Bradford White error codes, in plain words
Bradford White gas tanks talk through the status light on the gas control: count the blinks, then the pause. Here’s every code in Bradford White’s service manuals, owner’s manuals and quick service guides, in plain words. The same count means different things on a standard tank and a power vent tank, so start with what you have.
Most looked up
From Dan and Dave at Dan's Plumbing, a family plumbing shop in Westlake Village, California. We install Bradford White. Every line below comes from Bradford White’s own documents, with the page it’s on.
Smell gas? Don’t touch any switch or try to reset anything. Leave the house, then call 911 or your gas company from outside. In Southern California that’s SoCalGas, 1-800-427-2200.
Every code
All 176 Bradford White codes
Gas tanks with a pilot: ICON and Defender
Standard atmospheric and direct vent tanks, including the Eco-Defender Ultra Low NOx tanks sold in Southern California. Count the blinks, then the 3-second pause.
-
The light is off because the pilot is out.None (LED not on or flashing)
The light is off because the pilot is out. The pilot’s thermopile powers this control, so with no pilot there is no light and no heat. (Service manual 238-51542-00E, p. 9)
By model: Same meaning on every standing-pilot control (V1, V2, SIT/White-Rodgers, Ultra Low NOx). V2 manuals word it 'Millivolt power is not present. Light pilot.'
Likely causes
- Pilot assembly is not lit; gas control is not powered. (Service manual 238-51542-00E, p. 9)
- Thermopile failure (pre-2015 Honeywell control). (Service manual 238-44943-00D, p. 5)
- No incoming gas or too low gas pressure (pilot will not light). (Service manual 238-51542-00E, p. 6)
What you can check
- Look through the sight glass to see whether the pilot flame is lit. (Atmospheric quick service guide, p. 1)
- Relight the pilot exactly as the lighting label on the heater says (knob to OFF, wait 5 minutes, smell for gas, then PILOT). If the pilot will not stay lit after several tries, turn the knob to OFF and call a technician. (Owner’s manual 238-51012-00T, p. 17)
- If the pilot will not light at all, make sure the gas supply to the heater is turned on. (Service manual 238-51542-00E, p. 6)
For a technician
- If the pilot will not stay lit, replace the pilot assembly; if the problem persists, replace the gas control. (Service manual 238-51542-00E, p. 9)
- Open-circuit thermopile test with the pilot lit: normal is 350-850 mV; under 350 mV test the resettable thermal switch, and if it is closed replace the pilot assembly. (Service manual 238-51542-00E, p. 17)
- Test the resettable thermal switch on the inner door for continuity. If open, find the cause before pressing its red reset button: blocked combustion air, dirty flame arrestor, wrong/weak switch, or a flammable vapor incident (replace the water heater). (Service manual 238-51542-00E, p. 37)
- Pre-2015 ECO-Defender: if the pilot will not stay lit replace the thermopile; if the problem persists replace the gas valve. (Service manual 47132A, p. 5)
-
Not a fault.One flash and three second pause (V1) / One flash every four seconds (V2, SIT/White-Rodgers)
Not a fault. The pilot is lit. Either the knob is still on PILOT, or the tank is up to temperature. (Service manual 238-51542-00E, p. 9)
By model: V2: green LED, 'Not an error. Indicates pilot is lit and main burner is off.' (bw-51542 p. 11).
What you can check
- If the knob is still on PILOT, turn it to the desired temperature setting. (Service manual 238-51542-00E, p. 9)
-
Normal.LED strobe (two quick flashes) and three second pause
Normal. The burner is on and heating. Two QUICK flashes are normal; two slow flashes with a pause are the weak-pilot code. (Owner’s manual 238-51012-00T, p. 23)
By model: Shown on atmospheric V1 controls (RG/LG, URG). Pre-2015 UDS/UDH: 'Two quick flashes and a three second pause' (bw-49640a p. 4). Direct vent V1 and all V2 / SIT controls show heating as one flash per second instead.
-
Normal.Short flash once per second (DV V1) / One flash every second (V2 green, SIT/White-Rodgers)
Normal. The main burner is on and the tank is heating. (Service manual 238-51542-00E, p. 11)
By model: On standing-pilot direct vent V1 (RG2DV, URG2DV) this means calling for heat (bw-51636 p. 6, bw-51635 p. 6). Do not confuse with power vent / electronic-ignition models, where one short flash per second means a weak pilot signal.
-
Not a fault.LED on continuously (solid) / Solid ON (V2 red)
Not a fault. The knob was just turned to OFF. Wait until the light goes out before you relight. (Service manual 238-51542-00E, p. 9)
By model: V2 shows this as a solid red LED: 'Not an error-indicates that the control is in OFF position.'
What you can check
- Wait until the LED goes out before attempting to relight. (Service manual 238-51542-00E, p. 9)
-
The pilot flame is too weak to power the control, so the burner will not come on.Two flashes and three second pause (V2: LED yellow)
The pilot flame is too weak to power the control, so the burner will not come on. The control resets by itself once the pilot is strong again. (Service manual 238-51542-00E, p. 9)
By model: V2 shows yellow LED: 'Low thermopile voltage; main valve not turned on.' On standing-pilot Defender tanks the flammable-vapor protection is the resettable thermal switch in the thermopile circuit, not a vapor sensor; an open switch starves the control of millivolts.
Likely causes
- Thermopile failure. (Service manual 238-51542-00E, p. 9)
- Unstable pilot. (Service manual 238-51542-00E, p. 9)
- Pilot tube blocked or restricted. (Service manual 238-51542-00E, p. 9)
- Resettable thermal switch has opened (pre-2015 Defender and ECO-Defender charts). This switch trips on flammable vapor ignition or blocked combustion air. (Service manual 238-44943-00D, p. 5)
- Loose thermopile connections or weak pilot flame (SIT/White-Rodgers control). (Service manual 238-51542-00E, p. 8)
What you can check
- Look through the sight glass to see whether the pilot flame is lit. (Atmospheric quick service guide, p. 1)
- Keep the air slots in the outer jacket open: clear away lint, dust and anything stored against the heater. Keep gasoline, paint thinner and other flammable products away from it. (Owner’s manual 238-51012-00T, p. 21)
For a technician
- Open-circuit thermopile test with the pilot lit: normal is 350-850 mV; under 350 mV test the resettable thermal switch, and if it is closed replace the pilot assembly. (Service manual 238-51542-00E, p. 17)
- Check the thermopile wire connections at the gas valve. (Atmospheric quick service guide, p. 1)
- Pull the burner, inspect and clean the pilot (primary air openings, kinks, pilot orifice); replace the pilot assembly if damaged. (Service manual 238-51542-00E, p. 18)
- Test the resettable thermal switch on the inner door for continuity. If open, find the cause before pressing its red reset button: blocked combustion air, dirty flame arrestor, wrong/weak switch, or a flammable vapor incident (replace the water heater). (Service manual 238-51542-00E, p. 37)
- Ultra Low NOx: closed-circuit thermopile test should read 300 mV or more; open-circuit over 400 mV; otherwise replace the pilot assembly. (Service manual 238-51546-00C, p. 17)
-
The burner ran but the water did not warm up as fast as the control expected.Three flashes and three second pause
The burner ran but the water did not warm up as fast as the control expected. The control resets itself. (Service manual 238-51542-00E, p. 9)
By model: Not listed on V2 or SIT/White-Rodgers charts.
Likely causes
- Thermal sensor out of calibration. (Service manual 238-51542-00E, p. 9)
- Faulty gas control. (Service manual 238-51542-00E, p. 9)
- Gas valve has not seen temp rise in proper amount of time (water may be flowing). (Atmospheric quick service guide, p. 1)
- Pre-2015 ECO-Defender: thermowell sensor and chamber temperature sensor out of calibration; possible short. (Service manual 47132A, p. 5)
What you can check
- Make sure no hot water is running: check for a dripping or open hot tap or a running fixture. (Atmospheric quick service guide, p. 1)
For a technician
- Check temperature probe ohms; Ultra Low NOx also check gas pressure. (Ultra Low NOx quick service guide, p. 1)
- Replace gas control. (Service manual 238-51542-00E, p. 9)
-
The water got too hot and the safety cutoff (ECO) shut the heater down.Four flashes and three second pause (V2: LED red)
The water got too hot and the safety cutoff (ECO) shut the heater down. It stays off until it is reset. (Service manual 238-51542-00E, p. 10)
By model: V2/SIT wording: 'Temperature cut-out limit reached, causing shutdown.'
Likely causes
- Temperature sensor out of calibration. (Service manual 238-51542-00E, p. 10)
- Faulty gas control. (Service manual 238-51542-00E, p. 10)
- Excessive temperatures may have been reached (SIT/White-Rodgers). (Service manual 238-51542-00E, p. 8)
What you can check
- If the water overheats or the gas will not shut off, turn off the manual gas valve to the heater and call a qualified service technician. (Owner’s manual 238-51012-00T, p. 20)
- Check whether hot water from another source (solar, boiler loop, recirculation) could be heating the tank: the guide says verify no heat migration in plumbing system. (Quick service guide 238-55592-00A, p. 1)
For a technician
- Check temp probe ohms; check if tank temperature exceeds setpoint. (Quick service guide 238-55592-00A, p. 1)
- Reset the over-temperature (ECO) lockout: knob to OFF, wait at least 5 minutes, relight per the lighting label; if 4 flashes return, test the temperature sensor. (Service manual 238-51542-00E, p. 25)
- Test the temperature sensor with pin-type probes and compare to the resistance-vs-water-temperature chart (e.g. 8,449 ohms at 84 F); replace the sensor if wrong, otherwise replace the gas control. (Service manual 238-51542-00E, p. 30)
- Measure tank water temperature at the drain (after drawing about 4 gallons) and compare with the knob setting; they should be within about 10 F. (Service manual 238-51546-00C, p. 14)
- Replace the gas control (drain the tank first; do not use a wrench on the control body). (Service manual 238-51542-00E, p. 32)
-
The control cannot read its water temperature sensor (damaged, unplugged or out of range), or the control itself has a fault.Five flashes and three second pause (V2: LED red)
The control cannot read its water temperature sensor (damaged, unplugged or out of range), or the control itself has a fault. (Service manual 238-51542-00E, p. 10)
By model: Pre-2015 ECO-Defender calls it 'Thermostat well fault'. Ultra Low NOx V2: owner’s manual says 'Water temperature sensor failure' (bw-53393 p. 24); service manual says 'Electronics, sensor, or gas valve fault detected' (bw-51546 p. 9).
