Gas tanks, Vertex, tankless and heat pumps · 272 codes · Checked November 2026

A.O. Smith error codes, in plain words

A.O. Smith gas tanks talk through a status light that flashes a count. Power-vent and Vertex models show patterns or messages, and the tankless and heat pump models show number codes. Here’s every code in A.O. Smith’s manuals, in plain words. The same count means different things on different tanks, so start with what you have.

Dan and Dave of Dan's Plumbing in front of their work truck

From Dan and Dave at Dan's Plumbing, a family plumbing shop in Westlake Village, California. Every line below comes from A.O. Smith’s own documents, with the page it’s on.

The gas control at the bottom of a tank water heater, with its status light. Below it, the light's pattern: 7 blinks, then a pause, over and over. STATUS LIGHT PAUSE · REPEAT
Standard gas tank: count the flashes of the status light on the gas control, from one pause to the next. One flash every 3 seconds is normal. Vertex: a message on the screen. Tankless and heat pump: a number on the display.

Smell gas? Don’t touch any switch or try to reset anything. Leave the house, then call 911 or your gas company from outside. In Southern California that’s SoCalGas, 1-800-427-2200.

Every code

All 272 A.O. Smith codes

Gas tanks with a status light

Standard and Ultra Low NOx atmospheric and direct-vent tanks. One flash every 3 seconds is normal. Other counts are codes.

Flue damper gas tanks (ProLine XE)

Plug-in tanks with a damper on the vent. The light uses different patterns, and Ultra Low NOx models add a second light on the LDO module.

Power vent and power direct vent gas tanks

A fan on top and a hot surface igniter. Same idea, different patterns: count the flashes, and for 6 and 8 count the second set too.

Vertex condensing gas tanks

Vertex GPHE (a row of lights), Vertex 100 GDHE and Ultra Low NOx HDHE (a message on the screen), and Vertex HV (an E code).

ProLine XE tankless

Three-digit codes like 111 and 991 on the controller or the remote.

Adapt tankless

An E and three digits, like E002, on the display or the remote.

Heat pump and electric tanks

Voltex and other hybrid heat pumps, and electric tanks with an electronic control.

No A.O. Smith code matches that. Check the number on the display again, or look at the other brands.

Clearing a code

How to reset a A.O. Smith, and when to stop

To clear a code

  • Relighting is the reset. Turn the knob to PILOT, hold it in and click the igniter about once a second for up to 90 seconds until the status light flashes once every 3 seconds. If it does not, release the knob and wait 10 minutes before the next try (repeat at least two more times). (Gas tank guide 100263112, p. 23)
  • The gas control has built-in circuitry that requires waiting 10 minutes between lighting attempts. (Direct vent tank guide, p. 27)
  • Ultra-Low NOx models: after the cause is corrected, the manual’s reset is: knob to OFF, unplug the thermopile plug from the gas control, wait about three minutes, plug it back in, turn the knob to PILOT and restart per the lighting instructions. (Ultra Low NOx tank guide (2015), p. 22)
  • Soft lockout: the control waits 20 minutes before returning to normal operation. (Flue damper tank guide, p. 27)
  • For ECO and 8-x faults the manual’s reset is: power switch on the gas control to OFF, wait 10-20 seconds, back to ON. (Flue damper tank guide, p. 27)
  • LDO module (ULN): burner-failure code clears by pressing and holding the LDO module reset button 3 seconds; lint build-up code needs main power cycled; chamber-sensor code clears by itself once fixed. (Flue damper ULN guide, p. 30)
  • Soft lockouts need the gas control reset: slide the ON/OFF switch to OFF, wait 10 seconds, slide it back to ON. If the cause is not fixed, it locks out again. (Power vent manual, p. 54)
  • Signature power vent (Lowe’s): same reset - ON/OFF switch to OFF, wait 10 seconds, back to ON. (Signature power vent guide, p. 54)
  • Soft lockout lasts 20 minutes; ECO and flammable-vapor lockouts last indefinitely until reset. (Power vent manual, p. 55)
  • ECO (4 flashes) cannot be reset by cycling power: turn the set-point knob to its lowest position for at least 10 seconds, then back. This manual reset can only be done 2 times; on the third ECO trip the gas valve goes into hard lockout and must be replaced. (Power direct vent manual, p. 57)
  • Most Intelli-Vent codes: turn the power off for 10-20 seconds, then on again. Pattern 6 (ignition lockout) locks out for one hour; cycle power to reset. (Vertex GPHE manual, p. 36)
  • ECO high limit: can be reset when the water drops below 140°F (60°C) by turning the heater off for at least 10 seconds with the switch on top, then on. (Vertex GPHE manual, p. 32)
  • Reset a lockout by turning off the switch on the front of the unit for about 20 seconds, then back on. If the cause is not fixed it will lock out again. (Vertex 100 manual (series 300), p. 60)
  • Service handbook (series 120/121): turn the power supply off for about 20 seconds, then back on. (Vertex service handbook, p. 56 (PDF p. 58))
  • Soft faults retry after 15 minutes, or reset immediately with the heater Enable/Disable switch. Lockout reset: turn off the switch on the front for about 20 seconds, then on. (Vertex ULN HDHE manual, p. 64)
  • Clear hard and soft faults: unlock the control (hold Lock/Unlock 3 seconds), then press ON/OFF and Plus together for 3 seconds. Soft faults also clear automatically 15 minutes after the condition goes away; auto-reset faults clear by themselves. (Vertex HV guide, p. 56)
  • ECO (E00): water must drop below 140°F before reset; then unlock and press ON/OFF and Plus (SW3) together for 3 seconds. A qualified technician should find the cause before resetting. (Vertex HV guide, p. 48)
  • Codes marked * in the X3, U, C and CX3 manuals clear when water flow stops (111, 121, 311, 321, 331, 341, 391, 611, 661, 701, 711, 721). (X3 tankless manual, p. 55)
  • 111 and 121 automatically reset when water stops moving through the heater, or when power is turned off and back on. (140H tankless service handbook, p. 12)
  • Power cycling: turn the power off at the breaker and back on (see 'Power Cycling the Unit'). (Voltex heat pump guide, p. 20)
  • Codes marked * may have an audible alarm; press any button on the UIM to cancel it. (Voltex heat pump guide, p. 20)
  • Most control-assembly codes: turn power OFF at the breaker, then ON, to see if the code clears. (Voltex MAX guide, p. 25)

