Noritz error codes, in plain words
Noritz codes are two digits, like 11 or 90, flashing on the remote or the front display. Here’s every code in Noritz’s owner’s guides, service manuals and Help Center, from the 2002 N-series to today’s EZ series, in plain words. A few numbers changed meaning between generations, so we say which model each one applies to.
From Dan and Dave at Dan's Plumbing, a family plumbing shop in Westlake Village, California. We install Noritz. Every line below comes from Noritz’s own documents, with the page it’s on.
Noritz shows the code as two flashing digits on the remote controller or the front display. Older display-window models show a three-digit version, like 901, on the unit itself.
Smell gas? Don’t touch any switch or try to reset anything. Leave the house, then call 911 or your gas company from outside. In Southern California that’s SoCalGas, 1-800-427-2200.
Every code
All 109 Noritz codes
Current tankless: EZ series, NRCR and NCC199CDV
The GQ-61, GQ-60 and GQ-59 platforms, about 2017 on. Check the GQ number on the rating plate.
06On NRCR models with a built-in pump, water is moving through the recirculation loop, but not enough of it.Low recirculation flow (Recirculation abnormality)
On NRCR models with a built-in pump, water is moving through the recirculation loop, but not enough of it. It is a warning; the heater still makes hot water. (GQ-61 service manual (2026), p. 46)
By model: NRCR (recirculating) models only. Sub-codes 06-1 / 06-2 (OG writes 061, 062). The GQ-60 service manual pairs 06 with 63 for NRCR. On NRCP models the similar low-recirculation code is Er 46, and 06 is not used.
The recirculation type in the unit settings is wrong, or air is trapped in the hot line and return line (dedicated mode). (GQ-61 service manual (2026), p. 46)
Check the return line filter and the crossover valve’s filter. Call Noritz America if you have other questions. (GQ-61 owner’s guide (2025), p. 31)
For a technician
Check the recirculation type setting; in dedicated mode purge air from the hot water and return lines; in crossover mode check the crossover valve filter. (GQ-61 service manual (2026), p. 46)
10An early warning that air or gas flow is not right.Combustion abnormality (Only in error code history)
An early warning that air or gas flow is not right. The heater keeps running at a lower fan speed and only saves 10 in its history. If the problem gets worse it becomes code 90. (GQ-61 service manual (2026), p. 45)
By model: On GQ-61/GQ-60/GQ-59 and NRCB, 10 is a history-only warning. On 2002-2012 models 10 means a BTU drop while the unit keeps burning (see the next 10 entry). Noritz calls 10 a precursor to 90 (Help Center).
Likely causes
Blocked air supply vent or exhaust vent; low gas supply pressure; clogged, frozen or badly sloped condensate drain; wrong unit settings. (GQ-61 service manual (2026), p. 45)
Incorrect installation settings, low air flow (venting, dirty terminations or filters), low gas flow or heating value. (Noritz Help Center: 10 (Pro))
What you can check
If the heater takes combustion air from inside the house, look at the air supply vent for dust, lint or oil and clean it with a vacuum or damp towel. Do not remove the inlet screen. (GQ-61 owner’s guide (2025), pp. 26, 31)
Look at the exhaust vent and its outside end for anything blocking it. (GQ-61 owner’s guide (2025), p. 31)
Have a professional check the gas supply pressure; check the unit settings on the circuit board. Troubleshoot like code 90. (GQ-61 service manual (2026), pp. 45, 92)
11The heater tried to light but did not see a flame.Ignition failure (Initial flame fault detection)
The heater tried to light but did not see a flame. Most often the gas is off, gas pressure is low, or there is no spark. (GQ-61 service manual (2026), p. 45)
By model: NRCP shows Er:11 only after 10 failed ignitions and it is a hard lockout (Power button off/on). After draining or a long shutdown, 11 (and 41 on GQ-61) can appear and is not a malfunction (GQ-61 OG p. 25; older OGs say the same). Display-window units show 11 on both the window and the remote.
Likely causes
Gas valve closed, or air in the gas line (common right after install). (GQ-61 owner’s guide (2025), pp. 28, 31)
Defective ignition device, leakage of the ignition plug, gas supply problem, poor ground wire connection, defective flame rod. (GQ-61 service manual (2026), p. 70)
Outside the heater: the gas meter, regulator, gas line, shut-off valves, or in earthquake areas like California an earthquake safety shut-off valve. (Noritz Help Center: 11)
GQ-57: igniter failure, gas solenoid or proportioning valve fault, flame detecting circuit, disconnected ground, or gas supply / manifold pressure abnormality. (GQ-57 service manual (2018), p. 40)
2008-2011 models: gas supply piping and pressure, igniter spark, gas solenoid valves, flame rod, ground. (Service manual (2011), pp. 54-56)
What you can check
Check that the gas valve is open. Close the hot water tap and open it again; the heater tries again. You can also turn the POWER button off and on. If the number stops blinking, the problem is solved. (GQ-61 owner’s guide (2025), p. 31)
If the heater stops while running: are the gas and water valves fully open, is the water supply on, and do other gas appliances (like the stove) work? With propane, is there gas in the tank? (GQ-61 owner’s guide (2025), p. 31)
If the heater tries to light but fails: reset it and try again (there may be air in the gas line). Have a professional check the gas supply pressure. (GQ-61 owner’s guide (2025), p. 28)
Check that the gas valve is open. Press the power button to turn the unit off, open a hot water tap, and turn the unit back on. If the number does not come back, the problem is solved. (NRC111 GQ-57 owner’s guide (2017), p. 28)
Display-window models: unplug the unit or press the power button on the remote, open a hot tap, and turn the unit back on. (NRC661 owner’s guide (2013), p. 25)
NRCP: press the Power button to clear Er:11, make sure the gas valve is fully open; if it happens again call the installer or Noritz. (NRCP111/NRCP98 owner’s guide (2019), p. 34)
GQ-60 EZ: check that the gas valve is open; press the button to turn the heater off, open a hot water tap, and turn the heater back on. (GQ-60 owner’s guide (2021), p. 18)
GQ-59 EZ: same reset as the remote-controller models (power off, open a hot tap, power on). (GQ-59 owner’s guide (2021), p. 28)
2008-2011 and 2005 models: check the gas valve is open; press the power button off, open a hot tap, turn it back on. (NR111 owner’s guide (2009), p. 25)
2002 models: check the gas valve is open; turn off the operation button, open a hot tap, and turn the operation button on again. (N-042 owner’s guide, p. 23)
NRCB combi boiler: check the gas valve is open; power off, open a hot tap, power on. (NRCB owner’s guide (2021), p. 36)
For a technician
Check gas supply piping and pressure at full fire, igniter spark, gas valve, flame rod, and the ground connection to the circuit board. (GQ-61 service manual (2026), pp. 45, 70)
Check the gas meter, regulator, shut-off valves and any earthquake shut-off valve upstream of the heater. (Noritz Help Center: 11)
Look through the burner sight glass: no flame = check spark and gas; brief flame then 11 = clean/inspect the flame rod and check ground wires. (Noritz Help Center: 11)
GQ-57: check igniter output (DC 14-16 V), gas solenoid valve resistance (19-31 Ω primary, 36-58 Ω valve 1), proportioning valve (50-80 Ω), flame rod current (1 µA or more), ground wire, and manifold pressure. (GQ-57 service manual (2018), p. 40)
NRCP: make sure gas supply and inlet gas pressure are within spec; check spark through the burner window. (NRCP111/NRCP98 service manual (2019), p. 62)
NRCP: check the flame detector sensor line and connector; replace the flame sensor or the flame observation glass and gasket depending on voltage. (NRCP1112/NRCP982 service manual (2019), p. 59)
2008-2011: check gas supply piping and pressure, igniter spark, gas solenoid valves, flame rod and ground. (Service manual (2011), p. 55)
NRCB: check gas piping and pressure, igniter spark, gas valve, flame rod and ground to the board. (NRCB service manual (2020), p. 18)
Noritz training lists inlet gas pressure ranges for units up to 199k Btu: NG 4-10.5 in. WC, LP 8-14 in. WC (GQ-61 service manual gives NG 3.5-10.5, LP 8-13 for that platform). (Noritz Level 2 training (2024), p. 6)
By model: Sub-codes 12-1/12-2 on GQ-61 and 121/122 on display-window units. NRCP shows Er12 (Flame Loss) after flame loss 8 times in a row (NRCP SM p. 60).