Likely causes
- Damage to the temperature sensor, resistance is out of range, or sensor is unplugged. (Service manual 238-51542-00E, p. 10)
- Faulty gas control. (Service manual 238-51542-00E, p. 10)
- V2 / SIT controls: electronics, sensor, or gas valve fault; control may be wet or damaged. (Service manual 238-51542-00E, p. 8)
What you can check
- Owner’s manual reset: turn the set point knob to OFF, then to PILOT, and light the pilot. If 5 flashes come back, the gas valve needs replacing. (Owner’s manual 238-51012-00T, p. 23)
For a technician
- Verify the control is not wet or physically damaged. (Service manual 238-51546-00C, p. 7)
- Test the temperature sensor with pin-type probes and compare to the resistance-vs-water-temperature chart (e.g. 8,449 ohms at 84 F); replace the sensor if wrong, otherwise replace the gas control. (Service manual 238-51542-00E, p. 30)
- Replace gas valve if five flash status persists. (Service manual 238-51546-00C, p. 7)
-
An optional leak-detection module found water in the drain pan or water dam under the heater.Six flashes and three second pause - water leak (accessory module)
An optional leak-detection module found water in the drain pan or water dam under the heater. (Service manual 238-51542-00E, p. 10)
By model: Only when the leak accessory module is installed ('if installed', bw-atm-qsg; 'some models', bw-51012 p. 23). Applies to RG/LG atmospheric and pre-2015 M-series (V1) to ICON 2.0 (V2) standard atmospheric and direct vent tanks per the 2019+ quick guide (bw-55593: 'Tank leakage detected by accesory module'), and to URG2DV per its 2018 service manual (bw-51635 pp. 7-8; but see the ULN chamber-sensor entry). Not listed in the RG2DV V1 chart. On Ultra Low NOx ATMOSPHERIC URG models 6 flashes means a chamber sensor fault instead (next entry).
Likely causes
- Excessive amount of water in drain pan/water dam. (Service manual 238-51542-00E, p. 10)
What you can check
- Look for water in the drain pan and around the heater, the relief valve pipe and the water connections. (Service manual 238-51542-00E, p. 10)
For a technician
- Check the T&P valve, check all water fittings, then pressurize and leak test the tank. (Service manual 238-51542-00E, p. 10)
-
On Ultra Low NOx (URG/U-series) tanks, the sensor on the burner door that watches the combustion chamber is reading out of range, or its wiring is shorted.Six flashes and three second pause - chamber (door) temperature sensor (Ultra Low NOx atmospheric)
On Ultra Low NOx (URG/U-series) tanks, the sensor on the burner door that watches the combustion chamber is reading out of range, or its wiring is shorted. (Service manual 238-51546-00C, p. 7)
By model: V2 (red LED) wording: 'Door temperature sensor failure' (bw-51546 p. 9). CONFLICT: the 2024 URG owner’s manual V1 table (bw-53393 p. 23) lists 6 flashes as a water leak from the accessory module, copied from the standard tank; the URG service manual and URG quick service guide both say chamber sensor. The 2019+ Bradford White quick service guides (bw-55594 ICON 1.0, bw-55595 ICON 2.0) cover Ultra Low NOx atmospheric AND direct vent models and both say chamber door sensor; the older URG2DV service manual (bw-51635, 2018) lists 6 flashes as a leak-module code. Bradford White’s documents conflict on this for the URG2DV.
Likely causes
- Chamber temperature sensor out of calibration. (Service manual 238-51546-00C, p. 7)
- Possible short. (Service manual 238-51546-00C, p. 7)
- Chamber door temp sensor out of specification; dirty ScreenLok or burner. (Ultra Low NOx quick service guide, p. 1)
What you can check
- Reset the gas control: turn the knob to OFF, then follow the lighting instructions. (Service manual 47132A, p. 6)
For a technician
- Chamber sensor test: remove the sensor from the right inner door, measure resistance with pin probes and compare with the ambient-temperature chart (e.g. 137-90 kOhms at 68-77 F). (Service manual 238-51546-00C, p. 16)
- Check door sensor ohms; clean ScreenLok vapor screen in chamber; clean burner. (Quick service guide 238-55594-00A, p. 1)
- Clean the ScreenLok flame arrestor and the burner. (Ultra Low NOx quick service guide, p. 1)
- Replace gas control if the code persists. (Service manual 238-51546-00C, p. 7)
-
The gas control’s electronics found a fault.Seven flashes and three second pause
The gas control’s electronics found a fault. Sometimes a reset fixes it; if it comes back, the gas control is replaced. (Service manual 238-51542-00E, p. 10)
By model: IMPORTANT: on standing-pilot (atmospheric and direct vent) Defender tanks, 7 flashes is a gas control fault, NOT the flammable vapor sensor. The 7-flash flammable vapor sensor code belongs to power vent, damper and RG2F models (see 7 blinks, ei- families).
Likely causes
- Control needs to be reset. (Service manual 238-51542-00E, p. 10)
- Control is wet or physically damaged. (Service manual 238-51542-00E, p. 10)
What you can check
- Turn the set point knob to OFF, then to PILOT, and light the pilot. (Owner’s manual 238-51012-00T, p. 23)
- Look for water dripping onto the gas control (a wet control causes this code). (Owner’s manual 238-51012-00T, p. 23)
For a technician
- Replace gas valve if seven flash error persists. (Owner’s manual 238-51012-00T, p. 23)
-
The pilot is still burning even though the knob is set to OFF.Eight flashes and three second pause
The pilot is still burning even though the knob is set to OFF. The pilot valve is stuck open, so the gas control must be replaced. (Service manual 238-51542-00E, p. 10)
By model: Owner’s manuals and the pre-2015 ECO-Defender chart word it 'False pilot flame present.'
Likely causes
- Pilot valve stuck in open position. (Service manual 238-51542-00E, p. 10)
What you can check
- Owner’s manual: turn the set point knob to OFF, then to PILOT and light the pilot; if eight flashes persist the gas valve must be replaced by a technician. (Owner’s manual 238-51012-00T, p. 23)
For a technician
- Check gas pressure, then replace the gas control. (Atmospheric quick service guide, p. 1)
-
On Ultra Low NOx V2 controls, the leak-detection accessory found water.Nine flashes and three second pause (LED red)
On Ultra Low NOx V2 controls, the leak-detection accessory found water. The control recovers when the module clears. (Service manual 238-51546-00C, p. 9)
Likely causes
- Control recovers after receiving message from accessory module. (Service manual 238-51546-00C, p. 9)
What you can check
- Look for water in the drain pan and at the relief valve and water fittings. (Service manual 238-51546-00C, p. 9)
For a technician
- Check the T&P valve, check all water fittings, pressurize and leak test the tank. (Service manual 238-51546-00C, p. 9)
-
Ultra Low NOx tanks only: the burner is not getting enough air, usually from lint, dust or oil clogging the air openings, burner screen or flame arrestor.Ten flashes and three second pause (V2: LED red)
Ultra Low NOx tanks only: the burner is not getting enough air, usually from lint, dust or oil clogging the air openings, burner screen or flame arrestor. (Service manual 238-51546-00C, p. 7)
By model: V2 wording: 'Abnormal combustion chamber temperature profile during heating cycle.' Pre-2015 ECO-Defender: 'Insufficient combustion air detected. Reset system.' (bw-47132a p. 6). Not on standard (non-ULN) tanks. The 2024 URG owner’s manual V1 table omits it (bw-53393).
Likely causes
- Insufficient combustion air. (Service manual 238-51546-00C, p. 7)
- V2: Abnormal combustion chamber temperature profile during heating cycle. (Service manual 238-51546-00C, p. 9)
- Dirty ScreenLok, venting problem, dirty burner or gas pressure. (Ultra Low NOx quick service guide, p. 1)
What you can check
- Remove all obstacles that may restrict air flow to the burner (stored items, lint, dust at the jacket door openings). (Service manual 238-51546-00C, p. 9)
- Keep the air slots in the outer jacket open: clear away lint, dust and anything stored against the heater. Keep gasoline, paint thinner and other flammable products away from it. (Owner’s manual 238-51012-00T, p. 21)
For a technician
- Reset gas control; replace gas control if the code returns. (Service manual 238-51546-00C, p. 7)
- Clean the burner screen and venturi with a stiff brush, compressed air or shop vacuum. (Service manual 238-51546-00C, p. 10)
- Clean the ScreenLok flame arrestor (burner out). (Service manual 238-51546-00C, p. 27)
- Check venting and gas pressure. (Ultra Low NOx quick service guide, p. 1)
Power vent, damper and other electronic-ignition tanks
Power vent and power direct vent, eF Series, D Series damper and RG2F tanks. Some codes are two sets of blinks, like 6 then 1.
-
No electrical power reaches the control: the switch on the gas control is off, the heater is unplugged, or the outlet or breaker has no power.None, control LED not on or flashing
No electrical power reaches the control: the switch on the gas control is off, the heater is unplugged, or the outlet or breaker has no power. (Service manual 238-51540-00E, p. 15)
Likely causes
- Control power switch in OFF position. (Service manual 238-51540-00E, p. 15)
- Supply voltage interrupted. (Service manual 238-51540-00E, p. 15)
What you can check
- Make sure the heater is plugged in, the breaker is on, and the power switch on the gas control is ON. (Service manual 238-51540-00E, p. 15)
For a technician
- Verify 120 volts present at outlet. (Power vent quick service guide, p. 1)
- 115 VAC circuit trace: verify voltage and correct polarity at the outlet, then LED status with power on. (Service manual 238-51540-00E, p. 35)
-
Normal.Short flash, once every four seconds
Normal. The tank is up to temperature and the heater is waiting. (Service manual 238-51540-00E, p. 15)
By model: The URG damper chart lists standby as 'One short flash, once every two seconds' (bw-51673 p. 11) while its own sequence text says every 4 seconds (p. 9).
-
Not a fault.One short flash every two seconds
Not a fault. The heater is in idle or Sabbath mode, set by an accessory module, so the burner is held off. (Service manual 238-51617-00C, p. 12)
By model: RG2F: 'Stand-by mode. Sabbath mode (no faults)'. Power vent owner’s manual: 'Idle remote command off'. URG damper chart uses this pattern for normal standby.
Likely causes
- Control put in idle or Sabbath mode from accessory module (power vent owner’s manual). (Owner’s manual 238-54331-00B, p. 32)
What you can check
- If the heater should be running, check the setting of any connected accessory or controller that can put it in idle/Sabbath mode. (Owner’s manual 238-54331-00B, p. 32)
-
Normal."Heartbeat" alternates bright/dim
Normal. The heater is calling for heat and running a heating cycle. (Service manual 238-51540-00E, p. 15)
-
A warning, not a lockout: on the last heating cycle the pilot flame signal was weak.Short flash once per second
A warning, not a lockout: on the last heating cycle the pilot flame signal was weak. Left alone it can turn into failed-ignition codes. (Service manual 238-51540-00E, p. 15)
By model: Opposite of the standing-pilot V2/SIT controls, where one flash per second is normal heating.
