Navien error codes, in plain words
Navien codes are an E and three digits, like E003. Here’s every code in Navien’s manuals for its tankless water heaters and combi-boilers, in plain words. A few numbers mean different things on a water heater and a boiler, and some popular websites get them wrong, so check which model you have.
From Dan and Dave at Dan's Plumbing, a family plumbing shop in Westlake Village, California. Every line below comes from Navien’s own documents, with the page it’s on.
Smell gas? Don’t touch any switch or try to reset anything. Leave the house, then call 911 or your gas company from outside. In Southern California that’s SoCalGas, 1-800-427-2200.
Every code
All 54 Navien codes
Tankless water heaters: NPE-A2/S2, NPE-A/S, NPN, NHW700
These show on Navien’s tankless water heaters. Most also show on its combi-boilers.
-
The burner did not light.Ignition failure
The burner did not light. The heater tried to ignite the gas and never saw a flame. (NPE-2 user’s manual, p. 17)
By model: Same meaning on every Navien family. The NPN manual adds a gas-type match check (gas manifold and fuel DIP switch). The NHB-H/NFB-H boiler manuals add the igniter.
Likely causes
- Gas supply problem: valve closed, low supply pressure (LP pressure drops often in winter), an undersized flex line, an over-tightened CSST connector whose seal blocks gas flow, or a gas meter too small for the heater plus the home's other gas appliances. (NPE-2 service manual (2025), p. 78)
- Igniter electrode gap wrong or electrode bent; the spark can look normal through the window and still fail, so the gap must be checked after taking it apart. (NPE-2 service manual (2025), p. 78)
- No spark: cracked electrode insulator, spark jumping to the burner, missing insulating gasket, a bad ignition transformer, or no power to the transformer from the PCB. (NPE-2 service manual (2025), p. 79)
- Main gas valve not opening: no DC 22-24 V from the PCB, open coil, or a solenoid that does not click. (NPE-2 service manual (2025), p. 80)
- Flame not sensed: flame rod dirty, bent or badly wired, or a poor ground at the case. (NPE-2 service manual (2025), p. 80)
- Clogged gas orifices, rainwater collected inside from a badly installed intake pipe, loose ground screws on the heat exchanger, or a bad PCB. (NPE-2 service manual (2025), p. 81)
- NPN adds: manifold solenoid valve not working and a gas type/manifold mismatch. (NPN service manual (2025), pp. 80, 83-84)
What you can check
- Make sure the main gas supply valve to the heater is open. (NPE-2 user’s manual, p. 17)
- Then press the Back button to reset (NPE-A2/S2). Other models: see the reset section. (NPE-2 user’s manual, p. 16)
For a technician
- Make sure the gas manifold and the fuel-type DIP switch setting match the gas supplied (natural gas vs. propane). (NPN user’s manual, p. 22)
- Check the gas supply valve and the igniter. (NHB-H user’s manual, p. 24)
- Measure gas supply pressure with a manometer, both static (standby) and dynamic (full fire, PCB DIP 1-1 ON). Normal: natural gas 3.5-10.5 in. W.C., propane 8-13 in. W.C. (NPE-2 service manual (2025), pp. 77-78)
- Check that the gas meter is big enough for every gas appliance at once (manual's example: 425 CFH meter >= 195 CFH heater + 58.8 CFH furnace + 63.7 CFH range; 1 CFH = 1,020 Btuh). (NPE-2 service manual (2025), p. 78)
- Remove and inspect the igniter: electrode gap about 3-4 mm (1/8 in.), no cracked insulator, insulating gasket in place, spark wire boots not cracked. (NPE-2 service manual (2025), pp. 78-79)
- Check the ignition transformer gets AC 102-132 V. If it does and there is no spark, replace the transformer; if it does not, replace the PCB. (NPE-2 service manual (2025), p. 79)
- Check the main gas valve gets DC 22-24 V; replace the PCB if not. If power is normal, check for an open coil and listen or feel for the solenoid click. (NPE-2 service manual (2025), p. 80)
- Check the flame rod for position, deformation and debris, its wire, and the case ground; flame current should be about 3-4 microamps. (NPE-2 service manual (2025), p. 80)
- Check the PCB DIP switches, adjust the offset pressure, check the gas orifice plate is right for the gas type, check the APS hose is not broken or clogged, and check the APS works. (NPE-2 service manual (2025), p. 76)
- Remove the gas inlet pipe and inspect the orifice plate for blockage; check for rainwater inside the unit from the intake pipe; tighten the heat exchanger ground screws. (NPE-2 service manual (2025), p. 81)
- If nothing above fixes it: call Navien Technical Support (NPE-A2/S2 manual); the NPE-A/S and NPN manuals say replace the PCB. (NPE-2 service manual (2025), pp. 76 (npe-sm p. 78; npn-sm p. 80))
- NPN: check that the manifold solenoid valves work and that the gas type and manifold match. (NPN service manual (2025), pp. 80, 83-84)
-
The heater sensed a flame when there should not be one.False flame detection
The heater sensed a flame when there should not be one. Navien’s first check is the electrical ground. (NPE-2 user’s manual, p. 17)
By model: Same meaning and same first step on all families.
Likely causes
- Main gas valve seal leaking so a flame appears before or after firing. (NPE-2 service manual (2025), p. 82)
- Spark jumping from the electrode to the flame sensor. (NPE-2 service manual (2025), p. 82)
- Supply gas pressure above standard pushing the gas valve open. (NPE-2 service manual (2025), p. 82)
- Bad PCB, or (NPN) poor grounding of the shell. (NPN service manual (2025), p. 85)
What you can check
- Make sure the heater’s electrical cord is properly grounded (Navien’s owner’s manual step). (NPE-2 user’s manual, p. 17)
For a technician
- Check for gas leaking through the main gas valve; replace the gas valve if a flame shows before firing or stays after firing stops. (NPE-2 service manual (2025), p. 82)
- Fix or move the flame rod if the spark jumps to it. (NPE-2 service manual (2025), p. 82)
- Check supply pressure (NG 3.5-10.5 in. W.C., LP 8-13 in. W.C.). If it is too high, tell the gas supplier and replace the gas valve if needed. (NPE-2 service manual (2025), p. 82)
- Make sure the ground wire is connected and the igniter sparks. (NPE-2 service manual (2025), p. 73)
- If a gas leak is found, close the gas supply valve and repair before anyone uses the heater. (NPE-2 service manual (2025), p. 82)
-
The burner lit, then the flame went out while the heater was running.Flame loss
The burner lit, then the flame went out while the heater was running. (NPE-2 user’s manual, p. 17)
By model: Same meaning on all families. NPN adds a gas-type match check. The NPN owner’s manual says 'See page 19' for the intake air filter, but its page 19 covers the cold water inlet filter; the NPN owner’s manual has no air intake filter section. NHB-H/NFB-H boilers point to gas, venting and the condensate trap.
Likely causes
- Low gas supply pressure, often while another gas appliance runs (check dynamic pressure); LP drops in winter; an over-tightened CSST connector; a gas meter too small; or packing push-out/thread tape blocking flow at an over-tightened nut. (NPE-2 service manual (2025), p. 84)
- Flame rod coated with oxide after long high-heat use. (NPE-2 service manual (2025), p. 85)
- Loose screws or ground bolt between the chamber and the heat exchanger. (NPE-2 service manual (2025), p. 85)
- Debris in, or sagging of, the burner's metal fiber (gap to the electrode should be 12 mm). (NPE-2 service manual (2025), p. 85)
- Clogged gas orifices (flame loss during 2nd stage); dual venturi not working; bad PCB. (NPE-2 service manual (2025), pp. 83, 85)
- NPN: wrong PCB DIP settings, low-stage gas pressure set wrong, or a bad manifold. (NPN service manual (2025), p. 86)
What you can check
- Clean the air intake filter. Navien’s owner’s manual has you turn the heater off, unplug it, remove the front cover and the one screw holding the filter, rinse it, let it dry and put it back. Navien says to do this every 3-4 months. (NPE-2 user’s manual, pp. 14, 17)
- Make sure the heater’s electrical cord is properly grounded (Navien’s owner’s manual step). (NPE-2 user’s manual, p. 17)
For a technician
- Make sure the gas manifold and the fuel-type DIP switch setting match the gas supplied. (NPN user’s manual, p. 22)
- Check gas, venting and the condensate trap. (NHB-H user’s manual, p. 24)
- Measure supply gas pressure with a manometer, static and at max fire (NG 3.5-10.5 in. W.C., LP 8-13 in. W.C.); check the gas meter capacity and the gas connector. (NPE-2 service manual (2025), pp. 83-84)
- Check the low-fire offset values. (NPE-2 service manual (2025), p. 84)
- Clean the flame rod with sandpaper or replace the flame rod assembly; check the flame value [J] in DIAGNOSTIC mode. (NPE-2 service manual (2025), pp. 73, 85)
- Tighten the 3 assembly screws, then the 2 ground screws, on the front of the heat exchanger. (NPE-2 service manual (2025), p. 85)
- Inspect the metal fiber burner for debris and sagging (12 mm gap to the electrode); remove and clean the gas orifice plate if needed. (NPE-2 service manual (2025), p. 85)
- Check the ground wire and the power supply. (NPE-2 service manual (2025), p. 73)
- NPN: check the manifold, the gas valve and the APS, and the PCB DIP switches. (NPN service manual (2025), pp. 78, 86)
-
The heat exchanger got too hot and the heater shut down to protect itself.Overheating of heat exchanger
The heat exchanger got too hot and the heater shut down to protect itself. Navien’s fixes point to a dirty inlet filter and scale buildup inside the heat exchanger. (NPE-2 user’s manual, p. 17)
By model: The NPE-A2/S2 owner’s manual table leaves out the '30 minutes off' step, but the NR-21DU remote manual (used with NPE-A2/S2) and the NPE-A/S, NPN, NCB-E and NCB-H tables include it. NCB-E says clean the heating return filter instead of the cold water inlet filter. NCB-H/NCB700/NHB-H/NFB-H name it 'Heat Exchanger Overheat' (the same name they give E001).