Likely causes
Flame went out, abnormal combustion, gas valve, flame rod, poor ground, or exhaust gas leaking inside the unit or vent pipe. (GQ-61 service manual (2026), p. 45)
Not enough gas to stay lit; improper venting, for example a direct-vent air intake drawing in exhaust; the wrong vent type on DVC concentric models. (Noritz Help Center: 12)
GQ-57: flame rod or its ground, gas solenoid valves, or gas supply / manifold pressure abnormality. (GQ-57 service manual (2018), p. 41)
2008-2011: flame went out, abnormal combustion, gas solenoid valves, flame rod, ground. (Service manual (2011), pp. 54-56)
What you can check
NRCP: make sure the main gas supply valve is fully open, and clean the intake air filter (owner’s guide shows how). (NRCP1112/NRCP982 service manual (2019), p. 58)
NRCP owner’s guide: clean the air intake filter monthly (remove the filter screw, wash with a toothbrush, dry, reinstall). (NRCP111/NRCP98 owner’s guide (2019), p. 30)
If the heater stops while running: are the gas and water valves fully open, is the water supply on, and do other gas appliances (like the stove) work? With propane, is there gas in the tank? (GQ-61 owner’s guide (2025), p. 31)
Look at the outside vent ends for blockage or for another appliance’s exhaust right next to the air intake, and tell your installer. (Noritz Help Center: 12)
For a technician
Check for flame loss and abnormal combustion; check gas valve, flame rod and ground on the circuit board; check for exhaust leaks inside the unit and at the vent. (GQ-61 service manual (2026), p. 45)
GQ-57: visually confirm flame, check flame rod wiring and current (1 µA or more), ground wire, gas solenoid valves (36-58 Ω), and manifold pressure. (GQ-57 service manual (2018), p. 41)
2008-2011: check for flame loss, combustion, gas solenoid valves, flame rod and ground. (Service manual (2011), p. 55)
Clean the flame rod; check for sufficient gas; check venting (DV intake drawing exhaust; DVC units need the correct concentric vent). (Noritz Help Center: 12)
13An optional carbon monoxide (CO) alarm wired to the heater went off, or its wire is broken.External CO detector triggered
An optional carbon monoxide (CO) alarm wired to the heater went off, or its wire is broken. Treat it as a possible exhaust leak. (GQ-61 service manual (2026), p. 45)
By model: Only on units with the optional CO alarm connected. Sub-code 13-6 on GQ-61.
Likely causes
Abnormal combustion; loose vent parts; exhaust leaking from vent pipes; broken CO detector wire. (GQ-61 service manual (2026), p. 45)
Check for abnormal combustion, that all vent parts are secure, for exhaust leaks, and for an open circuit in the CO detector wire. (GQ-61 service manual (2026), p. 45)
14The heat exchanger got far too hot and a one-time safety fuse burned open.Overheat Prevention Device (Thermal Fuse) triggered
The heat exchanger got far too hot and a one-time safety fuse burned open. The heater will not run until the cause is fixed and the fuse is replaced. (GQ-57 service manual (2018), p. 35)
By model: Not listed in the GQ-60 Technical Sheet or GQ-59 EZ table. Not used on NRCP.
Likely causes
Exposed to temperatures over 430°F, for example a hole in the heat exchanger. (GQ-57 service manual (2018), p. 40)
Most common cause: scale build-up in the heat exchanger from hard water without treatment or regular descaling. (Noritz Help Center: 14)
For a technician
Measure the resistance through the thermal fuse and check it for melting or bad connection. Fix the cause of the overheat first, then replace the fuse. (GQ-57 service manual (2018), p. 40)
15The water going into the main heat exchanger is hotter than it should be.Abnormally high input temperature
The water going into the main heat exchanger is hotter than it should be. (GQ-60 technical sheet, p. 1)
Likely causes
Thermistor (primary heat exchanger inlet) problem or wrong gas type. (GQ-60 technical sheet, p. 1)
For a technician
Measure the resistance through the Thermistor-Primary Heat Exchanger Inlet; check gas type. (GQ-59 service manual (2017), p. 32)
16The hot water leaving the heater got too hot, so the heater shut off and slowed the water flow for safety.Abnormally high output temperature
The hot water leaving the heater got too hot, so the heater shut off and slowed the water flow for safety. (GQ-61 service manual (2026), p. 45)
By model: Sub-codes 16-# (GQ-61) and 161-163 (display window). GQ-57 trip points include hot water >= 194°F for 2 s at set temps under 170°F (SM p. 41). NRCP Er16 is an auto-reset overheat of the HEX/DHW sensors.
Likely causes
Scale in the heat exchanger and water parts; wrong manifold gas pressure; wrong gas type. (Noritz Help Center: 16)
NRCR: cold supply and hot return lines connected in reverse on a dedicated recirculation system. (Noritz Help Center: 16 (Pro))
Thermistor-hot water fault or gas valve offset pressure / gas type wrong. (GQ-61 service manual (2026), p. 45)
What you can check
Unplug the heater, wait 20 seconds, and plug it back in to reset. (Noritz Help Center: 16)
NRCP: turn the heater off for at least 30 minutes, then restart; clean the cold water inlet filter and recirculation return filter. (NRCP1112/NRCP982 service manual (2019), p. 58)
Clean the water filter in the water drain valve: turn the heater off and let it cool, close the hot and cold valves, unscrew the drain valve over a bucket, brush the filter under running water, and put it back with its O-ring. (GQ-61 owner’s guide (2025), p. 27)
For a technician
Measure the Thermistor-Hot Water resistance; check gas valve offset pressure and gas type. (GQ-61 service manual (2026), p. 45)
20A safety switch on the heat exchanger tripped because the water got near boiling.High Limit Switch triggered
A safety switch on the heat exchanger tripped because the water got near boiling. Scale build-up is the usual cause. (GQ-61 service manual (2026), p. 45)
By model: NCC199CDV also has a High Limit Switch-Hot Water (SM p. 47). NRCP calls it High Limit Switch Abnormality / Water High Limit Switch Abnormality (Er20). NRCB: High Limit Switch-Primary Heat Exchanger. The 2013 display-window table lists 20 just above 29.
Water in or leaving the heat exchanger nears 176°F to 205°F; scale is the most common cause. (Noritz Help Center: 20)
NRCB: air lock in the internal pump or air left in the boiler, dirty water filter, pump speed setting. (NRCB service manual (2020), p. 18)
What you can check
Reset by disconnecting power and reconnecting it (unplug, wait, plug back in). (GQ-61 service manual (2026), p. 45)
NRCP: turn the heater off for at least 30 minutes, then restart; clean the cold water inlet and recirculation return filters. (NRCP1112/NRCP982 service manual (2019), p. 58)
Check the burner-chamber high limit switch and its connection; check whether the burner chamber is clogged or damaged. To reset, contact the nearest Noritz agent. (GQ-59 service manual (2017), p. 32)
29On current GQ-61 models, 29 only shows when an outside condensate pump is wired to the heater.External Condensate Pump abnormality
On current GQ-61 models, 29 only shows when an outside condensate pump is wired to the heater. The pump is blocked or its plug is unplugged or damaged. (GQ-61 service manual (2026), p. 45)
By model: Sub-code 29-3. Not in the GQ-61 owner’s guide table.
Likely causes
External condensate pump blocked; condensate pump connector open circuit. (GQ-61 service manual (2026), p. 45)
Failure on the optional condensate pump: pump clogged, bad connection or damaged wiring; otherwise the drain pump or the unit’s circuit board may be faulty. (GQ-61 service manual (2026), p. 77)
Check the condensate drain pipe outlet for blockage (periodic check F). (GQ-61 owner’s guide (2025), p. 26)
If water does not come out of the end of the drain line, a qualified service technician must clean the condensate line. (GQ-61 owner’s guide (2025), p. 25)
For a technician
Check the external condensate pump for blockage and its connector for damage. (GQ-61 service manual (2026), p. 45)
Confirm an external condensate pump is used; check it is not clogged; check pump connection and wiring; if all normal, suspect the drain pump or circuit board. (GQ-61 service manual (2026), p. 77)
Check the condensate drain line size (1/2 inch minimum, plastic), slope, no added traps, and freeze protection. (Noritz Help Center: 29)
30The air temperature sensor inside the heater is open, shorted or unplugged.Thermistor-Air abnormality
The air temperature sensor inside the heater is open, shorted or unplugged. (GQ-61 service manual (2026), p. 45)
By model: 2012/2011 manuals call it "Air inlet thermistor abnormality". Display window shows 301/302. Means something else on NRCB (outdoor sensor) and N-132 (freeze thermostat).