A.O. Smith’s safety notes

  • WHAT TO DO IF YOU SMELL GAS: do not try to light any appliance; do not touch any electrical switch or use any phone in your building; call your gas supplier from a neighbor’s phone; if you cannot reach them, call the fire department. (Gas tank guide 100263112, p. 1)
  • Should overheating occur or the gas supply fail to shut off, turn off the water heater’s manual gas control valve and call a qualified person. (Gas tank guide 100263112, p. 23)
  • If the heater stopped and will not relight, check the flame arrestor for blue or black heat discoloration. If a flammable vapor incident is suspected, do not use the heater; call a qualified technician. Heaters exposed to a flammable vapor ignition must be replaced. (ProLine high recovery guide, p. 34)
  • Wait 10 minutes between lighting attempts (built-in circuitry requires it). (Direct vent tank guide, p. 27)
  • Seven-flash (flammable vapor sensor lockout): do not touch any electrical switch, do not use any phone in the building, and do not try to light any appliance; check for gas leaks and remove any flammable products from the area. (Flue damper tank guide, p. 28)
  • ECO manual reset can only be performed 2 times; after the ECO trips a third time the gas valve enters a hard lockout and the gas control must be replaced. (Power direct vent manual, p. 57)
  • If the water temperature gets too high (4 flashes), turn the main gas supply OFF and have the water heater repaired by a qualified service technician. (Power vent manual, p. 54)
  • Fault condition: the control locks out and the water heater must be serviced by a qualified service technician before operation can be restored. (Vertex 100 manual (series 300), p. 60)
  • Energy Cut Out: be extremely careful checking water temperature at a fixture; if above 180°F shut off power and gas, call technical support, and do not leave the heater in operation. (Vertex service handbook, p. 60 (PDF p. 62))
  • Jumper wires must never be used on the Blower Prover Switch. (Vertex 100 manual (series 130), p. 57)
  • Jumping out control circuits or components can result in property damage, personal injury or death. (Vertex ULN HDHE manual, p. 64)
  • Fault 37 screen: the flame-sense rod sees flame when the gas valve should be off. Shut off gas until repaired. (Vertex ULN HDHE manual, p. 68)
  • Vertex HV ECO: contact a qualified service technician to determine the reason for ECO activation before resetting it. (Vertex HV guide, p. 48)
  • WHAT TO DO IF YOU SMELL GAS: do not try to light any appliance; do not touch any electric switch or use any phone in your building; call your gas supplier from a neighbor’s phone; if you can’t reach them, call the fire department. (ProLine XE tankless manual, p. 1)
  • Codes 510/551: if the hot water is shut off but flames are still visible through the sight glass, immediately shut off gas and power to the unit and contact technical service. (140H tankless service handbook, p. 14)
  • Code 721: shut off all gas and power to the unit. It could be the flame sensor, but if it isn’t, this is a very dangerous situation. (140H tankless service handbook, p. 16)
  • Service handbook procedures must be performed by licensed, qualified service professionals only. (140H tankless service handbook, p. 17)
  • Adapt E037 / E384 false flame: if a flame is visible through the sight glass when no water is running, immediately shut off the gas to the water heater and contact a qualified service technician before using it. (Adapt Premium guide, p. 62)
  • Adapt troubleshooting table: working on an energized circuit can result in severe injury or death from electrical shock. (Adapt Premium guide, p. 60)
  • Heat pump diagnostic codes: Electric shock hazard - disconnect power before servicing; do not remove the plastic guard over wiring or touch electrical wiring. (Voltex heat pump guide, p. 20)
  • Control-assembly battery: replace only with Panasonic BR2032 or Murata CR2032; another battery may present a risk of fire or explosion. (Electric smart valve guide, p. 21)

