Gas tanks, Vertex, tankless and heat pumps · 272 codes · Checked November 2026
A.O. Smith error codes, in plain words
A.O. Smith gas tanks talk through a status light that flashes a count. Power-vent and Vertex models show patterns or messages, and the tankless and heat pump models show number codes. Here’s every code in A.O. Smith’s manuals, in plain words. The same count means different things on different tanks, so start with what you have.
From Dan and Dave at Dan's Plumbing, a family plumbing shop in Westlake Village, California. Every line below comes from A.O. Smith’s own documents, with the page it’s on.
Smell gas? Don’t touch any switch or try to reset anything. Leave the house, then call 911 or your gas company from outside. In Southern California that’s SoCalGas, 1-800-427-2200.
Every code
All 272 A.O. Smith codes
Gas tanks with a status light
Standard and Ultra Low NOx atmospheric and direct-vent tanks. One flash every 3 seconds is normal. Other counts are codes.
-
The status light is dark.0 FLASHES (LED NOT LIT)
The status light is dark. The pilot flame is out, or it has not made enough power yet to run the gas control. The heater will not heat. (Ultra Low NOx tank guide (2021), p. 27)
By model: The standard ProLine chart (100263112, an image on p. 27) and the ULN charts say 'Pilot light is not lit. Not enough power (millivolts) to keep it lit.' The high-recovery, direct-vent and Signature charts word it 'Pilot light is not lit or Thermopile has not yet reached normal operating temperature' and give a longer relight procedure.
Likely causes
- Pilot light is not lit, or not enough power (millivolts) to keep it lit. (Gas tank guide 100263112, p. 27)
- The thermopile has not warmed up yet. It can take up to 90 seconds of steady pilot before the light starts to blink. (ProLine high recovery guide, p. 34)
- A new installation has air in the gas line; it can take several lighting attempts to clear it. (Gas tank guide 100263112, p. 23)
- Pilot is lit but the light never blinks: weak pilot not heating the thermopile, a defective thermopile, or loose wiring connectors. (ProLine high recovery guide, p. 34)
What you can check
- Make sure the manual gas valve in the heater’s supply line is ON. (Gas tank guide 100263112, p. 23)
- Relight using the label instructions: knob to PILOT, hold it in and click the igniter about once a second for up to 90 seconds until the light flashes once every 3 seconds. (Gas tank guide 100263112, p. 23)
- If it will not light after 90 seconds, release the knob and wait 10 minutes before trying again; try at least two more times. (Gas tank guide 100263112, p. 23)
- Dim the room lights and look through the viewport while clicking the igniter to see if there is a spark. (Gas tank guide 100263112, p. 25)
For a technician
- If there is no spark, make sure the igniter wire is firmly inserted into the white connector. (Gas tank guide 100263112, p. 25)
- If the light still won’t blink after three tries: confirm the unit is getting gas, remove the outer door, press the reset button, replace the door, wait 10 minutes and relight. (ProLine high recovery guide, p. 34)
- If no pilot is visible, check the spark igniter or the gas supply to the pilot. (ProLine high recovery guide, p. 34)
- Check thermopile output in millivolts at the connector with the pilot lit: below 350 mV replace the thermopile; above 350 mV with secure wiring, replace the gas valve. (Electronic gas valve sheet, p. 1)
- If the heater had been running and now won’t relight, inspect the flame arrestor for blue/black discoloration (flammable vapor incident); if found, the whole water heater must be replaced. (ProLine high recovery guide, p. 34)
-
The light stays on without blinking.LIGHT ON (SOLID) / RED LIGHT ON (SOLID)
The light stays on without blinking. The pilot just went out (or you just turned the knob off) and the control is cooling down. You have to wait before relighting. (ProLine high recovery guide, p. 34)
By model: Direct-vent manuals call it 'RED LIGHT ON (SOLID)'. Signature (Lowe’s) manual: 'A solid red light indicates that the gas control valve/thermostat is shutting down' (100341468 p. 25).
Likely causes
- A solid status light means the pilot was lit but is now off. (Gas tank guide 100263112, p. 23)
- After you turn the knob to OFF, the light stops blinking and stays on for a short time. (Gas tank guide 100263112, p. 23)
- Continuous light indicates the gas control valve/thermostat is shutting down. (Ultra Low NOx tank guide (2015), p. 21)
- Signature 100 (Lowe’s): a solid red light indicates that the gas control valve/thermostat is shutting down. (Signature 100 guide, p. 25)
What you can check
- Turn the knob to OFF and wait 10 minutes for the thermopile to cool, then relight following the label. The control will not allow a relight sooner. (ProLine high recovery guide, p. 34)
- Once the light goes out, repeat the lighting steps. (Gas tank guide 100263112, p. 23)
-
This is normal.1 FLASH (EVERY 3 SECONDS)
This is normal. The pilot is lit and the gas control sees no problem. (Gas tank guide 100263112, p. 25)
By model: An A. O. Smith University training sheet (ElecValve_AOS, 2016) says the status light 'must flash once per second' for the heater to operate. Every current A. O. Smith manual checked says once every 3 seconds; treat the training sheet as outdated or for a different valve.
What you can check
- If the light flashes once every 3 seconds but you have no hot water, make sure the gas control knob is set to HOT (not VAC or PILOT). (Gas tank guide 100263112, p. 25)
- If the water is only lukewarm, check faucets and shower valves with built-in mixing valves; a failed mixing valve can limit hot water even when the tank is hot. (Gas tank guide 100263112, p. 25)
-
The pilot is lit, but the thermopile (the part the pilot flame heats to make power) is not making enough power for the gas control.2 FLASHES
The pilot is lit, but the thermopile (the part the pilot flame heats to make power) is not making enough power for the gas control. (Ultra Low NOx tank guide (2021), p. 27)
By model: Same meaning on every status-light chart checked.
Likely causes
- The thermopile is probably defective, but loose wiring connections or a weak pilot flame can also cause this. (ProLine high recovery guide, p. 34)
What you can check
- Turn the gas control knob to OFF. (ProLine high recovery guide, p. 34)
For a technician
- Check all wiring connections; if the problem persists, replace the thermopile (pilot/thermopile assembly). (Ultra Low NOx tank guide (2021), p. 27)
- ULN models: if the pilot keeps going out and the status light gives a two-flash code, follow 'Replacing the Pilot Assembly'. (Ultra Low NOx tank guide (2015), p. 31)
-
The water got too hot and the safety shutoff (ECO) inside the gas control tripped.4 FLASHES
The water got too hot and the safety shutoff (ECO) inside the gas control tripped. It shuts off the burner and the pilot. The gas control has to be replaced. (Ultra Low NOx tank guide (2021), p. 27)
By model: Same meaning on every status-light chart checked.
Likely causes
- The gas control’s temperature sensor detected water that was too hot; the main burner and pilot shut off. Because the pilot is off, the code only shows right after the pilot is relit. (ProLine high recovery guide, p. 34)
- ULN models: the ECO in the gas control shuts the heater off if water exceeds 189°F (87°C). (Ultra Low NOx tank guide (2015), p. 22)
What you can check
- Turn the gas control knob to OFF and turn the main gas supply to the heater OFF. (ProLine high recovery guide, p. 34)
For a technician
- Relight the pilot and confirm 4 flashes; if confirmed, knob OFF, main gas OFF, and replace the gas control valve/thermostat. (ProLine high recovery guide, p. 34)
- If the ECO has functioned, the gas control valve/thermostat should be replaced by a qualified person. (Ultra Low NOx tank guide (2015), p. 22)
-
The water temperature sensor has failed.5 FLASHES
The water temperature sensor has failed. (Ultra Low NOx tank guide (2021), p. 27)
By model: Fix differs by model: standard, ULN, high-recovery, mobile-home and Signature charts say replace the gas control valve/thermostat; the direct-vent charts (GDV, GDVN; 100398943 p. 27, 100369451 p. 28) say replace the temperature sensor (thermistor). The standard chart (100263112 p. 27) calls it just 'Sensor failure'.
Likely causes
- The temperature sensor (thermistor) is defective. (ProLine high recovery guide, p. 35)
What you can check
- Turn the gas control knob to OFF and turn the main gas supply to the heater OFF. (ProLine high recovery guide, p. 35)
For a technician
- Replace the gas control valve/thermostat. (Ultra Low NOx tank guide (2021), p. 27)
- Direct-vent models: replace the temperature sensor (thermistor). (Direct vent tank guide, p. 27)
- Direct-vent Ultra-Low NOx models: replace the temperature sensor (thermistor). (Direct vent ULN guide, p. 28)
-
The gas control valve itself has failed and must be replaced.7 FLASHES
The gas control valve itself has failed and must be replaced. (Ultra Low NOx tank guide (2021), p. 27)
By model: Same meaning on every status-light chart checked. Do not confuse with the flue-damper and power-vent families, where 7 flashes means a flammable vapor sensor lockout.
Likely causes
- Gas control valve failure. (ProLine high recovery guide, p. 35)
- ULN status-light list: 7 flashes indicates electronic control failure. (Ultra Low NOx tank guide (2015), p. 21)
What you can check
- Turn the gas control knob to OFF and turn the main gas supply to the heater OFF. (ProLine high recovery guide, p. 35)
For a technician
- Replace the gas control valve/thermostat. (Ultra Low NOx tank guide (2021), p. 27)
- Mobile-home models: same chart, replace the gas control valve/thermostat. (Manufactured home tank guide, p. 26)
-
You turned the knob to OFF, but the control still sees power from the thermopile.8 FLASHES
You turned the knob to OFF, but the control still sees power from the thermopile. Either the thermopile is cooling slowly, or the pilot valve is stuck open and the pilot is still burning. (Ultra Low NOx tank guide (2021), p. 27)
By model: Same meaning on every status-light chart checked.
Likely causes
- The thermopile did not cool down as quickly as expected after shutoff. (Ultra Low NOx tank guide (2021), p. 27)
- The pilot keeps burning with the knob OFF because the pilot valve is stuck open. (Ultra Low NOx tank guide (2021), p. 27)
What you can check
- Make sure the gas control knob is set to OFF and wait one minute. (Ultra Low NOx tank guide (2021), p. 27)
For a technician
- Remove the outer door and look through the sight glass. If a pilot flame is burning with the knob at OFF, the pilot valve is stuck open: turn the main gas OFF and replace the gas control. (Ultra Low NOx tank guide (2021), p. 27)
- If no pilot flame is seen, wait 10 minutes for the thermopile to cool and relight per the label; if 8 flashes return, replace the gas control. (Ultra Low NOx tank guide (2021), p. 27)
-
The sensor that watches the temperature in the burner chamber has a broken or shorted circuit.9 FLASHES
The sensor that watches the temperature in the burner chamber has a broken or shorted circuit. (Ultra Low NOx tank guide (2021), p. 27)
By model: Only on the Ultra-Low NOx atmospheric models (100263190, 100347101). Not on the standard, direct-vent or high-recovery charts.
Likely causes
- Chamber temperature sensor circuit is open or shorted. (Ultra Low NOx tank guide (2015), p. 21)
For a technician
- Check all connections; if the problem persists, replace the temperature sensor; if it still persists, replace the gas control valve/thermostat. (Ultra Low NOx tank guide (2021), p. 27)
-
The heater shut itself down because the burner chamber sensor detected a problem the manual calls an 'LDO occurrence' (contaminants).10 FLASHES
The heater shut itself down because the burner chamber sensor detected a problem the manual calls an 'LDO occurrence' (contaminants). This is tied to lint, dust or oil build-up, or poor combustion from a blocked vent or too little combustion air. (Ultra Low NOx tank guide (2021), p. 27)
By model: Only on the Ultra-Low NOx atmospheric models. The manuals do not spell out what 'LDO' stands for. Correct the cause before resetting (100263190 p. 22).
Likely causes
- Excessive contaminants in the combustion chamber. (Ultra Low NOx tank guide (2015), p. 21)
- The chamber temperature sensor shuts off gas if poor combustion is sensed (caused by a blocked vent or insufficient combustion air). (Ultra Low NOx tank guide (2015), p. 22)
- Flame-trap or burner clogged with debris from excessive lint, dirt, dust or oil. (Ultra Low NOx tank guide (2015), p. 31)
What you can check
- Look for a blocked vent and make sure the heater gets enough combustion air. (Ultra Low NOx tank guide (2015), p. 22)
For a technician
- Reset: knob OFF, unplug the thermopile plug from the gas control, wait about three minutes, plug it back in, knob to PILOT, relight per the manual. (Ultra Low NOx tank guide (2021), p. 27)
- If it persists, follow 'Cleaning the Combustion Chamber and Flame-Trap'. (Ultra Low NOx tank guide (2021), p. 27)
- If it still persists, shut off the gas supply to the heater and contact A. O. Smith customer service / technical assistance. (Ultra Low NOx tank guide (2021), p. 27)
Flue damper gas tanks (ProLine XE)
Plug-in tanks with a damper on the vent. The light uses different patterns, and Ultra Low NOx models add a second light on the LDO module.
-
Normal standby.Short Flash once every four seconds
Normal standby. The heater is not heating right now and sees no problem. (Flue damper tank guide, p. 27)
By model: Different from the atmospheric status-light family, where normal is once every 3 seconds.
What you can check
- If the light flashes once every four seconds and you have no hot water, make sure the gas control knob is set high enough. (Flue damper tank guide, p. 25)
-
Normal.“Heartbeat”, alternates bright/dim
Normal. The heater is calling for heat. (Flue damper tank guide, p. 27)
-
The flame sensor is reading a weak flame.One Flash, three second pause
The flame sensor is reading a weak flame. The heater keeps running for now. (Flue damper tank guide, p. 27)
By model: Not the same as '1 flash' on the atmospheric status-light family (normal) or the power-vent family (also low flame signal).
For a technician
- Check incoming gas pressure; check that all wiring and harness connections are firmly seated; check the base ring filter and flame arrestor for clogging; remove the burner assembly and inspect the manifold tube, burner and the electrode/flame sense rod; replace the igniter/pilot assembly if damaged. (Flue damper tank guide, p. 27)
-
The flue damper on top of the heater is not proving it is closed.Two Flash, three second pause
The flue damper on top of the heater is not proving it is closed. The heater will not try to light. (Flue damper tank guide, p. 27)
By model: On the power-vent / power-direct-vent family, Two Flash means 'Pressure Switch Failed Closed' instead.
Likely causes
- Damper is closed when it should be open, or not closing; the control will not attempt to light (2-flash code). (Flue damper tank guide, p. 29)
What you can check
- Look at the top of the heater to see if the damper is open. If something blocks it from closing, turn the power switch on the gas control OFF, remove the obstruction, then turn the switch back ON. (Flue damper tank guide, p. 27)
For a technician
- If there is no obstruction and the damper won’t close: unplug the heater, check all harness and wire connections, replace damaged parts; if the problem persists, replace the damper. (Flue damper tank guide, p. 27)
-
Either the flue damper did not prove it opened, or the thermal cutoff (TCO) on the burner door tripped.Three Flash, three second pause
Either the flue damper did not prove it opened, or the thermal cutoff (TCO) on the burner door tripped. (Flue damper tank guide, p. 27)
By model: GCF manual (100400765) adds the TCO limit lockout to this code; the GUF ULN manual (100366638 p. 28) lists only 'End Switch Failed Open'. On the power-vent family Three Flash means 'Pressure Switch Failed Open'.
Likely causes
- The gas valve tries to open the damper for 30 seconds, waits 2 minutes and tries again; if the damper never proves open, it shows 3 flashes. (Flue damper tank guide, p. 29)
What you can check
- Turn the power switch on the gas control OFF and unplug the heater before checking anything. (Flue damper tank guide, p. 27)
For a technician
- Try to press the TCO door switch button; if it depresses (it had tripped), clean the filter and flame arrestor, then relight. (Flue damper tank guide, p. 27)
- Relight and watch the damper; if there is a call for heat and the damper does not open, check wiring and replace the damper. (Flue damper tank guide, p. 27)
-
The over-temperature safety (ECO) in the gas control tripped because the water got too hot.Four Flash, three second pause
The over-temperature safety (ECO) in the gas control tripped because the water got too hot. (Flue damper tank guide, p. 27)
By model: ULN manual calls it 'ECO Limit Lockout (Overheat Failure)' (100366638 p. 27).
What you can check
- Turn the power switch on the gas control to OFF, wait 10-20 seconds, then turn it back ON. (Flue damper tank guide, p. 27)
For a technician
- If the problem persists after the power reset, replace the gas control valve/thermostat. (Flue damper tank guide, p. 27)
-
The control saw a flame when it should not have (flame out of sequence).Five Flash, three second pause
The control saw a flame when it should not have (flame out of sequence). (Flue damper tank guide, p. 27)
By model: ULN manual wording: 'Flame Out of Sequence' (100366638 p. 28). On the atmospheric status-light family 5 flashes means a temperature sensor failure.
Likely causes
- After heating ends and the valves close, a flame is still sensed: 5-flash code. (Flue damper tank guide, p. 29)
What you can check
- Turn the power switch on the gas control OFF, wait 10 minutes, then follow the lighting instructions. (Flue damper tank guide, p. 27)
For a technician
- If the problem persists, replace the gas control valve/thermostat. (Flue damper tank guide, p. 27)
-
The heater tried to light and failed too many times.Six-One Flash, three second pause
The heater tried to light and failed too many times. It is in a 20-minute soft lockout. (Flue damper tank guide, p. 28)
Likely causes
- No pilot flame sensed within 1.5 minutes: will not light, 6-1 code. (Flue damper tank guide, p. 29)
What you can check
- Turn the power switch on the gas control OFF, unplug the heater, plug it back in, then follow the lighting instructions. (Flue damper tank guide, p. 28)
For a technician
- If that fails: check incoming gas pressure, all wiring/harness connections, the base ring filter and flame arrestor, then remove the burner assembly to inspect the manifold tube, burner and electrode/flame sense rod; replace the igniter/pilot assembly if damaged. (Flue damper tank guide, p. 28)
-
Soft lockout: the flame was lost because the damper end switch failed during heating.Six-Two Flash, three second pause
Soft lockout: the flame was lost because the damper end switch failed during heating. (Flue damper tank guide, p. 28)
By model: On the power-vent family Six-Two means 'Recycle Limit - Pressure Switch/High Limit opened'.
What you can check
- Turn the power switch on the gas control OFF and unplug the heater. (Flue damper tank guide, p. 28)
For a technician
- Check all wiring/harness connections; replace damaged parts; if no connection problem is found or it persists, replace the damper. (Flue damper tank guide, p. 28)
-
Soft lockout: the flame kept going out during heating.Six-Three Flash, three second pause
Soft lockout: the flame kept going out during heating. (Flue damper tank guide, p. 28)
Likely causes
- Main flame not sensed: will not light, 6-3 code. (Flue damper tank guide, p. 29)
What you can check
- Turn the power switch on the gas control OFF and unplug the heater. (Flue damper tank guide, p. 28)
For a technician
- Check incoming gas pressure, wiring, base ring filter and flame arrestor; remove the burner assembly and inspect the manifold tube, burner and electrode/flame sense rod. (Flue damper tank guide, p. 28)
-
Soft lockout: a flame was still sensed after the burner should have shut off.Six-Four Flash, three second pause
Soft lockout: a flame was still sensed after the burner should have shut off. The damper closes and the control locks out for 20 minutes. (Flue damper tank guide, p. 28)
Likely causes
- Damper closes, 6-4 code, gas control goes into a 20-minute lockout; if flame is still sensed after 30 seconds, the damper re-opens. (Flue damper tank guide, p. 29)
What you can check
- Turn the power switch OFF, unplug the heater, wait 10 minutes, then follow the lighting instructions. (Flue damper tank guide, p. 28)
For a technician
- If the problem persists, replace the gas control valve/thermostat. (Flue damper tank guide, p. 28)
-
The flammable vapor sensor detected vapors (like gasoline, paint or solvents) near the heater and locked it out.Seven Flash, three second pause
The flammable vapor sensor detected vapors (like gasoline, paint or solvents) near the heater and locked it out. (Flue damper tank guide, p. 28)
By model: On the atmospheric status-light family, 7 flashes means gas control failure instead.