For a technician
Measure the Thermistor-Air resistance; check for open/short circuit and connection. (GQ-61 service manual (2026), p. 45)
31The incoming (cold) water temperature sensor is open, shorted or unplugged.Thermistor-Cold Water abnormality (inlet thermistor)
The incoming (cold) water temperature sensor is open, shorted or unplugged. (GQ-61 service manual (2026), p. 45)
Check the water flow sensor and Water Servo-Main and their connections. (GQ-61 service manual (2026), p. 47)
42On NRCR models, the recirculation flow sensor is not working, so recirculation mode cannot stay stable.Water Flow Sensor (Recirculation) abnormality
On NRCR models, the recirculation flow sensor is not working, so recirculation mode cannot stay stable. (GQ-61 service manual (2026), p. 46)
For a technician
Check the voltage from the circuit board to the recirculation flow sensor. (GQ-61 service manual (2026), p. 46)
50Water has been flowing through the heater for 24 hours straight.Extended Continuous Flow Detected
Water has been flowing through the heater for 24 hours straight. The heater itself is fine - this usually means a leak or a tap left open after the heater. (GQ-61 service manual (2026), p. 45)
By model: History only. "This code does not indicate a water heater malfunction." (SM p. 45).
Likely causes
Leak in the drain line, inside the unit, or in the hot water piping; it cannot see leaks upstream of the unit. (Noritz Help Center: 50 (Pro))
61The combustion fan is not turning at the right speed, or the heater cannot read its speed.Fan Motor abnormality
The combustion fan is not turning at the right speed, or the heater cannot read its speed. (GQ-61 service manual (2026), p. 45)
By model: Sub-codes 61-1/61-4 (GQ-61) and 611/612/614 (display window; 612/614 = circuit board failure). NRCP: Er61 RPM Sensor.
For a technician
Check that the fan turns and the pulse frequency from the fan speed sensor; check fan connection and board voltage. (GQ-61 service manual (2026), p. 45)
63On NRCR models, the built-in recirculation pump is not moving water.Recirculation Abnormality (No recirculation flow)
By model: Older manuals: Gas Solenoid Valve drive circuit abnormality. GQ-59/NRCB: also measure the high limit switches.
Likely causes
Battery backup or solar/alternative power without a pure sine wave; another appliance on the same circuit causing interference. (Noritz Help Center: 71)
What you can check
Disconnect power and reconnect it; note any recent change to the electrical system (battery backup, solar, new appliance on the circuit). (Noritz Help Center: 71)
For a technician
Check the gas valve drive circuit on the board; replace the board if it persists. (GQ-61 service manual (2026), p. 45)
72The heater sees a flame when there should not be one.Flame Rod circuit abnormality (Detection of flame when no flame is present)
73The circuit board settings do not match (gas type, vent, DIP switches), or a plug or switch was changed with power on.Circuit Board setting abnormality
The circuit board settings do not match (gas type, vent, DIP switches), or a plug or switch was changed with power on. (GQ-61 service manual (2026), p. 45)
By model: Sub-codes 731, 733, 734, 735. 735 is a lockout reset with maintenance writer #5F (GQ-61 SM p. 98). NRCP: Er73 DIP Switch Setting Abnormality.
Likely causes
Wrong maintenance writer, gas type setting or LP-conversion connector; board damage. (GQ-61 service manual (2026), p. 45)
Check installation settings (gas type, vent type/size) via the operation panel or app; replace the board if settings are right. (GQ-61 service manual (2026), p. 88)
74The Bluetooth module for the app is not talking to the board.BLE connection error
The Bluetooth module for the app is not talking to the board. Saved in history only. (GQ-61 service manual (2026), p. 45)
90The fuel-and-air mix is off, so the heater shut down.Combustion abnormality (Unit shuts off)
The fuel-and-air mix is off, so the heater shut down. It is struggling to pull in air, push out exhaust, or get enough gas. On condensing models a clogged or frozen condensate drain can also cause it. (GQ-61 service manual (2026), p. 45)
By model: Meaning is the same in every family that uses it (combustion / air-flow abnormality), but details differ: GQ-61 adds sub-codes 90-1, 90-2, 90-8 and locks (908) after 30 detections; GQ-57, 2012 and 2008-2011 models can show 90 first as a warning while still running, then shut off; display-window models show 901/902/903/908 on the unit and 90 on the remote; on GQ-61/GQ-60/GQ-59/NRCB code 10 is the early warning. NRCP models do not use 90 at all.
Likely causes
Air supply vent may be clogged (when combustion air comes from indoors); exhaust vent may be clogged; abnormal combustion or low gas supply pressure; condensate drain line may be clogged. (GQ-61 owner’s guide (2025), p. 31)
Unit detected abnormal air flow when it started; a gas with too low a heating value can also cause it. (GQ-61 service manual (2026), p. 92)
New installs: low gas heating value, low gas pressure, wrong venting, bad condensate drain install, wrong elevation / vent size / vent length settings. Older installs: usually a dirty unit or clogged condensate drain. (Noritz Help Center: 90 (Pro))
Fan speed (maintenance monitor 49) above 100 means trouble moving air in or out; outlet temperature (monitor 31) well below set point means not enough gas reaches the burner. A lint-filled fan can cause 90. (Noritz Help Center: 90)
GQ-57: fan speed raised to 103% gives a warning while running; 104% stops combustion. (GQ-57 service manual (2018), p. 40)
2008-2011 models: fan speed raised 110% (N-0631S -OD 115%) gives a warning; more makes combustion stop. (Service manual (2011), p. 62)
Display-window models: 90 on the remote is shown as 901 / 903 / 908 (air flow or combustion) or 902 (low gas pressure) on the unit window. (NRC711 owner’s guide (2017), p. 25)
2002 N-132: combustion abnormality where the burner sensor detects high temperature, or BTU drop. (N-132 service manual (2002), p. 15)
What you can check
If the heater takes combustion air from inside the house, look at the air supply vent for dust, lint or oil and clean it with a vacuum or damp towel. Do not remove the inlet screen. (GQ-61 owner’s guide (2025), pp. 26, 31)
Look at the exhaust vent and its outside end for anything blocking it. (GQ-61 owner’s guide (2025), p. 31)
Have a professional check the gas supply pressure. If the code keeps coming back, contact the nearest Noritz agent. (GQ-61 owner’s guide (2025), p. 31)
GQ-60 EZ: check the air supply vent (indoor air), the exhaust vent, and the condensate drain line for clogging or freezing; have a professional check gas pressure. (GQ-60 owner’s guide (2021), p. 18)
GQ-59 EZ: same checks - air supply vent, exhaust vent, condensate drain line. (GQ-59 owner’s guide (2021), p. 28)
GQ-57 and 2012 condensing: clean the air supply vent (indoor air). If the display continues, contact the nearest Noritz agent. (NRC111 GQ-57 owner’s guide (2017), p. 28)
Display-window models: clean the air supply vent; NRC663 (EZTR40): clean the air inlet filter. (NRC663 owner’s guide (2017), p. 24)
2008-2011 and 2005 non-condensing: have a professional check gas supply pressure; contact the nearest Noritz agent. (NR111 owner’s guide (2009), p. 25)
NRCB combi boiler: check the air supply vent, exhaust vent and condensate drain line; have a professional check gas pressure. (NRCB owner’s guide (2021), p. 36)
For a technician
Check air intake, exhaust and the intake air filter inside the unit for blockage. After fixing, disconnect power, wait 20 seconds, reconnect. (GQ-61 service manual (2026), p. 92)
Check the condensate drain line (clogged, frozen) and that the drain pipe slopes down. (GQ-61 service manual (2026), p. 92)
Check installation settings: common vent, vent type, elevation, vent length, vent size (installation manual). (GQ-61 service manual (2026), p. 92)
Measure inlet gas pressure while the heater runs at full fire. Natural gas 3.5-10.5 in. W.C.; propane 8-13 in. W.C. (GQ-61 service manual (2026), p. 92)
Check Thermistor-Heat Exchanger Outlet: in Drain Mode with water flowing, maintenance monitors #30 and #32 should agree within ±5°F; check resistance at CN63. (GQ-61 service manual (2026), pp. 92-93)
GQ-61 lockout 908 (after 90 is detected 30 times): after fixing the cause, reset maintenance writer #5F from ON to OFF. (GQ-61 service manual (2026), pp. 92, 98)
Run the unit and read maintenance monitors 31 (outlet temp) and 49 (fan speed); clean a lint-filled fan. (Noritz Help Center: 90)
Run the unit at low, medium and high flow with other gas appliances on while watching inlet gas pressure on a manometer. (Noritz Help Center: 90 (Pro))
GQ-60 / GQ-59: check vents, gas pressure, condensate drain and slope, and the DIP switch settings on the circuit board. (GQ-60 technical sheet, p. 1)
GQ-57: check for abnormal combustion, flue and air inlet blockage, and that flame lights all across the burner; read maintenance monitor No. 49 for fan speed. (GQ-57 service manual (2018), pp. 35, 40)
2012 series: check for abnormal combustion, flue blockage, flame across the burner; reset by disconnecting power. (Service manual (2012), pp. 40-42)
2008-2011 series: check maintenance monitors No. 48 and 49 for fan speed; check combustion and flue. (Service manual (2011), p. 62)
Display-window models: 90 = air flow abnormality; check flue and air inlet for blockage. (Service manual (2013), p. 28)
2002 N-042/N-063: visually check flame quality, check flue for blockage, check wiring to the gas solenoid valves. (N-042 service manual (2002), p. 21)
NRCB: check air supply and exhaust vents, condensate drain slope and clogging, gas supply pressure, and DIP switch settings; reset by disconnecting power. (NRCB service manual (2020), p. 19)
901A combustion warning shown on the unit’s display window.Combustion abnormality (Warning indication) / sub-code 90-1
A combustion warning shown on the unit’s display window. The remote shows 90. Air may not be getting in or out well. (Service manual (2013), p. 28)
By model: The 2013 / GQ-59 (NRC663) tables list 901 twice: warning indication, and unit shuts off. GQ-61 lists 90-1 as a sub-code of 90 and its owner’s guide groups 901 with 90.