Likely causes
- Bad high limit switch (normal about 0.3 ohm; open = bad) or a broken switch wire. (NPE-2 service manual (2025), p. 87)
- Hot water outlet sensor reading lower than the real temperature. (NPE-2 service manual (2025), p. 87)
- Water adjustment valve problem, scale in the heat exchanger, or (A models) pump not running. (NPE-2 service manual (2025), p. 73)
- NPE-A/S: max-fire DIP switch 1-1 left ON, or wrong PCB DIP capacity setting, can suddenly raise water temperature; heavy scale on the primary heat exchanger. (NPE service manual (2020), p. 90)
- NPN: bad high limit switch or hot water thermistor, external pump power or wiring, high-stage gas pressure set wrong, wrong DIP capacity setting, heavy scale. (NPN service manual (2025), p. 87)
What you can check
- Turn the heater off for at least 30 minutes, then turn it back on. (NPE user’s manual, pp. 16 (also NR-21DU remote p. 30, NPN p. 22, NCB-E p. 22, NCB-H p. 25))
- Clean the cold water inlet filter. Navien’s owner’s manual has you drain the heater first (close the gas valve and cold water supply valve, open hot faucets), then rinse the filter and put it back. (NPE-2 user’s manual, pp. 11-13, 17)
- NCB-E combi-boiler only: clean the heating return filter. (NCB-E user’s manual, p. 22)
For a technician
- Flush (descale) the heat exchanger with a circulation pump, hoses, a 5-gallon bucket and cleaning solution through the service valves, at least 45 minutes, then rinse 5 minutes. (NPE-2 user’s manual, pp. 12-13, 17)
- Check heating-system flow and clean the system filters. (NHB-H user’s manual, p. 24)
- Check the high limit switch for continuity: normal about 0.3 ohm (component page: under 1.0 ohm); replace it if open. (NPE-2 service manual (2025), pp. 59, 87)
- Compare the outlet temperature on the front panel with actual and measure the outlet sensor resistance. (NPE-2 service manual (2025), p. 87)
- Check the water adjustment valve, PCB DIP switches and (A models) pump operation; flush the heat exchanger if scaled. (NPE-2 service manual (2025), p. 73)
- NPE-A/S: set DIP 1-1 back to normal operation and check the PCB DIP capacity setting for the model. (NPE service manual (2020), p. 90)
- NPN: check external pump power and resistance, and adjust the high-stage gas pressure. (NPN service manual (2025), p. 87)
-
The exhaust (flue) gas got too hot.Exhaust overheating
The exhaust (flue) gas got too hot. The heater shuts down when the flue temperature goes above 149 °F (65 °C). (NPE-2 user’s manual, p. 17)
By model: Not listed in the NPN (non-condensing) owner’s manual table, although the NR-21DU remote manual (which covers NPE-A2/S2 and NPN) lists it. On water heaters the owner steps are filter cleaning and flushing; on combi-boilers Navien says call Technical Support.
Likely causes
- Flue (exhaust) temperature above 149 °F (65 °C). (NPE-2 user’s manual, p. 17)
- Damaged or scale-clogged heat exchanger raising exhaust temperature. (NPE service manual (2020), p. 92)
- Bad exhaust overheat controller (230 °F / 110 °C max) contact or connection, or a bad PCB. (NPE service manual (2020), p. 92)
- Exhaust thermistor not working. (NPE-2 service manual (2025), p. 90)
- Leak in the combustion chamber. (NPE-2 service manual (2025), p. 90)
What you can check
- Turn the heater off for at least 30 minutes, then turn it back on (NPE-A/S and NR-21DU remote manuals). (NPE user’s manual, p. 16)
- Clean the cold water inlet filter. Navien’s owner’s manual has you drain the heater first (close the gas valve and cold water supply valve, open hot faucets), then rinse the filter and put it back. (NPE-2 user’s manual, pp. 11-13, 17)
- Combi-boilers (NCB-E, NCB-H, NCB700): call Navien Technical Support at 1-800-519-8794. (NCB-H user’s manual, p. 25)
For a technician
- Flush (descale) the heat exchanger. (NPE-2 user’s manual, pp. 12-13, 17)
- Check heating-system flow and clean system filters. (NHB-H user’s manual, p. 24)
- Check the exhaust thermistor and its [K] value in DIAGNOSTIC mode; check the DIP switches and water adjustment valve. (NPE-2 service manual (2025), p. 73)
- Check the heat exchanger and the combustion chamber for leaks; flush the heat exchanger. (NPE-2 service manual (2025), p. 90)
- Flush to remove scale; replace the heat exchanger if it is damaged or will not unclog. (NPE service manual (2020), p. 92)
-
The burner area got too hot.Overheating of burner
The burner area got too hot. (NPE-2 user’s manual, p. 17)
By model: Listed on NPE-A2/S2, NCB-H and NFB-H. Not in the NPE-A/S, NPN, NCB-E, NCB700 or NHB-H tables.
Likely causes
- Burner overheating fuse tripped. (NPE-2 service manual (2025), p. 73)
- NPN: burner fuse (sub code 0). (NPN service manual (2025), p. 78)
What you can check
- Call Navien Technical Support at 1-800-519-8794. The manual lists no owner fix for this code. (NPE-2 user’s manual, p. 17)
For a technician
- Check the burner temperature fuse. (NFB-H user’s manual, p. 23)
- Check the burner overheating fuse, then follow the E016 and E030 checks. (NPE-2 service manual (2025), p. 73)
- NPN: check the burner fuse. (NPN service manual (2025), p. 78)
-
Water heaters: the heater found a fault in its high-limit (overheat) control.Abnormal operation: limit control
Water heaters: the heater found a fault in its high-limit (overheat) control. Combi-boilers NCB-H/NCB700 and NHB/NFB boilers use E046 for a heat exchanger temperature sensor fault. (NPE-2 user’s manual, p. 17)
By model: Wording differs by family: 'limit control' on NPE-A2/S2, NPE-A/S, NPN and NCB-E; 'Heat Exchanger Thermistor' on NCB-H, NCB700, NHB-H and NFB-H.
Sub-codes
- E046-2 (limit control). (NPE service manual (2020), p. 75)
Likely causes
- NPE: heat exchanger thermistor connection or resistance fault, or a poor PCB connection. (NPE-2 service manual (2025), p. 73)
- NPN: the heat exchanger high limit switch signal stays on more than 15 seconds while water is below 60 °C, or a high limit switch fault before firing or at post-purge; caused by a bad or damaged high limit switch, shorted wiring, or a bad PCB. Clears when the signal goes away. (NPN service manual (2025), p. 88)
What you can check
- Call Navien Technical Support at 1-800-519-8794. The manual lists no owner fix for this code. (NPE-2 user’s manual, p. 17)
For a technician
- Check the thermistor connector. (NHB-H user’s manual, p. 24)
- Check the heat exchanger thermistor connector and resistance. Resistance OK: flush and clean the filter, restart, then replace the PCB if needed. Resistance bad: replace the thermistor. (NPE-2 service manual (2025), pp. 73, 91)
- NPN: check the high limit switch wiring and resistance and that it sits in the right position; replace a bad switch, then the PCB if needed. (NPN service manual (2025), pp. 78, 88)
-
The exhaust temperature sensor is reading open or shorted, so the heater cannot trust its flue temperature.Exhaust thermostat: thermistor open or short circuit
The exhaust temperature sensor is reading open or shorted, so the heater cannot trust its flue temperature. (NPE-2 user’s manual, p. 17)
By model: Not in the NPN owner’s manual table. Older manuals say 'exhaust thermostat'; the NPE-A2/S2 manual clarifies it is the exhaust thermistor reading open or short.
Sub-codes
- E047-1 exhaust thermistor open; E047-2 exhaust thermistor short. (NPE service manual (2020), p. 75)
Likely causes
- Exhaust thermistor bad or disconnected, poor PCB connection, or a heat exchanger problem. (NPE-2 service manual (2025), pp. 73, 92)
What you can check
- Call Navien Technical Support at 1-800-519-8794. The manual lists no owner fix for this code. (NPE-2 user’s manual, p. 17)
For a technician
- Check the thermistor connector. (NHB-H user’s manual, p. 24)
- Check the exhaust thermistor and connector; replace the thermistor if it is bad. (NPE-2 service manual (2025), p. 92)
- NPE-A/S: exhaust thermistor resistance between pins 9 and 10 of CON6 should be 2-300 kilohms. (NPE service manual (2020), p. 93)
-
The non-condensing NPN found a problem with its modulating gas valve (the valve that turns the flame up and down).Abnormal operation: Modulating gas valve
The non-condensing NPN found a problem with its modulating gas valve (the valve that turns the flame up and down). (NPN user’s manual, p. 22)
By model: NPN only.
Likely causes
- Modulating gas valve fault or wrong voltage from the PCB. (NPN service manual (2025), p. 78)
What you can check
- Call Navien Technical Support at 1-800-519-8794. The manual lists no owner fix for this code. (NPN user’s manual, p. 22)
For a technician
- Check the gas valve resistance and the voltage from the PCB. Valve bad: replace the gas control valve. PCB bad: replace the PCB. Both OK: reset. (NPN service manual (2025), pp. 78, 88)
-
The heater found a problem with its dual venturi, the part that mixes gas and air for the burner.Abnormal operation: dual venturi
The heater found a problem with its dual venturi, the part that mixes gas and air for the burner. (NPE-2 user’s manual, p. 17)
By model: Not in the NPN owner’s manual table.
Sub-codes
- E060-1 dual venturi limit switch ON fault; E060-2 Close OFF fault; E060-3 Open ON fault. (NPE service manual (2020), p. 75)
Likely causes
- Bad dual venturi or harness, or a bad controller; gas orifice obstruction. (NPE-2 service manual (2025), pp. 74, 93-94)
What you can check
- Call Navien Technical Support at 1-800-519-8794. The manual lists no owner fix for this code. (NPE-2 user’s manual, p. 17)
For a technician
- Check the dual venturi. (NCB700 installation manual, p. 136)
- Disconnect the dual venturi cables and test the wiring with a meter. (NPE-2 service manual (2025), p. 94)
- Turn power off at the main switch (not the front panel button), wait 10 seconds, power up, let Fan Auto Adjusting finish, then run Dual Venturi Test Mode at least twice and listen for clicks at ON and OFF. If E060 appears, replace the dual venturi. (NPE-2 service manual (2025), p. 94)
- Check the gas orifice for obstructions. (NPE-2 service manual (2025), p. 74)
- NPE-A/S: if the dual venturi test passes with no error, replace the APS. (NPE service manual (2020), p. 95)
-
The combustion fan is not running the way it should.Abnormal operation: fan motor
The combustion fan is not running the way it should. (NPE-2 user’s manual, p. 17)
By model: NPN says call Technical Support; the condensing units and combi-boilers say clean the intake air filter first.