What you can check
- Do not touch any electrical switch, do not use any phone in the building, and do not try to light any appliance. (Flue damper tank guide, p. 28)
- Smell around the heater for a gas leak at the gas control or supply line, or other flammable vapors. (Flue damper tank guide, p. 28)
- Remove anything that can give off flammable vapors (gasoline, paint, thinners, varnish, cleaners) and store it in a different location. (Flue damper tank guide, p. 28)
For a technician
- Contact a qualified service representative to inspect and/or replace the FV sensor. (Flue damper tank guide, p. 28)
-
The flammable vapor sensor circuit has a fault.Eight-One Flash, three second pause
The flammable vapor sensor circuit has a fault. (Flue damper tank guide, p. 28)
What you can check
- Turn the power switch on the gas control to OFF, wait 10-20 seconds, then turn it back ON. (Flue damper tank guide, p. 28)
For a technician
- If it persists, replace the gas control valve/thermostat. (Flue damper tank guide, p. 28)
-
The water temperature sensor in the gas control has a fault.Eight-Two Flash, three second pause
The water temperature sensor in the gas control has a fault. (Flue damper tank guide, p. 28)
By model: ULN overview adds '(No Light)' (100366638 p. 27).
What you can check
- Turn the power switch on the gas control to OFF, wait 10-20 seconds, then turn it back ON. (Flue damper tank guide, p. 28)
For a technician
- If it persists, replace the gas control valve/thermostat. (Flue damper tank guide, p. 28)
-
The gas control’s electronics found an internal fault.Eight-Three Flash, three second pause
The gas control’s electronics found an internal fault. (Flue damper tank guide, p. 28)
Likely causes
- Pilot or main valve will not open: 8-3 or 8-4 code. (Flue damper tank guide, p. 29)
What you can check
- Turn the power switch on the gas control to OFF, wait 10-20 seconds, then turn it back ON. (Flue damper tank guide, p. 28)
For a technician
- If it persists, replace the gas control valve/thermostat. (Flue damper tank guide, p. 28)
-
The gas control valve has a fault.Eight-Four Flash, three second pause
The gas control valve has a fault. (Flue damper tank guide, p. 28)
By model: On the ULN GUF sequence chart, failed pilot/main ignition is shown as 8-4, while the GCF chart shows 6-1 / 6-3 for the same steps (100400765 p. 29 vs 100366638 p. 31).
Likely causes
- Pilot or main valve will not open: 8-3 or 8-4 code. (Flue damper tank guide, p. 29)
- ULN sequence chart: pilot flame not sensed within 1.5 minutes, main valve not opening, or main flame not sensed are all shown as 8-4. (Flue damper ULN guide, p. 31)
What you can check
- Turn the power switch on the gas control to OFF, wait 10-20 seconds, then turn it back ON. (Flue damper tank guide, p. 28)
For a technician
- If it persists, replace the gas control valve/thermostat. (Flue damper tank guide, p. 28)
-
The gas-control light is dark because the separate LDO module has locked the heater out.No Flash
The gas-control light is dark because the separate LDO module has locked the heater out. Read the LDO module’s own light. (Flue damper ULN guide, p. 27)
What you can check
- Look at the status light on the LDO module (location shown on page 2 of the manual) and match it to the LDO table. (Flue damper ULN guide, p. 30)
-
The LDO module is working normally.LDO Module - Normal Operation (1 sec. heartbeat)
The LDO module is working normally. (Flue damper ULN guide, p. 30)
By model: The LDO table shows the light patterns as pictures: one flash with a 1-second gap.
-
The LDO module reports a burner failure; the gas-control light is off.LDO Module - Burner Failure
The LDO module reports a burner failure; the gas-control light is off. (Flue damper ULN guide, p. 30)
By model: Pictured as one flash with a 4-second gap.
For a technician
- Replace the burner, then press and hold the LDO module reset button for 3 seconds to clear the code. (Flue damper ULN guide, p. 30)
-
The LDO module detected lint or dust build-up and shut the heater down.LDO Module - Lint Build-Up Detected
The LDO module detected lint or dust build-up and shut the heater down. (Flue damper ULN guide, p. 30)
By model: Pictured as three flashes with a 1-second gap.
For a technician
- Remove lint and dust build-up and make sure gas supply pressure is correct; main power must be cycled to clear the code. (Flue damper ULN guide, p. 30)
-
The LDO module’s chamber temperature sensor has failed or is unplugged.LDO Module - Chamber Sensor Failure
The LDO module’s chamber temperature sensor has failed or is unplugged. (Flue damper ULN guide, p. 30)
By model: Pictured as two flashes with a 4-second gap.
For a technician
- Make sure the sensor is connected properly to the LDO module; replace the chamber sensor (Figure 50). The code clears when the condition clears. (Flue damper ULN guide, p. 30)
Power vent and power direct vent gas tanks
A fan on top and a hot surface igniter. Same idea, different patterns: count the flashes, and for 6 and 8 count the second set too.
-
Normal standby.Short flash once every four seconds
Normal standby. Not heating right now; no fault. (Power vent manual, p. 55)
-
Normal.“Heartbeat”, alternates bright/dim
Normal. The heater is heating. (Power vent manual, p. 55)
-
The flame sensor is reading a weak flame.One Flash, three second pause
The flame sensor is reading a weak flame. The heater keeps running for now. (Power vent manual, p. 55)
For a technician
- Flame rod not properly seated in the flame: reposition it; clean the flame sensor rod with fine steel wool. (Power direct vent manual, p. 57)
-
The air pressure switch reads 'closed' before the blower runs.Two Flash, three second pause
The air pressure switch reads 'closed' before the blower runs. The heater will not start. (Power vent manual, p. 55)
By model: On the flue-damper family, Two Flash means 'End Switch Failed Closed'.
Likely causes
- Air pressure switch contacts stuck closed, or the switch is bypassed (jumpered), or wiring is wrong. (Power direct vent manual, p. 57)
For a technician
- Check that the blower runs without blockage; check wiring; check the air pressure sensing tubes are connected and not kinked; make sure the N.O. pressure switch is correct and not jumpered; with power OFF and wires off, check its continuity: closed = replace the switch; open with correct wiring = replace the gas control. (Power direct vent manual, p. 57)
-
The air pressure switch does not close after the blower starts, so the control cannot prove the vent is clear.Three Flash, three second pause
The air pressure switch does not close after the blower starts, so the control cannot prove the vent is clear. (Power vent manual, p. 55)
By model: On the flue-damper family, Three Flash means 'End Switch Failed Open'.
Likely causes
- Blower not running, sensing tubes off/kinked, vent temperature limit switch open, N.C. pressure switch open, vent pipes too long/too many elbows, obstructions or restriction in the exhaust or intake pipe. (Power direct vent manual, p. 57)
- Air pressure switch not closing due to insufficient draft: blocked vent piping, piping too long, clogged/dirty blower; torn or blocked pressure switch hose. (Power vent manual, p. 54)
What you can check
- Look at the exhaust and air intake pipe ends outside for blockage (the manual lists obstructions in these pipes as a cause). (Power direct vent manual, p. 57)
- Reset the control: slide the ON/OFF switch to OFF, wait 10 seconds, then back to ON. (Power vent manual, p. 54)
For a technician
- Check for 120 VAC to the blower at the start of a heating cycle (no voltage = replace the gas control); if powered but not running, check the capacitor (3 uF +/-5%) and replace the blower; check sensing tubes, vent temperature limit and N.C. pressure switch continuity; verify vent pipe size/length; check blower vacuum with a manometer against the switch setting; replace the switch or control as indicated. (Power direct vent manual, p. 57)
-
The water got too hot and the over-temperature safety (ECO) in the gas control shut the burner off.Four Flash, three second pause
The water got too hot and the over-temperature safety (ECO) in the gas control shut the burner off. (Power vent manual, p. 55)
By model: The 40/50-gal power vent manual (100366731 p. 54-55) says replace the gas control after a confirmed 4-flash; the PDV and PV-ULN corrective-action tables (100366639 p. 57, 100362953 p. 33) describe the knob reset with the 2-reset limit.
Likely causes
- The ECO in the gas control shuts the heater off if the water temperature is too high. (Power vent manual, p. 54)
What you can check
- Turn the main gas supply OFF and have the water heater repaired by a qualified service technician. (Power vent manual, p. 54)
For a technician
- Restart and verify 4 flashes; if seen, switch OFF, main gas OFF, replace the gas control valve/thermostat. (Power vent manual, p. 55)
- ECO manual reset: turn the set-point knob to its lowest position for at least 10 seconds, then back. Only allowed 2 times; the third trip causes hard lockout and the gas control must be replaced. (Power direct vent manual, p. 57)
- 75-gallon power vent: same ECO reset and 2-reset limit. (Power vent 75-gal manual, p. 54)
-
A flame was sensed when the control did not expect one.Five Flash, three second pause
A flame was sensed when the control did not expect one. (Power vent manual, p. 55)
What you can check
- Turn the power OFF for 10-20 seconds, then ON again to clear the fault code. (Power direct vent manual, p. 58)
For a technician
- Reposition the flame rod in the flame and clean it with fine steel wool; replace the control if the code persists. (Power direct vent manual, p. 57)
-
The heater tried to light and failed too many times.Six-One Flash, three second pause
The heater tried to light and failed too many times. It is in a 20-minute soft lockout. (Power vent manual, p. 55)
Likely causes
- Gas supply turned off or gas pressure too low; low supply voltage; flame sensor dirty or not touching the flame; igniter mispositioned or cracked; vent pipes too long. (Power direct vent manual, p. 58)
What you can check
- Make sure the gas supply to the heater is turned on (manual: gas supply turned off is a cause). (Power direct vent manual, p. 58)
- Reset the control: slide the ON/OFF switch to OFF, wait 10 seconds, then back to ON. (Power vent manual, p. 54)
For a technician
- Check supply and manifold gas pressure (manifold is non-adjustable; off by more than 0.3 in. WC with good supply = replace the control); check 115-125 VAC supply; clean/position flame sensor; check igniter position, cracks and resistance (42-76 ohms at the plug); verify vent sizing. (Power direct vent manual, p. 58)
-
Soft lockout: the pressure switch or the high-limit switch kept opening during heating.Six-Two Flash, three second pause
Soft lockout: the pressure switch or the high-limit switch kept opening during heating. (Power vent manual, p. 55)
By model: On the flue-damper family Six-Two means a damper end-switch fault.
Likely causes
- Blower not running; sensing tubes off or kinked; vent temperature limit or N.C. pressure switch open; vent pipes too long; obstruction in the exhaust or intake. (Power direct vent manual, p. 58)
What you can check
- Look at the exhaust and air intake pipe ends outside for blockage (the manual lists obstructions in these pipes as a cause). (Power direct vent manual, p. 57)
- Reset the control: slide the ON/OFF switch to OFF, wait 10 seconds, then back to ON. (Power vent manual, p. 54)
For a technician
- Same checks as Three Flash: blower voltage and capacitor, sensing tubes, limit and pressure-switch continuity, vent sizing, manometer test of blower vacuum; replace the failed part or control. (Power direct vent manual, p. 58)
- ULN power vent: also check continuity of the High Limit switch (N.C.). (Power vent ULN guide, p. 34)
-
Soft lockout: the flame kept going out.Six-Three Flash, three second pause
Soft lockout: the flame kept going out. (Power vent manual, p. 55)
Likely causes
- Gas turned off or pressure too low; low supply voltage; flame sensor dirty or not in the flame; igniter mispositioned; vent pipes too long. (Power direct vent manual, p. 58)
What you can check
- Make sure the gas supply to the heater is turned on. (Power direct vent manual, p. 58)
- Reset the control: slide the ON/OFF switch to OFF, wait 10 seconds, then back to ON. (Power vent manual, p. 54)
For a technician
- Gas pressure, voltage, flame sensor, igniter and vent checks as listed for Six-One. (Power direct vent manual, p. 58)
- ULN power vent: make sure the vent termination restrictor/fitting is installed and correct for the vent table. (Power vent ULN guide, p. 34)
-
Soft lockout: a flame was still sensed after the burner should have been off.Six-Four Flash, three second pause
Soft lockout: a flame was still sensed after the burner should have been off. (Power vent manual, p. 55)
What you can check
- Turn the power OFF for 10-20 seconds, then ON again to clear the fault code. (Power direct vent manual, p. 58)
For a technician
- Replace the control if the fault code persists. (Power direct vent manual, p. 58)
-
Power vent models: the flammable vapor sensor detected vapors or chemicals near the heater and locked it out.Seven Flash, three second pause
Power vent models: the flammable vapor sensor detected vapors or chemicals near the heater and locked it out. (Power vent manual, p. 55)
By model: Power direct vent models (GPDL/GPDT/GPDX, GPDN) list Seven Flash and Eight-One as 'N/A (Flammable Vapour Sensor Lockout/Fault)' with the action 'If this happens replace the gas control' (100366639 p. 56, 58). On the atmospheric status-light family, 7 flashes means gas control failure.
Likely causes
- Sources of chemical contamination: flammable vapors including gas vapors, solvents, paint and thinners, and also water and detergents. (Power vent manual, p. 14)
- ULN power vent: flammable vapors or other chemicals (including litter boxes that release ammonia) near the heater activated the sensor. (Power vent ULN guide, p. 34)
What you can check
- Check around the heater for flammable vapors, solvents, paints, thinners, water or detergents and remove them. (Power vent manual, p. 14)
- Reset the heater; it resets the FVIR circuit if all contamination is gone and the sensor clears. (Power vent manual, p. 14)
For a technician
- If all contamination is removed and the system will not reset, replace the flammable vapor sensor, then reset the control. (Power vent manual, p. 14)
-
The flammable vapor sensor circuit is broken, bypassed or damaged.Eight-One Flash, three second pause
The flammable vapor sensor circuit is broken, bypassed or damaged. (Power vent manual, p. 55)
By model: On power direct vent models this code is listed as N/A; the action is to replace the gas control (100366639 p. 56, 58).
Likely causes
- The signal to/from the FVS has been interrupted, or the FVS has been jumped/bypassed; water exposure damages the sensor. (Power vent ULN guide, p. 34)
For a technician
- If the FVS has not been wet or damaged, secure its connections; if the fault continues, replace the FVS and reset the control. (Power vent ULN guide, p. 34)
-
The temperature sensor fault was detected by the gas control.Eight-Two Flash, three second pause
The temperature sensor fault was detected by the gas control. (Power vent manual, p. 55)
What you can check
- Turn the power OFF for 10-20 seconds, then ON again to clear the fault code. (Power direct vent manual, p. 58)
For a technician
- Replace the control if the fault code persists. (Power direct vent manual, p. 58)
-
The gas control’s electronics found an internal fault.Eight-Three Flash, three second pause
The gas control’s electronics found an internal fault. (Power vent manual, p. 55)
What you can check
- Turn the power OFF for 10-20 seconds, then ON again to clear the fault code. (Power direct vent manual, p. 58)
For a technician
- Replace the control if the fault code persists. (Power direct vent manual, p. 58)
-
The gas valve part of the control has a fault.Eight-Four Flash, three second pause
The gas valve part of the control has a fault. (Power vent manual, p. 55)
What you can check
- Turn the power OFF for 10-20 seconds, then ON again to clear the fault code. (Power direct vent manual, p. 58)
For a technician
- Replace the control if the fault code persists. (Power direct vent manual, p. 58)
- Ultra-Low NOx power direct vent: same action. (Power direct vent ULN manual, p. 56)
-
The control has failed (hard lockout).LED continuously “ON” - Hard Lockout
The control has failed (hard lockout). (Power direct vent manual, p. 58)
By model: PDV tables (100366639 p. 56) show it as 'LED continuously ON'; power vent tables list it as 'Hardware Fault Lockout - Indefinite' (100366731 p. 55).
Likely causes
- Hard lockout occurs when the main controller fails and must be replaced. (Power vent manual, p. 54)
What you can check
- Reset the control: slide the ON/OFF switch to OFF, wait 10 seconds, then back to ON. (Power vent manual, p. 54)
For a technician
- If resetting does not clear it, replace the control. (Power direct vent manual, p. 58)
- 75-gallon power direct vent (GPDX-75L): same action. (Power direct vent 75-gal manual, p. 54)
Vertex condensing gas tanks
Vertex GPHE (a row of lights), Vertex 100 GDHE and Ultra Low NOx HDHE (a message on the screen), and Vertex HV (an E code).
-
The heater is not properly grounded.LED Status 1
The heater is not properly grounded. (Vertex GPHE manual, p. 35)
By model: LED pattern (positions 1-6, left to right; 'on' = filled in the chart, read from the chart picture): on, off, off, on, off, on.
For a technician
- Make sure the wall outlet is properly grounded and all ground wires on the heater are secure. (Vertex GPHE manual, p. 35)
-
Poor ground or the hot and neutral wires are reversed.LED Status 2
Poor ground or the hot and neutral wires are reversed. (Vertex GPHE manual, p. 35)
By model: LED pattern (positions 1-6, left to right; 'on' = filled in the chart, read from the chart picture): on, off, on, off, on, off.
For a technician
- Check the ground connection and the outlet/power wiring; 120 VAC hot must go to the on/off switch. (Vertex GPHE manual, p. 35)
-
The air pressure switch reads closed before it should.LED Status 3
The air pressure switch reads closed before it should. The blower may not start. (Vertex GPHE manual, p. 35)
By model: LED pattern (positions 1-6, left to right; 'on' = filled in the chart, read from the chart picture): on, off, on, off, off, off.
For a technician
- Make sure the pressure switch wiring is correct and the switch is not jumpered; replace the air pressure switch. (Vertex GPHE manual, p. 35)
-
The air pressure switch never closes after the blower starts.LED Status 4
The air pressure switch never closes after the blower starts. The blower may run nonstop. (Vertex GPHE manual, p. 35)
By model: LED pattern (positions 1-6, left to right; 'on' = filled in the chart, read from the chart picture): on, off, on, off, off, on.
What you can check
- Check the vent and intake pipe ends for obstructions and make sure the condensate trap and drain are not blocked. (Vertex GPHE manual, p. 35)
For a technician
- Check the pressure switch sensing tube; verify vent/intake pipe size, length and elbow count against the manual. (Vertex GPHE manual, p. 35)
-
The hot surface igniter circuit is open.LED Status 5
The hot surface igniter circuit is open. (Vertex GPHE manual, p. 35)
By model: LED pattern (positions 1-6, left to right; 'on' = filled in the chart, read from the chart picture): on, off, on, off, on, on.
For a technician
- Check igniter wiring; igniter resistance should be 11-18 ohms at room temperature; check the igniter plug and the gas control socket; replace igniter or gas control as indicated. (Vertex GPHE manual, p. 35)
-
The heater failed to light 3 times and is locked out for one hour.LED Status 6
The heater failed to light 3 times and is locked out for one hour. (Vertex GPHE manual, p. 36)
By model: LED pattern (positions 1-6, left to right; 'on' = filled in the chart, read from the chart picture): on, off, off, on, on, off.