If the heater takes combustion air from inside the house, look at the air supply vent for dust, lint or oil and clean it with a vacuum or damp towel. Do not remove the inlet screen. (GQ-61 owner’s guide (2025), pp. 26, 31)
For a technician
Check for abnormal combustion and flue / air inlet blockage; reset by disconnecting power. (Service manual (2013), p. 28)
902Gas pressure to the heater is too low, or the flame is not lighting all across the burner.Combustion abnormality (Unit shuts off) - low gas supply pressure
Gas pressure to the heater is too low, or the flame is not lighting all across the burner. The heater shuts off. (NRC661 owner’s guide (2013), p. 25)
By model: GQ-61: 90-2 sub-code; the Rev. 10/25 owner’s guide lists 902 under code 90.
Flame not igniting all across the burner; gas solenoid valves. (Service manual (2013), p. 28)
What you can check
Have a professional check the gas supply pressure. Contact the nearest Noritz agent. (NRC661 owner’s guide (2013), p. 25)
If the heater stops while running: are the gas and water valves fully open, is the water supply on, and do other gas appliances (like the stove) work? With propane, is there gas in the tank? (GQ-61 owner’s guide (2025), p. 31)
For a technician
Check combustion, that flame ignites all across the burner, and the gas solenoid valves; reset by disconnecting power. (Service manual (2013), p. 28)
Measure inlet gas pressure while the heater runs at full fire. Natural gas 3.5-10.5 in. W.C.; propane 8-13 in. W.C. (GQ-61 service manual (2026), p. 92)
908The heater found combustion problems again and again and locked itself off for safety.Combustion abnormality (Unit is locked)
The heater found combustion problems again and again and locked itself off for safety. It needs service. (Service manual (2013), p. 28)
By model: GQ-61 service manual: "If '908' is displayed, an lockout has been activated." (p. 45).
Likely causes
Repeated combustion abnormality; check flue and air inlet. (Service manual (2013), p. 28)
Clean the air supply vent if you can reach it; contact the nearest Noritz agent. (NRC711 owner’s guide (2017), p. 25)
For a technician
To reset this error code, contact the nearest Noritz agent. (Service manual (2013), p. 28)
GQ-61 (-1 models): disconnect power 20 s, enter Maintenance Writer from the operation panel and set #5F to OFF; non -1 models use the board buttons (5F.1 -> 0). (GQ-61 service manual (2026), p. 98)
91The heater may be set up for the wrong gas (natural gas vs.Improper gas type / gas conversion not done correctly
The heater may be set up for the wrong gas (natural gas vs. propane), or the conversion was not finished right. (GQ-61 owner’s guide (2025), p. 31)
Likely causes
Wrong gas type, gas orifice or gas-type setting; wrong vent / elevation settings. (GQ-61 service manual (2026), p. 45)
Supplied gas does not match the unit; manifold pressures off; dirty fan, burner or heat exchanger fins. (Noritz Help Center: 91)
99A serious combustion problem.Combustion abnormality (Unit is locked / Unit shuts off)
A serious combustion problem. The heater shuts off, and on GQ-57 models it locks until a Noritz agent resets it. Noritz says that on an older unit this can mean it has reached the end of its life. (GQ-57 service manual (2018), p. 35)
By model: Locked on GQ-57 ("To reset this error code, Contact the nearest NORITZ agent", SM p. 35); only "Unit shuts off" (power reset) on the 2012 and 2011 tables. GQ-60, GQ-59 and display-window owner’s guides list 99 as "Abnormal combustion - contact the nearest Noritz agent" even though their service tables do not. N-042 SM: 99 applies to N-063 only. Not used on GQ-61 or NRCP.
If the unit has been in use for 10 years (NRC series) / 5 years (NCC series), it has reached the end of its life cycle. (GQ-57 service manual (2018), p. 40)
2008-2011 models: if in use 10 years, the unit has reached the end of its life cycle and should be replaced. (Service manual (2011), p. 62)
GQ-57 lock reset: remote off, power off 10 s and on, hold UP until 99 blinks (maintenance writer mode), turn MW 3F OFF, hold UP+DOWN 5 s to save. (GQ-57 service manual (2018), p. 42)
2012 and 2008-2011 series: reset by disconnecting and reconnecting power after fixing the cause. (Service manual (2012), p. 40)
760The heater and its remote control (or built-in panel) are not talking to each other.Remote Controller transmission abnormality
The heater and its remote control (or built-in panel) are not talking to each other. (GQ-61 service manual (2026), p. 45)
By model: GQ-61: history only, and covers the operation panel too (760-1 to 760-4). Display-window units show "No Display" on the window. NRCB: Operation Panel transmission abnormality.
What you can check
Make sure the remote control and its cord are securely connected all the way from the unit to the remote. (Noritz Help Center: 760)
For a technician
Check the connection from the remote to the circuit board and the remote and board for damage; check DC 14-16 V at the remote terminal (GQ-57). (GQ-57 service manual (2018), p. 40)
Check the remote connection and the remote and circuit board for damage. (GQ-61 service manual (2026), p. 45)
C1#A reminder that it is time to flush (descale) the heat exchanger.Service Reminder (Descaling Reminder) (Warning Indication)
A reminder that it is time to flush (descale) the heat exchanger. The heater keeps working. On GQ-61 it is off from the factory and must be turned on by the owner or installer. (GQ-61 service manual (2026), p. 45)
By model: # = 1-9. Different from C1-C4/CF on GQ-57 and display-window models, which are real scale detections that lead to shutdown and lockout.
Hard water: excessive scale can make the heat exchanger fail early; dust or lint in the fan and air intake also hurts combustion. (GQ-61 owner’s guide (2025), p. 32)
What you can check
Refer to the flushing procedure in the installation manual or contact Noritz America (1-866-766-7489). (GQ-61 owner’s guide (2025), p. 28)
Water over 12 gpg hardness should be treated; damage after ignoring C1# is not covered by warranty. (GQ-61 owner’s guide (2025), p. 28)
NRC and NR models, the display-window models and the N-series. A few codes mean something else on these.
01The burner ran for more than an hour without stopping, so the heater shut itself off as a safety step.Continuous Use Timer Triggered
The burner ran for more than an hour without stopping, so the heater shut itself off as a safety step. (N-042 service manual (2002), p. 21)
By model: Only the N-042 and N-063 owner’s manuals list 01. The 2002 service manual says the same timer applies to both.
