Rinnai · Error code 12 · Checked November 2026
Rinnai error code 12: flame failure
The burner lit, then the flame went out, or the heater couldn’t sense it. The gas supply is the first thing to check.
Smell gas? Don’t touch any switch or try to reset anything. Leave the house, then call 911 or your gas company from outside. In Southern California that’s SoCalGas, 1-800-427-2200.
From Dan and Dave at Dan's Plumbing, a family plumbing shop in Westlake Village, California. Everything below comes from Rinnai’s own documents, cited line by line.
What it means
What Rinnai says code 12 means
“12 No Flame”— Tankless Water Heater (Residential) Installation and Operation Manual — RU199/RU180/RU160/RU130 i/e, page 73
Rinnai’s owner manuals call code 12 “no flame,” and its troubleshooting guide calls it “flame failure.” The burner lit, then the flame went out, or the heater couldn’t sense the flame and shut off the gas.
Gas supply comes first: a closed valve, an empty propane tank or low gas pressure. After that, Rinnai’s guide points to the flame rod (the sensor that proves there’s a flame), exhaust being pulled back into the air intake, and wiring.
Model differences. Guide calls it 'Flame Failure'; owner tables call it 'No Flame' (SENSEI, RE, Value, KB) or 'Flame Failure' (VA, VB).
On other Rinnai models, 12 means something else:
- EH5U T5U failureThe upper tank water temperature sensor failed. On: REHP heat pump water heater (tank).
Why it happens
Likely causes of Rinnai code 12
- Gas off or propane tank empty; low inlet gas pressure or undersized gas system. (Diagnostic codes guide (2024), p. 20)
- Loose or damaged flame rod/electrode, bad flame-rod wiring, cracked silicone sleeve. (Diagnostic codes guide (2024), p. 21)
- Recirculated exhaust from vent joints not fully engaged or poor terminal clearances. (Diagnostic codes guide (2024), p. 20)
- Poor grounding or wrong polarity; moisture in wiring; MSA/MSB fault. (Diagnostic codes guide (2024), p. 21)
- Immediate 12 with no visible flame on SENSEI/RX/CX: a DC short in a component. (Diagnostic codes guide (2024), p. 21)
What to do
Safe checks first. Then call a pro.
Safe checks you can do
Check that the gas is turned on at the water heater, gas meter, or cylinder. (RU manual, p. 73)
If you have propane, make sure there is gas in the tank. (RU manual, p. 73)
Check outside for obstructions in the flue outlet. (V series manual, p. 34)
What a technician checks, and why
- Check inlet gas pressure with all appliances on high fire; check for undersized piping (max 0.3 in. drop natural gas, 0.5 in. propane on black iron).Gas pressure, gas type and gas-line work need a qualified gas technician. (Diagnostic codes guide (2024), p. 20)
- Check vent joints, equivalent length and materials.Vent system changes and vent-length/DIP settings are installer work. (Diagnostic codes guide (2024), p. 20)
- Tighten or replace electrode/flame rod and gasket (gap 3.5 mm); check flame-rod wiring and sleeve.Opens the burner/combustion chamber or gas valve. (Diagnostic codes guide (2024), p. 21)
- Check grounding and polarity (licensed electrician if unsure); dry wet harnesses; isolate MSA/MSB.Live electrical testing inside the unit; Rinnai says only trained and qualified professionals should do it. (Diagnostic codes guide (2024), p. 21)
- Immediate 12/19: unplug components one at a time to find a DC short.Live electrical testing inside the unit; Rinnai says only trained and qualified professionals should do it. (Diagnostic codes guide (2024), p. 21)
- Measure gas valve solenoid; replace gas valve.Live electrical testing inside the unit; Rinnai says only trained and qualified professionals should do it. (Diagnostic codes guide (2024), p. 21)
Please don’t
- Don’t open the burner, the gas valve or the sealed combustion chamber.
- Don’t keep resetting a code that keeps coming back. A code that returns means the cause is still there.
- Don’t bypass or unplug a safety sensor to get hot water back.
- Don’t cover, tape or move the vent or the air intake.
Heater getting old, or the same code keeps coming back? Repair or replace? Three taps and Dan’s answer → Or see what a water heater repair usually involves.
Common questions
Rinnai code 12 questions
What’s the difference between Rinnai code 11 and 12?
11 means the burner never lit. 12 means it lit, then the flame went out or the heater couldn’t sense it.
Can low gas pressure cause Rinnai code 12?
Yes. Rinnai’s guide lists low inlet gas pressure and undersized gas piping among the causes. Checking gas pressure takes a gauge and is a technician’s job.
Where this comes from
Sources
Taken from Rinnai’s own documents, checked November 13, 2026. Page numbers are the printed page. Where models differ, we say which model each part applies to.
- Tankless Water Heater (Residential) Installation and Operation Manual — RU199/RU180/RU160/RU130 i/e Rinnai America Corporation · 100000467 · (07) · Models: RU199i, RU180i, RU160i, RU130i, RU199e, RU180e, RU160e, RU130e
- Troubleshooting Tankless Water Heater Diagnostic Codes Rinnai America Corporation · 100000652 · file '100000652-Troubleshooting TWH Diagnostic Codes (3).pdf', PDF dated 2024-05-08; byte-identical to the library’s 'TWH Troubleshooting Technical Data Sheet' · Models: RU/RUR/RSC/CU SENSEI, RX/RXP/CX/CXP SENSEI RX/CX, RE/REP (VE), V53e/V53De/V65/V75/V94/V94X (VC Value), RL75/RL94/RLX94 (VC Luxury, VB), R50LS/R63LS/R75LS/R94LS/R98LS (VA), RC80/RC98 (KA), RU80/RU90/RU98, RUC80/90/98, C199 (KB/KBD), RUR98 (KBP), RUCS65/75, RUS65/75 (KCM), RH180 (HTT)
- Direct Vent Tankless Water Heater Installation and Operation Manual — Value Series (V94i, V94Xi, V75i, V65i, V94e, V75e, V65e) Rinnai America Corporation · 100000258 / U307-1120X04 · (10) · Models: V94i, V94Xi, V75i, V65i, V94e, V75e, V65e
Water heater help
More about water heaters
Code won’t clear?
If you’re within about 30 miles of Westlake Village, call or text Dan a photo of the display and the label. He’ll tell you what it is.
Or send the details and Dan will call you back. Monday to Friday, 9am – 5pm.