Likely causes
- No fan power (Black+Red about DC 127-184 V), a loose white fan connector, a wet fan connector from a leak, a bad fan motor, or a bad PCB. (NPE-2 service manual (2025), pp. 95-96)
- NPN: blower will not turn, wrong fan voltage (Black+Red about DC 170 V), or a bad APS. (NPN service manual (2025), p. 90)
What you can check
- Clean the air intake filter. Navien’s owner’s manual has you turn the heater off, unplug it, remove the front cover and the one screw holding the filter, rinse it, let it dry and put it back. Navien says to do this every 3-4 months. (NPE-2 user’s manual, pp. 14, 17)
- NPN: call Navien Technical Support at 1-800-519-8794 (no owner fix listed). (NPN user’s manual, p. 22)
For a technician
- Check the fan and venting. (NHB-H user’s manual, p. 24)
- Run the fan in component test mode; check fan voltage; if RPM is low with good power, replace the fan motor. (NPE-2 service manual (2025), p. 95)
- If the fan connector is wet, power the unit off and dry the parts completely before running again. (NPE-2 service manual (2025), p. 95)
- Before unplugging or plugging the fan cable, unplug the unit and wait 10 seconds. Plugging fan cables in with power on can damage the fan drive or main PCB. (NPE-2 service manual (2025), p. 96)
- Use Fan Test Mode to read RPM and APS voltage (display H.320 = 3,200 RPM); replace the fan if RPM is low, then the PCB if needed. (NPE-2 service manual (2025), p. 96)
- NPN: turn the blower by hand; replace the fan motor if it will not turn. (NPN service manual (2025), p. 90)
-
Air or exhaust flow through the heater is blocked or restricted.Abnormal air pressure
Air or exhaust flow through the heater is blocked or restricted. A clogged air intake filter, a blocked vent, or (on NCB700) a blocked condensate drain can cause it. (NPE-2 user’s manual, p. 17)
By model: Water heaters and NCB-E call it 'Abnormal air pressure'; NCB-H, NCB700, NHB-H and NFB-H call it 'Exhaust Blockage'. NPN lists only the vent check (no air filter step). Only the NCB700 manual mentions the condensate drain for E110.
Sub-codes
- E110-1 exhaust blockage (checking the FAN); E110-2 exhaust blockage (using hot water); E110-3 exhaust blockage (using space heating). (NPE service manual (2020), p. 76)
- NPN: E110-1 abnormal air pressure. (NPN service manual (2025), p. 76)
Likely causes
- Air intake filter clogged by dust or lint: the heater stops and shows 'Error Code 110'. (NPE-2 user’s manual, p. 14; NPE user’s manual, p. 13; NCB-H user’s manual, p. 16)
- Blocked intake, exhaust or condensate drain pipe (ice, snow, wildlife and so on). (NPE-2 service manual (2025), p. 74)
- Condensate drain trouble blocks the exhaust: frozen condensate hose or siphon, kinked hose, or a blocked trap. (NPE-2 service manual (2025), p. 98)
- Clogged venturi (burner) hole, flue installed wrong or too close to things, rainwater collected in a badly installed intake/exhaust pipe, or a bad air pressure sensor (APS) or PCB. (NPE-2 service manual (2025), p. 97)
- Exhaust gas getting pulled back into the air intake causes bad combustion and E110. (NPE-2 service manual (2025), p. 98)
- Broken or clogged APS hose. (NPE-2 service manual (2025), p. 98)
- NPN: debris in the exhaust pipe, debris on the heat exchanger surface, condensate in the exhaust duct, or a bad APS. (NPN service manual (2025), pp. 78, 91)
What you can check
- Look outside at the exhaust (vent) pipe and make sure nothing is blocking it. (NPE-2 user’s manual, p. 17)
- Clean the air intake filter. Navien’s owner’s manual has you turn the heater off, unplug it, remove the front cover and the one screw holding the filter, rinse it, let it dry and put it back. Navien says to do this every 3-4 months. (NPE-2 user’s manual, pp. 14, 17)
- NCB700: check that the condensate drain outlet is not blocked and is draining properly. (NCB700 installation manual, p. 136)
- Look at the intake and exhaust pipe ends outside and clear snow, ice, nests or debris. Check the condensate drain hose outside the heater is not kinked or frozen. (NPE-2 service manual (2025), pp. 74, 98)
For a technician
- Check the exhaust venting. (NHB-H user’s manual, p. 24)
- If E110 comes and goes at ignition or during firing, compare the standard fan RPM with the actual RPM at min and max fire (PCB DIP 1-1 and 1-2). Higher than normal points to a vent blockage, a blocked condensate drain, or a broken/clogged APS hose. (NPE-2 service manual (2025), p. 98)
- Take off the bottom of the condensate trap and make sure it is not blocked. (NPE-2 service manual (2025), p. 98)
- Check the venturi (burner) hole for clogging and the flue for damage, obstruction and collected rainwater. (NPE-2 service manual (2025), pp. 97-98)
- Check the vent termination is at least 12 in. (305 mm) above the highest expected snow line, or what local code requires, whichever is greater; check intake-to-exhaust spacing so exhaust is not pulled back in. (NPE-2 service manual (2025), p. 98)
- Check the APS: RED-BLACK DC 5 V, WHITE-BLACK DC 0.3-4.5 V; also check the condensate trap and drain piping. (NPE-2 service manual (2025), p. 64)
- Replace an old PCB with the latest version. (NPE-2 service manual (2025), p. 98)
- NPN: check the APS, fan RPM, exhaust flue, heat exchanger surface for foreign matter, and condensate in the exhaust duct; clear foreign matter around the exhaust, then reset. (NPN service manual (2025), p. 91)
-
NPN: the air-volume control circuit reads open, shorted, a default value, or does not answer.Abnormal operation : Air volume Open/Short/Default value/No answer
NPN: the air-volume control circuit reads open, shorted, a default value, or does not answer. (NPN user’s manual, p. 22)
By model: NPN only.
Sub-codes
- E127-1 air volume open (level 3, Manual RESET); E127-2 short (level 2, Auto RESET); E127-3 default value (level 2, Auto RESET); E127-5 no answer (level 3, Manual RESET). (NPN service manual (2025), p. 76)
Likely causes
- APS (air pressure sensor) disconnected or shorted, pressure sensed while the fan is stopped, or the APS not working. (NPN service manual (2025), p. 92)
What you can check
- Call Navien Technical Support at 1-800-519-8794. The manual lists no owner fix for this code. (NPN user’s manual, p. 22)
For a technician
- Check the APS connection, harness, hose and voltage, and the PCB voltage; check whether the fan runs while the heater is idle. (NPN service manual (2025), pp. 78, 92)
- Reconnect the wiring and harness; replace the fan motor or the APS as needed; replace the PCB if it continues. (NPN service manual (2025), p. 92)
-
NPN: the heater cannot control the amount of combustion air correctly.Abnormal operation : Air volume control
NPN: the heater cannot control the amount of combustion air correctly. (NPN user’s manual, p. 22)
By model: NPN only.
Likely causes
- The APS could not reach the ignition air level within 25 seconds more than 10 times: bent APS hose, damaged APS (-) fan hose connection, or fan bellmouth capacity. (NPN service manual (2025), p. 92)
What you can check
- Call Navien Technical Support at 1-800-519-8794. The manual lists no owner fix for this code. (NPN user’s manual, p. 22)
For a technician
- Straighten the APS hose; switch the (+) and (-) hoses if reversed; replace the fan, then the APS, then the PCB if needed. (NPN service manual (2025), p. 92)
-
NPN: the antifreeze (freeze-protection) heater circuit reads open or shorted.Antifreeze heater Open/Short
NPN: the antifreeze (freeze-protection) heater circuit reads open or shorted. (NPN user’s manual, p. 22)
By model: NPN only.
What you can check
- Call Navien Technical Support at 1-800-519-8794. The manual lists no owner fix for this code. (NPN user’s manual, p. 22)
- Freeze guidance from the same manual: keep the heater plugged in; if power or gas will be off for a long time, drain the heater. (NPN user’s manual, p. 20)
-
The temperature sensor on the hot water outlet reads open or shorted.Hot water outlet: thermistor open or short circuit
The temperature sensor on the hot water outlet reads open or shorted. The heater cannot read the outgoing water temperature. (NPE-2 user’s manual, p. 17)
By model: Same meaning everywhere. The NR-21DU remote manual says 'thermostat' where the owner’s manuals say 'thermistor'.
Sub-codes
- E407-1 open; E407-2 short. (NPE service manual (2020), p. 76)
- NPN: E407-1 open, E407-2 short; level 2, Auto RESET. (NPN service manual (2025), p. 76)
Likely causes
- Wet sensor connector (from a leak), loose connector, or a failed sensor (bad at 30 kilohms or higher); bad PCB. (NPE-2 service manual (2025), p. 99)
What you can check
- Call Navien Technical Support at 1-800-519-8794. The manual lists no owner fix for this code. (NPE-2 user’s manual, p. 17)
For a technician
- Check the connector is dry and seated; measure sensor resistance against the table (e.g. 60-70 °F = 9.4-12.8 kilohms); replace the sensor, then the controller. (NPE-2 service manual (2025), pp. 60, 99)
- NPN: replace the thermistor if the wire is broken, repair shorted wiring, reconnect; replace the PCB if it continues. (NPN service manual (2025), p. 93)
-
The temperature sensor on the cold water inlet reads open or shorted.Cold water inlet1: thermistor open or short circuit
The temperature sensor on the cold water inlet reads open or shorted. (NPE-2 user’s manual, p. 17)
By model: Same meaning everywhere.
Sub-codes
- E421-1 open; E421-2 short. (NPE service manual (2020), p. 76)
- NPN ('direct water thermistor'): E421-1 open, E421-2 short; level 2, Auto RESET. (NPN service manual (2025), p. 76)
Likely causes
- Wet or loose connector, or a failed sensor (bad at 30 kilohms or higher); bad PCB. (NPE-2 service manual (2025), p. 100)
What you can check
- Call Navien Technical Support at 1-800-519-8794. The manual lists no owner fix for this code. (NPE-2 user’s manual, p. 17)
For a technician
- Check the connector; measure the sensor; replace the sensor, then the PCB. (NPE-2 service manual (2025), p. 100)
- NPE-A/S: resistance between pins 1 and 2 of CON7 should be 0.437-176 kilohms; unplug the connector from the PCB before measuring; check [C] in DIAGNOSTIC mode. (NPE service manual (2020), pp. 76, 100)
-
Condensing NPE heaters: the second cold water inlet temperature sensor reads open or shorted.Cold water inlet2: thermistor open or short circuit
Condensing NPE heaters: the second cold water inlet temperature sensor reads open or shorted. (NPE-2 user’s manual, p. 17)
By model: NPE (condensing) only. Not in the NPN or combi-boiler tables.