Likely causes
- The gas control reached its maximum of 3 ignition retries and is locked out for one hour. (Vertex GPHE manual, p. 36)
- Gas supply turned off or pressure too low. (Vertex GPHE manual, p. 36)
What you can check
- Make sure the gas supply is on (for low gas pressure, consult your gas utility). (Vertex GPHE manual, p. 36)
- Cycle the power to the water heater off and on to reset. (Vertex GPHE manual, p. 36)
For a technician
- Check flame sensor contact and steady flame; check supply and manifold gas pressure; clean the flame sensor with fine steel wool; check igniter plug/socket; replace the igniter assembly. (Vertex GPHE manual, p. 36)
-
The gas control’s self-test found an internal electronics problem.LED Status 7, 8, 9
The gas control’s self-test found an internal electronics problem. (Vertex GPHE manual, p. 36)
By model: LED pattern (positions 1-6, left to right; 'on' = filled in the chart, read from the chart picture): 7 = on, off, off, off, on, on; 8 = on, off, on, on, on, off; 9 = all six on.
What you can check
- Turn the power off for 10-20 seconds, then on again to clear the code. (Vertex GPHE manual, p. 36)
For a technician
- If the code persists or cannot be cleared, replace the gas control valve/thermostat. (Vertex GPHE manual, p. 36)
-
A flame was sensed when there should not be one.LED Status 10
A flame was sensed when there should not be one. (Vertex GPHE manual, p. 36)
By model: LED pattern (positions 1-6, left to right; 'on' = filled in the chart, read from the chart picture): on, off, off, off, on, off.
What you can check
- Turn the power off for 10-20 seconds, then on again to clear the code. (Vertex GPHE manual, p. 36)
For a technician
- Replace the gas control valve/thermostat if the code persists. (Vertex GPHE manual, p. 36)
-
The water got too hot and the high-limit (ECO) shut off the burner.LED Status 11
The water got too hot and the high-limit (ECO) shut off the burner. (Vertex GPHE manual, p. 36)
By model: LED pattern (positions 1-6, left to right; 'on' = filled in the chart, read from the chart picture): on, off, off, off, on, on (the label row under this pattern reads '▲ B C D E F'). It prints the same as pattern 7 (self-test fault) in this manual revision.
Likely causes
- The high limit interrupts burner gas if the water reaches 195°F (91°C). (Vertex GPHE manual, p. 32)
What you can check
- After the tank cools below 140°F (60°C), turn the heater off for at least 10 seconds with the switch on top, then on. If that fails, call your plumber or service representative. (Vertex GPHE manual, p. 32)
For a technician
- Replace the gas control valve/thermostat if the code persists. (Vertex GPHE manual, p. 36)
-
A temperature button on the control is stuck.LED Status 12
A temperature button on the control is stuck. (Vertex GPHE manual, p. 36)
By model: LED pattern (positions 1-6, left to right; 'on' = filled in the chart, read from the chart picture): on, off, on, on, off, off.
What you can check
- Press and release both temperature adjust buttons several times, then cycle the heater’s power off and on. (Vertex GPHE manual, p. 36)
For a technician
- Replace the gas control valve/thermostat if the code persists. (Vertex GPHE manual, p. 36)
-
The water temperature sensor is open or shorted.LED Status 13
The water temperature sensor is open or shorted. (Vertex GPHE manual, p. 36)
By model: LED pattern (positions 1-6, left to right; 'on' = filled in the chart, read from the chart picture): on, off, on, on, off, on. In this manual revision patterns 13 and 14 are printed identically; tell them apart by symptom or call A. O. Smith.
What you can check
- Turn the power off for 10-20 seconds, then on again to clear the code. (Vertex GPHE manual, p. 36)
For a technician
- Replace the temperature probe if the code persists. (Vertex GPHE manual, p. 36)
-
The flame sensor reads a weak flame.LED Status 14
The flame sensor reads a weak flame. (Vertex GPHE manual, p. 36)
By model: LED pattern (positions 1-6, left to right; 'on' = filled in the chart, read from the chart picture): on, off, on, on, off, on (prints the same as pattern 13 in this manual).
For a technician
- Check for low supply voltage; make sure the flame sensor touches a steady flame; clean the flame sensor with ultra-fine steel wool or a Scotch-Brite pad. (Vertex GPHE manual, p. 36)
-
The heater tried to light three times and never saw a flame, so it locked out.Ignition Failure (series 300/301 also shows Error Code: B2-70)
The heater tried to light three times and never saw a flame, so it locked out. (Vertex 100 manual (series 130), p. 56)
By model: Series 300/301 screen shows 'Error Code: B2-70' (100313413 p. 60).
Likely causes
- Less than 1.0 microamp of flame signal during the ignition check on three consecutive tries. (Vertex service handbook, p. 65 (PDF p. 67))
- Not properly grounded; dirty or corroded flame sensor; loose wiring to the flame sensor or gas valve; restricted or wrongly installed intake/vent piping; low or no gas pressure. (Vertex 100 manual (series 130), p. 56)
- Burner lights briefly but won’t stay lit: wrong manifold pressure, undersized gas line, low gas pressure, clogged intake screen or burner. (Vertex 100 manual (series 300), p. 59)
What you can check
- Make sure the main gas shutoff valve is open. (Vertex service handbook, p. 65 (PDF p. 67))
For a technician
- With a manometer, confirm supply gas pressure is above the data-plate minimum and does not drop more than 1.5 in. WC when firing; clean/tighten gas valve, flame sensor and igniter wiring; clean or replace the flame sensor; realign the igniter gap; confirm grounding. (Vertex 100 manual (series 300), p. 60)
- Check gas orifice size (0.191 in. natural gas, 0.162 in. propane) and remove the blower/burner assembly to inspect the burner, flame sensor (about 1/2 in. gap) and igniter. (Vertex service handbook, p. 65 (PDF p. 67))
-
The exhaust pressure switch opened.Blocked Exhaust (series 300/301: Error Code: A8-1201)
The exhaust pressure switch opened. The vent pipe is blocked or restricted, often by condensate water that can’t drain. (Vertex 100 manual (series 130), p. 56)
By model: Older Vertex 100 models called this switch 'Blocked Outlet Switch' in places.
Likely causes
- Condensate drain blocked so the exhaust elbow fills with water; vent piping restricted or condensate trapped in a low point; too many feet or elbows or wrong pipe size; strong wind pressurizing the vent. (Vertex 100 manual (series 130), p. 56)
What you can check
- Check that the condensate drain hose is draining and not blocked. (Vertex 100 manual (series 130), p. 56)
- Look at the outside exhaust termination for blockage. (Vertex 100 manual (series 300), p. 60)
For a technician
- If the fault occurs before the blower runs, check pressure switch connections and continuity (switch should be closed); replace if open. Check vent size/length and low points. (Vertex 100 manual (series 300), p. 60)
-
The intake-air pressure switch opened.Blocked Air Intake (series 300/301: Error Code: A7-1201)
The intake-air pressure switch opened. The air intake is blocked or restricted. (Vertex 100 manual (series 130), p. 57)
Likely causes
- Loose wiring to the switch; intake piping too long, too many elbows or wrong size; excessive negative air pressure in the room; high winds. (Vertex 100 manual (series 130), p. 57)
What you can check
- Look at the outside intake termination for blockage. (Vertex 100 manual (series 300), p. 61)
For a technician
- Conventional-vent installs: clear debris from the screen inside the intake air connection. Direct-vent installs: check intake size/length/elbows and low points that trap water; make sure the intake screen was removed during installation; test the switch. (Vertex service handbook, p. 61 (PDF p. 63))
-
The tank water got dangerously hot and the high-limit safety shut the heater off.Energy Cut Out (ECO) (series 120/121, 130/131); High Temp Limit Exceeded, Error Code: A5-401 (series 300/301)
The tank water got dangerously hot and the high-limit safety shut the heater off. (Vertex service handbook, p. 60 (PDF p. 62))
By model: The tank must cool to 140°F (60°C) before the lockout can be reset (series 120/121 handbook). Name and threshold wording differ by series.
Likely causes
- The ECO switch (inside the temperature probe, two red wires) opened, or its wiring is loose or open. (Vertex 100 manual (series 130), p. 57)
What you can check
- Carefully check the water temperature at a nearby hot water fixture. If above 180°F, shut off power and gas to the heater and call technical support. Do not leave it running. (Vertex service handbook, p. 60 (PDF p. 62))
For a technician
- If below 180°F, cycle power to reset and watch several heating cycles; if the tank climbs more than 5°F above set point, shut off power and gas and call support. Check probe wiring and perform the ECO continuity test; replace the probe if open with normal tank temperature. (Vertex service handbook, p. 60 (PDF p. 62))
- Series 300/301: if the two red probe wires are open and water is below 160°F, replace the temperature probe; if water exceeds 195°F, turn off power and gas and call tech support. (Vertex 100 manual (series 300), p. 61)
-
The powered anode does not sense water in the tank.No Water (Error Code: D6-8)
The powered anode does not sense water in the tank. (Vertex 100 manual (series 300), p. 61)
By model: Only models with a powered (non-sacrificial) anode.
What you can check
- Confirm the water heater is full of water. (Vertex 100 manual (series 300), p. 61)
For a technician
- Check powered anode wiring for tightness and debris/moisture, confirm electrical ground, inspect/clean/replace the powered anode. (Vertex 100 manual (series 300), p. 61)
-
The powered anode rod is shorting to the tank or ground.Anode Shorted (Error Code: CC-B)
The powered anode rod is shorting to the tank or ground. (Vertex 100 manual (series 300), p. 61)
By model: Only models with a powered anode.
For a technician
- Check the anode is not bent or touching the tank, remove contamination between the anode top and surrounding metal (solder, Loctite, WD40), confirm ground, inspect/replace the powered anode. (Vertex 100 manual (series 300), p. 61)
-
The lower tank temperature probe circuit is open or shorted.Lower Temp Probe Open (Error Code: 48-0)
The lower tank temperature probe circuit is open or shorted. (Vertex 100 manual (series 300), p. 62)
By model: Series 300/301 manual.
For a technician
- Confirm the lower probe cable is plugged into the CCB and probe; measure probe resistance; inspect the cable; replace the probe as needed. (Vertex 100 manual (series 300), p. 62)
-
The hot and neutral wires feeding the heater are reversed.AC Reversed
The hot and neutral wires feeding the heater are reversed. (Vertex service handbook, p. 58 (PDF p. 60))
By model: Series 120/121 service handbook.
For a technician
- Check the outlet (or junction-box wiring) for correct polarity and ground; hot to the heater’s black wire, neutral to white; check 120 VAC at CCB J3. (Vertex service handbook, p. 58 (PDF p. 60))
-
The tank temperature probe reads as an open circuit.Temp Probe Open
The tank temperature probe reads as an open circuit. (Vertex service handbook, p. 58 (PDF p. 60))
For a technician
- Check probe plug/socket at CCB J7 and wiring; perform the temperature sensor test; replace the probe if above 56,000 ohms. (Vertex service handbook, p. 58 (PDF p. 60))
-
The tank temperature probe reads as a short circuit.Temp Probe Short
The tank temperature probe reads as a short circuit. (Vertex service handbook, p. 58 (PDF p. 60))
For a technician
- Check wiring between probe and CCB J7 for pinches/shorts; perform the temperature sensor test; replace the probe if below 390 ohms. (Vertex service handbook, p. 58 (PDF p. 60))
-
The flame sensor circuit is shorted to ground.Flame Sensor Short
The flame sensor circuit is shorted to ground. (Vertex service handbook, p. 59 (PDF p. 61))
For a technician
- Check wiring from CCB J4 to the burner adapter harness; remove the blower and burner assembly to inspect the flame sensor (1/2 in. gap to burner, not touching it); replace damaged parts. (Vertex service handbook, p. 59 (PDF p. 61))
-
The control sees a flame when the burner should be off.Flame Detect Error
The control sees a flame when the burner should be off. (Vertex service handbook, p. 59 (PDF p. 61))
For a technician
- Check the 24 V gas valve closes fully; look through the burner sight glass for flame after the cycle ends; if the flame keeps burning, replace the gas valve. (Vertex service handbook, p. 59 (PDF p. 61))
-
The blower-prover pressure switch reads closed before the blower has started.Blower Prover Failure
The blower-prover pressure switch reads closed before the blower has started. (Vertex 100 manual (series 130), p. 57)
Likely causes
- Pinched/shorted switch wiring; a jumper wire on the switch; strong wind pressurizing the vent; excessive negative air pressure in the room. (Vertex 100 manual (series 130), p. 57)
For a technician
- Check wiring at CCB J6 pins 6 & 7, remove any jumpers, perform the pressure switch tests and replace the switch if defective. (Vertex service handbook, p. 62 (PDF p. 64))
-
After the blower is turned on, its pressure switch never closes.Blower Prover Open
After the blower is turned on, its pressure switch never closes. The blower may not be running, or its sensing tube is off or blocked. (Vertex 100 manual (series 130), p. 57)
Likely causes
- Loose wiring to the switch; sensing tube disconnected, kinked, filled with condensate or leaking; blower not running or its wiring loose. (Vertex 100 manual (series 130), p. 57)
For a technician
- With a call for heat, check 120 VAC at CCB J2 and the blower plugs, check the sensing tube and switch wiring, replace the switch if defective. (Vertex service handbook, p. 63 (PDF p. 65))
-
The hot surface igniter is drawing too little current to light the burner.Low Igniter Current
The hot surface igniter is drawing too little current to light the burner. (Vertex service handbook, p. 64 (PDF p. 66))
For a technician
- Check igniter wiring and connections at CCB J5; with power off check igniter continuity (open or 200+ ohms = replace); with a call for heat check igniter current (replace if under 0.55 A). (Vertex service handbook, p. 64 (PDF p. 66))
-
The display (UIM) and the main control board (CCB) are not talking.Communication Failure
The display (UIM) and the main control board (CCB) are not talking. (Vertex service handbook, p. 66 (PDF p. 68))
For a technician
- Turn off power, check the communication cable between UIM J2 and CCB J16, replace the cable (standard Cat 5 network cable). (Vertex service handbook, p. 66 (PDF p. 68))
-
Alert only: the powered anode shows no voltage.Alert: No Anode Voltage
Alert only: the powered anode shows no voltage. The heater keeps running but needs service soon. (Vertex 100 manual (series 130), p. 57)
By model: Series 130/131; applies to models with the powered anode option.
Likely causes
- No water in the tank; loose or open anode wiring; anode wiring shorted to ground; heater not properly grounded. (Vertex 100 manual (series 130), p. 57)
What you can check
- Make sure the tank is full of water. (Vertex 100 manual (series 130), p. 57)
For a technician
- Check powered anode wiring and grounding. (Vertex 100 manual (series 130), p. 57)
-
The display is blank.UIM (LCD) Is Blank
The display is blank. The heater may or may not be running. (Vertex service handbook, p. 57 (PDF p. 59))
Likely causes
- On/off switch off; heater not plugged in; tripped breaker or blown fuse; 120 VAC or 24 VAC supply problem; bad transformer; wiring/plug problems; bad UIM cable. (Vertex service handbook, p. 57 (PDF p. 59))
What you can check
- Make sure the heater’s on/off switch is on, the breaker is on, and the heater is plugged in. (Vertex service handbook, p. 57 (PDF p. 59))
For a technician
- Check 120 VAC at the outlet/junction box and CCB, 24 VAC from the transformer, and the UIM communication cable; replace failed parts. (Vertex service handbook, p. 57 (PDF p. 59))
-
The tank got too hot and the high-limit safety shut the heater down.High Temp Limit Exceeded
The tank got too hot and the high-limit safety shut the heater down. (Vertex ULN HDHE manual, p. 65)
By model: Data error codes (3,30)-(3,1018) refer to NTC sensor shorts/opens/drift.
What you can check
- Use a thermometer at a hot water fixture to check the real water temperature. If it is below 180°F, reset the water heater. (Vertex ULN HDHE manual, p. 65)
For a technician
- If the problem continues, contact A. O. Smith technical support or follow the service handbook. (Vertex ULN HDHE manual, p. 65)
-
The main tank temperature probe is open, shorted or reading wrong.Main Temperature Probe Failure
The main tank temperature probe is open, shorted or reading wrong. (Vertex ULN HDHE manual, p. 65)
By model: Fault 212 is also named 'Main Temperature Probe Failure' (detected by the combustion safety control).
For a technician
- Make sure the main temp probe connections are clean and secure and its harness is undamaged. (Vertex ULN HDHE manual, p. 65)
- If the problem continues, contact A. O. Smith technical support or follow the service handbook. (Vertex ULN HDHE manual, p. 65)
-
The main control board found an internal software problem.Software Failure
The main control board found an internal software problem. (Vertex ULN HDHE manual, p. 65)
What you can check
- Cycle main power: turn off the breaker/disconnect, wait about 30 seconds, turn it back on. (Vertex ULN HDHE manual, p. 65)
For a technician
- If the problem continues, contact A. O. Smith technical support or follow the service handbook. (Vertex ULN HDHE manual, p. 65)
-
The main control board found an internal hardware problem.Hardware Failure
The main control board found an internal hardware problem. (Vertex ULN HDHE manual, p. 65)
What you can check
- Cycle main power: turn off the breaker/disconnect, wait about 30 seconds, turn it back on. (Vertex ULN HDHE manual, p. 65)
For a technician
- If the problem continues, contact A. O. Smith technical support or follow the service handbook. (Vertex ULN HDHE manual, p. 65)
-
The control sees a problem with the power coming in (screen says Voltage Too Low).Power Supply Fault (screen: Voltage Too Low)
The control sees a problem with the power coming in (screen says Voltage Too Low). (Vertex ULN HDHE manual, p. 66)
What you can check
- Cycle main power: turn off the breaker/disconnect, wait about 30 seconds, turn it back on. (Vertex ULN HDHE manual, p. 66)
For a technician
- If the problem continues, contact A. O. Smith technical support or follow the service handbook. (Vertex ULN HDHE manual, p. 66)
-
The display and the main control board are not talking.Communication Failure
The display and the main control board are not talking. (Vertex ULN HDHE manual, p. 66)
What you can check
- Cycle main power: turn off the breaker/disconnect, wait about 30 seconds, turn it back on. (Vertex ULN HDHE manual, p. 66)
For a technician
- Inspect the communication cable between the UIM and TRC for damage and secure connections. (Vertex ULN HDHE manual, p. 66)
- If the problem continues, contact A. O. Smith technical support or follow the service handbook. (Vertex ULN HDHE manual, p. 66)
-
The exhaust (flue gas) temperature probe is open or shorted.Flue Gas Temperature Probe Failure
The exhaust (flue gas) temperature probe is open or shorted. (Vertex ULN HDHE manual, p. 66)
What you can check
- Cycle main power: turn off the breaker/disconnect, wait about 30 seconds, turn it back on. (Vertex ULN HDHE manual, p. 66)
For a technician
- If the problem continues, contact technical support. (Vertex ULN HDHE manual, p. 66)
-
The leak sensor is wet.Water Leak Detected
The leak sensor is wet. There may be a leak near the heater. (Vertex ULN HDHE manual, p. 66)
What you can check
- Look around the heater for moisture: threaded fittings, the exhaust elbow connection and the cleanout cover. (Vertex ULN HDHE manual, p. 66)
For a technician
- Use litmus (pH) strips to tell whether the water is acidic exhaust condensate or tank water; contact technical support if it continues. (Vertex ULN HDHE manual, p. 66)
-
The leak sensor is unplugged or not detected.Leak Sensor Disconnected
The leak sensor is unplugged or not detected. (Vertex ULN HDHE manual, p. 67)
What you can check
- Make sure the leak detector is securely connected to the water heater. (Vertex ULN HDHE manual, p. 67)
For a technician
- Check the leak detector harness at TRC terminal J6 pins 1 and 11. (Vertex ULN HDHE manual, p. 67)
-
The powered anode is shorting to the tank or ground.Anode Shorted
The powered anode is shorting to the tank or ground. (Vertex ULN HDHE manual, p. 67)
By model: Fault 219 is also 'Anode Shorted' (external powered anode circuit).