Heater getting old, or the same code keeps coming back? Repair or replace? Three taps and Dan’s answer → Or see what a water heater repair usually involves.

Which one do you have?

The A.O. Smith heaters these codes cover

Common questions

A.O. Smith error code questions

What does it mean when my A.O. Smith water heater blinks?

On a standard gas tank with a status light, one flash every 3 seconds is normal. A set number of flashes, then a pause, is a code: 2 flashes means the thermopile isn’t making enough power, 4 is a high-temperature shutdown, 5 is a failed temperature sensor, 7 is a failed gas control valve, and 8 means the control still sees thermopile power after the knob was turned off. Flue damper and power-vent tanks use different patterns.

What does 7 flashes mean on an A.O. Smith?

It depends on the tank. On a standard gas tank with a status light, 7 flashes means the gas control valve has failed and needs replacing. On flue damper and power-vent tanks, 7 flashes means the flammable vapor sensor found vapors like gasoline, paint or solvents near the heater and locked it out.

What does B2-70 mean on an A.O. Smith Vertex?

Ignition failure. The heater tried to light three times, never saw a flame and locked out. A.O. Smith’s manual says to make sure the main gas shutoff valve is open. After that it’s grounding, the flame sensor, wiring, the vent and gas pressure, which are a technician’s job.

Are A.O. Smith ProLine XE tankless codes the same as Takagi’s?

They use the same three-digit numbering, like 111 for ignition failure and 991 for poor combustion, and many of the same manuals. Check your model’s entry here for its exact meaning.

Where this comes from

Sources

Every meaning, cause and step on this page is from A.O. Smith’s own documents, checked November 13, 2026. Page numbers are the printed page. We left out codes we only found on forums.