Sub-codes
- E432-1 open; E432-2 short. (NPE service manual (2020), p. 76)
Likely causes
- Open sensor or loose connector, or a bad PCB. (NPE-2 service manual (2025), p. 101)
What you can check
- Call Navien Technical Support at 1-800-519-8794. The manual lists no owner fix for this code. (NPE-2 user’s manual, p. 17)
For a technician
- Check the secondary heat exchanger inlet thermistor and connector; replace the thermistor. (NPE-2 service manual (2025), p. 101)
- NPE-A/S: resistance between pins 5 and 6 of CON7 should be 0.437-176 kilohms (connector unplugged). (NPE service manual (2020), p. 101)
-
The valve that controls water flow through the heater is not working right.Abnormal operation: water adjustment valve
The valve that controls water flow through the heater is not working right. (NPE-2 user’s manual, p. 17)
By model: Not in the NCB-E table.
Sub-codes
- E434-1 valve open fault; E434-2 valve close fault. (NPE service manual (2020), p. 76)
- NPN: E434-1 open, E434-2 close; level 1 alarm. (NPN service manual (2025), p. 76)
Likely causes
- Bad water adjustment valve or feedback sensor, or a bad PCB (motor keeps running or the valve keeps opening and closing). (NPE-2 service manual (2025), pp. 101-102)
What you can check
- Call Navien Technical Support at 1-800-519-8794. The manual lists no owner fix for this code. (NPE-2 user’s manual, p. 17)
- Clean the cold water inlet filter (owner's manual procedure; drain the heater first). (NPE-2 service manual (2025), p. 67)
For a technician
- Run the water adjustment valve in Component Test mode; check the connector and motor resistance (CON8); valve feed RED-BLACK DC 12 V. (NPE-2 service manual (2025), pp. 67, 102)
- In a cascade, unplug the cascade cable first and test the unit alone. (NPE-2 service manual (2025), p. 102)
- Emergency only: power off, shut water, drain, take the valve motor off, turn the valve disk counterclockwise to fully open, unplug the valve's power, then run on hot water until the part is replaced. (NPE-2 service manual (2025), p. 103)
- NPN: reset power; check valve voltage and connector; replace the valve or PCB. (NPN service manual (2025), p. 95)
-
The heater’s recirculation pump is not working right.Abnormal operation: circulation pump
The heater’s recirculation pump is not working right. On NPE-A2/S2 the owner’s manual ties it to systems with an air handler (AHU) installed. (NPE-2 user’s manual, p. 17)
By model: Water heater code only (not on combi-boiler lists). The NPE-A2/S2 owner’s manual limits it to AHU (air handler / H2Air) installs; the NR-21DU remote, NPE-A/S and NPN manuals describe external and internal recirculation checks.
Likely causes
- Bad flow sensor, bad pump, air locked in the pump, debris in the water filter, or a bad PCB. (NPE-2 service manual (2025), p. 104)
- No cold water reaching the heater. (NPE-2 service manual (2025), p. 104)
- With an air handler: no power to the AHU circulation pump, or the recirculation pump filter is clogged. (NPE-2 service manual (2025), p. 74)
- Return filter blocked or the check valve stuck. (NPE-2 service manual (2025), p. 105)
- NPE-A/S: also check the cold water main line. (NPE service manual (2020), p. 76)
What you can check
- External recirculation: make sure all water supply and return line valves are open. (NPE user’s manual, p. 16; NR-21DU remote manual, p. 31; NPN user’s manual, p. 22)
- Internal recirculation (NPE-A): check the direction of the 2-way valve. (NPE user’s manual, p. 16)
- NPE-A2/S2 with an air handler: check if the circulation pump is operating properly. (NPE-2 user’s manual, p. 17)
- Make sure cold water is reaching the heater (the cold water supply valve is open). (NPE-2 service manual (2025), p. 104)
- Clean the recirculation inlet filter (A2 models). The owner's manual shows how; the heater must be drained first (User's Information Manual p. 13). (NPE-2 service manual (2025), pp. 74, 105)
For a technician
- Use Component Test mode to run the pump and the flow sensor. (NPE-2 service manual (2025), p. 104)
- Check the pump power: AC 102-132 V at the pump (component page: YELLOW-WHITE wires, ON AC 96-138 V); check the pump connector and wiring, and check the pump resistance. (NPE-2 service manual (2025), pp. 72, 105)
- Bleed air out of the pump and system. (NPE-2 service manual (2025), p. 105)
- Check the front panel flow reading: 0.0 gal/min while the pump runs or a hot tap is open means the flow sensor is bad. (NPE-2 service manual (2025), p. 105)
- If everything above checks out, replace the PCB. (NPE-2 service manual (2025), p. 105)
- NPE-A/S: set the heater to Internal Recirculation mode and check the flow rate. (NPE service manual (2020), p. 76)
- NPN: check that the external circulation pump is running. (NPN service manual (2025), p. 79)
-
The water flow sensor is not reading right, so the heater cannot tell how much hot water is being used.Abnormal operation: flow sensor
The water flow sensor is not reading right, so the heater cannot tell how much hot water is being used. (NPE-2 user’s manual, p. 17)
By model: NCB-H/NCB700 word it as 'No Dom. Water Flow Detected'. Related: Navien’s NPE-A2 FAQ says that when there is NO error code but no hot water, the flow sensor not spinning properly is the most likely cause and recommends the installer or a Navien Service Specialist (FAQ, not code-specific).
Likely causes
- No cold water flow: frozen line, locked or closed valve, clogged cold water filter, or water adjustment valve not opening. (NPE-2 service manual (2025), pp. 106-107)
- Bad or scaled flow sensor (front panel shows 0.0 flow with a hot tap open), or a bad PCB (no DC 12 V to the sensor). (NPE-2 service manual (2025), pp. 107, 118)
What you can check
- Call Navien Technical Support at 1-800-519-8794. The manual lists no owner fix for this code. (NPE-2 user’s manual, p. 17)
- NCB-E combi-boiler: reset the boiler from the front panel. (NCB-E user’s manual, p. 22)
- Make sure the cold water supply valve is open and the cold line is not frozen. (NPE-2 service manual (2025), pp. 106-107)
- Clean the cold water inlet filter (owner's manual procedure). (NPE-2 service manual (2025), p. 107)
For a technician
- Disable cascade, open a faucet, confirm flow; check the flow sensor connector (CON6) and DC 12 V supply (Black+Red). (NPE-2 service manual (2025), pp. 106-107)
- Drain, remove the flow sensor (4 screws and clips), blow through it from the inlet side and check the impeller spins freely; clean out debris or replace the sensor. (NPE-2 service manual (2025), pp. 107-108)
-
A second hot-water temperature sensor reads open or shorted.Hot water inlet2: thermistor open or short circuit
A second hot-water temperature sensor reads open or shorted. (NPE-2 user’s manual, p. 17)
By model: Water heater manuals call it 'Hot water inlet2'; NCB-H/NCB700 call it 'Dom. Hot Water Outlet2 Sensor'. Not on the NCB-E list.
Sub-codes
- E441-1 open; E441-2 short. (NPE service manual (2020), p. 76)
- NPN ('heat exchanger outlet thermistor'): E441-1 open, E441-2 short; level 2, Auto RESET. (NPN service manual (2025), p. 76)
Likely causes
- Heat exchanger outlet thermistor or its connector. (NPE-2 service manual (2025), p. 109)
- NPN: open or shorted heat exchanger outlet thermistor wiring. (NPN service manual (2025), p. 96)
What you can check
- Call Navien Technical Support at 1-800-519-8794. The manual lists no owner fix for this code. (NPE-2 user’s manual, p. 17)
For a technician
- Check the thermistor and resistance; replace the thermistor; check the connector. (NPE-2 service manual (2025), pp. 74, 109)
- NPE-A/S: resistance between pins 3 and 4 of CON7 should be 0.437-176 kilohms (connector unplugged). (NPE service manual (2020), p. 110)
-
The bypass mixing valve (which blends water to hold a steady outlet temperature) is not working right.Abnormal operation: Bypass mixing valve
The bypass mixing valve (which blends water to hold a steady outlet temperature) is not working right. This is not a scale or descale reminder code. (NPE-2 user’s manual, p. 17)
By model: Not in the NR-21DU remote list or NCB-E list. Navien’s scale/descale reminder is E760 (shown as 'A.760' on the NR-21DU remote), not E445.
Sub-codes
- E445-1 mixing valve open fault; E445-2 close fault. (NPE service manual (2020), p. 76)
- NPN: E445-1 open, E445-2 close; level 1 alarm. (NPN service manual (2025), p. 76)
Likely causes
- Bad mixing valve or feedback sensor, or a bad PCB. (NPE-2 service manual (2025), pp. 109-110)
- NPN: no feedback for more than 10 seconds with the mixing valve fully open. (NPN service manual (2025), p. 97)
What you can check
- Call Navien Technical Support at 1-800-519-8794. The manual lists no owner fix for this code. (NPE-2 user’s manual, p. 17)
For a technician
- Run the mixing valve in Component Test mode; check its connector and motor resistance. (NPE-2 service manual (2025), p. 110)
- Emergency only: power off, shut water, drain, take the valve motor off, turn the disk counterclockwise to open, unplug the valve, then run until replaced. (NPE-2 service manual (2025), p. 111)
- NPN: reset power; check mixing valve voltage and connector; replace the valve or PCB. (NPN service manual (2025), p. 97)
-
The main control board (PCB) found a problem with itself.Abnormal operation: PCB
The main control board (PCB) found a problem with itself. Navien’s first owner step is to check the electrical ground. (NPE-2 user’s manual, p. 17)
By model: The owner’s manuals say PCB (circuit board). The NR-21DU remote manual calls E515 'Abnormal operation: controller' and says check the front panel settings. Some websites call E515 a cascade or freeze-valve fault; no Navien document read says that.