For a technician
- Inspect the anode wire connection for corrosion, moisture or contamination; secure both ends; check the harness. (Vertex ULN HDHE manual, p. 67)
-
The powered anode does not sense water in the tank.No Water
The powered anode does not sense water in the tank. (Vertex ULN HDHE manual, p. 67)
What you can check
- Make sure the tank is full of water, following the 'Fill the Tank' instructions. (Vertex ULN HDHE manual, p. 67)
For a technician
- Inspect and secure the anode wire connections and harness. (Vertex ULN HDHE manual, p. 67)
-
The flame sensor signal is weak.Weak Flame Signal
The flame sensor signal is weak. (Vertex ULN HDHE manual, p. 67)
For a technician
- Check the flame sensor harness and connections; remove the flame sensor, inspect the ceramic, clean the rod with steel wool. (Vertex ULN HDHE manual, p. 67)
-
The flame sensor sees a flame when the gas should be off.Flame Sensor Error (screen: Flame Sensor Sensing Error)
The flame sensor sees a flame when the gas should be off. Shut off the gas until it is repaired. (Vertex ULN HDHE manual, p. 68)
What you can check
- Shut off the gas to the heater until it is repaired (the fault screen says so). (Vertex ULN HDHE manual, p. 68)
For a technician
- Check the flame sensor harness and connections; remove and inspect the flame sensor; clean the rod with steel wool. (Vertex ULN HDHE manual, p. 68)
-
The heater tried to light but never saw a flame.Ignition Failure
The heater tried to light but never saw a flame. (Vertex ULN HDHE manual, p. 68)
By model: The manual lists Resideo data codes 129, 147, 241 for this fault.
For a technician
- Verify the gas supply, venting and intake air pipes are installed per the instruction manual; screen also says clean the flame-sense rod and check gas-supply pressure. (Vertex ULN HDHE manual, p. 68)
- If the problem continues, contact A. O. Smith technical support or follow the service handbook. (Vertex ULN HDHE manual, p. 68)
-
Warning: the tank is above 190°F.High Temperature Warning (screen: Temp High Limit)
Warning: the tank is above 190°F. It clears when the tank drops below 180°F. (Vertex ULN HDHE manual, p. 68)
What you can check
- Reset by switching the Enable/Disable switch to disable and back to enable. (Vertex ULN HDHE manual, p. 68)
- If it continues, check the water temperature at a hot water fixture with a thermometer. (Vertex ULN HDHE manual, p. 68)
For a technician
- If the problem continues, contact A. O. Smith technical support or follow the service handbook. (Vertex ULN HDHE manual, p. 68)
-
The control’s clock is not set.Clock Not Set
The control’s clock is not set. (Vertex ULN HDHE manual, p. 69)
What you can check
- Set the clock using the instructions in the installation manual; if equipped, reconnect iComm for automatic updates. (Vertex ULN HDHE manual, p. 69)
-
The intake-air pressure switch says the air intake is blocked or restricted.Blocked Air Intake
The intake-air pressure switch says the air intake is blocked or restricted. (Vertex ULN HDHE manual, p. 69)
What you can check
- Check the outside intake termination for blockage. (Vertex ULN HDHE manual, p. 69)
For a technician
- Check intake piping per the manual and slope of horizontal runs; inspect the pipe from blower to termination; check the sensing tube and switch wiring. (Vertex ULN HDHE manual, p. 69)
-
The exhaust pressure switch says the vent is blocked or restricted.Blocked Exhaust
The exhaust pressure switch says the vent is blocked or restricted. (Vertex ULN HDHE manual, p. 70)
What you can check
- Check the outside exhaust termination for blockage. (Vertex ULN HDHE manual, p. 70)
For a technician
- Check exhaust piping and slope; inspect from heater to termination; check the sensing tube and switch wiring. (Vertex ULN HDHE manual, p. 70)
-
The control board software is older than what the configuration key expects.Software and FMM Incompatible
The control board software is older than what the configuration key expects. (Vertex ULN HDHE manual, p. 70)
For a technician
- Contact technical support. (Vertex ULN HDHE manual, p. 70)
-
The powered-anode module is not communicating.CPAM Disconnected
The powered-anode module is not communicating. (Vertex ULN HDHE manual, p. 70)
For a technician
- Make sure the CPAM is powered and its wiring is secure and undamaged. (Vertex ULN HDHE manual, p. 70)
-
The combustion safety control is not communicating with the main board.CSC Disconnected
The combustion safety control is not communicating with the main board. (Vertex ULN HDHE manual, p. 71)
For a technician
- Secure the communication cable between TRC J4 and CSC X10. (Vertex ULN HDHE manual, p. 71)
-
The water valve module is not communicating.Water Valve Module Disconnected
The water valve module is not communicating. (Vertex ULN HDHE manual, p. 71)
For a technician
- Check the module’s wire connections and harness. (Vertex ULN HDHE manual, p. 71)
-
The automatic self-test finished.Auto Test Complete
The automatic self-test finished. (Vertex ULN HDHE manual, p. 71)
By model: The table row and the screen text disagree slightly (cycle power vs. no action).
What you can check
- The screen says no action is required; the table also says to cycle main power and call technical support if the message continues. (Vertex ULN HDHE manual, p. 71)
-
The blower is not reporting the speed it was told to run.No Blower Speed Feedback
The blower is not reporting the speed it was told to run. (Vertex ULN HDHE manual, p. 71)
For a technician
- Check both blower wire connections and harnesses. (Vertex ULN HDHE manual, p. 71)
-
The main temperature probe is open, shorted, or its two sensors disagree.Main Temperature Probe Failure
The main temperature probe is open, shorted, or its two sensors disagree. (Vertex ULN HDHE manual, p. 72)
For a technician
- Check the probe connections and harness. (Vertex ULN HDHE manual, p. 72)
- If the problem continues, contact A. O. Smith technical support or follow the service handbook. (Vertex ULN HDHE manual, p. 72)
-
The combustion safety control found a hardware fault.Hardware Failure (CSC)
The combustion safety control found a hardware fault. (Vertex ULN HDHE manual, p. 72)
What you can check
- Cycle power to the water heater (the fault screen says so). (Vertex ULN HDHE manual, p. 72)
For a technician
- Check the flame sensor harness and connections; remove and inspect the flame sensor; clean the rod with steel wool. (Vertex ULN HDHE manual, p. 72)
-
The combustion safety control found a software fault.Software Failure (CSC)
The combustion safety control found a software fault. (Vertex ULN HDHE manual, p. 72)
What you can check
- Cycle main power: turn off the breaker/disconnect, wait about 30 seconds, turn it back on. (Vertex ULN HDHE manual, p. 72)
For a technician
- If the problem continues, contact A. O. Smith technical support or follow the service handbook. (Vertex ULN HDHE manual, p. 72)
-
The gas control calibration failed (during first calibration or recalibration).Calibration Error (screen: Gas Control Calibration Error)
The gas control calibration failed (during first calibration or recalibration). (Vertex ULN HDHE manual, p. 72)
What you can check
- Cycle main power: turn off the breaker/disconnect, wait about 30 seconds, turn it back on. (Vertex ULN HDHE manual, p. 72)
For a technician
- If the problem continues, contact A. O. Smith technical support or follow the service handbook. (Vertex ULN HDHE manual, p. 72)
-
The gas valve circuit or its wires have a problem.Gas Valve Circuit Fault
The gas valve circuit or its wires have a problem. (Vertex ULN HDHE manual, p. 73)
For a technician
- Check gas valve wiring at both ends and the harness. (Vertex ULN HDHE manual, p. 73)
- If the problem continues, contact A. O. Smith technical support or follow the service handbook. (Vertex ULN HDHE manual, p. 73)
-
The motor-driven throttle (stepper motor) has a mechanical or electrical fault.MDT Fault
The motor-driven throttle (stepper motor) has a mechanical or electrical fault. (Vertex ULN HDHE manual, p. 73)
For a technician
- Check MDT wiring at both ends and the harness. (Vertex ULN HDHE manual, p. 73)
- If the problem continues, contact A. O. Smith technical support or follow the service handbook. (Vertex ULN HDHE manual, p. 73)
-
The building management (BMS) module is not communicating.BMS Module Disconnected
The building management (BMS) module is not communicating. (Vertex ULN HDHE manual, p. 73)
By model: This manual row prints data code '(209, 2014)' and a 'No Water' screen image under fault 218, which look like copy errors.
For a technician
- Check the module’s wire connections and harness. (Vertex ULN HDHE manual, p. 73)
-
The external powered anode circuit is shorted to the tank or ground.Anode Shorted
The external powered anode circuit is shorted to the tank or ground. (Vertex ULN HDHE manual, p. 73)
Likely causes
- Contamination (solder, Loctite, WD40) between anode top and surrounding metal; sediment bridging to the tank; loose anode wire touching the tank; bent anode. (Vertex ULN HDHE manual, p. 73)
For a technician
- Find and correct the short at the anode. (Vertex ULN HDHE manual, p. 73)
-
The powered-anode module has failed.Powered Anode Module Failure
The powered-anode module has failed. (Vertex ULN HDHE manual, p. 74)
What you can check
- Cycle the main power off and then on. (Vertex ULN HDHE manual, p. 74)
For a technician
- Replace the CPAM. (Vertex ULN HDHE manual, p. 74)
-
The heater was reset too many times in a short period and has locked out.Reset Lockout (data error code 13)
The heater was reset too many times in a short period and has locked out. (Vertex ULN HDHE manual, p. 74)
By model: Fault code 13 is listed with the same name.
What you can check
- Cycle the main power to the water heater once. (Vertex ULN HDHE manual, p. 74)
For a technician
- If the problem continues, contact A. O. Smith technical support or follow the service handbook. (Vertex ULN HDHE manual, p. 74)
-
The configuration key is missing or unplugged.FMM Missing (screen: Missing Configuration Key)
The configuration key is missing or unplugged. The heater cannot run without it. (Vertex ULN HDHE manual, p. 74)
What you can check
- Cycle main power: turn off the breaker/disconnect, wait about 30 seconds, turn it back on. (Vertex ULN HDHE manual, p. 74)
For a technician
- Check connections and the wire at TRC terminal J2. (Vertex ULN HDHE manual, p. 74)
-
The display (UIM) is missing or unplugged.Missing Display
The display (UIM) is missing or unplugged. (Vertex ULN HDHE manual, p. 74)
What you can check
- Cycle main power: turn off the breaker/disconnect, wait about 30 seconds, turn it back on. (Vertex ULN HDHE manual, p. 74)
For a technician
- Check the connection at TRC terminal J2 and the harnesses. (Vertex ULN HDHE manual, p. 74)
-
The main control board’s software or hardware is outdated for this heater.TRC Software or Hardware Is Old
The main control board’s software or hardware is outdated for this heater. (Vertex ULN HDHE manual, p. 75)
For a technician
- Contact technical support. (Vertex ULN HDHE manual, p. 75)
-
The display’s software or hardware is outdated for this heater.Display software or hardware is old.
The display’s software or hardware is outdated for this heater. (Vertex ULN HDHE manual, p. 75)
For a technician
- Contact technical support. (Vertex ULN HDHE manual, p. 75)
-
The powered-anode circuit has failed.Powered Anode Circuit Failure
The powered-anode circuit has failed. (Vertex ULN HDHE manual, p. 75)
For a technician
- Contact technical support. (Vertex ULN HDHE manual, p. 75)
-
The configuration key’s software is outdated.FMM Incompatible
The configuration key’s software is outdated. (Vertex ULN HDHE manual, p. 75)
For a technician
- Contact technical support. (Vertex ULN HDHE manual, p. 75)
-
Your saved settings were corrupted, so the heater went back to factory settings.User Setpoints Error Detected
Your saved settings were corrupted, so the heater went back to factory settings. (Vertex ULN HDHE manual, p. 75)
What you can check
- Switch the Enable/Disable switch to Disable, wait 30 seconds, switch back to Enable, then readjust your settings. (Vertex ULN HDHE manual, p. 75)
-
The tank water got too hot and the high-limit shut the heater off (hard fault, buzzer beeps once per second).ECO (Dhw High-Limit)
The tank water got too hot and the high-limit shut the heater off (hard fault, buzzer beeps once per second). (Vertex HV guide, p. 56)
By model: Two numbers appear in the same manual: 'approximately 190°F' (p. 48) and 'T > Tmax 201°F' (p. 56).
Likely causes
- The ECO activates at abnormally high water temperature (approximately 190°F) and the control locks out. (Vertex HV guide, p. 48)
What you can check
- Wait for the water to drop below 140°F before any reset. (Vertex HV guide, p. 48)
For a technician
- Determine and correct the reason for the ECO trip before resetting. (Vertex HV guide, p. 48)
-
A flame was sensed when the burner should be off (soft fault).Flame out of sequence
A flame was sensed when the burner should be off (soft fault). (Vertex HV guide, p. 56)
Likely causes
- Flame current sensed during pre-purge, warm-up or post-purge; blower runs at high speed until the flame is gone, and normal operation resumes 15 minutes later. (Vertex HV guide, p. 55)
What you can check
- After the cause is fixed, clear it: unlock the control, then hold ON/OFF and Plus together for 3 seconds. (Vertex HV guide, p. 56)
For a technician
- Have a qualified service technician find and correct the cause. (Vertex HV guide, p. 54)
-
The flame went out 3 times in 5 minutes (soft fault).Repeated Flame Loss
The flame went out 3 times in 5 minutes (soft fault). (Vertex HV guide, p. 56)
What you can check
- After the cause is fixed, clear it: unlock the control, then hold ON/OFF and Plus together for 3 seconds. (Vertex HV guide, p. 56)
For a technician
- Have a qualified service technician find and correct the cause. (Vertex HV guide, p. 54)
-
The heater failed to light several times in a row (soft fault).Ignition failure
The heater failed to light several times in a row (soft fault). (Vertex HV guide, p. 56)
What you can check
- After the cause is fixed, clear it: unlock the control, then hold ON/OFF and Plus together for 3 seconds. (Vertex HV guide, p. 56)
For a technician
- Have a qualified service technician find and correct the cause. (Vertex HV guide, p. 54)
-
The vent outlet pressure switch opened a third time within an hour; the vent is blocked (soft fault).Blocked flue
The vent outlet pressure switch opened a third time within an hour; the vent is blocked (soft fault). (Vertex HV guide, p. 56)
Likely causes
- The outlet air pressure switch opens when the outlet vent is partially or totally blocked. (Vertex HV guide, p. 54)
What you can check
- Check the outside exhaust vent termination for blockage. (Vertex HV guide, p. 54)
- After the cause is fixed, clear it: unlock the control, then hold ON/OFF and Plus together for 3 seconds. (Vertex HV guide, p. 56)
For a technician
- Have a qualified service technician find and correct the cause. (Vertex HV guide, p. 54)
-
The vent outlet pressure switch opened (first or second time).Blocked flue
The vent outlet pressure switch opened (first or second time). It resets after post-purge. (Vertex HV guide, p. 56)
Likely causes
- The outlet air pressure switch opens when the outlet vent is partially or totally blocked. (Vertex HV guide, p. 54)
What you can check
- Check the outside exhaust vent termination for blockage. (Vertex HV guide, p. 54)
-
The tank temperature probe is open, shorted, or its two sensors disagree.Tank Temperature Probe (NTC) failure
The tank temperature probe is open, shorted, or its two sensors disagree. It resets itself once corrected. (Vertex HV guide, p. 56)
For a technician
- Have a qualified service technician find and correct the cause. (Vertex HV guide, p. 54)
-
The leak detection module senses water (warning; buzzer beeps continuously).Water leak detected
The leak detection module senses water (warning; buzzer beeps continuously). (Vertex HV guide, p. 56)
Likely causes
- Leak detection module voltage below 1.45 V means a water leak alarm. (Vertex HV guide, p. 55)
What you can check
- Look for the leak around the heater. Pressing the button silences the buzzer for 5 minutes; it clears when the sensor dries (above 1.55 V). (Vertex HV guide, p. 55)
-
The leak detection module is unplugged (warning; buzzer beeps once per second).LDM open
The leak detection module is unplugged (warning; buzzer beeps once per second). (Vertex HV guide, p. 56)
What you can check
- Reconnect the leak detection module. If it was unplugged on purpose, the leak function and its errors can be disabled by holding the button 5 seconds. (Vertex HV guide, p. 55)
-
A required jumper on the control board terminals is missing (hard fault).Missing short circuit between X6.6 and X6.12
A required jumper on the control board terminals is missing (hard fault). (Vertex HV guide, p. 56)
For a technician
- Have a qualified service technician find and correct the cause. (Vertex HV guide, p. 54)
-
The blower is not turning when powered (hard fault).Blower not running
The blower is not turning when powered (hard fault). (Vertex HV guide, p. 56)
For a technician
- Have a qualified service technician find and correct the cause. (Vertex HV guide, p. 54)
-
The blower speed is off target.Blower speed error
The blower speed is off target. Soft fault 3 times, then a hard fault. (Vertex HV guide, p. 56)
For a technician
- Have a qualified service technician find and correct the cause. (Vertex HV guide, p. 54)
-
The air intake pressure switch opened a third time within an hour; the air intake is blocked (soft fault).Blocked air inlet
The air intake pressure switch opened a third time within an hour; the air intake is blocked (soft fault). (Vertex HV guide, p. 56)
By model: The error-priority table on p. 57 swaps E22 and E23 (lists E22 as 1st/2nd and E23 as 3rd). The code table (p. 56) and the switch description (p. 54) both say E23 = 1st/2nd time, E22 = 3rd time.
Likely causes
- The inlet air pressure switch opens when the inlet vent is partially or totally blocked. (Vertex HV guide, p. 54)
What you can check
- Check the outside air intake termination for blockage. (Vertex HV guide, p. 54)
- After the cause is fixed, clear it: unlock the control, then hold ON/OFF and Plus together for 3 seconds. (Vertex HV guide, p. 56)
For a technician
- Have a qualified service technician find and correct the cause. (Vertex HV guide, p. 54)
-
The air intake pressure switch opened (first or second time).Blocked air inlet
The air intake pressure switch opened (first or second time). It resets after post-purge. (Vertex HV guide, p. 56)
By model: See E22 about the conflicting priority table.
Likely causes
- The inlet air pressure switch opens when the inlet vent is partially or totally blocked. (Vertex HV guide, p. 54)
What you can check
- Check the outside air intake termination for blockage. (Vertex HV guide, p. 54)
ProLine XE tankless
Three-digit codes like 111 and 991 on the controller or the remote.