Likely causes
Hot water has been running for 60 minutes or more. (N-042 owner’s guide, p. 23)
Hot water has been running for 60 minutes or more. (N-063 owner’s guide, p. 24)
What you can check
Turn off the hot water tap, switch the power off and back on. If 01 does not come back, the heater is working normally. (N-042 owner’s guide, p. 23)
05This is a maintenance reminder, not a breakdown.Service reminder
This is a maintenance reminder, not a breakdown. The set service time has passed, so the heat exchanger should be flushed or the water treatment serviced. (Service manual (2012), p. 40)
By model: Listed for NRC98 and NRC83 (-DV/-OD) and NR83-DVC in the 2012 service manual. Not used on the NRC1111, NCC1991, NR981 or NC1991 tables.
Call a Noritz service agent for maintenance. The owner’s guide says to reset the 05 display on the remote only after the heater is flushed or the water treatment is serviced. (NRC98 owner’s guide (2013), p. 27)
For a technician
Flush the heat exchanger and/or service the water treatment device. (Service manual (2012), p. 40)
After service, reset the reminder: power button OFF; hold Flow Meter Alarm Set >2 s; press it until "7 oF" shows; hold the up-arrow setting button >5 s; press Power. (NRC98 owner’s guide (2013), p. 27)
10The heater cut back its gas because combustion was not right, but it keeps running.Combustion abnormality (BTU Drop) (Unit Continues Working)
The heater cut back its gas because combustion was not right, but it keeps running. Hot water may be weaker. (Service manual (2011), p. 62)
By model: On the 2002 N-042/N-063/N-132 service manuals, 10 also covers "Flame Does Not Go Out (Unit Shuts Off)" - see the separate entry.
Check for flame remaining after the unit shuts down and check the inlet water temperature. (N-042 service manual (2002), p. 21)
21On some older indoor commercial-style units, the heater is not getting enough air or the exhaust is blocked.Insufficient air supply, exhaust blockage (Pressure switch triggered)
On some older indoor commercial-style units, the heater is not getting enough air or the exhaust is blocked. A pressure switch shut it off. (N-1321M owner’s guide (2008), p. 24)
By model: NC380-SV-ASME / N-1321M-ASME (2011 SM says "For NC380-SV-ASME/N-1321M-ASME only"), N-132M (2005) and N-132 (2002). Same number means burner-chamber high limit on GQ-59 and NRCB.
Likely causes
Not enough air in the room or a blocked exhaust; a range hood or kitchen fan running in the room. (N-1321M owner’s guide (2008), p. 24)
Pressure switch triggered: check pressure switch, fan motor, flue blockage, abnormal combustion. (Service manual (2011), p. 56)
What you can check
If the alarm does not sound: open a door or window to let air in, close the hot water taps, and turn the unit off. If the code does not return when turned back on, the unit was not getting enough air. Turn down any range hood or kitchen fan in the room. (N-1321M owner’s guide (2008), p. 24)
If the alarm sounds (N-132): turn off the operation button to stop the alarm, open a window, and contact the nearest Noritz agent - the heater has an abnormality. (N-132 owner’s guide, p. 24)
For a technician
Check the pressure switch, fan motor, flue for blockage, and combustion. (Service manual (2011), p. 56)
29On condensing models, the acidic water (condensate) the heater makes cannot drain out.Clogging of condensate trap or drain pipe (Condensate Container clogging)
On condensing models, the acidic water (condensate) the heater makes cannot drain out. The drain line is clogged, frozen, or not sloped down. (NRC111 GQ-57 owner’s guide (2017), p. 28)
By model: Condensing units only. NRC1111/NCC1991 (2012): "Condensate drain trap abnormality". Different meanings on other families: GQ-61 = external condensate pump; 2009 NRC111/NCC199 = neutralizer; NRCP = air pressure switch. Not listed for non-condensing NR662/NR501/NER66.
Drain line smaller than 1/2 inch, not plastic, extra traps added, or run outside where it freezes. (Noritz Help Center: 29)
2012 NRC98/NRC83: condensate trap clogging - drain line clogged or frozen. NRC1111/NCC1991: condensate drain trap or drain pipe blocked, or water level electrode not connected. (Service manual (2012), pp. 40-41)
Display-window condensing models: condensate container clogging - drain line clogged or frozen. (Service manual (2013), p. 28)
Thermalux NERC98DV / NERC11DV: same check; owner’s guide gives the Thermalux customer care number. (NERC98 owner’s guide (2019), p. 28)
For a technician
Check the drain trap and drain line for blockage and slope; check the water level electrode connection (maintenance monitor No. 19 should read OFF/000). (GQ-57 service manual (2018), pp. 35, 40-41)
Check the drain line is at least 1/2 inch, plastic, short, sloped toward the drain, with no extra traps, and protected from freezing. (Noritz Help Center: 29)
2012: check the neutralizer / drain-trap water level electrode with maintenance monitor 19 (000 = normal, 001 = abnormal). (Service manual (2012), p. 41)
29On 2008-2011 NRC111 and NCC199 heaters with a built-in neutralizer, the neutralizer or its drain is clogged.Clogging of neutralizer (Neutralizer Water Level Electrode abnormality)
On 2008-2011 NRC111 and NCC199 heaters with a built-in neutralizer, the neutralizer or its drain is clogged. (NRC111 owner’s guide (2009), p. 27)
By model: NRC111-SV/DV (N-0842MC) and NCC199-SV/DV (N-0841MC) only.
Likely causes
Drain pipe blocked; neutralizer blocked; water level electrode not connected. (Service manual (2011), p. 55)
Condensate backs up when the drain line is blocked, frozen or not sloped; condensing units only. (Noritz Help Center: 29)
Check the drain pipe and neutralizer for blockage and the neutralizer water level electrode connection (monitor No. 19). (Service manual (2011), p. 55)
Check the drain line is 1/2 inch minimum, plastic, sloped, with no extra traps and no freezing. (Noritz Help Center: 29)
30On the 2002 N-132, the freeze protection thermostat is open, shorted or unplugged.Freeze Protection Thermostat Abnormality
On the 2002 N-132, the freeze protection thermostat is open, shorted or unplugged. (N-132 service manual (2002), p. 15)
By model: N-132 only.
For a technician
Measure the freeze protection thermostat resistance; check for open/short or bad connection. (N-132 service manual (2002), p. 15)
34The sensor that watches for scale on the heat exchanger fell off or is open, shorted or unplugged.Thermistor-Scale Detection abnormality
The sensor that watches for scale on the heat exchanger fell off or is open, shorted or unplugged. (GQ-57 service manual (2018), p. 35)
By model: Only GQ-57 models with this sensor: NRC111OD/DV, NR98OD/DVC/SV, NCC199OD/DV, NC199OD/DVC (SM p. 41 Note 3). Not found in any other family’s tables.
For a technician
Check that the scale detection thermistor has not dropped off the primary heat exchanger; measure its resistance; check connection. (GQ-57 service manual (2018), pp. 35, 41)
39On the 2002 N-132, the burner sensor (thermocouple) is open, shorted or unplugged.Burner Sensor (Thermocouple) Abnormality
On the 2002 N-132, the burner sensor (thermocouple) is open, shorted or unplugged. (N-132 service manual (2002), p. 15)
For a technician
Measure the voltage from the burner sensor; check for open/short or bad connection. (N-132 service manual (2002), p. 15)
41On some 2008-2011 models, the water flow sensor is dirty or damaged.Flow Sensor Abnormality
On some 2008-2011 models, the water flow sensor is dirty or damaged. (Service manual (2011), p. 56)
By model: NR98/NC199/N-0751M, NR111/NC250/N-0931M, NC380/N-1321M table.
Check the fan motor; if all else is normal the unit may need a fan motor adjustment (needs an external remote; call Noritz). (Noritz Help Center: 903)
Check combustion and flue / air inlet blockage; reset by disconnecting power. (Service manual (2013), p. 28)
92The built-in condensate neutralizer is near the end of its life.Neutralizer Life Cycle Warning
The built-in condensate neutralizer is near the end of its life. The heater still works, but with less hot water. (NRC111 owner’s guide (2009), p. 27)
By model: NRC111-SV/DV (N-0842MC) and NCC199-SV/DV (N-0841MC) only.
What you can check
The heater can be used for a while, but maximum hot water flow is reduced. Contact the installer or Noritz Technical Support. (NRC111 owner’s guide (2009), p. 27)
Follow the instructions included with the replacement neutralizer. (Service manual (2011), p. 55)
93The built-in condensate neutralizer is used up.Neutralizer Life Cycle has ended
The built-in condensate neutralizer is used up. The heater cannot be used until it is replaced. (NRC111 owner’s guide (2009), p. 27)
By model: NRC111-SV/DV (N-0842MC) and NCC199-SV/DV (N-0841MC) only.