Likely causes
- Unstable pilot. (Service manual 238-51540-00E, p. 15)
- Pilot tube blocked or restricted. (Service manual 238-51540-00E, p. 15)
- Oxidation build up on pilot electrode. (Service manual 238-51540-00E, p. 15)
- Wire damage to pilot assembly or bad connection at gas valve. (Service manual 238-51540-00E, p. 15)
- Low gas pressure (eF Series). (Service manual 238-51526-00B, p. 14)
For a technician
- Pilot inspection: check igniter/flame-sense wire for damage and continuity, set electrode gap to 3/32 in. from the hood, clean oxidation with fine emery cloth, check pilot tube and orifice for blockage. (Service manual 238-51540-00E, p. 19)
- Burner inspection: blue flame, minimal yellow tips; unstable pilot can come from vent shorter than allowed, gas pressure out of spec, or pilot flame not engulfing the sensor. (Service manual 238-51540-00E, p. 17)
-
At the start of a heating call the air-pressure switch is already closed before the blower runs, so the control will not start.Two flash, three second pause - pressure switch closed
At the start of a heating call the air-pressure switch is already closed before the blower runs, so the control will not start. It retries every 2 minutes. (Service manual 238-51540-00E, p. 15)
By model: Sequence: control waits 2 minutes, runs the blower 30 seconds, and repeats until the switch opens (bw-51540 p. 11). On damper models 2 flashes mean a damper fault (next entry).
Likely causes
- Pressure switch tubing kinked or blocked. (Service manual 238-51540-00E, p. 15)
- Blocked pressure tap on switch or blower. (Service manual 238-51540-00E, p. 15)
- Faulty pressure switch. (Service manual 238-51540-00E, p. 15)
For a technician
- Pressure switch testing: inspect tubing and ports, measure vacuum at the switch, replace the switch if faulty. (Service manual 238-51540-00E, p. 20)
- Inspect pressure switch tubing and ports; bypass pressure switch and temp switch only for testing. (Power vent quick service guide, p. 1)
-
On flue-damper models: the damper circuit says the damper is open when it should be closed (damper stuck open).Two flash, three second pause - damper (D Series)
On flue-damper models: the damper circuit says the damper is open when it should be closed (damper stuck open). (Service manual 238-51637-00C, p. 11)
Likely causes
- Damper stuck in open position. (Service manual 238-51637-00C, p. 11)
- Obstructed venting. (Service manual 238-51637-00C, p. 11)
- Faulty damper. (Service manual 238-51637-00C, p. 11)
What you can check
- Verify the damper cord sets are fully plugged in and the switch on the damper is in the 'Automatic' position. (Service manual 238-51637-00C, p. 11)
For a technician
- Check damper and vent for blockage, verify voltage to the damper, replace damper if faulty. (Damper quick service guide, p. 1)
-
The blower ran but the safety circuit never closed: the vent may be blocked, the blower may not be up to speed, or a switch is bad.Three flash, three second pause - pressure switch or blower temperature switch open
The blower ran but the safety circuit never closed: the vent may be blocked, the blower may not be up to speed, or a switch is bad. The blower retries for 30 seconds every 2 minutes. (Service manual 238-51540-00E, p. 15)
By model: RG2F wording adds 'Blower not spinning up to speed' with cords to check (bw-51617 p. 12). Damper models: see next entry.
Likely causes
- Vent blockage or improper vent configuration. (Service manual 238-51540-00E, p. 15)
- Pressure switch tubing kinked or blocked. (Service manual 238-51540-00E, p. 15)
- Faulty pressure switch. (Service manual 238-51540-00E, p. 15)
- Blower not spinning up to speed. (Service manual 238-51540-00E, p. 15)
- Blower temp or exhaust temp too high. (Service manual 238-51540-00E, p. 15)
- Faulty blower temperature switch. (Service manual 238-51540-00E, p. 15)
- PDX power direct vent: intake vent length exceeds exhaust vent length; frozen intake or exhaust vent terminal. (Service manual 238-49770-00B, p. 13)
What you can check
- Go outside and look at the vent (and intake) termination for blockage: bird nests, leaves, snow, ice. (Service manual 238-51540-00E, p. 15)
For a technician
- Check the vent against the vent tables (length, elbows, diameter). (Service manual 238-51540-00E, p. 15)
- Pressure switch testing: inspect tubing and ports, measure vacuum at the switch, replace the switch if faulty. (Service manual 238-51540-00E, p. 20)
- Blower testing (verify it spins up to speed). (Service manual 238-51540-00E, p. 22)
- Blower temperature switch: normally closed, opens at 155 F, auto-resets about 135 F; test and replace if faulty. (Service manual 238-51540-00E, p. 24)
- The quick guide lists bypassing the pressure switch and temperature switch FOR TESTING ONLY; the heater must never be operated with jumpered controls. (Power vent quick service guide, p. 1)
-
On flue-damper models: the damper did not open all the way, so the burner is not allowed to light.Three flash, three second pause - damper not fully open (D Series)
On flue-damper models: the damper did not open all the way, so the burner is not allowed to light. (Service manual 238-51637-00C, p. 11)
Likely causes
- Damper not reaching full open position. (Service manual 238-51637-00C, p. 11)
- Obstructed venting. (Service manual 238-51637-00C, p. 11)
- Faulty damper. (Service manual 238-51637-00C, p. 11)
What you can check
- Verify the damper cord sets are fully plugged in and the switch on the damper is in the 'Automatic' position. (Service manual 238-51637-00C, p. 11)
For a technician
- Check damper/vent for blockage, verify voltage to damper, bypass damper for testing only, replace damper. (Damper quick service guide, p. 1)
-
The water got too hot and the safety cutoff (ECO) shut off the gas.Four flash, three second pause
The water got too hot and the safety cutoff (ECO) shut off the gas. The blower keeps running until the control is reset. (Service manual 238-51540-00E, p. 15)
By model: ECO limit about 188 F residential (bw-51540 p. 6).
Likely causes
- Temperature sensor out of calibration. (Service manual 238-51540-00E, p. 15)
- Faulty gas control. (Service manual 238-51540-00E, p. 15)
- Plumbing leak. (Service manual 238-51540-00E, p. 15)
- Excessive sediment; hot water entering the tank from another source in the potable loop (owner’s manual). (Owner’s manual 238-54331-00B, p. 32)
- Tank not filled with water (pre-2015 TTW). (Service manual 238-46238A-00A, p. 13)
What you can check
- Ask whether hot water from another source can flow back into the tank; the guide says verify no heat migration in plumbing system. (Quick service guide 238-55597-00A, p. 1)
For a technician
- Reset: rotate the temperature knob to the minimum setting for at least 6 seconds, then back to the desired setting. (Service manual 238-51540-00E, p. 13)
- Temperature sensor test with pin probes against the resistance chart after measuring drained water temperature. (Service manual 238-51540-00E, p. 30)
- Replace the gas control. (Service manual 238-51540-00E, p. 31)
-
The control sees a pilot flame when there should be none.Five flash, three second pause
The control sees a pilot flame when there should be none. The pilot valve may be stuck open. (Service manual 238-51540-00E, p. 15)
By model: When the false flame goes away the control changes to 6-4 flashes and waits 5 minutes (bw-51540 p. 14).
Likely causes
- Pilot valve stuck in open position. (Service manual 238-51540-00E, p. 15)
For a technician
- Check the flame sensor for a short to ground; replace the gas valve if stuck open. (Power vent quick service guide, p. 1)
- Replace the gas control. (Service manual 238-51540-00E, p. 31)
-
The pilot did not light within the 90-second trial.Six-one flash, three second pause
The pilot did not light within the 90-second trial. The heater waits 5 minutes and tries again. (Service manual 238-51540-00E, p. 16)
Likely causes
- Unstable pilot. (Service manual 238-51540-00E, p. 16)
- Pilot tube blocked or restricted. (Service manual 238-51540-00E, p. 16)
- Oxidation build up on pilot electrode. (Service manual 238-51540-00E, p. 16)
- Wire damage to pilot assembly or bad connection at gas valve. (Service manual 238-51540-00E, p. 16)
- Low gas pressure (eF Series). (Service manual 238-51526-00B, p. 15)
What you can check
- Make sure gas is reaching the heater: the gas shutoff valve to the heater is open (other gas appliances working is a good sign). (Power vent quick service guide, p. 1)
For a technician
- Pilot inspection: check igniter/flame-sense wire for damage and continuity, set electrode gap to 3/32 in. from the hood, clean oxidation with fine emery cloth, check pilot tube and orifice for blockage. (Service manual 238-51540-00E, p. 19)
- Verify gas flow and check the connection at the gas valve. (Power vent quick service guide, p. 1)
-
While the burner was running, the vent safety circuit opened (vent blocked, wind, blower slowing, or a switch).Six-two flash, three second pause - pressure switch / blower temp switch opened while running
While the burner was running, the vent safety circuit opened (vent blocked, wind, blower slowing, or a switch). After 4 tries the heater waits 5 minutes. (Service manual 238-51540-00E, p. 16)
By model: Damper models use 6-2 for the damper (next entry).
