Rheem · Error code 12 · Checked November 2026
Rheem tankless error code 12: the flame keeps going out
The burner lit, then the flame went out three times in a row. The gas supply comes first, including a propane tank running low.
Smell gas? Don’t touch any switch or try to reset anything. Leave the house, then call 911 or your gas company from outside. In Southern California that’s SoCalGas, 1-800-427-2200.
From Dan and Dave at Dan's Plumbing, a family plumbing shop in Westlake Village, California. Everything below comes from Rheem’s own documents, cited line by line.
What it means
What Rheem says code 12 means
“If the incident occurs 3 times consecutively, the water heater displays the “12” error code”— High and Super High Efficiency Tankless Water Heater Troubleshooting Manual, page 40
Rheem calls code 12 “detected presence of flame, then lost it.” The burner lit, then the flame went out, three times in a row.
Rheem’s owner’s manual lists two causes: gas service was interrupted, or a propane tank is running low. Its troubleshooting manual adds gas pressure, the gas filter, the vent and the flame rod. IKONIC heaters show A012 instead, after 15 flame losses in a row.
Model differences. IKONIC equivalent A012 counts 15 consecutive flame losses.
Why it happens
Likely causes of Rheem code 12
- Gas service has been interrupted. (AP21820 condensing tankless manual, p. 75)
- LP gas is running low (LP models only). (AP21820 condensing tankless manual, p. 75)
- Gas supply pressure, gas filter, venting or flame rod. (AP21822 tankless troubleshooting manual, p. 40)
What to do
Safe checks first. Then call a pro.
Safe checks you can do
If gas service was interrupted, contact your gas utility company. (AP21820 condensing tankless manual, p. 75)
LP models: refill or replace the LP gas container. (AP21820 condensing tankless manual, p. 75)
To clear the code:
- Owner reset for a displayed code: turn off all hot taps; turn the heater off with POWER ON/OFF; wait about 5 minutes and turn it back on; open a hot tap and recheck. If the code is still there: turn off the tap and heater, unplug the heater for about 30 seconds, plug back in, follow the code chart, and recheck. If it still shows, write down the code and call for service. (AP21820 condensing tankless manual, p. 74)
- Same owner reset steps (turn off, wait about 5 minutes, restart; then unplug about 30 seconds) in the 2012 Use and Care manuals. (AP15897 condensing tankless manual (2012), p. 25)
What a technician checks, and why
- Check static and dynamic gas pressure; clean the gas filter; check venting and DIP switches.Static and dynamic gas pressure are measured with a manometer at the heater’s gas connection (NG 4.0-10.5 in. W.C., LP 8.0-13.0 in. W.C.). (AP21822 tankless troubleshooting manual, p. 40)
- Check flame rod status (0Y), clean or replace the flame rod; test gas valve solenoids; replace gas valve or control board.Requires removing the front cover and testing or replacing internal parts (control board, sensors, valves, connectors) with a meter; the troubleshooting manual is written for qualified technicians only. (AP21822 tankless troubleshooting manual, p. 40)
Please don’t
- Don’t open the burner, the gas valve or the sealed combustion chamber.
- Don’t keep resetting a code that keeps coming back. A code that returns means the cause is still there.
- Don’t bypass or unplug a safety sensor to get hot water back.
- Don’t cover, tape or move the vent or the air intake.
Heater getting old, or the same code keeps coming back? Repair or replace? Three taps and Dan’s answer → Or see what a water heater repair usually involves.
Common questions
Rheem code 12 questions
Can a low propane tank cause Rheem code 12?
Yes. Rheem’s owner’s manual lists LP gas running low as a cause. Refill or replace the propane tank, then reset the heater.
Where this comes from
Sources
Taken from Rheem’s own documents, checked November 13, 2026. Page numbers are the printed page. Where models differ, we say which model each part applies to.
- High and Super High Efficiency Tankless Water Heater Troubleshooting Manual Rheem Manufacturing Company, Water Heater Division · AP21822 · Rev 02 (Copyright 2025) · Models: RTGH-68/84/90/95 DV(E)L(N/P)-3, RUTGH-..-3, ECOH160/180/200..-3, RMTGH..-3, RTG-70/84/95 DV(E)L / X(E)L (N/P)-3, RUTG-..-3, ECO160/180/200..-3, RMTG..-3
- Super High Efficiency Condensing Tankless Water Heater Use and Care Manual With Installation Instructions for the Installer Rheem Manufacturing Company · AP21820 · Rev 06 (PDF dated Jan 2024) · Models: RTGH-95DVELN-3, RTGH-68/84/90/95DVL-3
Water heater help
More about water heaters
Code won’t clear?
If you’re within about 30 miles of Westlake Village, call or text Dan a photo of the display and the label. He’ll tell you what it is.