-
The small DIP switches on the control board are set wrong for this heater.Incorrect DIP switch setting
The small DIP switches on the control board are set wrong for this heater. (Green LED: 1 flash.) (ProLine XE tankless manual, p. 55)
For a technician
- Turn off power, remove the front cover and set the DIP switches on the computer board to the table in the service handbook. (140H tankless service handbook, p. 12)
-
Warning: the burner is running gas-rich.Warning for the “991” error code
Warning: the burner is running gas-rich. The heater keeps running, but a 991 shutdown is coming if it is not fixed. (Green LED: 5 flashes.) (140H tankless service handbook, p. 12)
Likely causes
- Wrong gas type; blocked intake air or exhaust; direct-vent terminals too close together; high altitude; grease or dirt in the burner or fan (contaminated area). (ProLine XE tankless manual, p. 55)
What you can check
- Look for blockage at the intake air and exhaust terminals. (ProLine XE tankless manual, p. 55)
For a technician
- Check gas type, vent spacing, altitude settings and clean the burner and fan; see 991. (ProLine XE tankless manual, p. 55)
-
The heater tried to light three times and failed.Ignition failure
The heater tried to light three times and failed. (Green LED: 3 flashes.) (140H tankless service handbook, p. 12)
Likely causes
- Can be a part in the heater or an outside cause such as no gas supply. (140H tankless service handbook, p. 12)
What you can check
- Make sure the gas supply valve is fully open (preliminary checklist). (140H tankless service handbook, p. 7)
- The code resets when water stops flowing or when power is turned off and back on. (140H tankless service handbook, p. 12)
For a technician
- Check gas supply pressure in standby and while lighting; check and reset the high limit switch and overheat cutoff fuse; check igniter spark and voltage (108-132 VAC); clean or replace the flame sensor; check gas solenoid valve resistance; check venting for blockage. (140H tankless service handbook, p. 12)
- Listen for the spark and the double 'clunk' of the gas valve; check wiring, computer board burn marks, flame-rod soot and heat-exchanger leaks. (ProLine XE tankless manual, p. 55)
-
The flame lit but went out during operation.Loss of flame
The flame lit but went out during operation. (Green LED: 3 flashes.) (140H tankless service handbook, p. 12)
What you can check
- The code resets when water stops flowing or when power is turned off and back on. (140H tankless service handbook, p. 12)
For a technician
- Same checks as 111: gas pressure, high limit / overheat cutoff fuse, wiring, flame rod, heat-exchanger leaks. (ProLine XE tankless manual, p. 55)
-
The condensate drain is blocked.Blocked condensate drain system
The condensate drain is blocked. (Green LED: 5 flashes.) (X3 tankless manual, p. 54)
By model: Listed only in the X3 condensing manual (240HX3/340HX3/540HX3).
What you can check
- Check the condensate drain line and neutralizer (if installed) for blockage; make sure horizontal drain runs slope downward with no sags. (X3 tankless manual, p. 54)
For a technician
- Clear the condensate drain assembly inside the heater. (X3 tankless manual, p. 54)
-
A water temperature sensor has failed.Outlet thermistor failure / Heat exchanger thermistor failure
A water temperature sensor has failed. Which sensor depends on the model. (Green LED: 2 flashes.) (ProLine XE tankless manual, p. 55)
By model: 240H/340H, 240HX3/340HX3, 110U/310U, 110C/310C, 310CX3 and 140H: outlet thermistor. 540H, 540HX3, 540P, 510U, 510C, 510CX3: heat exchanger thermistor (2000534710 p. 55; 2000599585 p. 55; 100269776 p. 51; 2000535218 p. 42; 2000610429 p. 40; 2000536265 p. 68).
For a technician
- Check thermistor wiring for burns or cuts, check resistance against the table, clean the probe, replace if the code persists. (140H tankless service handbook, p. 13)
- 110C/310C/510C: check for connection/breakage of wires and/or debris on the thermistor. (C tankless manual, p. 42)
- 310CX3/510CX3: check for connection/breakage of wires and/or debris on the thermistor. (CX3 tankless manual, p. 40)
-
The inlet water temperature sensor has failed.Inlet thermistor failure
The inlet water temperature sensor has failed. (Green LED: 2 flashes.) (ProLine XE tankless manual, p. 55)
For a technician
- Check inlet thermistor wiring and resistance; drain the unit, clean the probe, replace if the code persists. (140H tankless service handbook, p. 13)
-
The outlet water temperature sensor has failed.Outlet thermistor failure (540 only)
The outlet water temperature sensor has failed. (Green LED: 2 flashes.) (ProLine XE tankless manual, p. 56)
By model: On the 540-size and 510-size models; on 240/340 the outlet thermistor is code 311.
For a technician
- Check thermistor wiring and debris. (ProLine XE tankless manual, p. 56)
-
The exhaust temperature sensor has failed (indoor models).Exhaust thermistor failure (indoor models only)
The exhaust temperature sensor has failed (indoor models). (Green LED: 2 flashes.) (ProLine XE tankless manual, p. 56)
For a technician
- Check exhaust thermistor wiring and resistance, clean the probe, replace if the code persists. (140H tankless service handbook, p. 14)
-
The recirculation return-water temperature sensor has failed.Return Thermistor Failure
The recirculation return-water temperature sensor has failed. (Green LED: 2 flashes.) (540P tankless manual, p. 68)
By model: Only on the 540P (built-in recirculation pump).
For a technician
- Check thermistor wiring and debris. (540P tankless manual, p. 68)
-
The air-fuel ratio (AFR) rod is reporting a fault.Air-fuel ratio rod failure
The air-fuel ratio (AFR) rod is reporting a fault. (Green LED: 2 flashes.) (ProLine XE tankless manual, p. 56)
Likely causes
- A floating ground (outlet not properly grounded) can cause this error. (140H tankless service handbook, p. 14)
What you can check
- Make sure the heater is plugged into a properly grounded outlet. (140H tankless service handbook, p. 14)
For a technician
- Check wiring and soot on the AFR rod; check the clear tube from the gas valve to the combustion chamber; clean the rod; check main gas valve voltage and resistance. (140H tankless service handbook, p. 14)
-
The water flow sensor has a fault (Easy-Link multi-unit systems).Flow sensor failure (Easy-Link System only)
The water flow sensor has a fault (Easy-Link multi-unit systems). (Green LED: 2 flashes.) (ProLine XE tankless manual, p. 56)
By model: Not listed for the X3 or CX3 manuals.
For a technician
- Check flow sensor wiring and debris on the impeller. (ProLine XE tankless manual, p. 56)
-
The main gas valve drive circuit has a fault.Abnormal main gas solenoid valve
The main gas valve drive circuit has a fault. (Green LED: 6 flashes.) (140H tankless service handbook, p. 14)
For a technician
- With hot water shut off, look through the sight glass: if flames are still visible, immediately shut off gas and power to the unit and contact technical service. (140H tankless service handbook, p. 14)
- Check gas valve wiring and connector numbering, supply gas pressure (too high can jam the valve), valve voltages (93-120 VDC) and resistances. (140H tankless service handbook, p. 14)
-
A gas solenoid valve drive circuit has a fault.Abnormal gas solenoid valve
A gas solenoid valve drive circuit has a fault. (Green LED: 6 flashes.) (140H tankless service handbook, p. 14)
For a technician
- With hot water shut off, look through the sight glass: if flames are still visible, immediately shut off gas and power to the unit and contact technical service. (140H tankless service handbook, p. 14)
- Check solenoid wiring, supply pressure, solenoid voltages (93-120 VDC) and resistances (SV1/SV2 1.35-1.65 kohm, SV3 2.07-2.53 kohm). (140H tankless service handbook, p. 15)
-
The combustion fan motor has a fault.Fan motor fault
The combustion fan motor has a fault. (Green LED: 4 flashes.) (ProLine XE tankless manual, p. 56)
Likely causes
- Broken wires, dust build-up in the fan, burn marks on the board, frozen or corroded connectors. (ProLine XE tankless manual, p. 56)
For a technician
- Turn off power, check fan wiring and board, check the fan housing for water (could mean a heat exchanger leak), remove the fan if needed. (140H tankless service handbook, p. 15)
-
The built-in recirculation pump has a fault.Pump fault
The built-in recirculation pump has a fault. (Green LED: 4 flashes.) (540P tankless manual, p. 69)
By model: Only on the 540P.
Likely causes
- Broken pump wiring, or water frozen in the pump. (540P tankless manual, p. 69)
For a technician
- Check pump wiring and whether the pump has frozen. (540P tankless manual, p. 69)
-
The flow adjustment valve has a fault.Flow adjustment valve fault (Easy-Link System only)
The flow adjustment valve has a fault. (Green LED: 4 flashes.) (ProLine XE tankless manual, p. 56)
For a technician
- Inspect the flow adjustment valve for wiring, scale-locked motor or leaks. (ProLine XE tankless manual, p. 56)
-
The bypass valve has a fault.Bypass valve fault
The bypass valve has a fault. (Green LED: 4 flashes.) (ProLine XE tankless manual, p. 56)
By model: 540-size models in the condensing manuals; also listed in the U, C and CX3 non-condensing manuals.
For a technician
- Inspect the bypass valve for wiring, scale-locked motor drive or leaks. (ProLine XE tankless manual, p. 56)
-
The computer board (PCB) or proportional gas valve has a fault.Computer board fault
The computer board (PCB) or proportional gas valve has a fault. (Green LED: 1 flash.) (ProLine XE tankless manual, p. 56)
By model: The 110U/310U/510U manual adds: check the outlet thermistor, it may need cleaning.
For a technician
- Check the proportional valve harness, board burn marks, outlet thermistor reading, proportional valve resistance (20-40 ohm) and supply gas pressure. (140H tankless service handbook, p. 16)
- 110U/310U/510U: check the outlet thermistor, as it may need to be cleaned. (U tankless manual, p. 52)
-
At power-up the control found a problem in the gas valve, high limit or overheat-fuse circuit.Gas solenoid valve drive circuit failure
At power-up the control found a problem in the gas valve, high limit or overheat-fuse circuit. (Green LED: 1 flash.) (ProLine XE tankless manual, p. 56)
For a technician
- Check the dark blue common wire, gas valve connectors, high limit switch and overheat cutoff fuse; then board or gas valve (see 510/551). (140H tankless service handbook, p. 16)
-
The control sees a flame when there should be none.False flame detection
The control sees a flame when there should be none. Shut off gas and power. (Green LED: 6 flashes.) (ProLine XE tankless manual, p. 56)
What you can check
- Shut off all gas and power to the unit. (140H tankless service handbook, p. 16)
For a technician
- Inspect and clean the flame sensor; on indoor models check a condensate drain is installed on the vent collar; check for a heat exchanger leak; call technical service. (140H tankless service handbook, p. 16)
-
The remote controller and heater are not communicating.Miscommunication between water heater and remote controller
The remote controller and heater are not communicating. (ProLine XE tankless manual, p. 56)
Likely causes
- Disconnecting the remote with power on causes this code; turn power off first. (140H tankless service handbook, p. 17)
What you can check
- Check that the remote controller is the correct model and only one remote is installed. (140H tankless service handbook, p. 16)
For a technician
- Check remote wiring and voltage at the remote (10-25 VDC); replace remote or board. (140H tankless service handbook, p. 17)
-
The built-in temperature controller and the heater are not communicating (indoor models).Miscommunication between water heater and temperature controller (indoor models only)
The built-in temperature controller and the heater are not communicating (indoor models). (ProLine XE tankless manual, p. 56)
For a technician
- Check controller wiring and voltage (11-25 VDC); replace controller or board. (140H tankless service handbook, p. 17)
-
Units in a multi-heater Easy-Link system are not communicating.Miscommunication in Easy-Link System
Units in a multi-heater Easy-Link system are not communicating. (ProLine XE tankless manual, p. 56)
For a technician
- Check the parent/child unit connections. (ProLine XE tankless manual, p. 56)
-
The exhaust got too hot and the exhaust high-limit shut the burner down.Abnormal exhaust temperature (indoor models only)
The exhaust got too hot and the exhaust high-limit shut the burner down. (Green LED: 5 flashes.) (140H tankless service handbook, p. 17)
By model: X3 manual lists fan-motor wiring/dust checks for 941 instead (2000599585 p. 55).
Likely causes
- Set temperature above 140°F (60°C) on a recirculation system. (ProLine XE tankless manual, p. 56)
- 540P: inlet and return water hotter than 140°F (60°C) in the recirculation system. (540P tankless manual, p. 69)
What you can check
- If the heater is on a recirculation system, check whether the set temperature is above 140°F. (ProLine XE tankless manual, p. 56)
For a technician
- Check vent length and blockage, dust/lint in burner and heat exchanger, manifold pressure, incoming water temperature (above 140°F can cause it), exhaust thermistor resistance. (140H tankless service handbook, p. 17)
-
The burner is not burning cleanly, so the heater shut down (follows the 101 warning).Imperfect combustion
The burner is not burning cleanly, so the heater shut down (follows the 101 warning). (Green LED: 5 flashes.) (ProLine XE tankless manual, p. 56)
Likely causes
- Wrong gas type; blocked intake or exhaust; direct-vent terminals too close; altitude; grease or dirt in burner or fan. (ProLine XE tankless manual, p. 56)
What you can check
- Look for blockage at the intake air and exhaust terminals. (ProLine XE tankless manual, p. 56)
For a technician
- Verify gas type and DIP switches (vent length, elevation), gas pressure and line sizing, vent obstructions and terminal clearances, and contamination in fan/burner. (140H tankless service handbook, p. 17)
Adapt tankless
An E and three digits, like E002, on the display or the remote.
-
A high-temperature safety switch tripped.High Limit Break / Hi-Limit Switches
A high-temperature safety switch tripped. (Adapt condensing guide, p. 60)
By model: Premium (ATHR) has two switches: a manual-reset switch on the water outlet and an automatic one on the burner door (2000628591 p. 60).
For a technician
- Check the manual hi-limit switch and press its reset button (center of the switch); you will hear/feel a click. If it keeps tripping, have it serviced. (Adapt condensing guide, p. 60)
- Premium: if the automatic hi-limit switch on the burner door tripped, it cannot be reset and must be replaced. (Adapt Premium guide, p. 60)
-
The control board found a hardware fault.PCB Hardware Fault - AD Converter Fault
The control board found a hardware fault. (Adapt condensing guide, p. 60)
For a technician
- Check PCB wiring for loose, damaged or cut wires/connectors; if all are intact, replace the PCB. (Adapt condensing guide, p. 60)
-
The control sees the wrong power frequency (should be 60 Hz).Frequency Fault
The control sees the wrong power frequency (should be 60 Hz). (Adapt condensing guide, p. 60)
What you can check
- Check that setting C07 shows 60 (60 Hz) using the C Mode menu described in the manual. (Adapt condensing guide, p. 60)
For a technician
- If the error still occurs, contact a qualified service technician. (Adapt condensing guide, p. 60)
-
The control board has a memory fault.PCB Hardware Fault - Memory Error
The control board has a memory fault. A single heater keeps running; a cascade system is affected. (Adapt condensing guide, p. 60)
By model: Premium: the heater keeps operating but the recirculation pump is disabled (2000628591 p. 60).
Likely causes
- Parent heater: the cascade system will not operate; child heater: that heater will not operate. (Adapt condensing guide, p. 60)
For a technician
- Cascade: remove this heater from the cascade and set a different heater as parent. (Adapt condensing guide, p. 60)
-
The flame failed.Flame Failure
The flame failed. (Adapt condensing guide, p. 60)
For a technician
- Check the flame sensor wire for a short or disconnection; repair; if it still occurs, call a qualified technician. (Adapt condensing guide, p. 60)
-
The control sees a flame while the heater should be idle.False Flame Detection (During Standby)
The control sees a flame while the heater should be idle. (Adapt condensing guide, p. 60)
By model: SC, NC and Premium list E037; Premium also has E384 'False Flame Detection'.
What you can check
- If the error persists, immediately shut off the water heater and contact a qualified service technician. (Adapt condensing guide, p. 60)
For a technician
- Check for a visible flame through the sight glass while no water is running. (Adapt condensing guide, p. 60)
- Check the flame sensor wire for a short or disconnection. (Adapt condensing guide, p. 60)
-
The heater failed to light.Ignition Failure
The heater failed to light. (Adapt condensing guide, p. 61)
For a technician
- Check for a visible flame through the sight glass. (Adapt condensing guide, p. 61)
- Check the flame sensor wire (Premium: also the igniter wire) for a short or disconnection. (Adapt Premium guide, p. 61)
- If the error still occurs, contact a qualified service technician. (Adapt condensing guide, p. 61)
-
The outlet water is reading too hot.Outlet Water Over-temp
The outlet water is reading too hot. (Adapt condensing guide, p. 61)
For a technician
- Compare the thermistor reading with the outlet water temperature; remove the outlet thermistor (keep the O-ring), clean with emery cloth, replace if damaged. (Adapt condensing guide, p. 61)
-
The control board’s clock battery is low.Clock Battery Replacement
The control board’s clock battery is low. It can also appear right after power comes back on; then ignore it. (Adapt Premium guide, p. 61)
By model: Premium (ATHR) only.
For a technician
- Replace the PCB battery with a 2032 type (remove its plastic cover first). (Adapt Premium guide, p. 61)
-
A temperature sensor has failed.Exhaust Thermistor Failure (SC, Premium) / Fan Thermistor Failure (NC)
A temperature sensor has failed. On condensing models it is the exhaust sensor; on the non-condensing NC it is the fan sensor. (Adapt condensing guide, p. 61)
By model: Same code, different sensor: Adapt NC manual calls E049 'Fan Thermistor Failure' (100385425 p. 58); SC and Premium call it 'Exhaust Thermistor Failure'.
For a technician
- Remove the thermistor (keep the O-ring), clean with emery cloth, replace if damaged; check its wire for a short or disconnection. (Adapt condensing guide, p. 61)
-
The inlet water temperature sensor has failed.Inlet Thermistor Failure
The inlet water temperature sensor has failed. (Adapt condensing guide, p. 61)
For a technician
- Remove, clean or replace the inlet thermistor; check its wire. (Adapt condensing guide, p. 61)
-
The outlet water temperature sensor has failed.Outlet Thermistor Failure
The outlet water temperature sensor has failed. (Adapt condensing guide, p. 61)
For a technician
- Remove, clean or replace the outlet thermistor; check its wire. (Adapt condensing guide, p. 61)
-
The heat exchanger temperature sensor has failed.Heat Exchanger Thermistor Failure
The heat exchanger temperature sensor has failed. (Adapt condensing guide, p. 61)
For a technician
- Remove, clean or replace the thermistor; check its wire. (Adapt condensing guide, p. 61)
-
The control has an incorrect setting.Incorrect Setting
The control has an incorrect setting. (Adapt non-condensing guide, p. 58)
By model: Listed only in the Adapt NC manual.
For a technician
- Contact a qualified service technician to replace the PCB. (Adapt non-condensing guide, p. 58)
-
Combustion air or exhaust is blocked.Combustion Blockage
Combustion air or exhaust is blocked. (Adapt condensing guide, p. 61)
By model: SC and NC manuals.
What you can check
- With power disconnected, check the exhaust vent and air intake piping for blockages and remove them. (Adapt condensing guide, p. 61)
- Make sure the heater has enough combustion air. (Adapt condensing guide, p. 61)
For a technician
- If the error still occurs, contact a qualified service technician. (Adapt condensing guide, p. 61)
-
The proportional gas valve current is abnormal.Abnormal Proportional Valve Current
The proportional gas valve current is abnormal. (Adapt condensing guide, p. 62)
By model: SC and NC manuals.
For a technician
- Check proportional valve wiring. (Adapt condensing guide, p. 62)
- If the error still occurs, contact a qualified service technician. (Adapt condensing guide, p. 62)
-
Water coming into the heater is too hot.Inlet Water Over-temp
Water coming into the heater is too hot. (Adapt condensing guide, p. 62)
What you can check
- Check that the water coming into the heater is not hotter than the set temperature (SC also says not above 122°F / 50°C). (Adapt condensing guide, p. 62)
For a technician
- Remove and clean the inlet thermistor; check its wire. (Adapt condensing guide, p. 62)
-
The control sees a flame when it shouldn’t.False Flame Detection
The control sees a flame when it shouldn’t. (Adapt Premium guide, p. 62)
By model: Premium (ATHR) only.