What you can check
The equipment cannot be used. Contact the installer or Noritz Technical Support. (NRC111 owner’s guide (2009), p. 27)
For a technician
Replace the neutralizer (part SKD7466) and follow its reset procedure. (Noritz Help Center: 93)
C1–C4The heater measured scale (hard-water mineral build-up) in its heat exchanger.Detect Scale Build-up in the Heat Exchanger (Warning, then shuts off)
The heater measured scale (hard-water mineral build-up) in its heat exchanger. It warns first. If it is not flushed, it shuts off and soon locks (CF). (GQ-57 service manual (2018), p. 35)
By model: Display-window units show C*# on the window (* = 1-4 or F, # = 1-9, A, b, C, d, E, F) and C1-C4 on the remote.
Likely causes
Scale build-up; shows more often when set to 125°F or higher. Noritz recommends a low temperature setting. (NRC111 GQ-57 owner’s guide (2017), p. 13)
What you can check
The unit may shut off and lock. If it does, it can run for now by disconnecting electrical power until the heat exchanger is flushed. Contact Noritz America (866-766-7489) about flushing. (NRC111 GQ-57 owner’s guide (2017), p. 28)
For a technician
Flush the heat exchanger ("Procedure for Flushing the Heat Exchanger" in the parts list pocket or installation manual). (GQ-57 service manual (2018), p. 41)
CF#Scale warnings came back many times, so the heater locked itself.Detect Scale Build-up in the Heat Exchanger (Unit is locked)
LampOn some models used without a remote, a light on the front of the heater flashes instead of a number.Unit abnormality (error displays on the lamp)
On some models used without a remote, a light on the front of the heater flashes instead of a number. (NR71 owner’s guide (2011), p. 26)
By model: NR71-SV / NR71-OD (2011) and N-063S / N-069M (2005). The 2011 service manual (p. 54) maps the number of flashes to codes for NR71/N-0631S, but that table did not extract cleanly and is not used here.
What you can check
Check whether the gas valve is open. Close the hot water tap and open it again. If the lamp does not start flashing again, the problem is solved. (NR71 owner’s guide (2011), p. 26)
NRCP with built-in recirculation
Shown as Er and the number. Some are hard lockouts cleared with the power button.
29On NRCP models, a pressure switch found the exhaust or air path blocked.Air Pressure Switch Abnormality
On NRCP models, a pressure switch found the exhaust or air path blocked. Check the vent, the air filter and the condensate drain. (NRCP1112/NRCP982 service manual (2019), p. 58)
By model: Er:29 is a hard lockout on NRCP (Power button off/on).
Likely causes
Exhaust pipe blocked, dirty intake air filter, clogged condensate trap or drain pipe, condensate line not sloped down. (NRCP111/NRCP98 service manual (2019), p. 62)
The air pressure switch protects against exhaust backing in when the exhaust vent or passage is blocked by condensate. (NRCP1112/NRCP982 service manual (2019), p. 25)
Press the Power button to clear the code. Make sure the exhaust pipe is clear, clean the intake air filter, and check that the condensate trap and drain pipe are not clogged. If it comes back, call the installer or Noritz. (NRCP111/NRCP98 owner’s guide (2019), p. 34)
NRCP1112/NRCP982 owner’s guide: same steps - clear the exhaust pipe, clean the intake air filter, check the condensate trap and drain pipe. (NRCP1112/NRCP982 owner’s guide (2019), p. 39)
Check connections around the air pressure switch, its hose for blockage or bending, the condensate passage, and the switch voltage range. (NRCP1112/NRCP982 service manual (2019), p. 25)
Make sure the front cover is closed securely; clean the flame window; check the flame sensor voltage (5 VDC when flame is off). (NRCP111/NRCP98 service manual (2019), p. 62)
40On NRCP models, a gas sensor inside the heater detected gas.Gas Leakage
By model: Hard lockout (Power button off/on). The owner’s guide lists the soap test and burner check, but the service manual’s first step is "Turn off the gas" and call support.
Likely causes
Cover not secure, a leak at gas connections, burner assembly condition, or a circuit board fault. (NRCP111/NRCP98 owner’s guide (2019), p. 34)
What you can check
If you smell gas, stop and follow the gas-smell steps; call a qualified technician or the gas utility. (NRCP111/NRCP98 owner’s guide (2019), p. 34)
Leak-test gas connections with soapy solution and repair leaks; check the burner assembly; replace the circuit board if it persists. (NRCP111/NRCP98 owner’s guide (2019), p. 34)
41On NRCP models, the fan cannot hold its speed, often because the exhaust or condensate is blocked.Fan Speed Error / Fan Speed Abnormality (Exhaust Blockage)
On NRCP models, the fan cannot hold its speed, often because the exhaust or condensate is blocked. (NRCP111/NRCP98 service manual (2019), p. 62)
What you can check
Try main power off/on; make sure the exhaust pipe is clear and the condensate trap/pipe is not clogged. (NRCP111/NRCP98 service manual (2019), p. 62)
Check flame condition through the burner window, check the air intake filter, check gasket damage around the burner; contact technical support. (NRCP111/NRCP98 service manual (2019), p. 62)
44On NRCP models, the built-in recirculation pump or loop is not working right.Recirculation Abnormality / Possible pump failure
By model: NRCP111/NRCP98 manual words it "Possible pump failure".
What you can check
Check the return line filter (the owner’s guide also lists loop length and pump checks, which are installer work). (NRCP1112/NRCP982 owner’s guide (2019), p. 39)
For a technician
Verify the recirculation loop length is within specification; check recirculation setting (External/Internal) and pump operation. (NRCP1112/NRCP982 service manual (2019), p. 58)
45On NRCP models, a leak sensor in the bottom of the heater got wet.Water Leak
Check pump operation; verify loop length and recirculation setting (External or On-Demand, with or without crossover valve). (NRCP111/NRCP98 service manual (2019), p. 62)
60On NRCP models, the hot water got too hot (over 167°F at normal settings).Hot water temp. abnormality
Check for leaks at the relief valve, piping and boiler; check the heating water pressure. (NRCB service manual (2020), p. 18)
24On the NRCB combi boiler, the 0-10 volt heat-demand wires are hooked up backwards.Heat Demand (0-10VDC) reverse connection
On the NRCB combi boiler, the 0-10 volt heat-demand wires are hooked up backwards. (NRCB service manual (2020), p. 18)
By model: Combi boiler only.
For a technician
Connect the heat demand wires to the correct terminals on the circuit board (they have polarity). (NRCB service manual (2020), p. 18)
26On the NRCB combi boiler, the low-water cutoff tripped or is not wired right.Low Water Cutoff abnormality
On the NRCB combi boiler, the low-water cutoff tripped or is not wired right. (NRCB service manual (2020), p. 18)
By model: Combi boiler only.