Sub-codes
- NPE-A2/S2 flow chart: sub 1, 2 or 10 = power reset, then replace the main PCB; sub 3 or 4 = check wiring between gas valve and main PCB; sub 9 = check fan voltage; sub 11 or 12 = check wiring between dual venturi and main controller, and the dual venturi. (NPE-2 service manual (2025), p. 112)
- NPE-A/S: sub 1-7 PCB-igniter communication (check PCB); 8 PCB-igniter (check PCB connection and igniter); 9 PCB-fan; 10 PCB monitoring device (check PCB connection and dual venturi); 11-12 PCB-dual venturi. (NPE service manual (2020), p. 76)
- NPN: sub 1 WD SSR1, 2 WD SSR2, 3 gas valve feedback, 5/6/7/15 manifold valve 1/2/3/4 feedback, 10 monitoring device; all level 3, Manual RESET. (NPN service manual (2025), p. 77)
Likely causes
- Bad PCB, wrong supply voltage (outlet should read AC 102-132 V), loose wiring, grounding noise, or a gas valve not connected to the harness. (NPE-2 service manual (2025), p. 112)
- NPN: sub 3 gas valve resistance fault; sub 5, 6, 7, 15 manifold solenoid faults; sub 1, 2, 10 PCB fault. (NPN service manual (2025), p. 98)
What you can check
- Make sure the heater’s electrical cord is properly grounded (Navien’s owner’s manual step). (NPE-2 user’s manual, p. 17)
- If the code came up on the NR-21DU remote: check the front panel settings. (NR-21DU remote manual, p. 32)
- Combi-boilers: reset the boiler from the front panel. (NCB-H user’s manual, p. 26)
- Turn the power off and back on (unplug and plug back in) once. (NPE-2 service manual (2025), p. 112)
For a technician
- Check the PCB connections. (NHB-H user’s manual, p. 24)
- Measure outlet voltage (AC 102-132 V); check wire connections; disconnect ground at the terminal inside to test for grounding noise; check the gas valve harness. (NPE-2 service manual (2025), p. 112)
- Follow the sub code flow chart, then replace the PCB if it continues. (NPE-2 service manual (2025), p. 112)
- NPN: sub 1, 2, 10: reset power, then replace the PCB. Sub 3: reconnect the gas valve connector and measure its resistance. Sub 5, 6, 7, 15: reconnect the manifold solenoid connector and measure its resistance. Replace the part that is out of range. (NPN service manual (2025), p. 98)
-
A DIP switch (small setup switch) is set wrong for this model.Abnormal operation: DIP switch setting
A DIP switch (small setup switch) is set wrong for this model. (NPE-2 user’s manual, p. 17)
By model: Same meaning everywhere. Only the NR-21DU remote manual and the boiler manuals point at the DIP switches directly; the owner’s manuals say call Technical Support.
Likely causes
- DIP switches on the front panel or PCB set wrong. (NPE-2 service manual (2025), pp. 74, 113)
What you can check
- Call Navien Technical Support at 1-800-519-8794. The manual lists no owner fix for this code. (NPE-2 user’s manual, p. 17)
For a technician
- Check the circuit board DIP switch settings against the Installation Manual. (NR-21DU remote manual, p. 32)
- NPE-A2/S2: the two circuit-board DIP switches set the model; they are set at the factory and should not be changed. (NPE-2 installation manual, p. 61)
- Set the front panel and PCB DIP switches correctly, then reset; replace the PCB if it continues. (NPE-2 service manual (2025), p. 113)
- NPN: same, check PCB DIP settings and reset. (NPN service manual (2025), p. 99)
-
A button on the front panel is stuck or not working.Abnormal operation: front panel key
A button on the front panel is stuck or not working. (NPE-2 user’s manual, p. 17)
Sub-codes
- E593-1 abnormal panel key. (NPE service manual (2020), p. 77)
Likely causes
- Water on the front panel keys, or a bad front panel. (NPE-2 service manual (2025), p. 74)
What you can check
- Call Navien Technical Support at 1-800-519-8794. The manual lists no owner fix for this code. (NPE-2 user’s manual, p. 17)
- Check for water on the front panel keys and wipe the panel dry, then reset. (NPE-2 service manual (2025), pp. 74, 113)
For a technician
- Replace the front panel if the keys do not work. (NPE-2 service manual (2025), p. 113)
-
The control board’s memory chip (EEPROM) has a problem.Abnormal operation: EEPROM
The control board’s memory chip (EEPROM) has a problem. (NPE-2 user’s manual, p. 17)
By model: Not in the NPE-A/S owner’s manual or the NR-21DU remote list.
Likely causes
- EEPROM fault on the PCB. (NPE-2 service manual (2025), p. 74)
What you can check
- Call Navien Technical Support at 1-800-519-8794. The manual lists no owner fix for this code. (NPE-2 user’s manual, p. 17)
For a technician
- Check the PCB. (NHB-H user’s manual, p. 24)
- Replace the PCB. (NPE-2 service manual (2025), p. 74)
-
The control board found a problem with its input or memory.Abnormal operation: input and memory
The control board found a problem with its input or memory. (NPE-2 user’s manual, p. 17)
Sub-codes
- NPE-A/S: 0 high limit switch input; 1 exhaust sensor input; 2 flame rod input; 3-14 PCB memory; 15 pressure sensor input too low; 16 too high. (NPE service manual (2020), p. 77)
- NPN: sub 1-17, level 3, Manual RESET. (NPN service manual (2025), p. 77)
Likely causes
- PCB input or memory fault. (NPE-2 service manual (2025), p. 114)
What you can check
- Call Navien Technical Support at 1-800-519-8794. The manual lists no owner fix for this code. (NPE-2 user’s manual, p. 17)
- Turn the power off and back on (or unplug and plug back in) once. (NPE-2 service manual (2025), p. 114)
For a technician
- Check the PCB connections. (NHB-H user’s manual, p. 24)
- If E615 is still shown after a power reset, replace the main PCB. (NPE-2 service manual (2025), p. 114)
- NPE-A/S: check exhaust sensor, flame rod or pressure sensor wiring by sub code. (NPE service manual (2020), p. 77)
-
In a cascade (several heaters linked together), the units lost communication with each other.Abnormal operation: cascade communication
In a cascade (several heaters linked together), the units lost communication with each other. (NPE-2 user’s manual, p. 18)
By model: Only shows on linked (cascade) systems. In a cascade the NR-21DU remote shows status, error code and Cascade ID in turn (remote p. 26).
Likely causes
- Ready-Link cascade cable not installed on all units, wrong cascade settings, or PCB versions that do not match. (NPE-2 service manual (2025), pp. 74, 114)
What you can check
- Call Navien Technical Support at 1-800-519-8794. The manual lists no owner fix for this code. (NPE-2 user’s manual, p. 18)
For a technician
- Check the cascade cable. (NHB-H user’s manual, p. 24)
- Check and reconnect the Ready-Link cascade cable on every unit, check cascade settings and PCB version compatibility, then reset. (NPE-2 service manual (2025), pp. 74, 114)
- NPN: check cascade wiring and the PCB. (NPN service manual (2025), p. 79)
-
The outdoor temperature sensor is missing or reading out of range.Abnormal operation: outdoor temperature sensor
The outdoor temperature sensor is missing or reading out of range. It only matters when outdoor reset (weather-based heating control) is turned on. (NPE-2 user’s manual, p. 18)
By model: On water heaters it only applies with an air handler/H2Air space-heating setup. Not on the NR-21DU remote list.
Sub-codes
- E740-1 outdoor sensor open; E740-2 short. (NPE service manual (2020), p. 77)
- NPN: E740-1 AHU outdoor thermistor open, E740-2 short; level 1 alarm. (NPN service manual (2025), p. 77)
Likely causes
- NPE-A2/S2 with the H2Air accessory: outdoor reset is on (H2Air DIP switch #1 OFF) and the outdoor sensor is not connected or reads outside the normal range; '740' shows and the system runs as if outdoor reset were off. (NPE-2 installation manual, p. 104)
- Wet or bad outdoor sensor connector or sensor, or a parameter setting. (NPE-2 service manual (2025), p. 115)
What you can check
- Call Navien Technical Support at 1-800-519-8794. The manual lists no owner fix for this code. (NPE-2 user’s manual, p. 18)
For a technician
- Make sure the outdoor reset curve is set up correctly. (NCB-H user’s manual, p. 26)
- Check the outdoor temperature sensor wiring connection. (NCB-H user’s manual, p. 26)
- Check the outdoor sensor connector and resistance and the parameter setting; replace the sensor, then the controller. (NPE-2 service manual (2025), p. 115)
-
A maintenance reminder: the heater is due to have its heat exchanger flushed (descaled) or other routine service.Flushing/service alarm
A maintenance reminder: the heater is due to have its heat exchanger flushed (descaled) or other routine service. It is an alarm, not a breakdown. (NPE-2 user’s manual, p. 18)
By model: This is Navien’s scale/descale reminder. NPN has a 'Limescale Detection Alarm' DIP switch (#8, 12-month interval) in its Installation Manual p. 49; that page does not say which code it shows. Not on combi-boiler lists.
Likely causes
- Flushing interval reached. (NPE-2 service manual (2025), p. 115)
What you can check
- Contact your installer to do routine service. (NPE-2 user’s manual, p. 18)
- On the NR-21DU remote, the scale alarm shows as 'A.760'. To turn the alarm off, press and hold OK for 2 seconds; 'RST' shows for 3 seconds. Turning the alarm off does not clean the heater; the owner’s manual says to have the installer do routine service. (NR-21DU remote manual, p. 27)
- To silence the alarm on the NPE-A2/S2 front panel, press and hold Back for more than 2 seconds ('Alarm Reset'). This only clears the reminder; the heater still needs flushing. (NPE-2 service manual (2025), p. 49)
For a technician
- Flush (descale) the heat exchanger. (NPE-2 user’s manual, pp. 12-13)
- NPE-A2/S2: set or change the reminder interval at Installer Menu > Parameter Settings > 13. Descaling Reminder (No Alarm, 6, 12 or 24 months; default No Alarm). (NPE-2 installation manual, p. 100)
- Flush the heat exchanger, then reset the timer from the front panel. (NPE-2 service manual (2025), pp. 75, 115)
-
The heater’s vent detector does not see the exhaust pipe pushed all the way into the vent collar, so the heater will not run.Vent pipe not properly inserted
The heater’s vent detector does not see the exhaust pipe pushed all the way into the vent collar, so the heater will not run. A loose vent can leak carbon monoxide. (NPE-2 user’s manual, p. 18)
By model: Insertion depth differs: 2-3/4 in. (70 mm) on NPE-A2/S2 and NHB-H/NFB-H; 1.3 in. (34 mm) on NPN and NHW700. Not in the NPE-A/S (older) or NCB-E tables. The VID is not a CO detector and may not catch a pipe that separates later (NPE-A2/S2 Installation Manual p. 45).