What you can check
- If a flame is seen with no hot water running, immediately shut off the gas to the heater and contact a qualified technician before using it. (Adapt Premium guide, p. 62)
For a technician
- Look through the sight glass for a flame; if none but the display flame LED is lit, check the flame sensor wire. (Adapt Premium guide, p. 62)
-
The main gas valve circuit has a fault.Main Gas Solenoid Valve Drive Circuit Failure (SC/NC) / Gas Valve - SV1 (Premium)
The main gas valve circuit has a fault. (Adapt condensing guide, p. 62)
For a technician
- Check gas valve wiring; if it still occurs, have a qualified technician replace the gas valve. (Adapt Premium guide, p. 62)
-
The bypass valve has a fault.Bypass Valve Fault
The bypass valve has a fault. (Adapt condensing guide, p. 62)
For a technician
- Fix wiring; drain the heater, remove and inspect the bypass valve, replace if needed. (Adapt condensing guide, p. 62)
-
The control board’s fan-current circuit failed.Fan Current AD Failure
The control board’s fan-current circuit failed. (Adapt condensing guide, p. 62)
By model: SC and NC manuals.
For a technician
- Replace the PCB. (Adapt condensing guide, p. 62)
-
The fan draws too much current while idle.Fan Over Max Current (During Standby)
The fan draws too much current while idle. (Adapt condensing guide, p. 62)
By model: SC and NC manuals.
For a technician
- Check fan motor wiring. (Adapt condensing guide, p. 62)
- If the error still occurs, contact a qualified service technician. (Adapt condensing guide, p. 62)
-
The fan draws too much current while running.Fan Over Max Current (During Operation)
The fan draws too much current while running. (Adapt condensing guide, p. 62)
By model: SC and NC manuals.
For a technician
- Check fan motor wiring. (Adapt condensing guide, p. 62)
- If the error still occurs, contact a qualified service technician. (Adapt condensing guide, p. 62)
-
The fan started when it shouldn’t.Fan False Start (During Operation) / Fan - False Start
The fan started when it shouldn’t. (Adapt condensing guide, p. 62)
For a technician
- Check fan motor wiring. (Adapt condensing guide, p. 62)
- If the error still occurs, contact a qualified service technician. (Adapt condensing guide, p. 62)
-
The fan speed signal was lost.Fan Signal Loss
The fan speed signal was lost. (Adapt condensing guide, p. 62)
For a technician
- Check fan motor wiring. (Adapt condensing guide, p. 62)
- If the error still occurs, contact a qualified service technician. (Adapt condensing guide, p. 62)
-
The fan can’t reach its target speed.Fan Target Speed
The fan can’t reach its target speed. (Adapt condensing guide, p. 62)
What you can check
- With power disconnected, check the exhaust vent and air intake piping for blockages and remove them. (Adapt condensing guide, p. 62)
For a technician
- Check fan motor wiring. (Adapt condensing guide, p. 62)
-
The fan shows current when it isn’t being driven.Fan Current without Drive (During Standby)
The fan shows current when it isn’t being driven. (Adapt condensing guide, p. 62)
By model: SC and NC manuals.
For a technician
- Check fan motor wiring. (Adapt condensing guide, p. 62)
- If the error still occurs, contact a qualified service technician. (Adapt condensing guide, p. 62)
-
The built-in recirculation pump is running too slow.Pump - Low Speed
The built-in recirculation pump is running too slow. (Adapt Premium guide, p. 63)
By model: Premium (ATHR) only.
What you can check
- Check the inlet filter for debris and clean it. (Adapt Premium guide, p. 63)
For a technician
- Check pump wiring, pump and lines for debris, faulty check valves, and recirculation pipe length/size limits. (Adapt Premium guide, p. 63)
-
The recirculation pump draws too little current.Pump - Low Current
The recirculation pump draws too little current. (Adapt Premium guide, p. 63)
By model: Premium only.
For a technician
- Check pump wiring voltage. (Adapt Premium guide, p. 63)
- If the error still occurs, contact a qualified service technician. (Adapt Premium guide, p. 63)
-
The recirculation pump sees too little water flow.Pump - Low Water Flow
The recirculation pump sees too little water flow. (Adapt Premium guide, p. 63)
By model: Premium only.
What you can check
- Check the inlet filter for debris and clean it; check for a shutoff valve left closed. (Adapt Premium guide, p. 63)
For a technician
- Check pump wiring, debris, a check valve stuck closed, and pipe length/size limits. (Adapt Premium guide, p. 63)
-
The recirculation pump is drawing too much power.Pump - Power Limit Exceeded
The recirculation pump is drawing too much power. (Adapt Premium guide, p. 63)
By model: Premium only.
For a technician
- Check pump wiring. (Adapt Premium guide, p. 63)
- If the error still occurs, contact a qualified service technician. (Adapt Premium guide, p. 63)
-
The display (UIM) is not communicating with the board.Communication Fault with UIM
The display (UIM) is not communicating with the board. (Adapt condensing guide, p. 63)
For a technician
- Check UIM wiring. (Adapt condensing guide, p. 63)
- If the error still occurs, contact a qualified service technician. (Adapt condensing guide, p. 63)
-
The remote controller is not communicating.Communication Fault with Remote Controller
The remote controller is not communicating. (Adapt condensing guide, p. 63)
What you can check
- Make sure only one remote controller is installed. (Adapt condensing guide, p. 63)
For a technician
- Check remote controller wiring. (Adapt condensing guide, p. 63)
-
Heaters in a cascade are not communicating.Communication Fault in Cascade System
Heaters in a cascade are not communicating. (Adapt condensing guide, p. 63)
What you can check
- If the cascade wiring was disconnected while powered, cycle the heater’s power off and on. (Adapt condensing guide, p. 63)
For a technician
- Check cascade wiring. (Adapt condensing guide, p. 63)
-
The fan is running too slow.Fan - Low Speed
The fan is running too slow. (Adapt Premium guide, p. 64)
By model: Premium only.
What you can check
- With power disconnected, check the exhaust vent and air intake piping for blockages. (Adapt Premium guide, p. 64)
For a technician
- Check fan wiring. (Adapt Premium guide, p. 64)
-
Heaters of different models are linked in one cascade.Inconsistent Models in Cascade-Link
Heaters of different models are linked in one cascade. (Adapt condensing guide, p. 63)
By model: SC and NC manuals.
For a technician
- Confirm all units in the cascade are the same model. (Adapt condensing guide, p. 63)
-
The water in the heat exchanger is overheating.Heat Exchanger - Water Overheating
The water in the heat exchanger is overheating. (Adapt Premium guide, p. 64)
By model: Premium only.
For a technician
- Remove and clean the heat exchanger thermistor; check its wire. (Adapt Premium guide, p. 64)
-
The control board has a hardware fault.PCB Hardware Fault - Flame Circuit Failure / PCB - Hardware
The control board has a hardware fault. (Adapt condensing guide, p. 63)
For a technician
- Have a qualified technician replace the PCB. (Adapt condensing guide, p. 63)
-
The flame sensor is reporting a fault.Flame Sensor Fault
The flame sensor is reporting a fault. (Adapt condensing guide, p. 63)
What you can check
- With power disconnected, check the exhaust vent and air intake for blockages; make sure there is enough combustion air and no corrosive chemicals in the area. (Adapt condensing guide, p. 63)
For a technician
- Check the flame sensor wire. (Adapt condensing guide, p. 63)
-
The board’s flame sensor circuit has a fault.PCB - Flame Sensor Circuit
The board’s flame sensor circuit has a fault. (Adapt condensing guide, p. 63)
For a technician
- Check the flame sensor wire; otherwise replace the PCB. (Adapt condensing guide, p. 63)
-
The gas valve has a fault.Gas Valve Fault
The gas valve has a fault. (Adapt Premium guide, p. 64)
By model: Premium only.
For a technician
- Check gas valve wiring. (Adapt Premium guide, p. 64)
- If the error still occurs, contact a qualified service technician. (Adapt Premium guide, p. 64)
-
A sensor reading is out of range (linked to the outlet thermistor or the board).Analog/Digital (AD) Value Fault
A sensor reading is out of range (linked to the outlet thermistor or the board). (Adapt condensing guide, p. 63)
For a technician
- Check the outlet thermistor wire; remove and clean the thermistor; otherwise replace the PCB. (Adapt condensing guide, p. 63)
-
The flame sensor (or related sensors) reports a fault.Flame Sensor Fault
The flame sensor (or related sensors) reports a fault. (Adapt Premium guide, p. 65)
By model: Premium only.
For a technician
- Check flame sensor, inlet and heat exchanger thermistor wires; clean or replace those thermistors. (Adapt Premium guide, p. 65)
-
The exhaust is too hot.Exhaust High Temperature
The exhaust is too hot. (Adapt condensing guide, p. 64)
What you can check
- With power disconnected, check the exhaust vent and air intake piping for blockages. (Adapt condensing guide, p. 64)
For a technician
- Remove and clean the exhaust thermistor; replace if damaged. (Adapt condensing guide, p. 64)
-
The flame signal was lost.Flame Signal Lost
The flame signal was lost. (Adapt condensing guide, p. 64)
By model: SC and NC manuals.
What you can check
- With power disconnected, check the exhaust vent and air intake piping for blockages. (Adapt condensing guide, p. 64)
For a technician
- Check the flame sensor wire. (Adapt condensing guide, p. 64)
-
Gas valve solenoid 2 has a voltage fault.Gas Valve - SV2
Gas valve solenoid 2 has a voltage fault. (Adapt Premium guide, p. 65)
By model: Premium only.
For a technician
- Check wiring; otherwise have the gas valve replaced. (Adapt Premium guide, p. 65)
-
The pressure switch reports a problem.Pressure Switch
The pressure switch reports a problem. (Adapt Premium guide, p. 65)
By model: Premium only.
What you can check
- With power disconnected, check the exhaust vent and air intake piping for blockages. (Adapt Premium guide, p. 65)
For a technician
- Check pressure switch wires and the pressure tube for loose connections, debris or blockage. (Adapt Premium guide, p. 65)
-
The venturi assembly has a wiring fault.Venturi Assembly
The venturi assembly has a wiring fault. (Adapt Premium guide, p. 65)
By model: Premium only.
For a technician
- Check venturi assembly wires. (Adapt Premium guide, p. 65)
- If the error still occurs, contact a qualified service technician. (Adapt Premium guide, p. 65)
-
The condensate drain is backing up.Condensate Drain Overflow
The condensate drain is backing up. (Adapt condensing guide, p. 64)
By model: Condensing models (SC, Premium).
What you can check
- Put a bucket under the heater; with the heater off, check the condensate drain line for blockage and clear it. (Adapt condensing guide, p. 64)
For a technician
- Check condensate drain wires and the internal trap (Premium); verify the drain is installed correctly. (Adapt Premium guide, p. 65)
-
The flow control valve has a fault.Flow Control Valve
The flow control valve has a fault. (Adapt condensing guide, p. 64)
For a technician
- Check its wiring; drain the heater, remove and inspect the valve, replace if needed. (Adapt condensing guide, p. 64)
-
The flow sensor reports a problem (cascade systems).Flow Sensor - Cascade Only
The flow sensor reports a problem (cascade systems). (Adapt condensing guide, p. 64)
What you can check
- Make sure the heater is enabled (display shows set temperature; press ON/OFF if not) and its water shutoff valves are open. (Adapt condensing guide, p. 64)
For a technician
- Check flow sensor wires; drain, remove and inspect the flow sensor; clean the inlet water filter. (Adapt condensing guide, p. 64)
-
The flow control valve has a fault (cascade systems).Flow Control Valve Fault - Cascade Only
The flow control valve has a fault (cascade systems). (Adapt condensing guide, p. 65)
For a technician
- Check its wiring; drain, remove and inspect the valve. (Adapt condensing guide, p. 65)
Heat pump and electric tanks
Voltex and other hybrid heat pumps, and electric tanks with an electronic control.
-
The heater is running a self-check.- -- --- (series of dashes)
The heater is running a self-check. Normal. (Voltex heat pump guide, p. 20)
-
The heat pump is defrosting.ICE
The heat pump is defrosting. Normal. (Voltex heat pump guide, p. 20)
-
The air around the heater is too cold or too hot for the heat pump right now.HPO
The air around the heater is too cold or too hot for the heat pump right now. Normal; elements may do the heating. (Voltex heat pump guide, p. 20)
-
The upper heating element is not working.EUC
The upper heating element is not working. (Voltex heat pump guide, p. 20)
For a technician
- Check the upper heating element and replace it if needed. (Voltex heat pump guide, p. 20)
-
The lower heating element is not working.ELC
The lower heating element is not working. (Voltex heat pump guide, p. 20)
For a technician
- Check and replace the heating element as needed. (Voltex heat pump guide, p. 20)
-
The air filter needs cleaning.SF
The air filter needs cleaning. (Voltex heat pump guide, p. 20)
What you can check
- Clean the air filter (see 'Air Filter Maintenance'). (Voltex heat pump guide, p. 20)
- FPTU (6-year Voltex): turn off power at the breaker, then clean the air filter. (Voltex heat pump guide (6-year), p. 20)
-
The compressor keeps short-cycling.ECF
The compressor keeps short-cycling. (Voltex heat pump guide, p. 20)
What you can check
- Clean the air filter; check that the install space meets the confined-space requirements. (Voltex heat pump guide, p. 20)
For a technician
- Call A. O. Smith technical assistance (number on the warranty sheet). (Voltex heat pump guide, p. 20)
-
The upper tank temperature sensor has failed.E20 or E21
The upper tank temperature sensor has failed. (Voltex heat pump guide, p. 20)
For a technician
- Power off, reseat control-board connectors J2 and J5, inspect wire, reconnect power; replace the sensor if the error persists. (Voltex heat pump guide, p. 20)
-
The lower tank temperature sensor has failed.E30 or E31
The lower tank temperature sensor has failed. (Voltex heat pump guide, p. 20)
For a technician
- Same as E20: reseat J2/J5, inspect wire, replace sensor. (Voltex heat pump guide, p. 20)
-
A heat pump temperature sensor (suction) has failed.E50 or E51
A heat pump temperature sensor (suction) has failed. (Voltex heat pump guide, p. 20)
For a technician
- Reseat J2/J5, inspect wire, replace sensor. (Voltex heat pump guide, p. 20)
-
The heat pump coil temperature sensor has failed.E10 or E11
The heat pump coil temperature sensor has failed. (Voltex heat pump guide, p. 20)
For a technician
- Reseat J2/J5, inspect wire, replace sensor. (Voltex heat pump guide, p. 20)
-
The compressor discharge temperature sensor has failed.E40 or E41
The compressor discharge temperature sensor has failed. (Voltex heat pump guide, p. 20)
For a technician
- Reseat J2/J5, inspect wire, replace sensor. (Voltex heat pump guide, p. 20)
-
Both tank temperature sensors have failed.E60
Both tank temperature sensors have failed. (Voltex heat pump guide, p. 20)
By model: Not listed in the 2015 FPTU manual (100264133).
For a technician
- Reseat J2/J5, inspect wires, replace sensors. (Voltex heat pump guide, p. 20)
-
The tank is not full of water.Edr
The tank is not full of water. (Voltex heat pump guide, p. 20)
What you can check
- Open all hot water taps in the home and run them until water flows without interruption from every tap. (Voltex heat pump guide, p. 20)
-
The incoming voltage is too low.EPL
The incoming voltage is too low. (Voltex heat pump guide, p. 20)
For a technician
- Check for loose electrical connections. (Voltex heat pump guide, p. 20)
-
The compressor is running too hot.EDH
The compressor is running too hot. (Voltex heat pump guide, p. 20)
For a technician
- Call A. O. Smith technical assistance (number on the warranty sheet). (Voltex heat pump guide, p. 20)
-
The condensate is not draining.EoF
The condensate is not draining. (Voltex heat pump guide, p. 21)
What you can check
- Make sure the unit is level and the primary and secondary condensate drain lines are clear; if an accessory condensate pump is used, make sure it is plugged in and working. (Voltex heat pump guide, p. 21)
For a technician
- Check condensate pump control wiring; repair or replace the pump. (Voltex heat pump guide, p. 21)
-
Refrigerant suction pressure is too low.ECL
Refrigerant suction pressure is too low. (Voltex heat pump guide, p. 21)
For a technician
- Call A. O. Smith technical assistance (number on the warranty sheet). (Voltex heat pump guide, p. 21)
-
The control’s memory chip failed.EEE
The control’s memory chip failed. (Voltex heat pump guide, p. 21)
What you can check
- Power cycle the unit. (Voltex heat pump guide, p. 21)
For a technician
- Call A. O. Smith technical assistance (number on the warranty sheet). (Voltex heat pump guide, p. 21)
-
The compressor is not working.ECC
The compressor is not working. (Voltex heat pump guide, p. 21)
For a technician
- Call A. O. Smith technical assistance (number on the warranty sheet). (Voltex heat pump guide, p. 21)
-
There is a power supply error.ECE
There is a power supply error. (Voltex heat pump guide, p. 21)
For a technician
- Call A. O. Smith technical assistance (number on the warranty sheet). (Voltex heat pump guide, p. 21)
-
Power was turned on with the tank not full of water.001 with alert indicator flashing
Power was turned on with the tank not full of water. (Voltex MAX guide, p. 25)
What you can check
- Turn off power at the breaker, fill the tank and open a hot faucet until water flows with no air bursts, then turn power back on. (Voltex MAX guide, p. 25)
-
The upper tank sensor failed (runs in Limp Mode 1).003 with alert indicator flashing
The upper tank sensor failed (runs in Limp Mode 1). (Voltex MAX guide, p. 25)
For a technician
- Power off; check connections at the Control Assembly board; replace the thermistor if wiring is OK. (Voltex MAX guide, p. 25)
-
The lower tank sensor failed (runs in Limp Mode 2).004 with alert indicator flashing
The lower tank sensor failed (runs in Limp Mode 2). (Voltex MAX guide, p. 25)
For a technician
- Power off; check connections; replace the thermistor. (Voltex MAX guide, p. 25)
-
The control’s processor found an internal fault.006 with alert indicator flashing
The control’s processor found an internal fault. (Voltex MAX guide, p. 25)
What you can check
- Turn power OFF at the breaker, then back ON, to see if the code clears. (Voltex MAX guide, p. 25)
For a technician
- If it does not clear, replace the Control Assembly. (Voltex MAX guide, p. 25)
-
Incoming voltage is too low (Limp Mode 3).009 with alert indicator flashing
Incoming voltage is too low (Limp Mode 3). (Voltex MAX guide, p. 25)
For a technician
- Check for loose electrical connections. (Voltex MAX guide, p. 25)
-
The upper element circuit failed; the lower element still works (Limp Mode 1).021 with alert indicator flashing
The upper element circuit failed; the lower element still works (Limp Mode 1). (Voltex MAX guide, p. 26)
For a technician
- Power off; check element resistance (5-25 ohms) and wiring; replace as needed. (Voltex MAX guide, p. 26)
-
The lower element circuit failed; the upper element still works (Limp Mode 2).022 with alert indicator flashing
The lower element circuit failed; the upper element still works (Limp Mode 2). (Voltex MAX guide, p. 26)
For a technician
- Power off; check element resistance (5-25 ohms) and wiring; replace as needed. (Voltex MAX guide, p. 26)
-
The heat pump coil temperature sensor has a problem; the heat pump stops and the elements heat (Limp Mode 3).025 with alert indicator flashing
The heat pump coil temperature sensor has a problem; the heat pump stops and the elements heat (Limp Mode 3). (Voltex MAX guide, p. 26)
For a technician
- Power off, reseat J9 on the control board, inspect wire, reconnect; replace the sensor if it persists. (Voltex MAX guide, p. 26)
-
The heat pump suction temperature sensor has a problem; the heat pump stops and the elements heat (Limp Mode 3).026 with alert indicator flashing
The heat pump suction temperature sensor has a problem; the heat pump stops and the elements heat (Limp Mode 3). (Voltex MAX guide, p. 26)
For a technician
- Power off, reseat J9 on the control board, inspect wire, reconnect; replace the sensor if it persists. (Voltex MAX guide, p. 26)
-
The heat pump discharge temperature sensor has a problem; the heat pump stops and the elements heat (Limp Mode 3).027 with alert indicator flashing
The heat pump discharge temperature sensor has a problem; the heat pump stops and the elements heat (Limp Mode 3). (Voltex MAX guide, p. 26)
For a technician
- Power off, reseat J9 on the control board, inspect wire, reconnect; replace the sensor if it persists. (Voltex MAX guide, p. 26)
-
The ambient temperature sensor has a problem; the heat pump stops and the elements heat (Limp Mode 3).028 with alert indicator flashing
The ambient temperature sensor has a problem; the heat pump stops and the elements heat (Limp Mode 3). (Voltex MAX guide, p. 26)
By model: Manual adds 'Heat Pump Compressor is outside of operational temperature range'.
