Rinnai · Error code 63 · Checked November 2026

Rinnai error code 63: recirculation low flow

The recirculation loop isn’t moving enough water. Air in the lines, dirty filters, closed valves or wrong settings are the usual reasons.

Smell gas? Don’t touch any switch or try to reset anything. Leave the house, then call 911 or your gas company from outside. In Southern California that’s SoCalGas, 1-800-427-2200.

Dan and Dave of Dan's Plumbing in front of their work truck

From Dan and Dave at Dan's Plumbing, a family plumbing shop in Westlake Village, California. Everything below comes from Rinnai’s own documents, cited line by line.

What it means

What Rinnai says code 63 means

“Recirculation Low Flow”— Troubleshooting Tankless Water Heater Diagnostic Codes, page 53

Code 63 means the recirculation loop isn’t moving enough water. It shows on Rinnai heaters with a built-in pump, like the RUR and RXP, and on heaters set up to recirculate hot water through the house.

Rinnai’s guide lists air in the lines, dirty inlet or bypass filters, closed valves, the wrong bypass setup for the recirculation mode, a pump with no power, and a plumbing leak that lets the pump pull in air.

Model differences. RH180: flow below 1.3 GPM — bleed air, clean filters, 30–50 psi supply (guide p. 54). Listed in RU, RUR, RSC, CU and RX/CX tables, RE/REP and KBP; not in Value, KBD or KCM tables.

On other Rinnai models, 63 means something else:

  • FC06 Ball-valve errorThe automatic water shut-off valve (leak kit) is not working. On: REHP heat pump water heater (tank).

Why it happens

Likely causes of Rinnai code 63

What to do

Safe checks first. Then call a pro.

Safe checks you can do

  1. Make sure the cold water inlet and hot water outlet valves at the heater are open. (Diagnostic codes guide (2024), p. 53)

What a technician checks, and why

  • Shut off and drain, then clean inlet and bypass filters; set bypass plug/filter for the mode; bleed air from the loop.Requires removing the front cover and working inside the cabinet. (Diagnostic codes guide (2024), p. 53)
  • Check pump voltage; verify Parameters 04/05 (SENSEI/RX/CX) or DIP switches (Non-SENSEI); RX/CX pump speed Max (16A), loop flow above 0.4 GPM.Parameter/DIP switch settings and PC board work are on the board inside the cabinet. (Diagnostic codes guide (2024), pp. 53–54)
  • Isolate with a 50–100 ft hose loop to tell heater vs. building; pressure-test the building for leaks.Plumbing diagnosis with gauges and valve-kit work. (Diagnostic codes guide (2024), p. 54)
  • Loop equivalent length max 400 ft of 3/4 in. or 100 ft of 1/2 in.Vent system changes and vent-length/DIP settings are installer work. (Diagnostic codes guide (2024), p. 54)
  • KBP RUR98: inspect/clean inlet and pump filters, purge air, replace pump.Shaded 'licensed professional only' in the manual. (RUR98 manual, p. 75)

Please don’t

  • Don’t open the burner, the gas valve or the sealed combustion chamber.
  • Don’t keep resetting a code that keeps coming back. A code that returns means the cause is still there.
  • Don’t bypass or unplug a safety sensor to get hot water back.
  • Don’t cover, tape or move the vent or the air intake.

Heater getting old, or the same code keeps coming back? Repair or replace? Three taps and Dan’s answer → Or see what a water heater repair usually involves.

Where this comes from

Sources

Taken from Rinnai’s own documents, checked November 13, 2026. Page numbers are the printed page. Where models differ, we say which model each part applies to.

  1. Troubleshooting Tankless Water Heater Diagnostic Codes Rinnai America Corporation · 100000652 · file '100000652-Troubleshooting TWH Diagnostic Codes (3).pdf', PDF dated 2024-05-08; byte-identical to the library’s 'TWH Troubleshooting Technical Data Sheet' · Models: RU/RUR/RSC/CU SENSEI, RX/RXP/CX/CXP SENSEI RX/CX, RE/REP (VE), V53e/V53De/V65/V75/V94/V94X (VC Value), RL75/RL94/RLX94 (VC Luxury, VB), R50LS/R63LS/R75LS/R94LS/R98LS (VA), RC80/RC98 (KA), RU80/RU90/RU98, RUC80/90/98, C199 (KB/KBD), RUR98 (KBP), RUCS65/75, RUS65/75 (KCM), RH180 (HTT)
  2. Direct Vent Tankless Water Heater with Integrated Pump Installation and Operation Manual — KBP Series (RUR98i/RUR98e) Rinnai America Corporation · 100000379 / U306-1465X03(00) · (03), ©2017 · Models: RUR98i, RUR98e

Water heater help

More about water heaters

Dan standing in front of his white work truck, smiling

Code won’t clear?

If you’re within about 30 miles of Westlake Village, call or text Dan a photo of the display and the label. He’ll tell you what it is.

Or send the details and Dan will call you back. Monday to Friday, 9am – 5pm.

Find us

Dan's Plumbing

2352 Hillsbury Rd
Westlake Village, CA 91361

(805) 330-3111 · Monday to Friday, 9am – 5pm

Serving Westlake Village, Thousand Oaks, Agoura Hills, Oak Park and Lake Sherwood. Zip codes 91361, 91362, 91360, 91320, 91301, 91377, 91302, 90265.

Dan (left) and Dave. Family run since 1977. One of them does the work.