Rinnai · Error code 63 · Checked November 2026
Rinnai error code 63: recirculation low flow
The recirculation loop isn’t moving enough water. Air in the lines, dirty filters, closed valves or wrong settings are the usual reasons.
Smell gas? Don’t touch any switch or try to reset anything. Leave the house, then call 911 or your gas company from outside. In Southern California that’s SoCalGas, 1-800-427-2200.
From Dan and Dave at Dan's Plumbing, a family plumbing shop in Westlake Village, California. Everything below comes from Rinnai’s own documents, cited line by line.
What it means
What Rinnai says code 63 means
“Recirculation Low Flow”— Troubleshooting Tankless Water Heater Diagnostic Codes, page 53
Code 63 means the recirculation loop isn’t moving enough water. It shows on Rinnai heaters with a built-in pump, like the RUR and RXP, and on heaters set up to recirculate hot water through the house.
Rinnai’s guide lists air in the lines, dirty inlet or bypass filters, closed valves, the wrong bypass setup for the recirculation mode, a pump with no power, and a plumbing leak that lets the pump pull in air.
Model differences. RH180: flow below 1.3 GPM — bleed air, clean filters, 30–50 psi supply (guide p. 54). Listed in RU, RUR, RSC, CU and RX/CX tables, RE/REP and KBP; not in Value, KBD or KCM tables.
On other Rinnai models, 63 means something else:
- FC06 Ball-valve errorThe automatic water shut-off valve (leak kit) is not working. On: REHP heat pump water heater (tank).
Why it happens
Likely causes of Rinnai code 63
- Bypass plug/filter wrong for the recirculation mode; dirty inlet or bypass filters; closed valves; air in the loop. (Diagnostic codes guide (2024), p. 53)
- Pump not getting 120 VAC; loop too long; wrong Parameter 04/05 (or 04 set to B with no pump connected on SENSEI/RX/CX). (Diagnostic codes guide (2024), p. 54)
- A leak in the building plumbing letting the pump pull in air. (Diagnostic codes guide (2024), p. 54)
What to do
Safe checks first. Then call a pro.
Safe checks you can do
Make sure the cold water inlet and hot water outlet valves at the heater are open. (Diagnostic codes guide (2024), p. 53)
What a technician checks, and why
- Shut off and drain, then clean inlet and bypass filters; set bypass plug/filter for the mode; bleed air from the loop.Requires removing the front cover and working inside the cabinet. (Diagnostic codes guide (2024), p. 53)
- Check pump voltage; verify Parameters 04/05 (SENSEI/RX/CX) or DIP switches (Non-SENSEI); RX/CX pump speed Max (16A), loop flow above 0.4 GPM.Parameter/DIP switch settings and PC board work are on the board inside the cabinet. (Diagnostic codes guide (2024), pp. 53–54)
- Isolate with a 50–100 ft hose loop to tell heater vs. building; pressure-test the building for leaks.Plumbing diagnosis with gauges and valve-kit work. (Diagnostic codes guide (2024), p. 54)
- Loop equivalent length max 400 ft of 3/4 in. or 100 ft of 1/2 in.Vent system changes and vent-length/DIP settings are installer work. (Diagnostic codes guide (2024), p. 54)
- KBP RUR98: inspect/clean inlet and pump filters, purge air, replace pump.Shaded 'licensed professional only' in the manual. (RUR98 manual, p. 75)
Please don’t
- Don’t open the burner, the gas valve or the sealed combustion chamber.
- Don’t keep resetting a code that keeps coming back. A code that returns means the cause is still there.
- Don’t bypass or unplug a safety sensor to get hot water back.
- Don’t cover, tape or move the vent or the air intake.
Heater getting old, or the same code keeps coming back? Repair or replace? Three taps and Dan’s answer → Or see what a water heater repair usually involves.
Where this comes from
Sources
Taken from Rinnai’s own documents, checked November 13, 2026. Page numbers are the printed page. Where models differ, we say which model each part applies to.
- Troubleshooting Tankless Water Heater Diagnostic Codes Rinnai America Corporation · 100000652 · file '100000652-Troubleshooting TWH Diagnostic Codes (3).pdf', PDF dated 2024-05-08; byte-identical to the library’s 'TWH Troubleshooting Technical Data Sheet' · Models: RU/RUR/RSC/CU SENSEI, RX/RXP/CX/CXP SENSEI RX/CX, RE/REP (VE), V53e/V53De/V65/V75/V94/V94X (VC Value), RL75/RL94/RLX94 (VC Luxury, VB), R50LS/R63LS/R75LS/R94LS/R98LS (VA), RC80/RC98 (KA), RU80/RU90/RU98, RUC80/90/98, C199 (KB/KBD), RUR98 (KBP), RUCS65/75, RUS65/75 (KCM), RH180 (HTT)
- Direct Vent Tankless Water Heater with Integrated Pump Installation and Operation Manual — KBP Series (RUR98i/RUR98e) Rinnai America Corporation · 100000379 / U306-1465X03(00) · (03), ©2017 · Models: RUR98i, RUR98e
Water heater help
More about water heaters
Code won’t clear?
If you’re within about 30 miles of Westlake Village, call or text Dan a photo of the display and the label. He’ll tell you what it is.
Or send the details and Dan will call you back. Monday to Friday, 9am – 5pm.