For a technician
Measure 24 VAC at the board terminal; check the LWCO or its short-circuit connector; make up water to the system; check the auto feeder. (NRCB service manual (2020), p. 18)
30On the NRCB combi boiler, the outdoor temperature sensor is open or shorted.Outdoor Temperature Sensor Open or Short Circuit
On the NRCB combi boiler, the outdoor temperature sensor is open or shorted. (NRCB service manual (2020), p. 18)
For a technician
Check the outdoor sensor and connections; check resistance; replace if zero. (NRCB service manual (2020), p. 18)
36On the NRCB combi boiler, the heating supply sensor is open, shorted or unplugged.Thermistor-Heat Supply abnormality
On the NRCB combi boiler, the heating supply sensor is open, shorted or unplugged. (NRCB service manual (2020), p. 18)
For a technician
Measure the heat supply thermistor; clean the drain-plug water filter; check pump speed and scale. (NRCB service manual (2020), p. 18)
37On the NRCB combi boiler, the heating return sensor is open, shorted or unplugged.Thermistor-Heat Return abnormality
On the NRCB combi boiler, the heating return sensor is open, shorted or unplugged. (NRCB service manual (2020), p. 18)
For a technician
Measure the heat return thermistor; check for open/short and connection. (NRCB service manual (2020), p. 18)
43On the NRCB combi boiler, the heating pressure sensor is open or shorted.Heating Water Pressure Sensor abnormality
On the NRCB combi boiler, the heating pressure sensor is open or shorted. (NRCB service manual (2020), p. 18)
F-03One of the electric backup elements is not drawing power (F-03 top, F-04 bottom).Element does not draw power (F-03 top, F-04 bottom)
One of the electric backup elements is not drawing power (F-03 top, F-04 bottom). (EcoTough heat pump manual, p. 29)
For a technician
Turn power off; check connections in the junction box and at the high limit and element terminals; check element resistance. (EcoTough heat pump manual, p. 29)
F-05Neither electric element is getting power.No current through both elements
If an external timer switch is used, check it. If the problem continues, call a service professional. (EcoTough heat pump manual, p. 29)
For a technician
Check junction box and element connections and for a tripped or faulty high limit. (EcoTough heat pump manual, p. 29)
F-06The heat pump and the tank controller are not talking.Communication error between controller and heat pump
The heat pump and the tank controller are not talking. The heater switches to electric mode. (EcoTough heat pump manual, p. 29)
For a technician
Turn power off; check connections on the main control and heat pump control; repower. (EcoTough heat pump manual, p. 29)
F-07The air filter on top of the heat pump needs cleaning.Filter needs cleaning
The air filter on top of the heat pump needs cleaning. This is the only code you must clear by hand. (EcoTough heat pump manual, p. 29)
What you can check
Pull the filter out from the top of the heater, vacuum it or wash it with soap and water, let it dry, and put it back. (EcoTough heat pump manual, p. 26)
Clear the warning: hold the button for the options menu ("FLtr"), choose "rSt", and confirm. (EcoTough heat pump manual, p. 26)
F-08The heat pump’s air temperature sensor has a problem.Heat pump air temperature sensor error
Turn power off; check connections on the heat pump control board. (EcoTough heat pump manual, p. 29)
F-09The heat pump’s pressure sensor has a problem.Heat pump pressure sensor error
The heat pump’s pressure sensor has a problem. The heater switches to electric mode. (EcoTough heat pump manual, p. 29)
For a technician
Turn power off; check connections on the heat pump control board. (EcoTough heat pump manual, p. 29)
F-10The heat pump’s water temperature sensor has a problem.Heat pump water temperature sensor error
The heat pump’s water temperature sensor has a problem. The heater switches to electric mode. (EcoTough heat pump manual, p. 30)
For a technician
Turn power off; check connections on the heat pump control board. (EcoTough heat pump manual, p. 30)
F-11The defrost temperature sensor has a problem.Heat pump defrost temperature sensor error
The defrost temperature sensor has a problem. The heater switches to electric mode. (EcoTough heat pump manual, p. 30)
For a technician
Turn power off; check connections on the heat pump control board. (EcoTough heat pump manual, p. 30)
F-12A pressure switch in the refrigeration system tripped.Refrigeration pressure error - pressure limit switch tripped
A pressure switch in the refrigeration system tripped. The heater switches to electric mode. (EcoTough heat pump manual, p. 30)
For a technician
Power off; remove the top housing and press the red reset button; bleed air; run the Prime setting; confirm the water pump circulates. (EcoTough heat pump manual, p. 30)
F-13The condensate tube is blocked.Condensate tube blocked
The condensate tube is blocked. The heater switches to electric mode. (EcoTough heat pump manual, p. 30)
By model: Status LED on the Hybrid Hot pump controller.
What you can check
Contact Noritz America technical support at (866) 766-7489. Codes can take up to 3 minutes to show. (Hybrid Hot manual (2026), p. 28)
No Noritz code matches that. Check the number on the display again, or look at the other brands.
Clearing a code
How to reset a Noritz, and when to stop
To clear a code
Ignition-type codes: close the hot water tap and open it again; the heater resumes. The code can also be cleared by turning the POWER button / Power switch off and on. (GQ-61 owner’s guide (2025), p. 31)
Codes such as 20, 65, 70, 71, 73, F76, 90, 91 and 94 reset only when electrical power is disconnected and reconnected. After fixing a 90, disconnect power, wait 20 seconds, then reconnect. (GQ-61 service manual (2026), pp. 45, 92)
Lockouts 735 and 908 need a service reset of maintenance writer #5F (pro step). (GQ-61 service manual (2026), p. 98)
Press the button to turn the water heater off, open a hot water tap, and turn the water heater back on. If the blinking number does not return, the problem is solved. (GQ-60 owner’s guide (2021), p. 18)
Press the power button to turn the unit off, open a hot water tap, and turn the unit back on. If the flashing number does not return, the problem is solved. (NRC111 GQ-57 owner’s guide (2017), p. 28)
Unplug the unit from power or press the power button on the optional remote to turn it off, open a hot water tap, and turn the unit back on. (NRC661 owner’s guide (2013), p. 25)
908 (unit locked): to reset, contact the nearest Noritz agent. (Service manual (2013), p. 28)
Units without a remote (flashing lamp): close the hot water tap, then open it again. (NR71 owner’s guide (2011), p. 26)
Turn off the operation button, open a hot water tap, and turn the operation button on again. (N-042 owner’s guide, p. 23)
Code 99 lock on GQ-57 models: service reset of maintenance writer 3F (pro step); the table says to contact the nearest Noritz agent. (GQ-57 service manual (2018), pp. 35, 42)
Soft lockouts clear when the condition goes away. Hard lockouts (Er11, Er29, Er40, Er72) clear by pressing the Power button off, then on. (NRCP1112/NRCP982 owner’s guide (2019), p. 39)
88 (service reminder) resets by pressing the power ON/OFF button 5 times in 5 seconds after maintenance; most other codes reset by disconnecting and reconnecting power. (NRCB service manual (2020), pp. 18-19)
05 service warning: reset the remote only after the heater is flushed or the water treatment is serviced (power off, hold Flow Meter Alarm Set >2 s, press until "7 oF", hold the up-arrow button >5 s, press Power). (NRC98 owner’s guide (2013), p. 27)
Noritz Help Center: 73 resets by unplugging the heater 30 seconds; 16 resets by unplugging, waiting 20 seconds, and plugging back in. (Noritz Help Center: 73)
To silence the error tone on the RC-9018M remote, press the ALARM OFF button. Commercial units: press the alarm button to stop the error alarm. (RC-9018 remote guide (2019), p. 18)
To read past codes on a residential remote: turn the remote OFF, hold UP and DOWN together until 03 shows, press DOWN (91 + latest code), then UP twice for each older code; 000 means no more history. (Noritz Help Center: code history)
Heat pump: F-07 must be cleared by hand after cleaning the filter; all other F-codes clear on their own when fixed. (EcoTough heat pump manual, p. 29)
Noritz’s safety notes
WHAT TO DO IF YOU SMELL GAS: do not try to light any appliance; do not touch any electrical switch or use any phone in your building; call your gas supplier from a neighbor’s phone; if you cannot reach them, call the fire department. (GQ-61 owner’s guide (2025), pp. 1, 3)
When a gas leak is noticed: stop use immediately, close the gas valve, and (indoor installation) open windows and doors. (GQ-61 owner’s guide (2025), p. 3)
If you detect abnormal combustion or abnormal odors, or during an earthquake, tornado or fire: turn off the hot water, turn off power to the heater, turn off the gas and water supply valves, and call the nearest Noritz agent. (GQ-61 owner’s guide (2025), p. 3)
Use only your hand to turn the gas valve knob. If it will not turn by hand, don’t try to repair it; call a qualified service technician. Force or attempted repair may result in a fire or explosion. (GQ-61 owner’s guide (2025), p. 3)
Do not use the water heater if any part has been under water; call a qualified service technician to inspect it. (GQ-61 owner’s guide (2025), p. 3)
If the temperature and pressure relief valve drips or leaks, have a qualified service technician replace it. Do not plug or remove the valve. (GQ-61 owner’s guide (2025), p. 3)
Contact a qualified service technician for any necessary repairs, service or maintenance. (GQ-61 owner’s guide (2025), p. 4)
Propane: if the gas conversion sticker is not on the unit, do not use it and contact the installer. (GQ-61 owner’s guide (2025), p. 31)
Freeze protection only works with power connected - do not unplug the heater. It works whether the POWER button is on or off. It does not protect piping outside the heater. If the heater or piping is frozen, do not use it. Freeze damage is not covered by the warranty. (GQ-61 owner’s guide (2025), p. 23)
DANGER: after a long shutdown, the condensate trap must be refilled (by running the heater as described) so exhaust gases cannot enter the building. (GQ-61 owner’s guide (2025), p. 25)
If no water comes out of the condensate drain line, a qualified service technician must clean the condensate line. (GQ-61 owner’s guide (2025), p. 25)
To prevent burns, turn the heater off and wait until it cools before any maintenance or filter cleaning. (GQ-61 owner’s guide (2025), pp. 26-27)
The heat-exchanger flushing (descaling) procedure is only intended for a qualified service professional or authorized Noritz service representative. (GQ-61 installation manual (2025), p. 69)
NRCP: "IMPORTANT: If you smell gas, STOP!" Follow the gas-smell instructions and call a qualified service technician or the gas utility. (NRCP111/NRCP98 owner’s guide (2019), p. 34)
NRCP owner’s guide includes a flushing procedure but calls it complicated and says to contact a professional if you do not understand it. (NRCP111/NRCP98 owner’s guide (2019), p. 32)
Do not attempt to bypass the thermal fuse; it is a critical safety device. (Noritz Help Center: 14)
GQ-61 locks itself (908) after code 90 is detected 30 times; no Noritz document found gives a "do not reset more than N times" rule. (GQ-61 service manual (2026), p. 92)
NRCB code 64: DO NOT ignore this condition - failing to purge air from the internal pump can damage the heat exchanger. (NRCB owner’s guide (2021), p. 36)
Code 99 on a unit about 10 years old (NRC) or 5 years old (NCC) means it has reached the end of its life cycle and should be replaced. (GQ-57 service manual (2018), p. 40)
GQ-61 (2023 on): EZ111DV, EZ98DV, EZ71DV, NRCR, NCC199CDVEZ111DV (GQ-C3261WX-FF US, GQ-C3261WX-FF-1 US), EZ98DV (GQ-C2861WX-FF US, GQ-C2861WX-FF-1 US), EZ71DV (GQ-C2661WX-FF US, GQ-C2661WX-FF-1 US), NRCR111DV (GQ-C3261WXQ-FF US, -FF-1 US), NRCR92DV (GQ-C2661WXQ-FF US, -FF-1 US), NCC199CDV (GQ-C3261WZ-FF US, -FF-1 US) · 2- or 3-digit code blinks on the unit’s operation panel (backlight turns red) and on the RC-9018M remote if one is installed; also shown in the EZ Start Plus app and under Error History (8 most recent). In history a 3-digit code such as 731 can show as "73-1". On a remote in a Quick Connect system, "F##" means the code came from the secondary unit.