Likely causes
- Vent pipe not inserted deep enough into the exhaust collar, so it does not press the Vent Installation Detector (VID) switch. (NPE-2 installation manual, p. 44)
- Wrong size vent pipe: 'ALWAYS only use the correctly sized vent pipe materials or an error code E762 can appear'. (NPE-2 installation manual, p. 45)
- NPN: vent pipe not inserted 1.3 in (34 mm) into the collar, or wrong-size or damaged pipe. (NPN installation manual, p. 38)
- Vent pipe not installed right, vent switch not working, or a damaged vent switch connector. (NPE-2 service manual (2025), p. 75)
What you can check
- Call Navien Technical Support at 1-800-519-8794. The manual lists no owner fix for this code. (NPE-2 user’s manual, p. 18)
For a technician
- NPE-A2/S2: use correctly sized vent pipe (the VID section names 2.0-in. pipe) and insert it at least 2-3/4 in. (70 mm) into the exhaust collar; start the vent run with straight pipe, never a street elbow at the collar. (NPE-2 installation manual, pp. 44-45)
- NPN: insert the vent pipe 1.3 in. (34 mm) into the collar; inspect the inserted end for damage and replace damaged pipe. (NPN installation manual, p. 38)
- NHW700: the vent drawing shows a 1.3 in. (34 mm) insertion depth; use only correctly sized vent pipe. (NHW700 installation manual, p. 46)
- After venting work, test the exhaust vent for leaks with a bubble test. (NPE-2 installation manual, p. 44)
- Check the vent pipe installation, the vent switch operation, and the switch connector. (NPE-2 service manual (2025), p. 75)
- NPN: check the flue connection and the flue dislocation switch and wiring. (NPN service manual (2025), p. 99)
-
The heater thinks the gas it is burning does not match the gas type it was set up for (natural gas vs.Using the wrong gas
The heater thinks the gas it is burning does not match the gas type it was set up for (natural gas vs. propane). Wrong gas causes bad combustion. (NPE-2 user’s manual, p. 18)
By model: Names differ: 'Using the wrong gas' (NPE-A2/S2 owner’s manual), 'Abnormal operation: gas connection' (NPN), 'Improper Gas Type Detected' (NCB-H/NCB700); installation manuals call it 'Improper Gas Type Detection Warning'. Not in the NPE-A/S or NCB-E tables.
Likely causes
- The unit detects a difference between the gas type set during installation and the gas type connected. (NPE-2 installation manual, p. 19)
- It can also trip with the correct gas and correct setting because of measuring tolerances; detection depends on gas flow rate and exhaust temperature. (NPE-2 installation manual, p. 19)
- Gas supply problem or gas control valve fault. (NPE-2 service manual (2025), p. 75)
- NPN: wrong fuel or DIP settings; manifold not replaced during LP conversion. (NPN service manual (2025), pp. 67, 79)
What you can check
- Call Navien Technical Support at 1-800-519-8794. The manual lists no owner fix for this code. (NPE-2 user’s manual, p. 18)
- Make sure the main gas supply valve to the heater is fully open. (NPE-2 service manual (2025), p. 75)
For a technician
- Check that front panel DIP switch #1 matches the gas supplied (OFF = natural gas, ON = propane) and that the rating plate matches the gas type and pressure. (NPE-2 installation manual, pp. 19, 61)
- If E773 keeps coming back with the DIP switch matching the connected gas, contact Navien Technical Support. (NPE-2 installation manual, p. 19)
- Check gas supply and the gas control valve. (NPE-2 service manual (2025), p. 75)
- NPN: check the fuel, DIP switches, manifold nozzle size, gas leaks and flame pattern. (NPN service manual (2025), pp. 67, 79)
-
The main control board and the front panel display stopped talking to each other.Abnormal operation: main panel communication
The main control board and the front panel display stopped talking to each other. (NPE-2 user’s manual, p. 18)
Likely causes
- Front panel wiring to the PCB, the panel, or the PCB. (NPE-2 service manual (2025), pp. 75, 116)
What you can check
- Call Navien Technical Support at 1-800-519-8794. The manual lists no owner fix for this code. (NPE-2 user’s manual, p. 18)
For a technician
- Check the panel connections. (NHB-H user’s manual, p. 24)
- Reconnect the panel to the PCB; reset; replace the PCB if it continues. (NPE-2 service manual (2025), p. 116)
-
Water heaters with an air handler: the flow switch or flow sensor is not working right.Abnormal operation: flow switch/sensor
Water heaters with an air handler: the flow switch or flow sensor is not working right. (NPE-2 user’s manual, p. 18)
By model: The NPE-A2/S2 manual ties it to installs with an air handler (AHU). The NPE-A/S and NPN tables do not add that limit. Not on the NR-21DU remote list.
Likely causes
- Flow switch stuck, installed backwards, or wiring fault. (NPE-2 service manual (2025), p. 116)
What you can check
- Call Navien Technical Support at 1-800-519-8794. The manual lists no owner fix for this code. (NPE-2 user’s manual, p. 18)
For a technician
- Check flow switch state, direction, terminal resistance and water flow; replace the controller if needed. (NPE-2 service manual (2025), p. 116)
-
The front panel is not connected right or is the wrong panel for this unit.Abnormal operation: panel connection
The front panel is not connected right or is the wrong panel for this unit. (NPN user’s manual, p. 23)
By model: NPN wording is 'panel connection'; NCB-H/NCB700/NHB-H/NFB-H say 'Improper Front Panel'. Not on NPE lists.
What you can check
- Call Navien Technical Support at 1-800-519-8794. The manual lists no owner fix for this code. (NPN user’s manual, p. 23)
For a technician
- Check for the correct front panel version. (NHB-H user’s manual, p. 24)
-
The gas type set by the DIP switch does not match the gas type set in the panel.Abnormal operation: Discrepancy with the gas type on the panel DIP S/W setting and the panel
The gas type set by the DIP switch does not match the gas type set in the panel. The two settings disagree. (NPE-2 user’s manual, p. 18)
By model: NPE-A2/S2 compares the front panel DIP switch with the panel; NCB-H/NCB700 point to the PCB DIP switch. Not in NPE-A/S, NPN or NCB-E tables.
Likely causes
- Gas type setting on the panel DIP switch and the panel do not match. (NPE-2 user’s manual, p. 18)
What you can check
- Call your installer or Navien Technical Support at 1-800-519-8794; the fix is a gas-type setting. (NPE-2 user’s manual, p. 18)
For a technician
- Check the gas actually supplied, then match the gas-type setting on the panel DIP switch and the panel. (NPE-2 user’s manual, p. 18)
- NPE-A2/S2 front panel DIP switch #1 sets gas type: OFF = natural gas, ON = propane. It is factory set and should only change if the unit was converted for propane. (NPE-2 installation manual, p. 61)
Combi-boilers and boilers only
These codes aren’t in any Navien tankless water heater manual. They show on NCB combi-boilers, which heat the house and make the hot water, and on NHB and NFB boilers.
-
The boiler’s heat exchanger got too hot.Heat Exchanger Overheat
The boiler’s heat exchanger got too hot. This code is listed only for Navien combi-boilers and boilers, not for Navien tankless water heaters. (NCB-H user’s manual, p. 25)
By model: Boiler/combi-boiler code only. Not in any NPE, NPN or NHW water heater code table. Some websites list E001 as 'ignition failure' on NPE water heaters; Navien’s NPE manuals use E003 for ignition failure and do not list E001.
What you can check
- Reset the boiler from the front panel (Back button). (NCB-H user’s manual, pp. 13, 25)
- Reset the boiler from the front panel (NCB700). (NCB700 installation manual, p. 136)
For a technician
- Check for proper heating-system flow. (NHB-H user’s manual, p. 24)
-
The boiler found a problem with its gas control valve.Abnormal Gas Control Valve
The boiler found a problem with its gas control valve. Listed only for the NCB700 combi-boiler. (NCB700 installation manual, p. 136)
By model: NCB700 only. Not in any Navien water heater table read.
Likely causes
- Gas control valve not working: no DC 22-24 V from the PCB, coil short or open, or a bad solenoid valve. (NPE-2 service manual (2025), pp. 88-89)
What you can check
- Call Navien Technical Support at 1-800-519-8794. The manual lists no owner fix for this code. (NCB700 installation manual, p. 136)
For a technician
- Check the gas valve gets DC 22-24 V (white-yellow, white-red). No voltage: replace the PCB. Voltage OK: check for an open coil. (NPE-2 service manual (2025), pp. 88-89)
-
NCB700 combi-boiler: a fault with the fan blower.Abnormal Fan Motor Blower
NCB700 combi-boiler: a fault with the fan blower. (NCB700 installation manual, p. 136)
By model: NCB700 only.
Likely causes
- Fan motor blower fault. (NPE-2 service manual (2025), p. 98)
What you can check
- Call Navien Technical Support at 1-800-519-8794. The manual lists no owner fix for this code. (NCB700 installation manual, p. 136)
For a technician
- Check the fan motor blower; the detail page says replace it. (NPE-2 service manual (2025), pp. 74, 98)
-
Combi-boilers and boilers only: the sensor on the heating supply (hot water going out to the home’s heating loop) reads open or shorted.Heating supply thermistor open or short circuit
Combi-boilers and boilers only: the sensor on the heating supply (hot water going out to the home’s heating loop) reads open or shorted. (NCB-E user’s manual, p. 22)
By model: Not a water heater code. Navien tankless water heaters (NPE, NPN) do not list E205; it belongs to the space-heating side of combi-boilers and boilers.
What you can check
- Call Navien Technical Support at 1-800-519-8794. The manual lists no owner fix for this code. (NCB-E user’s manual, p. 22)
For a technician
- Check heating flow and the thermistor connector. (NHB-H user’s manual, p. 24)
-
Combi-boilers and boilers only: the sensor on the heating return (water coming back from the heating loop) reads open or shorted.Heating return thermistor open or short circuit
Combi-boilers and boilers only: the sensor on the heating return (water coming back from the heating loop) reads open or shorted. (NCB-E user’s manual, p. 22)
By model: Combi-boiler/boiler code only.
What you can check
- Call Navien Technical Support at 1-800-519-8794. The manual lists no owner fix for this code. (NCB-E user’s manual, p. 22)
For a technician
- Check the thermistor connector. (NHB-H user’s manual, p. 24)
-
Combi-boilers and boilers: the external heating supply temperature sensor is not detected.Ext. Supply Sensor Not Detected
Combi-boilers and boilers: the external heating supply temperature sensor is not detected. (NCB-H user’s manual, p. 25)
By model: Combi-boiler/boiler code only.
What you can check
- Call Navien Technical Support at 1-800-519-8794. The manual lists no owner fix for this code. (NCB-H user’s manual, p. 25)
For a technician
- Check the sensor connections. (NHB-H user’s manual, p. 24)
-
Combi-boilers and boilers: the external heating return temperature sensor is not detected.Ext. Return Sensor Not Detected
Combi-boilers and boilers: the external heating return temperature sensor is not detected. (NCB-H user’s manual, p. 25)
By model: Combi-boiler/boiler code only.
What you can check
- Call Navien Technical Support at 1-800-519-8794. The manual lists no owner fix for this code. (NCB-H user’s manual, p. 25)
For a technician
- Check the sensor connections. (NHB-H user’s manual, p. 24)
-
Heat-only boilers: the water coming back to the boiler is hotter than the water going out, which points to reversed piping.Return Temp. Exceeds Supply
Heat-only boilers: the water coming back to the boiler is hotter than the water going out, which points to reversed piping. (NHB-H user’s manual, p. 24)
By model: NHB-H and NFB-H boilers only. Not a water heater or combi-boiler code.