For a technician
- Power off, reseat J9 on the control board, inspect wire, reconnect; replace the sensor if it persists. (Voltex MAX guide, p. 26)
-
The outlet temperature sensor failed; Guest and Hot Water+ modes are unavailable.029 with alert indicator flashing
The outlet temperature sensor failed; Guest and Hot Water+ modes are unavailable. (Voltex MAX guide, p. 26)
By model: Not listed for HPTS (100379659).
For a technician
- Power off, reseat J3, inspect wires; replace the outlet sensor if it persists. (Voltex MAX guide, p. 26)
-
The leak sensor detected water.031 with alert indicator flashing
The leak sensor detected water. (Voltex MAX guide, p. 26)
What you can check
- Check for plumbing leaks and correct them. (Voltex MAX guide, p. 26)
For a technician
- With power off, check electrical connections and wiring; if the tank is leaking, replace the unit. (Voltex MAX guide, p. 26)
-
The anode rod is used up.044 with alert indicator flashing
The anode rod is used up. (Voltex MAX guide, p. 26)
By model: An A. O. Smith addendum (100392298) says code 044 'is no longer applicable to this water heater' but later in the same addendum says the control will display 044 when the anode is depleted.
For a technician
- Power off, shut the cold water, relieve pressure, remove and inspect the anode, replace if needed. (Voltex MAX guide, p. 26)
- Addendum: the control assembly will display 044 when the anode rod has been depleted; anode replacement steps are in the addendum. (Heat pump addendum, p. 1)
-
The automatic shut-off valve has a problem.046 with alert indicator flashing
The automatic shut-off valve has a problem. (Voltex MAX guide, p. 26)
For a technician
- Power off, close cold water, relieve pressure, check the valve is not stuck, replace if needed, refill and bleed air. (Voltex MAX guide, p. 26)
-
The Smart Valve failed; Guest and Hot Water+ modes are unavailable.047 with alert indicator flashing
The Smart Valve failed; Guest and Hot Water+ modes are unavailable. (Voltex MAX guide, p. 27)
By model: Not listed for HPTS.
What you can check
- Turn power OFF at the breaker, then back ON, to see if the code clears. (Voltex MAX guide, p. 27)
For a technician
- If the error persists, replace the Smart Valve. (Voltex MAX guide, p. 27)
-
The control’s backup battery is low.048 with alert indicator flashing
The control’s backup battery is low. (Voltex MAX guide, p. 27)
By model: Battery low is 048 on these heat pumps but 045 on the electric smart models.
For a technician
- Remove the battery tray (Phillips screw) on the Control Assembly and replace with Panasonic BR2032 or Murata CR2032 only. (Voltex MAX guide, p. 27)
-
The air filter needs cleaning.080 with alert indicator flashing
The air filter needs cleaning. (Voltex MAX guide, p. 27)
What you can check
- Slide the air filter out of the intake duct adaptor on top, vacuum it or replace it, and put it back. (Voltex MAX guide, p. 27)
- HPTV (120 V) and HPTS (AL Smart): same code and filter steps. (Voltex 120-volt guide, p. 27)
- HPTS (AL Smart): same code and filter steps. (Voltex AL guide, p. 27)
-
The condensate is not draining (Limp Mode 3).081 with alert indicator flashing
The condensate is not draining (Limp Mode 3). (Voltex MAX guide, p. 27)
What you can check
- Make sure the unit is level, the condensate drain line is clear, and any condensate pump is plugged in and working. (Voltex MAX guide, p. 27)
For a technician
- Check condensate pump control wiring; repair or replace the pump. (Voltex MAX guide, p. 27)
-
Refrigerant suction pressure is too low.083 with alert indicator flashing
Refrigerant suction pressure is too low. The heat pump stops and the elements heat (Limp Mode 3). (Voltex MAX guide, p. 27)
By model: Alarm beeps if triggered 3 times in 1 hour.
For a technician
- Call A. O. Smith technical assistance (number on the warranty sheet). (Voltex MAX guide, p. 27)
-
The compressor is not working.084 with alert indicator flashing
The compressor is not working. The heat pump stops and the elements heat (Limp Mode 3). (Voltex MAX guide, p. 27)
By model: Alarm beeps if triggered 3 times in 1 hour.
For a technician
- Call A. O. Smith technical assistance (number on the warranty sheet). (Voltex MAX guide, p. 27)
-
The compressor is running too hot.085 with alert indicator flashing
The compressor is running too hot. The heat pump stops and the elements heat (Limp Mode 3). (Voltex MAX guide, p. 27)
By model: Alarm beeps if triggered 3 times in 1 hour.
For a technician
- Call A. O. Smith technical assistance (number on the warranty sheet). (Voltex MAX guide, p. 27)
-
The fan is not reporting the right speed.086 with alert indicator flashing
The fan is not reporting the right speed. The heat pump stops and the elements heat (Limp Mode 3). (Voltex MAX guide, p. 27)
By model: Alarm beeps if triggered 3 times in 1 hour (086: 3 times in 72 hours).
For a technician
- Call A. O. Smith technical assistance (number on the warranty sheet). (Voltex MAX guide, p. 27)
-
Power was turned on with the tank not full of water.001 with an alert indicator flashing.
Power was turned on with the tank not full of water. (Electric smart valve guide, p. 20)
What you can check
- Turn off power at the breaker, fill the tank and bleed air at a hot faucet, then turn power back on. (Electric smart valve guide, p. 20)
- Grid-capable ProLine: same code and steps. (Grid-capable electric guide, p. 20)
- ProLine Master smart: same code and steps. (Electric control guide, p. 20)
-
The water got too hot and the high-limit (ECO) tripped.002 with an alert indicator flashing.
The water got too hot and the high-limit (ECO) tripped. (Electric smart valve guide, p. 20)
By model: Electric models only; the smart heat pump list has no 002.
For a technician
- Power off at breaker, press the ECO reset button, power on; if it returns, test for a grounded element and replace; if both elements test good, replace the upper thermostat. (Electric smart valve guide, p. 20)
-
The upper sensor (part of the thermostat) failed; runs in Limp Mode.003 with an alert indicator flashing.
The upper sensor (part of the thermostat) failed; runs in Limp Mode. (Electric smart valve guide, p. 20)
For a technician
- Power off, check connections at the thermostat, replace the thermostat if wiring is OK. (Electric smart valve guide, p. 20)
-
The lower sensor (part of the thermostat) failed; runs in Limp Mode.004 with an alert indicator flashing.
The lower sensor (part of the thermostat) failed; runs in Limp Mode. (Electric smart valve guide, p. 20)
For a technician
- Power off, check connections, replace the thermostat. (Electric smart valve guide, p. 20)
-
The control found an internal processor fault.006 with an alert indicator flashing.
The control found an internal processor fault. (Electric smart valve guide, p. 20)
What you can check
- Turn power OFF at the breaker, then back ON, to see if the code clears. (Electric smart valve guide, p. 20)
For a technician
- If not cleared, replace the control assembly. (Electric smart valve guide, p. 20)
-
The upper element circuit failed; the lower element still works.021 with an alert indicator flashing.
The upper element circuit failed; the lower element still works. (Electric smart valve guide, p. 20)
For a technician
- Power off; check element resistance (5-25 ohms) and wiring. (Electric smart valve guide, p. 20)
-
The lower element circuit failed; the upper element still works.022 with an alert indicator flashing.
The lower element circuit failed; the upper element still works. (Electric smart valve guide, p. 21)
By model: Manual: false alarms can occur from repeated draws, such as a recirculation pump.
For a technician
- Power off; check element resistance (5-25 ohms) and wiring. (Electric smart valve guide, p. 21)
-
The outlet temperature sensor failed (smart valve models).029 with alert indicator flashing
The outlet temperature sensor failed (smart valve models). (Electric smart valve guide, p. 21)
By model: Smart valve PESX/PETX manual only.
For a technician
- Power off, reseat J3, inspect wires, replace the outlet sensor. (Electric smart valve guide, p. 21)
-
The leak sensor detected water.031 with an alert indicator flashing.
The leak sensor detected water. (Electric smart valve guide, p. 21)
By model: Also in the ProLine Master smart manual (100341152); not in the grid-capable list (100354544).
What you can check
- Check for plumbing leaks and correct them. (Electric smart valve guide, p. 21)
For a technician
- With power off, check electrical connections; if the tank leaks, replace the unit. (Electric smart valve guide, p. 21)
-
The anode rod is used up.044 with alert indicator flashing
The anode rod is used up. (Electric smart valve guide, p. 21)
By model: Smart valve manual only.
For a technician
- Check anode circuit (0 ohms) and wiring; then shut cold water, relieve pressure, remove and inspect the anode. (Electric smart valve guide, p. 21)
-
The control’s backup battery is low.045 with an alert indicator flashing.
The control’s backup battery is low. (Electric smart valve guide, p. 21)
By model: Same meaning as 048 on the smart heat pumps. Also in 100341152; not in 100354544.
For a technician
- Remove the battery tray and replace with Panasonic BR2032 or Murata CR2032 only. (Electric smart valve guide, p. 21)
-
The automatic shut-off valve has a problem.046 with an alert indicator flashing.
The automatic shut-off valve has a problem. (Electric smart valve guide, p. 21)
By model: Also in 100341152; not in 100354544.
For a technician
- Power off, close cold water, relieve pressure, check the valve, replace if needed, refill and bleed air. (Electric smart valve guide, p. 21)
-
The Smart Valve failed.047 with alert indicator flashing
The Smart Valve failed. (Electric smart valve guide, p. 21)
By model: Smart valve manual only.
What you can check
- Turn power OFF at the breaker, then back ON, to see if the code clears. (Electric smart valve guide, p. 21)
For a technician
- If it persists, replace the Smart Valve. (Electric smart valve guide, p. 21)
-
The upper thermostat has an error.101 with an alert indicator flashing.
The upper thermostat has an error. (Electric smart valve guide, p. 21)
By model: Smart valve manual only.
For a technician
- Power off, check connections and wiring, replace the thermostat. (Electric smart valve guide, p. 21)
-
The lower thermostat has an error.102 with an alert indicator flashing.
The lower thermostat has an error. (Electric smart valve guide, p. 21)
By model: Smart valve manual only.
For a technician
- Power off, check connections and wiring, replace the thermostat. (Electric smart valve guide, p. 21)
-
The upper element relay is stuck; heating is disabled.103 with an alert indicator flashing.
The upper element relay is stuck; heating is disabled. (Electric smart valve guide, p. 21)
By model: Smart valve manual only.
What you can check
- Turn off power to the water heater and contact technical support. (Electric smart valve guide, p. 21)
-
The lower element relay is stuck; heating is disabled.104 with an alert indicator flashing.
The lower element relay is stuck; heating is disabled. (Electric smart valve guide, p. 21)
By model: Smart valve manual only.
What you can check
- Turn off power to the water heater and contact technical support. (Electric smart valve guide, p. 21)
No A.O. Smith code matches that. Check the number on the display again, or look at the other brands.
Clearing a code
How to reset a A.O. Smith, and when to stop
To clear a code
- Relighting is the reset. Turn the knob to PILOT, hold it in and click the igniter about once a second for up to 90 seconds until the status light flashes once every 3 seconds. If it does not, release the knob and wait 10 minutes before the next try (repeat at least two more times). (Gas tank guide 100263112, p. 23)
- The gas control has built-in circuitry that requires waiting 10 minutes between lighting attempts. (Direct vent tank guide, p. 27)
- Ultra-Low NOx models: after the cause is corrected, the manual’s reset is: knob to OFF, unplug the thermopile plug from the gas control, wait about three minutes, plug it back in, turn the knob to PILOT and restart per the lighting instructions. (Ultra Low NOx tank guide (2015), p. 22)
- Soft lockout: the control waits 20 minutes before returning to normal operation. (Flue damper tank guide, p. 27)
- For ECO and 8-x faults the manual’s reset is: power switch on the gas control to OFF, wait 10-20 seconds, back to ON. (Flue damper tank guide, p. 27)
- LDO module (ULN): burner-failure code clears by pressing and holding the LDO module reset button 3 seconds; lint build-up code needs main power cycled; chamber-sensor code clears by itself once fixed. (Flue damper ULN guide, p. 30)
- Soft lockouts need the gas control reset: slide the ON/OFF switch to OFF, wait 10 seconds, slide it back to ON. If the cause is not fixed, it locks out again. (Power vent manual, p. 54)
- Signature power vent (Lowe’s): same reset - ON/OFF switch to OFF, wait 10 seconds, back to ON. (Signature power vent guide, p. 54)
- Soft lockout lasts 20 minutes; ECO and flammable-vapor lockouts last indefinitely until reset. (Power vent manual, p. 55)
- ECO (4 flashes) cannot be reset by cycling power: turn the set-point knob to its lowest position for at least 10 seconds, then back. This manual reset can only be done 2 times; on the third ECO trip the gas valve goes into hard lockout and must be replaced. (Power direct vent manual, p. 57)
- Most Intelli-Vent codes: turn the power off for 10-20 seconds, then on again. Pattern 6 (ignition lockout) locks out for one hour; cycle power to reset. (Vertex GPHE manual, p. 36)
- ECO high limit: can be reset when the water drops below 140°F (60°C) by turning the heater off for at least 10 seconds with the switch on top, then on. (Vertex GPHE manual, p. 32)
- Reset a lockout by turning off the switch on the front of the unit for about 20 seconds, then back on. If the cause is not fixed it will lock out again. (Vertex 100 manual (series 300), p. 60)
- Service handbook (series 120/121): turn the power supply off for about 20 seconds, then back on. (Vertex service handbook, p. 56 (PDF p. 58))
- Soft faults retry after 15 minutes, or reset immediately with the heater Enable/Disable switch. Lockout reset: turn off the switch on the front for about 20 seconds, then on. (Vertex ULN HDHE manual, p. 64)
- Clear hard and soft faults: unlock the control (hold Lock/Unlock 3 seconds), then press ON/OFF and Plus together for 3 seconds. Soft faults also clear automatically 15 minutes after the condition goes away; auto-reset faults clear by themselves. (Vertex HV guide, p. 56)
- ECO (E00): water must drop below 140°F before reset; then unlock and press ON/OFF and Plus (SW3) together for 3 seconds. A qualified technician should find the cause before resetting. (Vertex HV guide, p. 48)
- Codes marked * in the X3, U, C and CX3 manuals clear when water flow stops (111, 121, 311, 321, 331, 341, 391, 611, 661, 701, 711, 721). (X3 tankless manual, p. 55)
- 111 and 121 automatically reset when water stops moving through the heater, or when power is turned off and back on. (140H tankless service handbook, p. 12)
- Power cycling: turn the power off at the breaker and back on (see 'Power Cycling the Unit'). (Voltex heat pump guide, p. 20)
- Codes marked * may have an audible alarm; press any button on the UIM to cancel it. (Voltex heat pump guide, p. 20)
- Most control-assembly codes: turn power OFF at the breaker, then ON, to see if the code clears. (Voltex MAX guide, p. 25)
A.O. Smith’s safety notes
- WHAT TO DO IF YOU SMELL GAS: do not try to light any appliance; do not touch any electrical switch or use any phone in your building; call your gas supplier from a neighbor’s phone; if you cannot reach them, call the fire department. (Gas tank guide 100263112, p. 1)
- Should overheating occur or the gas supply fail to shut off, turn off the water heater’s manual gas control valve and call a qualified person. (Gas tank guide 100263112, p. 23)
- If the heater stopped and will not relight, check the flame arrestor for blue or black heat discoloration. If a flammable vapor incident is suspected, do not use the heater; call a qualified technician. Heaters exposed to a flammable vapor ignition must be replaced. (ProLine high recovery guide, p. 34)
- Wait 10 minutes between lighting attempts (built-in circuitry requires it). (Direct vent tank guide, p. 27)
- Seven-flash (flammable vapor sensor lockout): do not touch any electrical switch, do not use any phone in the building, and do not try to light any appliance; check for gas leaks and remove any flammable products from the area. (Flue damper tank guide, p. 28)
- ECO manual reset can only be performed 2 times; after the ECO trips a third time the gas valve enters a hard lockout and the gas control must be replaced. (Power direct vent manual, p. 57)
- If the water temperature gets too high (4 flashes), turn the main gas supply OFF and have the water heater repaired by a qualified service technician. (Power vent manual, p. 54)
- Fault condition: the control locks out and the water heater must be serviced by a qualified service technician before operation can be restored. (Vertex 100 manual (series 300), p. 60)
- Energy Cut Out: be extremely careful checking water temperature at a fixture; if above 180°F shut off power and gas, call technical support, and do not leave the heater in operation. (Vertex service handbook, p. 60 (PDF p. 62))
- Jumper wires must never be used on the Blower Prover Switch. (Vertex 100 manual (series 130), p. 57)
- Jumping out control circuits or components can result in property damage, personal injury or death. (Vertex ULN HDHE manual, p. 64)
- Fault 37 screen: the flame-sense rod sees flame when the gas valve should be off. Shut off gas until repaired. (Vertex ULN HDHE manual, p. 68)
- Vertex HV ECO: contact a qualified service technician to determine the reason for ECO activation before resetting it. (Vertex HV guide, p. 48)
- WHAT TO DO IF YOU SMELL GAS: do not try to light any appliance; do not touch any electric switch or use any phone in your building; call your gas supplier from a neighbor’s phone; if you can’t reach them, call the fire department. (ProLine XE tankless manual, p. 1)
- Codes 510/551: if the hot water is shut off but flames are still visible through the sight glass, immediately shut off gas and power to the unit and contact technical service. (140H tankless service handbook, p. 14)
- Code 721: shut off all gas and power to the unit. It could be the flame sensor, but if it isn’t, this is a very dangerous situation. (140H tankless service handbook, p. 16)
- Service handbook procedures must be performed by licensed, qualified service professionals only. (140H tankless service handbook, p. 17)
- Adapt E037 / E384 false flame: if a flame is visible through the sight glass when no water is running, immediately shut off the gas to the water heater and contact a qualified service technician before using it. (Adapt Premium guide, p. 62)
- Adapt troubleshooting table: working on an energized circuit can result in severe injury or death from electrical shock. (Adapt Premium guide, p. 60)
- Heat pump diagnostic codes: Electric shock hazard - disconnect power before servicing; do not remove the plastic guard over wiring or touch electrical wiring. (Voltex heat pump guide, p. 20)
- Control-assembly battery: replace only with Panasonic BR2032 or Murata CR2032; another battery may present a risk of fire or explosion. (Electric smart valve guide, p. 21)
Heater getting old, or the same code keeps coming back? Repair or replace? Three taps and Dan’s answer → Or see what a water heater repair usually involves.
Which one do you have?
The A.O. Smith heaters these codes cover
- Gas tank with a status light (atmospheric or direct vent)GCR/GCB/GCG/GCRL/GCRT/GCBL, XCR/XCB/XCG/XCRL/XCRT, HWR/HWG/HWRL/HWRT, FCG-75/100, PCG-75/100, FMHR-30/40, GDV-40/50, GDVT-50, GDVNL-40L, GDVNT-50L, Signature 100 high recovery (Lowe’s) · Single LED 'status light' on the gas control valve/thermostat; codes are counted flashes. Normal is 1 flash every 3 seconds.