GQ-60 (about 2019–2023): EZ and EZTR, NRCREZ111DV / EZTR75 (GQ-C3260WX-FF US), EZ98DV / EZTR50 (GQ-C2860WX-FF US), NRCR111DV (GQ-C3260WXQ-FF US), NRCR92DV (GQ-C2660WXQ-FF US), NCC199CDV (GQ-C3260WZ-FF US) · Code blinks on the unit display or remote controller. "F##" on a remote = code from the secondary unit in a Quick Connect multi-system (Technical Sheet).
GQ-59 (about 2017–2019): the first EZ seriesEZ111DV / EZTR75 (GQ-C3259WX-FF US), EZ98DV / EZTR50 (GQ-C2859WX-FF US), NCC199CDV (GQ-C3259WZ-FF US) · Numerical code flashes on the remote controller; the display and the operation light flash together. "F##" = code from the secondary unit in a Quick Connect multi-system.
Display-window models (2013–2019): NRC661, NRC711, NRC663, NR662, NR501, NER66NRC661-DV, NRC661-OD, NRC711-DV, NRC711-OD, NRC661A-DV, NRC661A-OD, NRC663-FSV (EZTR40), NR662-OD, NR501-OD, NER66OD (GQ-2039WS ET US) · 3-digit code on the unit’s own display window (for example 901, 941, 768) and a 2-digit code on the optional remote controller (for example 90, 94, 76).
GQ-57 condensing (about 2015–2020): NRC111, NRC98, NCC199, ThermaluxNRC111DV (GQ-C3257WX-FF US), NRC111OD (GQ-C3257WX US), NRC98DV (GQ-C2857WS-FF US), NRC98OD (GQ-C2857WS US), NCC199DV (GQ-C3257WZ-FF US), NCC199OD (GQ-C3257WZ US), NERC98DV (GQ-C2857WS-FF ET US), NERC11DV (GQ-C3257WX-FF ET US), NCC300DV (GQ-C5032WZ-FF US), NCC300OD (GQ-C5032WZ US) · Numerical code flashes on the remote controller (RC-7651M on NRC111DV); the display and operation light flash together. Commercial models: code blinks on the display and an error alarm may sound.
GQ-57 non-condensing: NR98, NR83, NR71, NC199NR98OD (GQ-2857WX US), NR98DVC (GQ-2857WX-FFA US), NR98SV (GQ-2857WX-F US), NR83DVC (GQ-2457WS-FFA US), NR83OD (GQ-2457WS US), NR71DVC (GQ-2457WS-FFA-1 US), NC199OD (GQ-2857WZ US), NC199DVC (GQ-2857WZ-FFA US) · Numerical code flashes on the remote controller; the display and operation light flash together. NC199: code blinks on the display and an error alarm may sound.
2012–2013 series: NRC1111, NRC98, NRC83, NCC1991, NR981NRC1111-DV, NRC1111-OD, NRC98-DV, NRC98-OD, NRC83-DV, NRC83-OD, NCC1991-DV, NCC1991-OD, NR981-OD, NR981-DVC, NR981-SV, NC1991-OD, NC1991-DVC, NR83-DVC · Numerical code flashes on the remote controller; commercial NC1991 shows it on the display and an alarm may sound. "F##" = secondary unit in a Quick Connect system.
2008–2011 series: NRC111, NCC199, NR50 to NR111NRC111-SV / NRC111-DV (N-0842MC), NCC199-SV / NCC199-DV (N-0841MC), NR50-OD, NR66-SV/-OD (N-0531S), NR71-SV/-OD (N-0631S), NR98-SV/-OD/-DVC (N-0751M), NC199-OD/-DVC, NR111-SV/-OD/-DV (N-0931M), NC250-SV/-DV-ASME, NC380-SV-ASME (N-1321M-ASME) · Numerical code flashes on the remote controller. NR71-SV/OD without a remote: a lamp on the front of the unit flashes.
2005 N-series: N-063S, N-069M, N-084M, N-132MN-063S, N-069M, N-069M-DV, N-084M, N-084M-DV, N-132M · Numerical code flashes on the remote controller; on some models a lamp on the front of the unit flashes when no remote is used.
2002 N-series: N-042, N-063, N-084, N-132N-042, N-063, N-084, N-132 · Number flashes on the remote controller (RC-7646M per the 2002 service manuals).
NRCP with built-in recirculationNRCP1112-DV, NRCP982-DV, NRCP111-DV (2019), NRCP98-DV (2019) · The control panel flashes "Er" followed by the number (for example Er:11). The last errors are kept in Error History E0-E9 (menu I:EH).
NRCB combi boiler (heat and hot water)NRCB199DV (GHQ-C3201WX-FF US), NRCB180DV (GHQ-C2801WX-FF US) · Numerical code flashes on the Operation Panel. In a Quick Connect system "F##" (except F76) is a code from the connected water heater.
EcoTough heat pump (tank)NHP50, NHP65, NHP80 (same manual listed on the Noritz literature site for NHP50) · The controller alternates "Err" with an F-code such as F-07.
Hybrid Hot pump controllerNHH199100-2 (GQ61-1) · LED on the pump controller blinks red 1-4 times.
The model name alone doesn’t tell you the generation. An NRC111DV can be a 2009 or a 2015-and-later heater, so check the GQ number on the rating plate.
On most Noritz heaters, press the power button to turn it off, open a hot water tap, then turn it back on. On current EZ (GQ-61) heaters, ignition codes also clear when you close and reopen the hot tap, but codes like 90 only clear when the power is disconnected and reconnected. If the code keeps coming back, call your installer or Noritz.
Does Noritz code 29 mean the same thing on every model?
No. On most condensing models it’s a clogged or frozen condensate drain. On current EZ (GQ-61) heaters it’s an outside condensate pump problem. On 2008–2011 NRC111 and NCC199 heaters it’s the built-in neutralizer, and on NRCP heaters it’s the air pressure switch.
What does Noritz code 99 mean?
It’s a lockout that only a Noritz agent can reset. Noritz says a 99 on a heater that’s about 10 years old means it has reached the end of its life.
Why did my Noritz show code 11 after it was drained or shut off?
Noritz says 11 can show after draining or a long shutdown, from air in the gas line, and that it isn’t a malfunction. Reset it and try again. If it keeps happening, have the gas supply checked.
Where this comes from
Sources
Every meaning, cause and step on this page is from Noritz’s own documents, checked November 13, 2026. Page numbers are the printed page. We left out codes we only found on forums.