For a technician
- Check for reversed supply/return piping. (NHB-H user’s manual, p. 24)
-
Boilers only: the water pressure in the heating system is too low.Low Water Pressure
Boilers only: the water pressure in the heating system is too low. The NCB700 needs a manual reset after this. (NCB700 installation manual, p. 136)
By model: Not in any Navien tankless water heater manual. Some websites list E302 as a 'water flow sensor fault' on NPE water heaters; no Navien NPE document lists E302. On NCB-E/NCB-H combis the related low-water code is E351 instead.
Likely causes
- The built-in water pressure sensor detects insufficient water pressure in the boiler; the built-in low water cutoff’s minimum operating pressure is 6 psi by default. (NCB700 installation manual, p. 21)
What you can check
- Check the boiler’s water pressure. (NCB700 installation manual, p. 136)
- After the pressure problem is fixed, reset the boiler manually (Back button). (NCB700 installation manual, pp. 21, 116)
-
Combi-boilers: the boiler tried to refill its heating loop with water and did not finish within 5 minutes.Abnormal Auto feeder valve (make-up water)
Combi-boilers: the boiler tried to refill its heating loop with water and did not finish within 5 minutes. It needs a manual reset. (NCB-E user’s manual, p. 22)
By model: NCB-E and NCB-H combi-boilers only. Not on the NCB700 list (NCB700 uses E302 'Low Water Pressure').
Likely causes
- The water pressure sensor saw low water and the boiler started automatic refill; if refill is not completed after 5 minutes, E351 shows and a manual reset is required. (NCB-H installation manual, p. 20; NCB-E installation manual, p. 19)
What you can check
- Call Navien Technical Support at 1-800-519-8794. The manual lists no owner fix for this code. (NCB-E user’s manual, p. 22)
- Once the cause is fixed, the boiler needs a manual reset from the front panel. (NCB-H installation manual, p. 20)
-
Combi-boilers and boilers: the heating-system water pressure is too high.High water pressure
Combi-boilers and boilers: the heating-system water pressure is too high. (NCB-E user’s manual, p. 22)
By model: Combi-boiler/boiler code only.
What you can check
- Call Navien Technical Support at 1-800-519-8794. The manual lists no owner fix for this code. (NCB-E user’s manual, p. 22)
-
Combi-boilers and boilers: the water pressure sensor is not working right.Abnormal operation: water pressure sensor
Combi-boilers and boilers: the water pressure sensor is not working right. (NCB-E user’s manual, p. 22)
By model: Combi-boiler/boiler code only.
What you can check
- Call Navien Technical Support at 1-800-519-8794. The manual lists no owner fix for this code. (NCB-E user’s manual, p. 22)
For a technician
- Check the water pressure sensor (WPS). (NHB-H user’s manual, p. 24)
-
Heat-only boilers: the sensor in the indirect hot water tank is not detected.DHW Tank Sensor Not Detected
Heat-only boilers: the sensor in the indirect hot water tank is not detected. (NHB-H user’s manual, p. 24)
By model: NHB-H and NFB-H boilers only (boiler with an indirect tank). Not a tankless water heater code.
For a technician
- Check the tank sensor connections. (NHB-H user’s manual, p. 24)
-
NCB700: the control cannot talk to its real-time clock.RTC communication abnormality
NCB700: the control cannot talk to its real-time clock. (NCB700 installation manual, p. 137)
By model: NCB700 only.
What you can check
- Call Navien Technical Support at 1-800-519-8794. The manual lists no owner fix for this code. (NCB700 installation manual, p. 137)
-
Combi-boilers: the boiler is set to aquastat (pre-heat) mode but cannot detect the aquastat.Pump Aquastat Not Detected
Combi-boilers: the boiler is set to aquastat (pre-heat) mode but cannot detect the aquastat. (NCB-H user’s manual, p. 26)
By model: NCB-H and NCB700 only.
What you can check
- Select a recirculation/pre-heat option other than Aquastat mode. (NCB-H user’s manual, p. 26)
For a technician
- Check the Pre-Heat Aquastat wiring connection. (NCB-H user’s manual, p. 26)
-
Combi-boilers and boilers: the low water cutoff tripped because the heating system water is low.Abnormal operation: LWCO
Combi-boilers and boilers: the low water cutoff tripped because the heating system water is low. (NCB-E user’s manual, p. 22)
By model: Combi-boiler/boiler code only.
What you can check
- Make sure the heating-system water level is right, and add make-up water if needed. (NCB-H user’s manual, p. 26)
For a technician
- Check the LWCO (low water cutoff) wiring connection. (NCB-H user’s manual, p. 26)
-
Combi-boilers and boilers: the boiler lost communication with the zone controller.Zone Controller Communication
Combi-boilers and boilers: the boiler lost communication with the zone controller. (NCB-H user’s manual, p. 26)
By model: Combi-boiler/boiler code only.
What you can check
- Call Navien Technical Support at 1-800-519-8794. The manual lists no owner fix for this code. (NCB-H user’s manual, p. 26)
For a technician
- Check the zone controller wiring and settings. (NHB-H user’s manual, p. 24)
No Navien code matches that. Check the number on the display again, or look at the other brands.
Clearing a code
How to reset a Navien, and when to stop
To clear a code
- NPE-A2/S2: press the Back button on the front panel to reset. If that does not fix it, see Troubleshooting or call Technical Support at 1-800-519-8794. Settings are kept during a power outage. (NPE-2 user’s manual, pp. 10, 16)
- NPE-A2/S2: a 'level 1' error flashes the display red but the heater keeps running. Level 1 errors clear by themselves once the problem is fixed; pressing Back clears one if the problem is resolved. (NPE-2 installation manual, p. 96)
- NPE-A2/S2: the last 10 errors can be viewed under Menu > 3. Error History. (NPE-2 installation manual, p. 96)
- NPE-A/NPE-S: press the Reset button on the front panel. (NPE user’s manual, pp. 9, 15)
- NPN: press the Reset button on the front panel (indoor models), or press the OK button once on the remote controller (outdoor models); 'RST' appears on the remote. (NPN user’s manual, pp. 12, 21)
- NR-21DU remote (NPE-A2/S2, NPN): after the problem is fixed, press the OK button once; 'RST' shows on the screen. Resetting errors still works while the remote is in Lock mode. (NR-21DU remote manual, p. 26)
- NR-21DU remote: to turn off the scale (descale) alarm, press and hold OK for 2 seconds; 'RST' shows for 3 seconds. (NR-21DU remote manual, p. 27)
- NHW700: press the Reset button (universal/interior models) or press OK once on the remote for exterior models; 'RST' appears. (NHW700 user’s manual, pp. 12, 23)
- NCB-E combi-boiler: press the Reset button on the front panel. (NCB-E user’s manual, pp. 11, 21)
- NCB-H combi-boiler: press the Back button on the front panel to reset. (NCB-H user’s manual, pp. 13, 24)
- NCB700 combi-boiler: press the Back button on the front panel to reset. (NCB700 installation manual, p. 116)
- NHB-H boiler: press the Back button on the front panel to reset. (NHB-H user’s manual, p. 14)
- E351 (NCB-E, NCB-H) and E302 (NCB700) need a manual boiler reset after the water-pressure problem is fixed. (NCB-H installation manual, pp. 20 (NCB-H); NCB-E Installation Manual p. 19; NCB700 I&O Manual p. 21)
Navien’s safety notes
- WHAT TO DO IF YOU SMELL GAS: Do not try to light any appliance. Do not touch any electric switch; do not use any phone in your building. Call your gas supplier from a neighbor’s phone. If you cannot reach your gas supplier, call the fire department. (The same box is in every Navien heater and boiler manual read; it is not in the NR-21DU remote manual.) (NPE-2 user’s manual, pp. 1, 3)
- This appliance has no pilot. It lights the burner automatically. Do not try to light the burner by hand. (NPE-2 user’s manual, p. 3)
- Do not use the water heater if any part has been under water. Call a qualified service technician right away to inspect it and replace any control or gas control that was under water. (NPE-2 user’s manual, pp. 3, 6)
- If the water heater is damaged by overheating, fire, flood or anything else, close the manual gas shut-off valve and do not run it again until a qualified technician inspects it. (NPE-2 user’s manual, p. 5)
- Should overheating occur or the gas supply fail to shut off, turn off the manual gas valve to the appliance. (NPE-2 user’s manual, p. 6)
- Do not run the water heater with the front cover open (fire or carbon monoxide risk). Do not remove the front cover unless power is off or disconnected (shock risk). (NPE-2 user’s manual, pp. 5-6)
- Do not run the heater without proper venting. Turn it off and stop using it if any vent or intake pipe is damaged, separated at a joint, corroded, rusted or melted. (NPE-2 user’s manual, p. 5)
- Do not attempt to repair or replace any part of the water heater unless the manual specifically says to. For all other service, contact an authorized technician or licensed professional. (NPE-2 user’s manual, p. 6)
- NHW700 owner’s manual: 'Do NOT attempt to service or repair the water heater yourself.' (NHW700 user’s manual, p. 23)
- Navien says only limited troubleshooting can be done with a homeowner because the product involves water, electricity and gas; it recommends the original installer or a Navien Service Specialist. (Navien NPE-A2 FAQ page)
- All repairs require pre-authorization by Navien Technical Support. Have your installer or a licensed professional call 1-800-519-8794, Option 2, from the installation site. (NPE-2 installation manual, p. 145)
- Gas conversion (natural gas to propane) should only be done by a qualified service agency using Navien’s conversion kit. (Navien NPE-A2 FAQ page, pp. FAQ: 'Is the NPE-2 gas field convertible?')
- Freezing: damage from freezing is not covered by the Navien warranty. Do not unplug the heater except for routine maintenance; freeze protection needs electricity. Do not close the gas valve except for maintenance (A2 models). Drain the heater if power or gas will be off for a long time. (NPE-2 user’s manual, p. 15)
- If you think the heater is frozen: turn it off, close the gas valve, open the hot faucet closest to the heater, warm both heat exchangers with a hair dryer or portable electric heater, and check for leaks once water flows. If it leaks or does not work right, call an authorized technician or licensed professional. (NPE-2 user’s manual, p. 15)
- NCB-H combi-boiler: if hot water will not flow and you think the boiler is frozen, contact an authorized technician or licensed professional (no owner thaw steps given). (NCB-H user’s manual, p. 18)
- Flushing the heat exchanger is 'a somewhat complicated procedure.' If unsure about any step, contact an authorized technician or licensed professional; improper maintenance can void the warranty. (NPE-2 user’s manual, p. 12)
- Vent Installation Detector (E762) is not an alarm, safety switch or substitute for a carbon monoxide detector. A vent pipe not fully inserted can separate and leak flue gas with carbon monoxide. (NPE-2 installation manual, p. 45)
- Scald risk: the heater is factory set to 120 F. Water at or above 125 F can cause instant scalding, severe burns or death. (NPE-2 user’s manual, p. 4)
- No Navien document read gives a 'do not reset more than N times' limit. (NPE-2 user’s manual)
Heater getting old, or the same code keeps coming back? Repair or replace? Three taps and Dan’s answer → Or see what a water heater repair usually involves.