  1. Installation Instructions and Use & Care Guide - Residential Atmospheric Gas Water Heater with the Flammable Vapor Ignition Resistant Safety System (hotwater.com: ProLine Standard Atmospheric Vent Manual) A. O. Smith Corporation · 100263112 · January 2015 (file title BT_STD_ALL_EN_RES-GAS_01092015) · Models: ProLine GCR/GCB/GCG/GCRL/GCRT/GCBL, ProLine XCR/XCB/XCG/XCRL/XCRT, ProLine Master HWR/HWG/HWRL/HWRT, ProLine 35.5k GCR-30/GCRL-30
  2. Installation Instructions and Use & Care Guide - Atmospheric Vent Ultra Low NOx Gas Water Heater (hotwater.com: Atmospheric Vent Ultra Low Nox Gas Water Heater Manual) A. O. Smith Corporation · 100263190 · January 2015 · Models: ProLine ULN GUC-40-410, GUC-40/50-450, GUR-40/50-450, GURT-50L-450, GURT-50RL-470, XUC-40-450, XURT-50L-450, ProLine Master ULN HUC-40-410
  3. Installation Instructions and Use & Care Guide - Residential Ultra Low NOx Gas Water Heater (hotwater.com: ProLine Master Ultra-Low NOx Atmospheric Manual) A. O. Smith Corporation · 100347101 · 100347101_2000604771_REV_A, July 2021 · Models: ProLine Master ULN HUC-40/50-450/500, HUR-40/50-450/500, ProLine ULN GUC-30/40/50-500, GUR-40/50-500, GURL-40-500, XUC-40-500
  4. Installation Instructions and Use & Care Guide - ProLine High Recovery Atmospheric Vent (hotwater.com title) A. O. Smith Corporation · 100276479 · file dated 2016, modified Oct 2023 · Models: ProLine FCG-75/100, FCG-75L, PCG-75/100, PCG-75L
  5. Installation Instructions and Use & Care Guide - Residential Gas Water Heater for Manufactured Homes (Atmospheric, FVIR) A. O. Smith Corporation · 100307779 · 100307779_2000560245_REV. B, October 2019 · Models: ProLine FMHR-30, FMHR-40 (mobile home atmospheric)
  6. Installation Instructions and Use & Care Guide - Residential Direct Vented Gas Water Heater with FVIR System A. O. Smith Corporation · 100398943 · October 2025 · Models: ProLine GDV-40/50, GDV-40L/50L, GDVT-50/50L (series 300/301)
  7. Installation Instructions and Use & Care Guide - ProLine Direct Vent Ultra-Low NOx (hotwater.com title) A. O. Smith Corporation · 100369451 · 100369451_2000626161_REV.A, June 2023 · Models: ProLine GDVNL-40L-100, GDVNT-50L-100
  8. Installation Instructions and Use & Care Guide - Residential Gas Water Heaters (A. O. Smith Signature 100 Series High Recovery, sold at Lowe’s) A. O. Smith Corporation · 100341468 · 100341468_2000598643_REV_A, March 2021 · Models: A. O. Smith Signature 100 high-recovery gas (Lowe’s)
  9. Electronic Residential Gas Valve Troubleshooting (one-page training sheet) A. O. Smith Corporation (A. O. Smith University training site) · ElecValve_AOS · March 2016 (file date) · Models: Residential standard atmospheric gas (A. O. Smith University 'Standard Gas' page)
  10. Installation Instructions and Use & Care Guide - Residential Gas Water Heater with FVIR (flue damper, ProLine XE) A. O. Smith Corporation · 100400765 · November 2025 · Models: ProLine XE GCF-40/50, GCFL-40/50 (series 100/101)
  11. Installation Instructions and Use & Care Guide - Residential Standard Gas Ultra Low NOx Water Heater (hotwater.com: ProLine XE Ultra-Low NOx Flue Damper Manual) A. O. Smith Corporation · 100366638 · 100366638_2000622614_REV.A, February 2023 · Models: ProLine XE GUF-40-100, GUF-50-100
  12. Instruction Manual - Residential Gas Water Heaters, Power Vented Gas Models with Hot Surface Ignition (hotwater.com: ProLine XE Power Vent 40/50 Gal Manual) A. O. Smith Corporation · 100366731 · 100366731_2000622624_REV.A, February 2023 · Models: ProLine XE GPVL-40/50, GPVT-40/50, GPVT-40L/50L, GPVX-50L (series 200/201)
  13. Instruction Manual - ProLine XE Power Vent (75 gallon) (hotwater.com title) A. O. Smith Corporation · 100271598 · 100271598_2000195582_Rev. B · Models: ProLine XE GPVX-75L-310/311
  14. Power Vented Ultra Low NOx Gas Water Heater - Use and Care Guide (hotwater.com: Residential Power Vent Ultra Low Nox Gas Water Heater with FVIR) A. O. Smith Corporation · 100362953 · March 2023 (printed 7/6/2023) · Models: ProLine XE GPVNT-40-100, GPVNT-50-100