Likely causes
- Vent blockage or improper vent configuration. (Service manual 238-51540-00E, p. 16)
- Vent termination being affected by wind. (Service manual 238-51540-00E, p. 16)
- Blower not spinning up to speed; blower or exhaust temperature too high; faulty pressure or blower temperature switch. (Service manual 238-51540-00E, p. 16)
- eF condensing models: blocked condensate trap. (Service manual 238-51526-00B, p. 15)
- PDX: insufficient combustion air. (Service manual 238-49770-00B, p. 14)
- RG2F: damper inside blower not fully opening. (Service manual 238-51617-00C, p. 13)
What you can check
- Go outside and look at the vent (and intake) termination for blockage: bird nests, leaves, snow, ice. (Service manual 238-51540-00E, p. 15)
- eF Series: check that water can flow through the condensate drain line; clear an obstruction in the outside drain line. (Service manual 238-51526-00B, p. 39)
For a technician
- Pressure switch testing: inspect tubing and ports, measure vacuum at the switch, replace the switch if faulty. (Service manual 238-51540-00E, p. 20)
- Blower and blower temperature switch tests. (Service manual 238-51540-00E, p. 22)
- eF: remove and clean the condensate trap/tee. (Service manual 238-51526-00B, p. 39)
-
On flue-damper models: the damper moved off full open during the heating cycle.Six-two flash, three second pause - damper moved while running (D Series)
On flue-damper models: the damper moved off full open during the heating cycle. The heater retries after 5 minutes. (Service manual 238-51637-00C, p. 12)
Likely causes
- Damper moved from full open position during run cycle. (Service manual 238-51637-00C, p. 12)
- Obstructed venting. (Service manual 238-51637-00C, p. 12)
- Faulty damper. (Service manual 238-51637-00C, p. 12)
- Damper jostled during run cycle. (Service manual 238-51637-00C, p. 12)
What you can check
- Make sure nothing is bumping or resting on the damper and its cords are plugged in. (Service manual 238-51637-00C, p. 12)
For a technician
- Check damper/vent for blockage, verify voltage, bypass damper for testing only, replace damper. (Damper quick service guide, p. 1)
-
The pilot flame went out during operation.Six-three flash, three second pause
The pilot flame went out during operation. After 4 relight tries the heater waits 5 minutes. (Service manual 238-51540-00E, p. 16)
Likely causes
- Unstable pilot; pilot tube blocked; oxidation on electrode; wire damage or bad connection at gas valve. (Service manual 238-51540-00E, p. 16)
- Insufficient combustion air. (Service manual 238-51540-00E, p. 16)
- Gas pressure is out of specification. (Service manual 238-51540-00E, p. 16)
What you can check
- Make sure nothing blocks the air openings at the bottom of the jacket and the room has its required combustion air openings. (Service manual 238-51540-00E, p. 16)
For a technician
- Pilot inspection: check igniter/flame-sense wire for damage and continuity, set electrode gap to 3/32 in. from the hood, clean oxidation with fine emery cloth, check pilot tube and orifice for blockage. (Service manual 238-51540-00E, p. 19)
- Gas pressure test: line pressure max 14.0 in. w.c.; manifold 4.0 +/-0.5 in. w.c. natural gas, 10.0 +/-0.5 in. w.c. LP; manifold pressure is not adjustable. (Service manual 238-51540-00E, p. 26)
-
The control sensed a pilot flame out of sequence (pilot valve stuck open).Six-four flash, three second pause
The control sensed a pilot flame out of sequence (pilot valve stuck open). It waits 5 minutes before trying again. (Service manual 238-51540-00E, p. 16)
Likely causes
- Pilot valve stuck in open position. (Service manual 238-51540-00E, p. 16)
For a technician
- Check for flame sensor short to ground; replace the gas valve if stuck open. (Power vent quick service guide, p. 1)
- Replace the gas control. (Service manual 238-51540-00E, p. 31)
-
Flammable vapor sensor lockout.Seven flash, three second pause - FLAMMABLE VAPOR SENSOR (FV sensor) fault / lockout
Flammable vapor sensor lockout. The FV sensor reading is out of range, so the heater locks out and will not light. Causes: gasoline or solvent fumes near the heater, a wet or overheated sensor, bad wiring, or (some models) a tripped thermal switch. (Service manual 238-51540-00E, p. 16)
By model: This is the Bradford White 'flammable vapor sensor lockout'. It exists only on electronic-ignition models that have an FV sensor: power vent / power direct vent RG-LG PV & PDV, Ultra Low NOx power vent, D Series damper, URG D, RG2F and pre-2015 TTW/PDX. RG1PV55H and RG2PV75H use a simulated resistive device instead of a sensor (bw-51540 p. 11). On eF Series condensing models 7 flashes means a simulated-resistive-device fault (next entry). On standing-pilot atmospheric tanks 7 flashes is a gas control fault. Lockout: indefinite, cycle power to restart (bw-51540 p. 10). The sequence-of-operation text adds a two-part version: above 65,000 ohms the control 'flashes 7 times, then once' (7-1) during a 2-minute verify delay, repeated up to 5 times before the lockout (bw-51540 p. 12; bw-51637 p. 9); the charts and quick guides list only 'Seven flashes'.
Likely causes
- Flammable vapor present. (Owner’s manual 238-54331-00B, p. 33)
- Flammable vapor sensor exposed to excessive moisture. (Owner’s manual 238-54331-00B, p. 33)
- Flammable vapor sensor exposed to extreme ambient temperature. (Owner’s manual 238-54331-00B, p. 33)
- Resettable thermal switch open (Ultra Low NOx power vent, D Series, RG2F). (Service manual 238-51548-00D, p. 15)
- Sensor resistance above 70,000 ohms: control retries every 2 minutes up to 5 times, then goes into flammable vapor lockout. (Service manual 238-51540-00E, p. 12)
- Pre-2015 power vent: indicates gasoline vapors were detected at potentially explosive levels. (Service manual 238-46238A-00A, p. 14)
What you can check
- Check for gasoline, paint, thinner, solvents or other flammable products near the heater. Remove them and air out the area. If you smell gas, follow the gas-smell instructions instead. (Service manual 238-46238A-00A, p. 14)
- Look for water or a wet floor around the base of the heater (a wet sensor causes this code). (Owner’s manual 238-54331-00B, p. 33)
- Only after any vapors are gone: reset by cycling power (unplug/replug or the gas control ON/OFF switch). The lockout does not clear by itself. (Service manual 238-51540-00E, p. 10)
For a technician
- Flammable vapor sensor test: power OFF, unplug the sensor, measure with pin probes; must be 3,000-48,000 ohms, otherwise replace the sensor. (Service manual 238-51540-00E, p. 33)
- RG2F: measure both the flammable vapor sensor and the resettable thermal switch (left two pins); both must be 3,000-48,000 ohms; if the switch has not tripped and is out of range, replace it. (Service manual 238-51617-00C, p. 22)
- Check sensor harness. (Power vent quick service guide, p. 1)
- Resettable thermal switch testing. (Service manual 238-51548-00D, p. 15)
- Replace the Flammable Vapor Sensor element if a gasoline spill event occurred. (Service manual 238-46238A-00A, p. 14)
- D Series / URG D: check continuity on the temp limit and clean the intake screen. (Quick service guide 238-55599-00A, p. 1)
-
eF Series condensing models have no vapor sensor; a resistor plug stands in for it.Seven flash, three second pause - simulated resistive device (eF Series)
eF Series condensing models have no vapor sensor; a resistor plug stands in for it. Its harness is out of range or unplugged, so the heater locks out. (Service manual 238-51526-00B, p. 15)
Likely causes
- Simulated resistance device harness out of specification or disconnected. (Service manual 238-51526-00B, p. 15)
What you can check
- Cycle power once (lockout is indefinite until power is cycled). (Service manual 238-51526-00B, p. 9)
For a technician
- Measure the simulated resistive device: must be 3,000-48,000 ohms; replace if out of range. (Service manual 238-51526-00B, p. 29)
-
The flammable vapor sensor reads too LOW (possible short in the sensor or its wiring).Eight-one flash, three second pause - flammable vapor sensor out of specification
The flammable vapor sensor reads too LOW (possible short in the sensor or its wiring). The code clears by itself if the reading returns to normal for 15 seconds. (Service manual 238-51540-00E, p. 16)
Likely causes
- Resistance below 3000 ohms: control turns off all outputs; self clears if back in range for at least 15 seconds. (Service manual 238-51540-00E, p. 12)
- RG2F: verify FVS resistance is not below 25,000 ohms; possible short in flammable vapor sensor or resettable thermal switch wiring. (Service manual 238-51617-00C, p. 13)
- Pre-2015: check wiring to FVS and insure it is not shorted; replace control if everything checks out OK. (Service manual 238-46238A-00A, p. 14)
What you can check
- Check that no flammable vapors are present near the heater. (Power vent quick service guide, p. 1)
For a technician
- Verify sensor resistance is between 3.0-48 kOhms and check the sensor harness; replace sensor, harness or gas valve as needed. (Power vent quick service guide, p. 1)
-
eF Series: the stand-in resistor for the vapor sensor reads out of range, possibly shorted.Eight-one flash, three second pause - simulated resistive device (eF Series)
eF Series: the stand-in resistor for the vapor sensor reads out of range, possibly shorted. (Service manual 238-51526-00B, p. 15)
For a technician
- Measure the simulated resistive device (3,000-48,000 ohms); replace if out of range. (Service manual 238-51526-00B, p. 29)
-
The control’s tank temperature sensor (in the gas control’s thermal well) is damaged, unplugged or out of range.Eight-two flash, three second pause
The control’s tank temperature sensor (in the gas control’s thermal well) is damaged, unplugged or out of range. Clears by itself if the fault clears for 15 seconds. (Service manual 238-51540-00E, p. 16)
By model: CONFLICT inside the manuals: the sequence-of-operation text in bw-51540/51637/51673 says an open temperature sensor flashes 8 then 3, but every troubleshooting chart and the 2019+ quick service guides (bw-55597 'Gas valve temp probe fault', bw-55599 'Thermowell sensor damaged or unplugged') list temperature sensor as 8-2 (RG2F sequence text also says 8-2, bw-51617 p. 9). Pre-2015 WV4460E controls have no 8-2 (see 8-3).
Likely causes
- Damage to temperature sensor wire. (Service manual 238-51540-00E, p. 16)
- Temperature sensor resistance out of range. (Service manual 238-51540-00E, p. 16)
- Sensor readings disagree by more than about 5.5 F, or open circuit. (Service manual 238-51540-00E, p. 12)
What you can check
- The quick guide’s first step is to reset the gas valve (switch off, then on); the gas valve is replaced if the fault persists. (Quick service guide 238-55597-00A, p. 1)
For a technician
- Temperature sensor test with pin probes (center pin to each outside pin) against the resistance chart. (Service manual 238-51540-00E, p. 29)
- Replace the gas control. (Service manual 238-51540-00E, p. 31)
-
The gas control’s electronics found an internal fault.Eight-three flash, three second pause - gas valve electronics (current controls)
The gas control’s electronics found an internal fault. Try one power reset; if it returns, the control is replaced. (Service manual 238-51540-00E, p. 16)
By model: On pre-2015 WV4460E power vents 8-3 means thermal well sensor (next entry).
