a professional check the gas supply pressure. If the code keeps coming back, contact the nearest Noritz agent. (GQ-61 owner’s guide (2025), p. 31)
5
GQ-60 EZ: check the air supply vent (indoor air), the exhaust vent, and the condensate drain line for clogging or freezing; have a professional check gas pressure. (GQ-60 owner’s guide (2021), p. 18)
6
GQ-59 EZ: same checks - air supply vent, exhaust vent, condensate drain line. (GQ-59 owner’s guide (2021), p. 28)
7
GQ-57 and 2012 condensing: clean the air supply vent (indoor air). If the display continues, contact the nearest Noritz agent. (NRC111 GQ-57 owner’s guide (2017), p. 28)
Display-window models: clean the air supply vent; NRC663 (EZTR40): clean the air inlet filter. (NRC663 owner’s guide (2017), p. 24)
10
2008-2011 and 2005 non-condensing: have a professional check gas supply pressure; contact the nearest Noritz agent. (NR111 owner’s guide (2009), p. 25)
11
NRCB combi boiler: check the air supply vent, exhaust vent and condensate drain line; have a professional check gas pressure. (NRCB owner’s guide (2021), p. 36)
To clear the code:
Codes such as 20, 65, 70, 71, 73, F76, 90, 91 and 94 reset only when electrical power is disconnected and reconnected. After fixing a 90, disconnect power, wait 20 seconds, then reconnect. (GQ-61 service manual (2026), pp. 45, 92)
Press the button to turn the water heater off, open a hot water tap, and turn the water heater back on. If the blinking number does not return, the problem is solved. (GQ-60 owner’s guide (2021), p. 18)
Press the power button to turn the unit off, open a hot water tap, and turn the unit back on. If the flashing number does not return, the problem is solved. (NRC111 GQ-57 owner’s guide (2017), p. 28)
Unplug the unit from power or press the power button on the optional remote to turn it off, open a hot water tap, and turn the unit back on. (NRC661 owner’s guide (2013), p. 25)
What a technician checks, and why
Check air intake, exhaust and the intake air filter inside the unit for blockage. After fixing, disconnect power, wait 20 seconds, reconnect.Opens the cabinet / needs meters or service mode (GQ-61 service manual (2026), p. 92)
Check the condensate drain line (clogged, frozen) and that the drain pipe slopes down.Drain piping repair is plumbing work (GQ-61 service manual (2026), p. 92)
Check installation settings: common vent, vent type, elevation, vent length, vent size (installation manual).Installer settings in service menus (GQ-61 service manual (2026), p. 92)
Measure inlet gas pressure while the heater runs at full fire. Natural gas 3.5-10.5 in. W.C.; propane 8-13 in. W.C.Gas pressure and gas-valve work need a qualified service technician (GQ-61 service manual (2026), p. 92)
Check Thermistor-Heat Exchanger Outlet: in Drain Mode with water flowing, maintenance monitors #30 and #32 should agree within ±5°F; check resistance at CN63.Circuit board, wiring and sensors are inside the cabinet (GQ-61 service manual (2026), pp. 92-93)
GQ-61 lockout 908 (after 90 is detected 30 times): after fixing the cause, reset maintenance writer #5F from ON to OFF.Service-mode setting (GQ-61 service manual (2026), pp. 92, 98)
Run the unit and read maintenance monitors 31 (outlet temp) and 49 (fan speed); clean a lint-filled fan.Opens the cabinet / needs meters or service mode (Noritz Help Center: 90)
Run the unit at low, medium and high flow with other gas appliances on while watching inlet gas pressure on a manometer.Gas pressure and gas-valve work need a qualified service technician (Noritz Help Center: 90 (Pro))
GQ-60 / GQ-59: check vents, gas pressure, condensate drain and slope, and the DIP switch settings on the circuit board.Opens the cabinet / needs meters or service mode (GQ-60 technical sheet, p. 1)
GQ-57: check for abnormal combustion, flue and air inlet blockage, and that flame lights all across the burner; read maintenance monitor No. 49 for fan speed.Opens the cabinet / needs meters or service mode (GQ-57 service manual (2018), pp. 35, 40)
2012 series: check for abnormal combustion, flue blockage, flame across the burner; reset by disconnecting power.Opens the cabinet / needs meters or service mode (Service manual (2012), pp. 40-42)
2008-2011 series: check maintenance monitors No. 48 and 49 for fan speed; check combustion and flue.Opens the cabinet / needs meters or service mode (Service manual (2011), p. 62)
Display-window models: 90 = air flow abnormality; check flue and air inlet for blockage.Opens the cabinet / needs meters or service mode (Service manual (2013), p. 28)
2002 N-042/N-063: visually check flame quality, check flue for blockage, check wiring to the gas solenoid valves.Gas pressure and gas-valve work need a qualified service technician (N-042 service manual (2002), p. 21)
NRCB: check air supply and exhaust vents, condensate drain slope and clogging, gas supply pressure, and DIP switch settings; reset by disconnecting power.Opens the cabinet / needs meters or service mode (NRCB service manual (2020), p. 19)
Please don’t
Don’t open the burner, the gas valve or the sealed combustion chamber.
Don’t keep resetting a code that keeps coming back. A code that returns means the cause is still there.
Don’t bypass or unplug a safety sensor to get hot water back.
Don’t cover, tape or move the vent or the air intake.
A tankless water heater in a Malibu garage closet wasn’t getting enough air. Dan and Dave installed a new Noritz exterior vent and the error code stopped.
Rheem 90The heater found a blocked vent before lighting.
Common questions
Noritz code 90 questions
Can I fix Noritz error code 90 myself?
Some of it. Noritz’s owner’s guide lets you clean the air supply vent if the heater takes its air from inside the house, look at the exhaust vent and its outside end for anything blocking it, and check that the condensate drain line isn’t clogged or frozen. Gas pressure, the fan and the heater’s settings are for a technician.
What do 901, 902, 903 and 908 mean on a Noritz?
On older display-window models, the unit’s window shows code 90 as 901, 903 or 908 for an air flow or combustion problem, and 902 for low gas pressure. On current EZ models, 908 is the lockout after 90 has been detected 30 times.
Can a dirty fan cause Noritz code 90?
Yes. Noritz’s Help Center says a fan full of lint can cause 90. A technician reads the fan speed in the maintenance monitor and cleans it.
Where this comes from
Sources
Taken from Noritz’s own documents, checked November 13, 2026. Page numbers are the printed page. Where models differ, we say which model each part applies to.