  15. Instruction Manual - Power Direct Vent Gas Models with Hot Surface Ignition A. O. Smith Corporation · 100366639 · 100366639_2000622618_REV.A, February 2023 · Models: ProLine XE GPDL-40/40L, GPDT-50/50L, GPDX-50L (series 300/301)
  16. Instruction Manual - ProLine XE Ultra-Low NOx Power Direct-Vent (hotwater.com title) A. O. Smith Corporation · 100366712 · February 2023 · Models: ProLine XE GPDNL-40-100, GPDNT-50-100
  17. Instruction Manual - ProLine Power Direct-Vent (75 gallon) (hotwater.com title) A. O. Smith Corporation · 100228349 · file dated March 2017 · Models: ProLine XE GPDX-75L-310/311
  18. Installation Instruction and Use & Care Guide - Residential Gas Water Heaters, Power Vented Gas Models with Hot Surface Ignition (A. O. Smith Signature, sold at Lowe’s) A. O. Smith Corporation · 100341461 · March 2021 · Models: A. O. Smith Signature power vent gas (Lowe’s)
  19. Instruction Manual - Residential Gas Water Heaters, Power Vented Gas Models w/Hot Surface Ignition (hotwater.com: Vertex Power Vent GPHE 50 Manual) A. O. Smith Corporation · 100341945 · 100341945_2000542152E (file modified April 2021) · Models: Vertex / ProLine XE GPHE-50-110/120/130
  20. Service Handbook - Commercial / Residential Gas Water Heater, Models BTX 100, GDHE 50, Series 120 & 121 A. O. Smith Corporation · 318556-000 · Printed 0410 (April 2010) · Models: Vertex 100 GDHE-50 series 120/121 (and commercial BTX-100)
  21. Instruction Manual - Residential Gas Water Heaters, Power Vent/Power Direct Vent Gas Models with Direct Spark Ignition, Models GDHE-50/GDHE-75 Series 130/131 A. O. Smith Corporation · 326459-000 · file dated January 2014 · Models: Vertex 100 GDHE-50, GDHE-75 series 130/131
  22. Instruction Manual - Residential Gas Water Heaters, Power Vent/Power Direct Vent Gas Models with Direct Spark Ignition, 300/301 Series Models (hotwater.com: Vertex 100 Power Direct Vent Manual) A. O. Smith Corporation · 100313413 · 100313413_2000556971_Rev C, printed 0219 · Models: Vertex 100 GDHE-50 (series 300/301; hotwater.com lists it for GDHE-50-141)
  23. Instruction Manual - Residential Gas Water Heaters, Power Vent/Power Direct Vent Gas Models with Direct Spark Ignition, Models 50/75 Gallon Series 400/401 (hotwater.com: Vertex Ultra-Low NOx Power Direct Manual) A. O. Smith Corporation · 100348176 · 100348176_2000605694 A · Models: Vertex HDHE-50-400, HDHE-75-400 (series 400/401)
  24. Installation Instructions and Use and Care Guide - Residential Condensing Gas Water Heaters (hotwater.com: Vertex HV Manual) A. O. Smith Corporation · 100368549 · 100368549_2000624920B (file modified July 2024) · Models: Vertex HV HPCT-40L-120/121, HPCX-50L-120/121
  25. On-Demand Water Heater Installation Manual and Owner’s Guide - Models 240, 340, 540 (hotwater.com: ProLine XE Tankless High Efficiency manual) A. O. Smith Corporation · 2000534710 · Models: ATI-240H/340H/540H (indoor), ATO-240H/340H/540H (outdoor), hotwater.com also links it for ATI/ATO-140H
  26. Condensing Models On-Demand Water Heater Service Handbook (Models ATI-140H-N/P, ATO-140H-N/P; also lists GTS-140, GT-140 and T-H3M) A. O. Smith Corporation · 100267626 · January 2016 · Models: ATI-140H-N/P, ATO-140H-N/P
  27. On-Demand Water Heater Installation Manual and Owner’s Guide - 540P (Tankless High Efficiency Condensing with recirculation pump) A. O. Smith Corporation · 2000536265 · Models: ATI-540P-N/P, ATO-540P-N
  28. On-Demand Water Heater Installation Manual and Owner’s Guide - ProLine XE Condensing Tankless with X3 Scale Prevention Technology A. O. Smith Corporation · 2000599585 · 2000599585 (Rev. B) · Models: ATI/ATO-240HX3, 340HX3, 540HX3
  29. On-Demand Water Heater Installation Manual and Owner’s Guide - Models 110C, 310C, 510C (Tankless Non-Condensing Concentric Vent) A. O. Smith Corporation · 2000535218 · Models: ATI-110C, ATI-310C, ATI-510C
  30. On-Demand Water Heater Installation Manual and Owner’s Guide - Models 110U, 310U, 510U (Tankless Non-Condensing Ultra-Low NOx) A. O. Smith Corporation · 100269776 · Models: ATI/ATO-110U, 310U, 510U