Likely causes
- Control needs to be reset. (Service manual 238-51540-00E, p. 16)
- Control is wet or physically damaged. (Service manual 238-51540-00E, p. 16)
What you can check
- Turn the gas control power switch off, wait, then back on (interrupt the power supply). (Service manual 238-51540-00E, p. 16)
- Verify control is not wet or physically damaged (look for water dripping on it). (Owner’s manual 238-54331-00B, p. 33)
For a technician
- Replace electronic module if 8-3 error persists. (Owner’s manual 238-54331-00B, p. 33)
-
On older (before 2015) power vent tanks, 8-3 means the tank temperature sensor in the gas control’s well is damaged or unplugged.Eight-three flash, three second pause - thermal well sensor (pre-2015 power vent)
On older (before 2015) power vent tanks, 8-3 means the tank temperature sensor in the gas control’s well is damaged or unplugged. PDX and ULN TTW charts add 'or gas control electronics fault'. (Service manual 238-46238A-00A, p. 14)
Likely causes
- Damage to thermal well wire. (Service manual 238-46238A-00A, p. 14)
- Thermal well sensor resistance out of range. (Service manual 238-46238A-00A, p. 14)
- Or gas valve electronics fault detected (PDX). (Service manual 238-49770-00B, p. 14)
What you can check
- Reset control on/off switch. (Service manual 238-48509-00A, p. 19)
For a technician
- Thermal well testing with pin probes against the resistance chart; replace thermal well if wrong, otherwise replace the gas control. (Service manual 238-46238A-00A, p. 24)
-
The gas control found a gas valve fault.Eight-four flash, three second pause
The gas control found a gas valve fault. Try one power reset; if it returns, the gas control is replaced. (Service manual 238-51540-00E, p. 16)
Likely causes
- Control needs to be reset. (Service manual 238-51540-00E, p. 16)
- Control is wet or physically damaged. (Service manual 238-51540-00E, p. 16)
What you can check
- Turn the gas control power switch off, wait, then back on (interrupt the power supply). (Service manual 238-51540-00E, p. 16)
- Verify control is not wet or physically damaged. (Owner’s manual 238-54331-00B, p. 33)
For a technician
- Replace gas control if 8-4 error persists. (Owner’s manual 238-54331-00B, p. 33)
-
Ultra Low NOx damper models: the burner is not getting enough air (dirty flame arrestor, blocked openings).Nine-One flash, three second pause
Ultra Low NOx damper models: the burner is not getting enough air (dirty flame arrestor, blocked openings). (Service manual 238-51673-00D, p. 13)
What you can check
- Keep jacket air openings clear of lint, dust and stored items. (Service manual 238-51673-00D, p. 37)
For a technician
- Clean the ScreenLok flame arrestor and clear jacket openings (burner removed). (Service manual 238-51673-00D, p. 37)
-
Ultra Low NOx damper models: the combustion chamber door sensor reads out of range or is shorted.Nine-two flash, three second pause
Ultra Low NOx damper models: the combustion chamber door sensor reads out of range or is shorted. (Service manual 238-51673-00D, p. 13)
Likely causes
- Chamber sensor out of calibration. (Service manual 238-51673-00D, p. 13)
- Possible short. (Service manual 238-51673-00D, p. 13)
For a technician
- Chamber sensor test: measure with pin probes at the ring terminal temperature vs. chart; replace the flammable vapor/chamber sensor harness if out of range. (Service manual 238-51673-00D, p. 34)
Electric tanks with ICON E
Green, amber or red blinks on the ICON E control.
-
The control has no power.OFF (LED not flashing)
The control has no power. The breaker may be off, or a connector inside is loose. (Service manual 238-55036-00A, p. 7)
Likely causes
- Power is not connected to water heater. (Service manual 238-55036-00A, p. 7)
- Control power connector is disconnected. (Service manual 238-55036-00A, p. 7)
What you can check
- Check the fuses or circuit breakers in the service panel. (Service manual 238-55036-00A, p. 12)
For a technician
- Inspect the connectors behind the Control Module and the High Limit wiring; replace the Control Module if the problem persists. (Service manual 238-55036-00A, p. 8)
-
Normal start-up self-test (StartGuard) that checks the tank is full before the elements run.Alternating Green and Amber Flashes
Normal start-up self-test (StartGuard) that checks the tank is full before the elements run. It should finish in about 5 minutes. (Service manual 238-55036-00A, p. 7)
Likely causes
- If it lasts much longer than 5 minutes there may be air in the tank or the control may be damaged. (Service manual 238-55036-00A, p. 7)
What you can check
- Make sure the tank is full: open hot water faucets until water runs from all of them (purge air). (Quick guide 238-54399-00B, p. 1)
For a technician
- Check that the Power Switch Module is tightly coupled to the tank wall; replace the Control Module if the code persists. (Service manual 238-55036-00A, p. 8)
-
Normal.Solid Green
Normal. The tank is up to temperature. (Service manual 238-55036-00A, p. 7)
What you can check
- If it is solid green but there is no hot water, move the setpoint knob around and back to the desired setting to start a heating cycle. (Service manual 238-55036-00A, p. 8)
-
Normal.1 Flash Green then off for 4 seconds
Normal. An element is heating the water. (Service manual 238-55036-00A, p. 7)
-
A heating element is bad (burned out or not working).2 Flashes Amber then off for 4 seconds
A heating element is bad (burned out or not working). (Service manual 238-55036-00A, p. 7)
Likely causes
- Element malfunction. (Service manual 238-55036-00A, p. 7)
For a technician
- Power off; check each element: about 12.8 ohms (+/-6%) for a 240 V 4500 W element, and no continuity to the flange (grounded element); drain and replace bad elements. (Service manual 238-55036-00A, p. 15)
-
The Power Switch Module (lower module that switches the elements) is loose on the tank or not working.3 Flashes Amber then off for 4 seconds
The Power Switch Module (lower module that switches the elements) is loose on the tank or not working. (Service manual 238-55036-00A, p. 7)
Likely causes
- Power Switch Module is not tightly coupled to tank wall. (Service manual 238-55036-00A, p. 7)
- Power Switch Module is not functioning correctly. (Service manual 238-55036-00A, p. 7)
For a technician
- Check the 5-pin and 3-pin connectors; measure terminals 1-2 and 1-3 on the PSM (about 50-80 Mohm each); replace the PSM if low or uneven. (Service manual 238-55036-00A, p. 9)
-
A temperature sensor is disconnected, or the high-limit (ECO) has tripped open.4 Flashes Amber then off for 4 seconds
A temperature sensor is disconnected, or the high-limit (ECO) has tripped open. (Service manual 238-55036-00A, p. 7)
Likely causes
- Upper Temperature Sensor is disconnected. (Service manual 238-55036-00A, p. 7)
- Power Switch Module disconnected. (Service manual 238-55036-00A, p. 7)
- High Temperature limit has switched open. (Service manual 238-55036-00A, p. 7)
For a technician
- Check connectors; measure the upper sensor (about 1.2 kOhm hot to 33 kOhm cold); replace the upper sensor and, if needed, the Power Switch Module. (Service manual 238-55036-00A, p. 9)
-
The ICON E control board has a fault.5 Flashes Amber then off for 4 seconds
The ICON E control board has a fault. (Service manual 238-55036-00A, p. 7)
Likely causes
- Controller not functioning properly. (Service manual 238-55036-00A, p. 7)
What you can check
- Move the setpoint knob back and forth several times, then cycle power to the water heater. (Service manual 238-55036-00A, p. 9)
For a technician
- Replace the control module if the problem persists. (Service manual 238-55036-00A, p. 9)
-
Not a fault.6 Flashes Amber then off for 4 seconds
Not a fault. A utility demand-response device (CTA-2045 module) is holding the heater back to save grid power. (Service manual 238-55036-00A, p. 7)
What you can check
- If the tank is too cold, move the setpoint knob and return it to its setting; the heater runs normally for 72 hours. (Service manual 238-55036-00A, p. 5)
-
A sensor found the water too hot.7 Flashes Red then off for 4 seconds
A sensor found the water too hot. The high-limit (ECO) may have tripped. (Service manual 238-55036-00A, p. 7)
Likely causes
- Upper or lower temperature sensor has detected an excessive temperature. (Service manual 238-55036-00A, p. 7)
- Repeated ECO trips are usually a grounded heating element. (Service manual 238-55036-00A, p. 11)
For a technician
- Power off, make sure the tank is full of cold water, check whether the High Limit (ECO) tripped (press its reset button), test upper sensor and PSM, and check elements. (Service manual 238-55036-00A, p. 10)
AeroTherm heat pump water heaters
F codes on the display.
-
The compressor outlet temperature did not rise as expected after the compressor started.FA (heat pump fault, RE2H50R10)
The compressor outlet temperature did not rise as expected after the compressor started. (Quick guide 238-50804-00A, p. 2)
By model: Listed only in the first-generation RE2H50R10 guide.
For a technician
- Check T4 sensor mounting, wiring and resistance; check EEV operation; check sealed system for refrigerant leak. (Quick guide 238-50804-00A, p. 2)
-
Compressor outlet temperature stayed too low while running.Fb (RE2H50R10)
Compressor outlet temperature stayed too low while running. (Quick guide 238-50804-00A, p. 2)
By model: First-generation RE2H50R10 only.
For a technician
- Check T4 sensor; in cold climates insulate T4 sensor with mastic; check EEV and refrigerant charge; recommend Hybrid or High Demand mode in cold climates. (Quick guide 238-50804-00A, p. 2)
-
A heat pump (compressor/fan/sensor) problem.Owner guide: heater beeping, screen says 'FA-F8'
A heat pump (compressor/fan/sensor) problem. The heater switches to another mode so you still get hot water. (Quick guide 238-52324-00B, p. 9)
By model: Owner-guide shorthand for the heat-pump fault group.
What you can check
- The unit switches to another available mode; contact service and give them the codes shown on the display. (Quick guide 238-52324-00B, p. 9)
-
The evaporator coil may be frosting up (inlet temperature stayed below 20 F after 30 minutes).FC
The evaporator coil may be frosting up (inlet temperature stayed below 20 F after 30 minutes). (Installation manual 238-52169-00C, p. 28)
For a technician
- Check T3a sensor mounting, wiring and resistance; check Electronic Expansion Valve (EEV); check sealed system for refrigerant leak. (Quick guide 31-75036-1, p. 2)
-
Evaporator superheat is out of range (refrigerant flow problem).Fd
Evaporator superheat is out of range (refrigerant flow problem). (Installation manual 238-52169-00C, p. 28)
What you can check
- Check that the air filter is clean (clean it if the filter light is on). (Quick guide 31-75036-1, p. 2)
For a technician
- Check T3a, T3b and T5 sensors; check EEV operation; check for refrigerant leak. (Quick guide 31-75036-1, p. 2)
-
The compressor outlet got hotter than 240 F.FE
The compressor outlet got hotter than 240 F. (Installation manual 238-52169-00C, p. 28)
For a technician
- Check T4 sensor mounting, wiring and resistance; check EEV; check for refrigerant leak. (Quick guide 31-75036-1, p. 2)
-
The electronic expansion valve is not moving within its normal range.FF
The electronic expansion valve is not moving within its normal range. (Installation manual 238-52169-00C, p. 28)
For a technician
- Check EEV operation; check T3a and T3b sensors; check for refrigerant leak. (Quick guide 31-75036-1, p. 2)
-
Room air is outside the heat pump’s range, so the heater uses electric elements for that cycle.FG (not displayed)
Room air is outside the heat pump’s range, so the heater uses electric elements for that cycle. Not a failure. (Installation manual 238-52169-00C, p. 28)
By model: Range 35-120 F on RE2H50S/65T/80T (bw-52169 p. 28) and RE2H50/80 R10B (bw-75036 p. 2); 45-120 F on the first-generation RE2H50R10 (bw-50804 p. 2).
-
High compressor load in hot rooms; the control switches to electric for that cycle and counts it.FH (not displayed, RE2H50R10)
High compressor load in hot rooms; the control switches to electric for that cycle and counts it. Information only. (Quick guide 238-50804-00A, p. 2)
-
Early warning of a possible refrigerant leak (superheat and EEV position out of limits).FI* (some models)
Early warning of a possible refrigerant leak (superheat and EEV position out of limits). (Installation manual 238-52169-00C, p. 28)
For a technician
- Check sealed system for refrigerant leak; check T3a, T3b, T5 sensors; check EEV. (Quick guide 31-75036-1, p. 2)
-
Too much current with the compressor and lower element on together; the compressor is shut off.FJ
Too much current with the compressor and lower element on together; the compressor is shut off. (Installation manual 238-52169-00C, p. 28)
By model: Not in the first-generation RE2H50R10 guide.