Which one do you have?
The Navien heaters these codes cover
- NPE-A2 and NPE-S2: condensing tankless, current seriesNPE-180A2, NPE-210A2, NPE-240A2, NPE-150S2, NPE-180S2, NPE-210S2, NPE-240S2 · 'E' plus a 3-digit code on the front panel LCD; the display flashes red and the error icon flashes. The optional NR-21DU remote shows the same 3-digit code with a flashing red LED.
- NPE-A and NPE-S: condensing tankless, earlier seriesNPE-180A, NPE-210A, NPE-240A, NPE-150S, NPE-180S, NPE-210S, NPE-240S · 'E' plus a 3-digit code on the front panel display, with an Error indicator; front panel has a Reset button.
- NPN: non-condensing tanklessNPN-160U, NPN-180U, NPN-199U, NPN-120E, NPN-160E, NPN-180E, NPN-199E · Indoor (U) models: 'E' plus a 3-digit code on the front panel. Outdoor (E) models: code on the NR-21DU remote controller with a red LED.
- NHW700: non-condensing tankless, newest seriesNHW700-120SE, NHW700-160SE, NHW700-180SE, NHW700-199SE, NHW700-160SU, NHW700-180SU, NHW700-199SU, NHW700-160AI, NHW700-180AI, NHW700-199AI, NHW700-160AE, NHW700-180AE, NHW700-199AE · Front panel (universal/interior models) or remote controller (exterior models). Navien’s public owner’s manual has no code table for this line.
- NCB-E combi-boiler (heat and hot water)NCB-150E, NCB-180E, NCB-210E, NCB-240E · 'E' plus a 3-digit code on the front panel display; front panel has a Reset button.
- NCB-H combi-boiler (heat and hot water)NCB-190/060H, NCB-190/080H, NCB-240/110H, NCB-240/130H, NCB-250/150H · 'E' plus a 3-digit code on the front panel display; reset with the Back button.
- NCB700 combi-boiler (heat and hot water)NCB700-190/060, NCB700-190/080, NCB700-240/110, NCB700-240/130, NCB700-250/150 · 'E' plus a 3-digit code on the front panel display; reset with the Back button.
- NHB-H boiler (heat only)NHB-055H, NHB-080H, NHB-110H, NHB-150H · Code on the front panel display.
- NFB-H fire-tube boiler (heat only)NFB-175H, NFB-200H · Code on the front panel display.
Common questions
Navien error code questions
Is Navien E001 an ignition failure?
No. In Navien’s manuals E001 is “Heat Exchanger Overheat,” and it’s listed only for the NCB-H and NCB700 combi-boilers and the NHB-H and NFB-H boilers. Navien’s ignition failure code is E003.
What is the Navien descaling code?
E760, “Flushing/service alarm.” On the NR-21DU remote it shows as A.760. It’s a reminder that the heat exchanger is due to be flushed, not a breakdown. E445 is something else: the bypass mixing valve.
How do I reset a Navien tankless water heater?
On an NPE-A2 or NPE-S2, press the Back button. On an NPE-A, NPE-S or indoor NPN, press Reset. With the NR-21DU remote, press OK once and RST shows on the screen. If the code comes back, call your installer or Navien Technical Support at 1-800-519-8794.
What do the two digits after a Navien code mean, like E110 01?
They narrow down the cause, and Navien’s service manuals define some of them. On an NPE-A or NPE-S, E110-1 is an exhaust blockage found while checking the fan, E110-2 while using hot water and E110-3 while heating. The service manuals also list sub-codes for E060, E515, E615 and others. Each code’s entry here shows the ones Navien lists.
Where this comes from
Sources
Every meaning, cause and step on this page is from Navien’s own documents, checked November 13, 2026. Page numbers are the printed page. We left out codes we only found on forums.
- User’s Information Manual - NPE Condensing Water Heaters (NPE-180A2, NPE-210A2, NPE-240A2, NPE-180S2, NPE-210S2, NPE-240S2) Navien, Inc. · 20049624A · Version 1.0 (2020); PDF file NPE-A2_S2_User’s_Information_Manual_EN_CAFR_201202 · Models: NPE-180A2, NPE-210A2, NPE-240A2, NPE-180S2, NPE-210S2, NPE-240S2
- Installation Manual - NPE Condensing Water Heaters (NPE-180A2/210A2/240A2, NPE-150S2/180S2/210S2/240S2) Navien, Inc. · 20049624B · Version 2.0 (January, 2026) · Models: NPE-180A2, NPE-210A2, NPE-240A2, NPE-150S2, NPE-180S2, NPE-210S2, NPE-240S2
- NR-21DU Remote Controller manual (Navien NPE remote controller manual) Navien, Inc. · 20051848A · not printed (PDF dated May 2021) · Models: NR-21DU remote used with NPE-A2/S2 and NPN
- User’s Information Manual - NPE Condensing Water Heaters (NPE-180A, NPE-210A, NPE-240A, NPE-150S, NPE-180S, NPE-210S, NPE-240S) Navien, Inc. · 20026535G · Version 5.3 (May 23, 2019) · Models: NPE-180A, NPE-210A, NPE-240A, NPE-150S, NPE-180S, NPE-210S, NPE-240S
- Operation Manual - NPE Condensing Water Heaters (NPE-180A/210A/240A, NPE-150S/180S/210S/240S) Navien, Inc. · Version 5.1 (Feb. 25, 2016) · Models: NPE-180A, NPE-210A, NPE-240A, NPE-150S, NPE-180S, NPE-210S, NPE-240S
- User’s Information Manual - NPN Non-Condensing Water Heaters (NPN-160U/180U/199U, NPN-120E/160E/180E/199E) Navien, Inc. · 20045995B · Version 1.0 (December 2020) · Models: NPN-160U, NPN-180U, NPN-199U, NPN-120E, NPN-160E, NPN-180E, NPN-199E
- Installation Manual - NPN Non-Condensing Water Heaters (NPN-160U/180U/199U, NPN-120E/160E/180E/199E) Navien, Inc. · 20045995C · Version 1.0 (June 2021) · Models: NPN-160U, NPN-180U, NPN-199U, NPN-120E, NPN-160E, NPN-180E, NPN-199E
- User’s Information Manual - NHW700 Non-Condensing Water Heaters Navien, Inc. · Version 1.1 (November, 2023) · Models: NHW700-160SE/180SE/199SE, NHW700-160SU/180SU/199SU, NHW700-160AI/180AI/199AI, NHW700-160AE/180AE/199AE
- Installation Manual - NHW700 Non-Condensing Water Heaters Navien, Inc. · Version 1.1 (February, 2024) · Models: NHW700-120SE/160SE/180SE/199SE, NHW700-160SU/180SU/199SU, NHW700-160AI/180AI/199AI, NHW700-160AE/180AE/199AE
- User’s Information Manual - NCB-E Condensing Combi-Boilers (NCB-150E/180E/210E/240E) Navien, Inc. · 20035566B · Version 6.0 (May 27, 2019) · Models: NCB-150E, NCB-180E, NCB-210E, NCB-240E
- Installation & Operation Manual - NCB-E Condensing Combi-Boilers (NCB-150E/180E/210E/240E) Navien, Inc. · 20035566B (as printed) · Version 7.0 (Dec 06, 2019) · Models: NCB-150E, NCB-180E, NCB-210E, NCB-240E
- User’s Information Manual - NCB-H Condensing Combi-Boilers (NCB-190/060H ... NCB-250/150H) Navien, Inc. · Version 1.0 (April, 2024) · Models: NCB-190/060H, NCB-190/080H, NCB-240/110H, NCB-240/130H, NCB-250/150H
- Installation & Operation Manual - NCB-H Condensing Combi-Boilers Navien, Inc. · Version 1.0 (February, 2024) · Models: NCB-190/060H, NCB-190/080H, NCB-240/110H, NCB-240/130H, NCB-250/150H
- Installation & Operation Manual - NCB700 Condensing Combi-Boilers Navien, Inc. · Version 1.0 (July, 2026) · Models: NCB700-190/060, NCB700-190/080, NCB700-240/110, NCB700-240/130, NCB700-250/150
- User’s Information Manual - NHB-H Condensing Boilers (NHB-055H/080H/110H/150H) Navien, Inc. · Version 1.0 (April, 2024) · Models: NHB-055H, NHB-080H, NHB-110H, NHB-150H
- User’s Information Manual - NFB-H Condensing Boilers (NFB-175H/200H) Navien, Inc. · Version 1.0 (April, 2024) · Models: NFB-175H, NFB-200H
- NPE-A2 FAQs (Navien support web page) Navien, Inc. · read 2026-11-13 · Models: NPE-A2 series
- Service Manual - NPE Condensing Water Heaters (NPE-180A2, NPE-210A2, NPE-240A2, NPE-180S2, NPE-210S2, NPE-240S2, NPE-150S2) Navien, Inc. · file NPE-A2_S2_Service_Manual_EN_250122 · Version 1.1 (January, 2025) on back cover; revision table shows 1.00 First Issue March 24, 2020 · Models: NPE-180A2, NPE-210A2, NPE-240A2, NPE-180S2, NPE-210S2, NPE-240S2, NPE-150S2
- Service Manual - NPE Condensing Water Heaters (NPE-180A, NPE-210A, NPE-240A, NPE-150S, NPE-180S, NPE-210S, NPE-240S) Navien, Inc. · file NPE_Service_Manual_EN_200130 · Version 2.40 (Jan. 2020) on back cover; page footers say Version 2.21 · Models: NPE-180A, NPE-210A, NPE-240A, NPE-150S, NPE-180S, NPE-210S, NPE-240S
- Service Manual - NPN Non-Condensing Water Heaters (NPN-160U, NPN-180U, NPN-199U, NPN-160E, NPN-180E, NPN-199E) Navien, Inc. · file NPN_Service_Manual_EN_250108 · Version 1.0 (January, 2025) on back cover; revision table shows 1.0 First Issue September 2019 · Models: NPN-160U, NPN-180U, NPN-199U, NPN-160E, NPN-180E, NPN-199E
Other brands
Error codes for other water heaters
Water heater help
More about water heaters
Code won’t clear?
If you’re within about 30 miles of Westlake Village, call or text Dan a photo of the display and the label. He’ll tell you what it is.
Or send the details and Dan will call you back. Monday to Friday, 9am – 5pm.