  31. On-Demand Water Heater Installation Manual and Owner’s Guide - Models 310CX3, 510CX3 Series 110 (Non-Condensing Concentric Vent with X3) A. O. Smith Corporation · 2000610429 · Models: ATI-310CX3-110, ATI-510CX3-110
  32. Installation Instructions and Use & Care Guide - ADAPT Residential Gas Tankless Water Heaters (Adapt+ Premium Condensing) A. O. Smith Corporation · 2000628591 · file modified August 2024 · Models: Adapt+ Premium ATHR-160M/180M/199M, ATHR-160X3/180X3/199X3
  33. Installation Instructions and Use & Care Guide - Standard Condensing Residential Gas Tankless Water Heater (Adapt SC) A. O. Smith Corporation · 100402901 · 100402901_2000856682 · Models: Adapt SC ATM-140M/160M/180M/199M, ATM-140X3/160X3/180X3/199X3
  34. Installation Instructions and Use & Care Guide - Non-Condensing Residential Gas Tankless Water Heater (Adapt NC) A. O. Smith Corporation · 100385425 · 100385425_2000839619 · Models: Adapt NC ATI/ATO-140B/180B/199B, ATI/ATO-140X3/180X3/199X3
  35. Installation Instructions and Use & Care Guide - Hybrid Electric Heat Pump Water Heater (hotwater.com: Voltex Hybrid Electric Heat Pump Manual) A. O. Smith Corporation · 100323093 · 100323093_2000578009, September 2019 · Models: Voltex HPTU-50N/66N/80N-130, Voltex XE HPTU-50CTA/66CTA/80CTA-130
  36. Installation Instructions and Use & Care Guide - Hybrid Electric Heat Pump Water Heater (hotwater.com: Voltex XE - 6yr Heat Pump) A. O. Smith Corporation · 100264133 · April 2015 · Models: Voltex FPTU-50/66/80-130
  37. Installation Instructions and Use & Care Guide - Hybrid Electric Heat Pump Water Heater (hotwater.com: Voltex MAX Smart Heat Pump with Premium Smart Valve Technology Manual) A. O. Smith Corporation · 100379654 · 100379654_2000812401, March 2025 · Models: Voltex MAX HPTA-40/50/66/80-210
  38. Installation Instructions and Use & Care Guide - Hybrid Electric Heat Pump Water Heater (hotwater.com: 120V Plug-In Hybrid Electric Heat Pump Manual) A. O. Smith Corporation · 100379653 · 100379653_2000812406, March 2025 · Models: Voltex 120 HPTV-50/66/80-210
  39. Installation Instructions and Use & Care Guide - Hybrid Electric Heat Pump Water Heater (hotwater.com: Smart AL Hybrid Electric Heat Pump Manual) A. O. Smith Corporation · 100379659 · 100379659_2000812395, March 2025 · Models: Voltex XE AL Smart HPTS-50/66/80-210
  40. Hybrid Electric Heat Pump Water Heater Installation Instructions and Use & Care Guide Addendum A. O. Smith Corporation · 100392298 · Models: HPTA, HPTS, HPTV (linked from those product pages)
  41. Installation Instructions and Use & Care Guide - Residential Electronic Thermostat Electric Water Heater (hotwater.com: ProLine Grid-Capable Electric Manual) A. O. Smith Corporation · 100354544 · 100354544_2000609845, January 2022 · Models: ProLine grid-capable PESU/PETU/PELBU, EESU/EETU/EELBU (series 100)
  42. Installation Instructions and Use & Care Guide - Residential Electronic Thermostat Electric Water Heater (hotwater.com: ProLine Smart Electric Grid-Capable Manual) A. O. Smith Corporation · 100376565 · 100376565_2000804829, January 2024 · Models: ProLine XE smart valve PESX-40/50, PETX-40/50/55
  43. Installation Instructions and Use & Care Guide - Residential Electronic Thermostat Electric Water Heater (hotwater.com: ProLine Master Smart Electric Grid Capable Manual) A. O. Smith Corporation · 100341152 · 100341152_2000598247, October 2022 · Models: ProLine Master smart HESFA-40/50, HETFA-40/50/55

Other brands

Error codes for other water heaters

Water heater help

More about water heaters

Dan standing in front of his white work truck, smiling

Code won’t clear?

If you’re within about 30 miles of Westlake Village, call or text Dan a photo of the display and the label. He’ll tell you what it is.

Or send the details and Dan will call you back. Monday to Friday, 9am – 5pm.

Find us

Dan's Plumbing

2352 Hillsbury Rd
Westlake Village, CA 91361

(805) 330-3111 · Monday to Friday, 9am – 5pm

Serving Westlake Village, Thousand Oaks, Agoura Hills, Oak Park and Lake Sherwood. Zip codes 91361, 91362, 91360, 91320, 91301, 91377, 91302, 90265.

Dan (left) and Dave. Family run since 1977. One of them does the work.