For a technician
- Check lower heating element rated wattage (stamped on the element) against the rating plate. (Quick guide 31-75036-1, p. 2)
-
Defrost check failed: evaporator temperatures did not match room temperature after defrost.FL
Defrost check failed: evaporator temperatures did not match room temperature after defrost. (Installation manual 238-52169-00C, p. 28)
For a technician
- Check T3a, T3b, T5 sensors; check EEV operation. (Quick guide 31-75036-1, p. 2)
-
The tank temperature sensor reads outside 30-170 F.F2
The tank temperature sensor reads outside 30-170 F. The alarm cannot be silenced with the arrows. (Installation manual 238-52169-00C, p. 28)
For a technician
- Check T2 sensor mounting, wiring and resistance; use service mode to monitor T2; control assembly may have failed. (Quick guide 31-75036-1, p. 2)
-
The compressor was told to run but drew no current.F3
The compressor was told to run but drew no current. (Installation manual 238-52169-00C, p. 28)
For a technician
- Check compressor run capacitor, compressor, overloads, relay and wiring; use service mode to cycle the compressor. (Quick guide 31-75036-1, p. 2)
-
The fan is not working.F4
The fan is not working. (Installation manual 238-52169-00C, p. 28)
For a technician
- Check fan and wiring. (Quick guide 31-75036-1, p. 2)
-
The evaporator inlet temperature sensor reads shorted or open.F5
The evaporator inlet temperature sensor reads shorted or open. (Installation manual 238-52169-00C, p. 28)
For a technician
- Check T3a sensor mounting, wiring and resistance; use service mode to monitor it; control assembly may have failed. (Quick guide 31-75036-1, p. 2)
-
The evaporator outlet temperature sensor reads shorted or open.F6
The evaporator outlet temperature sensor reads shorted or open. (Installation manual 238-52169-00C, p. 28)
For a technician
- Check T3b sensor mounting, wiring and resistance; use service mode to monitor it; control assembly may have failed. (Quick guide 31-75036-1, p. 2)
-
The compressor outlet temperature sensor reads shorted or open.F7
The compressor outlet temperature sensor reads shorted or open. (Installation manual 238-52169-00C, p. 28)
For a technician
- Check T4 sensor mounting, wiring and resistance; use service mode to monitor it; control assembly may have failed. (Quick guide 31-75036-1, p. 2)
-
The room air temperature sensor reads shorted or open.F8
The room air temperature sensor reads shorted or open. (Installation manual 238-52169-00C, p. 29)
For a technician
- Check T5 sensor mounting, wiring and resistance; use service mode to monitor it; control assembly may have failed. (Quick guide 31-75036-1, p. 2)
-
The lower electric element draws no current.F9
The lower electric element draws no current. (Installation manual 238-52169-00C, p. 29)
For a technician
- Check lower heating element and wiring; cycle it in service mode and check current; control may have failed. (Quick guide 31-75036-1, p. 2)
-
The upper electric element draws no current.F10
The upper electric element draws no current. (Installation manual 238-52169-00C, p. 29)
For a technician
- Check upper heating element and wiring; cycle it in service mode and check current. (Quick guide 31-75036-1, p. 2)
-
The tank heated too fast in the first 22 minutes, which means it is not full of water.F11 - Dry tank
The tank heated too fast in the first 22 minutes, which means it is not full of water. (Installation manual 238-52169-00C, p. 29)
What you can check
- Turn power OFF, finish filling the tank (open hot faucets until water flows steadily), then turn power back ON. (Installation manual 238-52169-00C, p. 17)
- If the tank is confirmed full, turn the breaker off for about 10 minutes, then back on; if F11 persists, schedule service. (Quick guide 238-52324-00B, p. 9)
For a technician
- Check T2 sensor mounting, wiring and resistance; control may have failed. (Quick guide 31-75036-1, p. 2)
-
The heater saw under 155 volts one minute after power-up, usually a wiring problem.bAd linE / F12
The heater saw under 155 volts one minute after power-up, usually a wiring problem. (Installation manual 238-52169-00C, p. 29)
For a technician
- Turn power off and correct the wiring; 240 or 208 VAC must be across L1 and L2; remove utility devices that drop voltage to 120 VAC. (Installation manual 238-52169-00C, p. 17)
-
A front-panel button is stuck down.F13 - Stuck key
A front-panel button is stuck down. It clears by itself when the button is freed. (Installation manual 238-52169-00C, p. 29)
What you can check
- Check that all buttons press and release freely. (Quick guide 31-75036-1, p. 2)
For a technician
- If the button does not free, the control assembly has failed. (Quick guide 31-75036-1, p. 2)
-
The air filter is clogged.Dirty Filter (F14)
The air filter is clogged. The filter light comes on and the heater beeps. (Installation manual 238-52169-00C, p. 29)
What you can check
- Leave power on, remove the filter from the top, vacuum or rinse it, let it dry, reinstall, then press and hold the FILTER button to reset. (Quick guide 238-52324-00B, p. 4)
For a technician
- Repeated dirty filter alarms that do not clear after cleaning may mean a fan failure. (Quick guide 31-75036-1, p. 2)
-
The control’s memory failed.F15
The control’s memory failed. (Installation manual 238-52169-00C, p. 29)
For a technician
- Control assembly may have failed. (Quick guide 31-75036-1, p. 2)
-
The anode rod is mostly used up (or its service time has passed).F16* (some models)
The anode rod is mostly used up (or its service time has passed). Anode light on, alarm sounding. (Installation manual 238-52169-00C, p. 29)
For a technician
- Inspect the anode rod: the control has calculated it is mostly consumed or past its replacement timeline. (Installation manual 238-52169-00C, p. 29)
-
The anode-monitoring circuit is miswired or shorted, so the tank may not be protected from corrosion.F17* (some models)
The anode-monitoring circuit is miswired or shorted, so the tank may not be protected from corrosion. (Installation manual 238-52169-00C, p. 29)
What you can check
- Check that the tank is filled completely with water; if F17 persists, contact service. (Quick guide 238-52324-00B, p. 9)
For a technician
- Check anode connection and wiring. (Quick guide 238-52324-00B, p. 9)
-
F3, F9 and F10 all occurred in one heating cycle, so the current sensor wiring is wrong.F18
F3, F9 and F10 all occurred in one heating cycle, so the current sensor wiring is wrong. (Installation manual 238-52169-00C, p. 29)
By model: Listed for RE2H50S/65T/80T and the RE2H50/80 R10B guide (bw-75036); not in the first-generation RE2H50R10 guide (bw-50804).
For a technician
- Check that the red L2 wire passes through the CT201 current transformer on the board; if it does, replace the board. (Quick guide 31-75036-1, p. 2)
-
Incoming voltage is too low.F19
Incoming voltage is too low. (Installation manual 238-52169-00C, p. 29)
By model: Listed for RE2H50S/65T/80T and the RE2H50/80 R10B guide (bw-75036); not in the first-generation RE2H50R10 guide (bw-50804).
For a technician
- Check incoming line voltage. (Quick guide 31-75036-1, p. 2)
-
The condensate drain is clogged, so the heater runs on electric only until it is cleared.F20 - Condensate drain blocked
The condensate drain is clogged, so the heater runs on electric only until it is cleared. (Installation manual 238-52169-00C, p. 29)
By model: Listed for RE2H50S/65T/80T and the RE2H50/80 R10B guide (bw-75036); not in the first-generation RE2H50R10 guide (bw-50804).
What you can check
- Press any button to silence the alarm, then clear the condensate drain: remove drain lines and connections, clear debris, reattach. (Quick guide 238-52324-00B, p. 4)
For a technician
- Check the main drain on the condensate pan and that the level sensor sits on the screw post near the main drain port. (Quick guide 31-75036-1, p. 2)
-
A control software update failed.F21
A control software update failed. (Installation manual 238-52169-00C, p. 29)
By model: Listed for RE2H50S/65T/80T and the RE2H50/80 R10B guide (bw-75036); not in the first-generation RE2H50R10 guide (bw-50804).
For a technician
- Cycle power and try the update again; replace the control board if it persists. (Quick guide 31-75036-1, p. 2)
-
A settings-data update failed.F22
A settings-data update failed. (Installation manual 238-52169-00C, p. 29)
By model: Listed for RE2H50S/65T/80T and the RE2H50/80 R10B guide (bw-75036); not in the first-generation RE2H50R10 guide (bw-50804).
For a technician
- Cycle power and retry; replace the control board if it persists. (Quick guide 31-75036-1, p. 2)
-
An input on the control’s microprocessor failed.F23
An input on the control’s microprocessor failed. (Installation manual 238-52169-00C, p. 29)
By model: Listed for RE2H50S/65T/80T and the RE2H50/80 R10B guide (bw-75036); not in the first-generation RE2H50R10 guide (bw-50804).
For a technician
- The control needs to be replaced. (Quick guide 31-75036-1, p. 2)
-
The T1 tank sensor reads outside 30-170 F.F24
The T1 tank sensor reads outside 30-170 F. (Installation manual 238-52169-00C, p. 29)
By model: Listed only for RE2H50S/65T/80T.
For a technician
- Check T1 sensor mounting, wiring and resistance. (Installation manual 238-52169-00C, p. 29)
Infiniti tankless
Number codes on the GS and GR, letter-and-number codes on the K, L and older HE and ME. The same code can mean different things on K/L and HE/ME.