- Ultra Low NOx gas tank with a status lightGUC-30/40/50, GUR-40/50, GURL-40, GURT-50L/50RL, XUC-40, XURT-50L, HUC-40/50, HUR-40/50 · Same single-LED status light as the standard atmospheric family, plus two extra codes (9 and 10 flashes) tied to the combustion-chamber temperature sensor.
- ProLine XE flue damper gas tankGCF-40/50-100/101, GCFL-40/50-100/101 · Single status LED on the gas control valve/thermostat. Idle = short flash every 4 seconds; 'heartbeat' (bright/dim) = heating. Faults are flash counts with a 3-second pause; two-part codes like 'Six-One' = six flashes, one-second pause, one flash.
- ProLine XE Ultra Low NOx flue damper tankGUF-40-100, GUF-50-100 · Same gas-control status LED as fd-xe, plus a second status light on a separate LDO module. If the gas-control LED is dark, read the LDO module light.
- Power vent and power direct vent gas tankGPVL-40/50-200/201, GPVT-40/50(L)-200/201, GPVX-50L-200/201, GPVX-75L-310/311, GPVNT-40/50-100, GPDL-40(L)-300/301, GPDT-50(L)-300/301, GPDX-50L-300/301, GPDX-75L-310/311, GPDNL-40-100, GPDNT-50-100, Signature power vent HSI (Lowe’s) · Single LED on the gas control valve/thermostat. Idle = short flash every 4 seconds; 'heartbeat' (bright/dim) = heating. Fault codes are flash counts with a 3-second pause; 'Six-Two' = six flashes, 1-second pause, two flashes.
- Vertex GPHE-50 (Intelli-Vent lights)GPHE-50-110, GPHE-50-120, GPHE-50-130 · Row of six LEDs on the user control (labeled VAC, ▲, A, B, C) that normally show the temperature setting; a fault shows a fixed pattern of lit LEDs. The manual’s chart numbers the patterns 1-14.
- Vertex 100 GDHE (screen messages)GDHE-50 series 120/121, GDHE-50/75 series 130/131, GDHE-50 series 300/301 (hotwater.com: GDHE-50-141) · Plain-English Fault ('!') or Alert ('?') message on the UIM’s LCD. Series 300/301 screens also show an error code such as 'B2-70'.
- Vertex Ultra Low NOx HDHEHDHE-50-400, HDHE-75-400 · Fault ('!') or Alert ('?') screen on the UIM with a numbered FAULT CODE and a 'Data Error Code' in parentheses, e.g. (202, 70). Tap 'More' for details.
- Vertex HVHPCT-40L-120/121, HPCX-50L-120/121 · E-code shown on the LCD, alternating with the set point (1 second each); warning icon flashes; some codes sound a buzzer.
- ProLine XE tanklessATI/ATO-140H, ATI/ATO-240H, 340H, 540H, ATI/ATO-540P, ATI/ATO-240HX3, 340HX3, 540HX3, ATI/ATO-110U, 310U, 510U, ATI-110C, 310C, 510C, ATI-310CX3, 510CX3 · 3-digit code on the built-in temperature controller (indoor) or remote controller; the green LED on the computer board also flashes a pattern (0.5 s on / 0.5 s off, then 3 s off). In an Easy-Link (multi-unit) system the parent controller alternates the code and the unit number.
- Adapt tanklessATHR-160/180/199 M and X3, ATM-140/160/180/199 M and X3, ATI/ATO-140B/180B/199B and X3 · 'E' plus a 3-digit number with leading zeros on the built-in display (UIM) or remote, e.g. E002. In a cascade system the parent display alternates the heater number and the code.
- Voltex heat pump (letter codes)HPTU-50N/66N/80N-130, HPTU-50CTA/66CTA/80CTA-130, FPTU-50/66/80-130 · Letter/number code on the UIM display (e.g. EUC, E20, Edr). Codes marked * may sound an alarm; press any button to silence it.
- Smart heat pump (3-digit codes)HPTA-40/50/66/80-210, HPTV-50/66/80-210, HPTS-50/66/80-210 · 3-digit code with the alert indicator flashing, plus a flashing red LED (some codes also beep).
- Electric tank with electronic controlPESU/PETU/PELBU, EESU/EETU/EELBU-100, PESX-40/50, PETX-40/50/55, HESFA-40/50, HETFA-40/50/55 · 3-digit code with the alert indicator flashing, plus flashing red LED and beeper.
Common questions
A.O. Smith error code questions
What does it mean when my A.O. Smith water heater blinks?
On a standard gas tank with a status light, one flash every 3 seconds is normal. A set number of flashes, then a pause, is a code: 2 flashes means the thermopile isn’t making enough power, 4 is a high-temperature shutdown, 5 is a failed temperature sensor, 7 is a failed gas control valve, and 8 means the control still sees thermopile power after the knob was turned off. Flue damper and power-vent tanks use different patterns.
What does 7 flashes mean on an A.O. Smith?
It depends on the tank. On a standard gas tank with a status light, 7 flashes means the gas control valve has failed and needs replacing. On flue damper and power-vent tanks, 7 flashes means the flammable vapor sensor found vapors like gasoline, paint or solvents near the heater and locked it out.
What does B2-70 mean on an A.O. Smith Vertex?
Ignition failure. The heater tried to light three times, never saw a flame and locked out. A.O. Smith’s manual says to make sure the main gas shutoff valve is open. After that it’s grounding, the flame sensor, wiring, the vent and gas pressure, which are a technician’s job.
Are A.O. Smith ProLine XE tankless codes the same as Takagi’s?
They use the same three-digit numbering, like 111 for ignition failure and 991 for poor combustion, and many of the same manuals. Check your model’s entry here for its exact meaning.
Where this comes from
Sources
Every meaning, cause and step on this page is from A.O. Smith’s own documents, checked November 13, 2026. Page numbers are the printed page. We left out codes we only found on forums.
- Installation Instructions and Use & Care Guide - Residential Atmospheric Gas Water Heater with the Flammable Vapor Ignition Resistant Safety System (hotwater.com: ProLine Standard Atmospheric Vent Manual) A. O. Smith Corporation · 100263112 · January 2015 (file title BT_STD_ALL_EN_RES-GAS_01092015) · Models: ProLine GCR/GCB/GCG/GCRL/GCRT/GCBL, ProLine XCR/XCB/XCG/XCRL/XCRT, ProLine Master HWR/HWG/HWRL/HWRT, ProLine 35.5k GCR-30/GCRL-30
- Installation Instructions and Use & Care Guide - Atmospheric Vent Ultra Low NOx Gas Water Heater (hotwater.com: Atmospheric Vent Ultra Low Nox Gas Water Heater Manual) A. O. Smith Corporation · 100263190 · January 2015 · Models: ProLine ULN GUC-40-410, GUC-40/50-450, GUR-40/50-450, GURT-50L-450, GURT-50RL-470, XUC-40-450, XURT-50L-450, ProLine Master ULN HUC-40-410
- Installation Instructions and Use & Care Guide - Residential Ultra Low NOx Gas Water Heater (hotwater.com: ProLine Master Ultra-Low NOx Atmospheric Manual) A. O. Smith Corporation · 100347101 · 100347101_2000604771_REV_A, July 2021 · Models: ProLine Master ULN HUC-40/50-450/500, HUR-40/50-450/500, ProLine ULN GUC-30/40/50-500, GUR-40/50-500, GURL-40-500, XUC-40-500
- Installation Instructions and Use & Care Guide - ProLine High Recovery Atmospheric Vent (hotwater.com title) A. O. Smith Corporation · 100276479 · file dated 2016, modified Oct 2023 · Models: ProLine FCG-75/100, FCG-75L, PCG-75/100, PCG-75L
- Installation Instructions and Use & Care Guide - Residential Gas Water Heater for Manufactured Homes (Atmospheric, FVIR) A. O. Smith Corporation · 100307779 · 100307779_2000560245_REV. B, October 2019 · Models: ProLine FMHR-30, FMHR-40 (mobile home atmospheric)
- Installation Instructions and Use & Care Guide - Residential Direct Vented Gas Water Heater with FVIR System A. O. Smith Corporation · 100398943 · October 2025 · Models: ProLine GDV-40/50, GDV-40L/50L, GDVT-50/50L (series 300/301)
- Installation Instructions and Use & Care Guide - ProLine Direct Vent Ultra-Low NOx (hotwater.com title) A. O. Smith Corporation · 100369451 · 100369451_2000626161_REV.A, June 2023 · Models: ProLine GDVNL-40L-100, GDVNT-50L-100
- Installation Instructions and Use & Care Guide - Residential Gas Water Heaters (A. O. Smith Signature 100 Series High Recovery, sold at Lowe’s) A. O. Smith Corporation · 100341468 · 100341468_2000598643_REV_A, March 2021 · Models: A. O. Smith Signature 100 high-recovery gas (Lowe’s)
- Electronic Residential Gas Valve Troubleshooting (one-page training sheet) A. O. Smith Corporation (A. O. Smith University training site) · ElecValve_AOS · March 2016 (file date) · Models: Residential standard atmospheric gas (A. O. Smith University 'Standard Gas' page)
- Installation Instructions and Use & Care Guide - Residential Gas Water Heater with FVIR (flue damper, ProLine XE) A. O. Smith Corporation · 100400765 · November 2025 · Models: ProLine XE GCF-40/50, GCFL-40/50 (series 100/101)
- Installation Instructions and Use & Care Guide - Residential Standard Gas Ultra Low NOx Water Heater (hotwater.com: ProLine XE Ultra-Low NOx Flue Damper Manual) A. O. Smith Corporation · 100366638 · 100366638_2000622614_REV.A, February 2023 · Models: ProLine XE GUF-40-100, GUF-50-100
- Instruction Manual - Residential Gas Water Heaters, Power Vented Gas Models with Hot Surface Ignition (hotwater.com: ProLine XE Power Vent 40/50 Gal Manual) A. O. Smith Corporation · 100366731 · 100366731_2000622624_REV.A, February 2023 · Models: ProLine XE GPVL-40/50, GPVT-40/50, GPVT-40L/50L, GPVX-50L (series 200/201)
- Instruction Manual - ProLine XE Power Vent (75 gallon) (hotwater.com title) A. O. Smith Corporation · 100271598 · 100271598_2000195582_Rev. B · Models: ProLine XE GPVX-75L-310/311
- Power Vented Ultra Low NOx Gas Water Heater - Use and Care Guide (hotwater.com: Residential Power Vent Ultra Low Nox Gas Water Heater with FVIR) A. O. Smith Corporation · 100362953 · March 2023 (printed 7/6/2023) · Models: ProLine XE GPVNT-40-100, GPVNT-50-100
- Instruction Manual - Power Direct Vent Gas Models with Hot Surface Ignition A. O. Smith Corporation · 100366639 · 100366639_2000622618_REV.A, February 2023 · Models: ProLine XE GPDL-40/40L, GPDT-50/50L, GPDX-50L (series 300/301)
- Instruction Manual - ProLine XE Ultra-Low NOx Power Direct-Vent (hotwater.com title) A. O. Smith Corporation · 100366712 · February 2023 · Models: ProLine XE GPDNL-40-100, GPDNT-50-100
- Instruction Manual - ProLine Power Direct-Vent (75 gallon) (hotwater.com title) A. O. Smith Corporation · 100228349 · file dated March 2017 · Models: ProLine XE GPDX-75L-310/311
- Installation Instruction and Use & Care Guide - Residential Gas Water Heaters, Power Vented Gas Models with Hot Surface Ignition (A. O. Smith Signature, sold at Lowe’s) A. O. Smith Corporation · 100341461 · March 2021 · Models: A. O. Smith Signature power vent gas (Lowe’s)
- Instruction Manual - Residential Gas Water Heaters, Power Vented Gas Models w/Hot Surface Ignition (hotwater.com: Vertex Power Vent GPHE 50 Manual) A. O. Smith Corporation · 100341945 · 100341945_2000542152E (file modified April 2021) · Models: Vertex / ProLine XE GPHE-50-110/120/130
- Service Handbook - Commercial / Residential Gas Water Heater, Models BTX 100, GDHE 50, Series 120 & 121 A. O. Smith Corporation · 318556-000 · Printed 0410 (April 2010) · Models: Vertex 100 GDHE-50 series 120/121 (and commercial BTX-100)
- Instruction Manual - Residential Gas Water Heaters, Power Vent/Power Direct Vent Gas Models with Direct Spark Ignition, Models GDHE-50/GDHE-75 Series 130/131 A. O. Smith Corporation · 326459-000 · file dated January 2014 · Models: Vertex 100 GDHE-50, GDHE-75 series 130/131
- Instruction Manual - Residential Gas Water Heaters, Power Vent/Power Direct Vent Gas Models with Direct Spark Ignition, 300/301 Series Models (hotwater.com: Vertex 100 Power Direct Vent Manual) A. O. Smith Corporation · 100313413 · 100313413_2000556971_Rev C, printed 0219 · Models: Vertex 100 GDHE-50 (series 300/301; hotwater.com lists it for GDHE-50-141)
- Instruction Manual - Residential Gas Water Heaters, Power Vent/Power Direct Vent Gas Models with Direct Spark Ignition, Models 50/75 Gallon Series 400/401 (hotwater.com: Vertex Ultra-Low NOx Power Direct Manual) A. O. Smith Corporation · 100348176 · 100348176_2000605694 A · Models: Vertex HDHE-50-400, HDHE-75-400 (series 400/401)
- Installation Instructions and Use and Care Guide - Residential Condensing Gas Water Heaters (hotwater.com: Vertex HV Manual) A. O. Smith Corporation · 100368549 · 100368549_2000624920B (file modified July 2024) · Models: Vertex HV HPCT-40L-120/121, HPCX-50L-120/121
- On-Demand Water Heater Installation Manual and Owner’s Guide - Models 240, 340, 540 (hotwater.com: ProLine XE Tankless High Efficiency manual) A. O. Smith Corporation · 2000534710 · Models: ATI-240H/340H/540H (indoor), ATO-240H/340H/540H (outdoor), hotwater.com also links it for ATI/ATO-140H
- Condensing Models On-Demand Water Heater Service Handbook (Models ATI-140H-N/P, ATO-140H-N/P; also lists GTS-140, GT-140 and T-H3M) A. O. Smith Corporation · 100267626 · January 2016 · Models: ATI-140H-N/P, ATO-140H-N/P
- On-Demand Water Heater Installation Manual and Owner’s Guide - 540P (Tankless High Efficiency Condensing with recirculation pump) A. O. Smith Corporation · 2000536265 · Models: ATI-540P-N/P, ATO-540P-N
- On-Demand Water Heater Installation Manual and Owner’s Guide - ProLine XE Condensing Tankless with X3 Scale Prevention Technology A. O. Smith Corporation · 2000599585 · 2000599585 (Rev. B) · Models: ATI/ATO-240HX3, 340HX3, 540HX3
- On-Demand Water Heater Installation Manual and Owner’s Guide - Models 110C, 310C, 510C (Tankless Non-Condensing Concentric Vent) A. O. Smith Corporation · 2000535218 · Models: ATI-110C, ATI-310C, ATI-510C
- On-Demand Water Heater Installation Manual and Owner’s Guide - Models 110U, 310U, 510U (Tankless Non-Condensing Ultra-Low NOx) A. O. Smith Corporation · 100269776 · Models: ATI/ATO-110U, 310U, 510U
- On-Demand Water Heater Installation Manual and Owner’s Guide - Models 310CX3, 510CX3 Series 110 (Non-Condensing Concentric Vent with X3) A. O. Smith Corporation · 2000610429 · Models: ATI-310CX3-110, ATI-510CX3-110
- Installation Instructions and Use & Care Guide - ADAPT Residential Gas Tankless Water Heaters (Adapt+ Premium Condensing) A. O. Smith Corporation · 2000628591 · file modified August 2024 · Models: Adapt+ Premium ATHR-160M/180M/199M, ATHR-160X3/180X3/199X3
- Installation Instructions and Use & Care Guide - Standard Condensing Residential Gas Tankless Water Heater (Adapt SC) A. O. Smith Corporation · 100402901 · 100402901_2000856682 · Models: Adapt SC ATM-140M/160M/180M/199M, ATM-140X3/160X3/180X3/199X3
- Installation Instructions and Use & Care Guide - Non-Condensing Residential Gas Tankless Water Heater (Adapt NC) A. O. Smith Corporation · 100385425 · 100385425_2000839619 · Models: Adapt NC ATI/ATO-140B/180B/199B, ATI/ATO-140X3/180X3/199X3
- Installation Instructions and Use & Care Guide - Hybrid Electric Heat Pump Water Heater (hotwater.com: Voltex Hybrid Electric Heat Pump Manual) A. O. Smith Corporation · 100323093 · 100323093_2000578009, September 2019 · Models: Voltex HPTU-50N/66N/80N-130, Voltex XE HPTU-50CTA/66CTA/80CTA-130
- Installation Instructions and Use & Care Guide - Hybrid Electric Heat Pump Water Heater (hotwater.com: Voltex XE - 6yr Heat Pump) A. O. Smith Corporation · 100264133 · April 2015 · Models: Voltex FPTU-50/66/80-130
- Installation Instructions and Use & Care Guide - Hybrid Electric Heat Pump Water Heater (hotwater.com: Voltex MAX Smart Heat Pump with Premium Smart Valve Technology Manual) A. O. Smith Corporation · 100379654 · 100379654_2000812401, March 2025 · Models: Voltex MAX HPTA-40/50/66/80-210
- Installation Instructions and Use & Care Guide - Hybrid Electric Heat Pump Water Heater (hotwater.com: 120V Plug-In Hybrid Electric Heat Pump Manual) A. O. Smith Corporation · 100379653 · 100379653_2000812406, March 2025 · Models: Voltex 120 HPTV-50/66/80-210
- Installation Instructions and Use & Care Guide - Hybrid Electric Heat Pump Water Heater (hotwater.com: Smart AL Hybrid Electric Heat Pump Manual) A. O. Smith Corporation · 100379659 · 100379659_2000812395, March 2025 · Models: Voltex XE AL Smart HPTS-50/66/80-210
- Hybrid Electric Heat Pump Water Heater Installation Instructions and Use & Care Guide Addendum A. O. Smith Corporation · 100392298 · Models: HPTA, HPTS, HPTV (linked from those product pages)
- Installation Instructions and Use & Care Guide - Residential Electronic Thermostat Electric Water Heater (hotwater.com: ProLine Grid-Capable Electric Manual) A. O. Smith Corporation · 100354544 · 100354544_2000609845, January 2022 · Models: ProLine grid-capable PESU/PETU/PELBU, EESU/EETU/EELBU (series 100)
- Installation Instructions and Use & Care Guide - Residential Electronic Thermostat Electric Water Heater (hotwater.com: ProLine Smart Electric Grid-Capable Manual) A. O. Smith Corporation · 100376565 · 100376565_2000804829, January 2024 · Models: ProLine XE smart valve PESX-40/50, PETX-40/50/55
- Installation Instructions and Use & Care Guide - Residential Electronic Thermostat Electric Water Heater (hotwater.com: ProLine Master Smart Electric Grid Capable Manual) A. O. Smith Corporation · 100341152 · 100341152_2000598247, October 2022 · Models: ProLine Master smart HESFA-40/50, HETFA-40/50/55
Other brands
Error codes for other water heaters
Water heater help
More about water heaters
Code won’t clear?
If you’re within about 30 miles of Westlake Village, call or text Dan a photo of the display and the label. He’ll tell you what it is.
Or send the details and Dan will call you back. Monday to Friday, 9am – 5pm.