-
The flame went out 8 times.Er.10 - Flame has been lost 8 (eight) times (hard lock)
The flame went out 8 times. The heater is locked until you press Power. (Installation manual 238-54627-00B, p. 74)
What you can check
- Press the Power button on the control panel to clear the code. (Installation manual 238-54627-00B, p. 74)
- Make sure the cold water and gas supply valves to the heater are open and the water lines are not frozen. (Installation manual 238-54627-00B, p. 77)
For a technician
- Monitor gas pressure while running: 3.5-10.5 in. WC natural gas, 8-14 in. WC LP. (Installation manual 238-54627-00B, p. 74)
- Check gas valve wire and flame detection sensor (more than 2.5 VDC before ignition, less than 2.5 VDC after), ignition transformer; clean the spark igniter with steel wool, gap 0.12-0.16 in.; replace if damaged. (Installation manual 238-54627-00B, p. 74)
-
The burner failed to light 10 times.Er.11 - Ignition has Failed 10 (Ten) Times (hard lock)
The burner failed to light 10 times. Locked until reset. (Installation manual 238-54627-00B, p. 74)
What you can check
- Press the Power button on the control panel to clear the code. (Installation manual 238-54627-00B, p. 74)
- Make sure the cold water and gas supply valves to the heater are open and the water lines are not frozen. (Installation manual 238-54627-00B, p. 77)
For a technician
- Monitor gas pressure while running: 3.5-10.5 in. WC natural gas, 8-14 in. WC LP. (Installation manual 238-54627-00B, p. 74)
- Check gas valve wire and flame detection sensor (more than 2.5 VDC before ignition, less than 2.5 VDC after), ignition transformer; clean the spark igniter with steel wool, gap 0.12-0.16 in.; replace if damaged. (Installation manual 238-54627-00B, p. 74)
-
Water in the heat exchanger or outlet went over 199 F.Er.16 - Water above 199 F (soft lock)
Water in the heat exchanger or outlet went over 199 F. Clears when it cools. (Installation manual 238-54627-00B, p. 74)
What you can check
- Make sure hot water lines and valves are open so enough water flows through the heater. (Installation manual 238-54627-00B, p. 74)
For a technician
- Check DIP switches 6 and 7 are OFF (MAX fire); check DHW and operating temperature sensors (zero resistance = replace). (Installation manual 238-54627-00B, p. 74)
-
The high-limit overheat switch opened.Er.20 - High Limit Overheat Switch open (hard lock)
The high-limit overheat switch opened. (Installation manual 238-54627-00B, p. 74)
What you can check
- Press the Power button on the control panel to clear the code. (Installation manual 238-54627-00B, p. 74)
For a technician
- Inspect connections; check switch continuity at room temperature. (Installation manual 238-54627-00B, p. 74)
-
Condensate is not draining, or the exhaust is blocked.Er.29 - Condensate Trap Blocked (hard lock)
Condensate is not draining, or the exhaust is blocked. (Installation manual 238-54627-00B, p. 74)
What you can check
- Check the condensate line and its end (termination) for blockages; check the exhaust vent for blockage; press Power to clear. (Installation manual 238-54627-00B, p. 74)
For a technician
- Refill/clean the condensate trap if the problem repeats. (Installation manual 238-54627-00B, p. 80)
-
The cold-water inlet sensor reads open or shorted.Er.31 - Inlet Water Sensor Open or Short (soft lock)
The cold-water inlet sensor reads open or shorted. Clears when it reads correctly. (Installation manual 238-54627-00B, p. 74)
For a technician
- Check sensor connections and resistance; replace the sensor if resistance is zero. (Installation manual 238-54627-00B, p. 74)
-
The hot water outlet sensor reads open or shorted.Er.32 - DHW Sensor Open or Short (soft lock)
The hot water outlet sensor reads open or shorted. Clears when it reads correctly. (Installation manual 238-54627-00B, p. 74)
For a technician
- Check sensor connections and resistance; replace the sensor if resistance is zero. (Installation manual 238-54627-00B, p. 74)
-
The heat exchanger temperature sensor reads open or shorted.Er.33 - Operating Temperature Sensor Open or Short (soft lock)
The heat exchanger temperature sensor reads open or shorted. Clears when it reads correctly. (Installation manual 238-54627-00B, p. 74)
For a technician
- Check sensor connections and resistance; replace the sensor if resistance is zero. (Installation manual 238-54627-00B, p. 74)
-
The exhaust temperature sensor reads open or shorted.Er.35 - Exhaust Sensor Open or Short (soft lock)
The exhaust temperature sensor reads open or shorted. (Installation manual 238-54627-00B, p. 74)
What you can check
- Look outside at the exhaust vent and air intake for blockage. (Installation manual 238-54627-00B, p. 74)
For a technician
- Check exhaust sensor connections and resistance; replace if zero. (Installation manual 238-54627-00B, p. 74)
-
The flame sensor still sees flame (or outside light) after the burner shut off.Er.39 - Flame Detected after Exiting a Flame On Condition (soft lock)
The flame sensor still sees flame (or outside light) after the burner shut off. (Installation manual 238-54627-00B, p. 75)
What you can check
- Make sure the heater’s front cover is on and secure; the flame sensor can detect outside light. (Installation manual 238-54627-00B, p. 75)
For a technician
- Check flame detection sensor connections and voltage. (Installation manual 238-54627-00B, p. 75)
-
The heater’s built-in gas leak detection tripped.Er.40 - Gas Leakage Detected (hard lock)
The heater’s built-in gas leak detection tripped. Treat it as a possible gas leak. (Installation manual 238-54627-00B, p. 75)
What you can check
- If you smell gas, STOP: follow the gas-smell instructions and call a qualified service technician or the gas utility. Otherwise check the cover is secure and press Power. (Installation manual 238-54627-00B, p. 75)
For a technician
- Check gas connections for leakage with a soapy solution and fix leaks; check burner assembly. (Installation manual 238-54627-00B, p. 75)
-
The fan is running too fast while firing, often from a vent problem.Er.41 - Fan Speed too High with Flame On (hard lock)
The fan is running too fast while firing, often from a vent problem. (Installation manual 238-54627-00B, p. 75)
What you can check
- Press the Power button on the control panel to clear the code. (Installation manual 238-54627-00B, p. 74)
- Check the vent connections and terminations for blockage. (Installation manual 238-54627-00B, p. 75)
For a technician
- Check burner assembly and fan; replace the fan if RPM is wrong. (Installation manual 238-54627-00B, p. 75)
-
The air pressure switch opened, often from a blocked exhaust.Er.42 - APS (air pressure switch) open (hard lock)
The air pressure switch opened, often from a blocked exhaust. (Installation manual 238-54627-00B, p. 75)
What you can check
- Press the Power button on the control panel to clear the code. (Installation manual 238-54627-00B, p. 74)
- Look outside at the exhaust vent and air intake for blockage. (Installation manual 238-54627-00B, p. 74)
For a technician
- Check APS connections, resistance and hose; replace APS if faulty. (Installation manual 238-54627-00B, p. 75)
-
The burner overheat switch opened.Er.43 - Burner Overheat Switch Open (hard lock)
The burner overheat switch opened. (Installation manual 238-54627-00B, p. 75)
What you can check
- Press the Power button on the control panel to clear the code. (Installation manual 238-54627-00B, p. 74)
For a technician
- Check overheat switch connections and continuity at room temperature; replace if not closed. (Installation manual 238-54627-00B, p. 75)
-
GR only: the built-in recirculation pump may have failed.Er.44 - Possible pump failure (GR only, hard lock)
GR only: the built-in recirculation pump may have failed. (Installation manual 238-54628-00B, p. 76)
By model: GR (built-in pump) only.
What you can check
- Press the Power button to clear the Error Code. (Installation manual 238-54628-00B, p. 76)
For a technician
- Check pump; replace pump if the problem persists. (Installation manual 238-54628-00B, p. 76)
-
The built-in leak detector found water; the heater closed its cold-water inlet valve to limit damage.Er.45 - Water Leak Detection (hard lock)
The built-in leak detector found water; the heater closed its cold-water inlet valve to limit damage. (Installation manual 238-54627-00B, p. 75)
What you can check
- Turn power off, close the valves to isolate the heater, and call a qualified installer or service technician. (Installation manual 238-54627-00B, p. 75)
For a technician
- Find and repair the leak. (Installation manual 238-54627-00B, p. 75)
-
GR only: not enough flow in the recirculation loop.Er.46 - Low recirculation flow (GR only, hard lock)
GR only: not enough flow in the recirculation loop. (Installation manual 238-54628-00B, p. 76)
By model: GR only.
What you can check
- Press the Power button to clear the Error Code (Installation manual 238-54628-00B, p. 76)
For a technician
- Check return and cold water filters, recirculation loop length, pump, and the recirculation setting; replace pump if it persists. (Installation manual 238-54628-00B, p. 76)
-
GR only: hot water temperature is abnormal.Er.60 - Hot water temperature Abnormality (GR only, soft lock)
GR only: hot water temperature is abnormal. (Installation manual 238-54628-00B, p. 77)
By model: GR only.
For a technician
- Check DIP switches 6 and 7, DHW pipe, DHW and operating sensors; clean the inlet and recirculation return filters. (Installation manual 238-54628-00B, p. 77)
- Flush the heat exchanger. (Installation manual 238-54628-00B, p. 77)
-
The fan speed signal is wrong or the fan is not turning.Er.61 - Fan Speed Feedback Signal Abnormal (soft lock)
The fan speed signal is wrong or the fan is not turning. (Installation manual 238-54627-00B, p. 75)
By model: GS manual: 26.5 VAC; GR manual: 120VAC at the fan connection (bw-54628 p. 77).
For a technician
- Check fan connections; check power at the fan (26.5 VAC on GS, 120 VAC on GR); replace blower or control. (Installation manual 238-54627-00B, p. 75)
-
The water supply (flow control) valve has a fault.Er.65 - Supply Water Valve Error (hard lock)
The water supply (flow control) valve has a fault. (Installation manual 238-54627-00B, p. 75)
What you can check
- Press the Power button on the control panel to clear the code. (Installation manual 238-54627-00B, p. 74)
For a technician
- Turn power OFF and ON at the main power switch inside the heater; check wiring; replace supply water valve. (Installation manual 238-54627-00B, p. 75)
-
The internal mixing valve has a fault.Er.66 - Mixing Valve Error (hard lock)
The internal mixing valve has a fault. (Installation manual 238-54627-00B, p. 75)
What you can check
- Press the Power button on the control panel to clear the code. (Installation manual 238-54627-00B, p. 74)
For a technician
- Power OFF/ON at the internal switch; check wiring; replace mixing valve. (Installation manual 238-54627-00B, p. 75)
-
The AGM (air/gas mixing) part at the fan inlet has a fault.Er.67 - AGM Error (hard lock)
The AGM (air/gas mixing) part at the fan inlet has a fault. (Installation manual 238-54627-00B, p. 76)
What you can check
- Press the Power button on the control panel to clear the code. (Installation manual 238-54627-00B, p. 74)
For a technician
- Power OFF/ON at the internal switch; make sure the fan inlet hole is open; check AGM wiring and operation; replace AGM. (Installation manual 238-54627-00B, p. 76)
-
The flame sensor sees flame or light before ignition.Er.72 - Flame Signal Detected before Ignition (soft lock)
The flame sensor sees flame or light before ignition. (Installation manual 238-54627-00B, p. 76)
What you can check
- Make sure the heater cover is secure (outside light can trigger the sensor). (Installation manual 238-54627-00B, p. 76)
For a technician
- Check flame detection sensor connections and voltage. (Installation manual 238-54627-00B, p. 76)
-
The DIP switch settings do not match the heater.Er.73 - DIP Switch is abnormal (soft lock)
The DIP switch settings do not match the heater. (Installation manual 238-54627-00B, p. 76)
For a technician
- Set DIP switches to match the rating plate (see DIP switch section). (Installation manual 238-54627-00B, p. 76)
-
The main control and the display panel are not talking.Er.76 - Poor Communication (soft lock)
The main control and the display panel are not talking. (Installation manual 238-54627-00B, p. 76)
For a technician
- Check connections from main control to display; replace display if it persists. (Installation manual 238-54627-00B, p. 76)
-
Cascaded (linked) heaters only: units lost communication.Er.78 - Cascade Communication Error (soft lock)
Cascaded (linked) heaters only: units lost communication. (Installation manual 238-54627-00B, p. 76)
What you can check
- Turn power OFF and ON at the display panel; make sure all cascaded heaters are powered on. (Installation manual 238-54627-00B, p. 76)
For a technician
- Check Installer Mode parameter 13:cn addresses and cascade cables. (Installation manual 238-54627-00B, p. 76)
-
Exhaust temperature is too high.Er.94 - Exhaust over 149 F (195 F commercial) (hard lock)
Exhaust temperature is too high. (Installation manual 238-54627-00B, p. 76)
What you can check
- Look outside at the exhaust vent and air intake for blockage. (Installation manual 238-54627-00B, p. 74)
For a technician
- Check DIP switches 6 and 7 OFF; check exhaust sensor connections and resistance. (Installation manual 238-54627-00B, p. 76)
-
A water temperature sensor is disconnected or damaged.A0
A water temperature sensor is disconnected or damaged. (Installation manual 6 720 817 984, p. 64)
For a technician
- Check water temperature sensor wire connections; replace the sensor and/or wiring if the problem persists (resistance charts fig. 63-64). (Installation manual 6 720 817 984, p. 64)
-
The air inside the cabinet is over 158 F; the heater cuts its power to protect itself.A1
The air inside the cabinet is over 158 F; the heater cuts its power to protect itself. (Installation manual 6 720 817 984, p. 64)
What you can check
- Check whether the air around the heater is above 140 F. (Installation manual 6 720 817 984, p. 64)
For a technician
- Check for flue leakages inside the appliance. (Installation manual 6 720 817 984, p. 64)
-
The optional tank sensor/aquastat (tank-loading setups) is disconnected or misplaced.A2
The optional tank sensor/aquastat (tank-loading setups) is disconnected or misplaced. (Installation manual 6 720 817 984, p. 64)
For a technician
- Check the sensor and connections, its position in the tank well, and the recirculation settings; turn menu SA-A1 OFF if tank loading is not used. (Service manual 238-53328-00B, p. 61)
-
The flue gas temperature sensor is disconnected or damaged.A3
The flue gas temperature sensor is disconnected or damaged. (Installation manual 6 720 817 984, p. 64)
For a technician
- Check flue gas temperature sensor wire connections; replace the sensor and/or wiring if the problem persists (resistance charts fig. 63-64). (Installation manual 6 720 817 984, p. 64)
-
The cabinet air temperature sensor is disconnected or damaged.A4
The cabinet air temperature sensor is disconnected or damaged. (Installation manual 6 720 817 984, p. 64)
For a technician
- Check cabinet air temperature sensor wire connections; replace the sensor and/or wiring if the problem persists (resistance charts fig. 63-64). (Installation manual 6 720 817 984, p. 64)
-
The condensing heat exchanger flue sensor is disconnected or damaged.A5
The condensing heat exchanger flue sensor is disconnected or damaged. (Installation manual 6 720 817 984, p. 64)
For a technician
- Check condensing unit flue temperature sensor wire connections; replace the sensor and/or wiring if the problem persists (resistance charts fig. 63-64). (Installation manual 6 720 817 984, p. 64)
-
The cold-water inlet sensor is disconnected or damaged.A6
The cold-water inlet sensor is disconnected or damaged. (Installation manual 6 720 817 984, p. 64)
For a technician
- Check inlet water temperature sensor wire connections; replace the sensor and/or wiring if the problem persists (resistance charts fig. 63-64). (Installation manual 6 720 817 984, p. 64)
-
The heat exchanger water sensor is disconnected or damaged.A7
The heat exchanger water sensor is disconnected or damaged. (Installation manual 6 720 817 984, p. 64)
For a technician
- Check heat exchanger water temperature sensor wire connections; replace the sensor and/or wiring if the problem persists (resistance charts fig. 63-64). (Installation manual 6 720 817 984, p. 64)
-
The hot water outlet sensor is disconnected or damaged.A8
The hot water outlet sensor is disconnected or damaged. (Installation manual 6 720 817 984, p. 64)
For a technician
- Check outlet water temperature sensor wire connections; replace the sensor and/or wiring if the problem persists (resistance charts fig. 63-64). (Installation manual 6 720 817 984, p. 64)
-
The heater cannot reach full output, often from low gas pressure.A9
The heater cannot reach full output, often from low gas pressure. (Installation manual 6 720 817 984, p. 64)
What you can check
- Reset by closing and opening all water taps (footnote 3). (Installation manual 6 720 817 984, p. 68)
For a technician
- Check gas inlet pressure (below 3.5 in. W.C. NG or 8 in. W.C. LP is too low); check water temperature and flow sensor connections. (Service manual 238-53328-00B, p. 61)
-
Flue gas is running hot (often scale in the heat exchanger), so the heater limits its power.AA
Flue gas is running hot (often scale in the heat exchanger), so the heater limits its power. (Installation manual 6 720 817 984, p. 65)
For a technician
- Check flue gas and water inlet temperature sensors. (Installation manual 6 720 817 984, p. 65)
- Descale appliance (section 7.3). (Installation manual 6 720 817 984, p. 65)
-
The heater is cutting its output (high altitude, long vent, blocked air or dirty filter).AD
The heater is cutting its output (high altitude, long vent, blocked air or dirty filter). It keeps running. (Installation manual 6 720 817 984, p. 65)
What you can check
- Reset the error: press and hold the on/off button for 3 seconds. (Installation manual 6 720 817 984, p. 64)
- Check the air intake and exhaust pipes and their outside terminals for obstructions, then reset the error. (Installation manual 6 720 817 984, p. 65)
For a technician
- Check flue length against specification; check/replace the air filter (inside, on the fan); perform gas and air tuning. (Installation manual 6 720 817 984, p. 65)
-
Missed ignitions made the heater recalibrate its fan.BB
Missed ignitions made the heater recalibrate its fan. (Installation manual 6 720 817 984, p. 65)
For a technician
- Check gas inlet pressure; perform gas and air tuning (section 8.11). (Installation manual 6 720 817 984, p. 65)
-
Repeated fan calibrations with the same result.BC
Repeated fan calibrations with the same result. (Installation manual 6 720 817 984, p. 65)
For a technician
- Check gas inlet pressure; perform gas and air tuning. (Installation manual 6 720 817 984, p. 65)
-
At start-up the heater found the vent blocked or not enough combustion air, and shut down for safety.C1, C2
At start-up the heater found the vent blocked or not enough combustion air, and shut down for safety. (Installation manual 6 720 817 984, p. 65)
What you can check
- Reset the error: press and hold the on/off button for 3 seconds. (Installation manual 6 720 817 984, p. 64)
- Check the air intake and exhaust pipes and their outside terminals for obstructions, then reset the error. (Installation manual 6 720 817 984, p. 65)
- Reset also by closing and opening all hot water faucets, limited to 3 times per hour. (Installation manual 6 720 817 984, p. 68)
For a technician
- Check the air filter (on the fan), flue length vs. specification, gas and air tuning; if it persists the burner surface may be clogged - contact Bradford White support. (Installation manual 6 720 817 984, p. 59)
-
Recirculation flow is not detected.C3
Recirculation flow is not detected. (Installation manual 6 720 817 984, p. 65)
By model: Recirculation setups (L Series built-in pump, or K with external pump).
What you can check
- Check the recirculation circuit for any blockage (closed valves). (Installation manual 6 720 817 984, p. 65)
For a technician
- Check pump and connections. (Installation manual 6 720 817 984, p. 65)
-
The internal bypass water valve is disconnected or damaged; the heater can keep running without it.C5
The internal bypass water valve is disconnected or damaged; the heater can keep running without it. (Installation manual 6 720 817 984, p. 65)
For a technician
- Check bypass valve wiring; replace the valve and run bypass valve calibration (section 6.6). (Installation manual 6 720 817 984, p. 65)
-
The fan is disconnected or not working.C7
The fan is disconnected or not working. (Installation manual 6 720 817 984, p. 65)
What you can check
- Reset the error: press and hold the on/off button for 3 seconds. (Installation manual 6 720 817 984, p. 64)
For a technician
- Check fan wire connections; replace the fan and/or wiring. (Installation manual 6 720 817 984, p. 65)
-
The main water valve is disconnected or damaged.C8
The main water valve is disconnected or damaged. (Installation manual 6 720 817 984, p. 66)
For a technician
- Check valve wiring; replace and calibrate (section 6.6). (Installation manual 6 720 817 984, p. 66)
-
The barometric pressure sensor on the control has failed.C9
The barometric pressure sensor on the control has failed. (Installation manual 6 720 817 984, p. 66)
What you can check
- Reset the error: press and hold the on/off button for 3 seconds. (Installation manual 6 720 817 984, p. 64)
For a technician
- Replace electronic control unit (ECU). (Installation manual 6 720 817 984, p. 66)
-
Water flow is above 9.2 gpm (or there is air in the water circuit).CA
Water flow is above 9.2 gpm (or there is air in the water circuit). (Installation manual 6 720 817 984, p. 66)
For a technician
- Purge the water circuit of air; install a flow restrictor; check water pressure does not exceed 150 psi. (Installation manual 6 720 817 984, p. 66)
-
While running, exhaust pressure got too high (blocked exhaust), and the heater shut down for safety.CE
While running, exhaust pressure got too high (blocked exhaust), and the heater shut down for safety. (Installation manual 6 720 817 984, p. 66)
What you can check
- Reset the error: press and hold the on/off button for 3 seconds. (Installation manual 6 720 817 984, p. 64)
- Check the exhaust pipes and terminals for obstructions, then reset. Reset is limited to 3 times per hour. (Installation manual 6 720 817 984, p. 66)
For a technician
- Check air filter, flue length, gas and air tuning. (Installation manual 6 720 817 984, p. 66)
-
While running, the heater detected a blocked vent or air intake and shut down for safety.CF
While running, the heater detected a blocked vent or air intake and shut down for safety. (Installation manual 6 720 817 984, p. 66)
What you can check
- Reset the error: press and hold the on/off button for 3 seconds. (Installation manual 6 720 817 984, p. 64)
- Check the air intake and exhaust pipes and their outside terminals for obstructions, then reset the error. (Installation manual 6 720 817 984, p. 65)
For a technician
- Check the air filter, flue length vs. specification, gas and air tuning; contact Bradford White support for dusty installations. (Installation manual 6 720 817 984, p. 66)
-
The control board has an internal error.E0
The control board has an internal error. (Installation manual 6 720 817 984, p. 66)
What you can check
- Reset the error: press and hold the on/off button for 3 seconds. (Installation manual 6 720 817 984, p. 64)
For a technician
- Replace electronic control unit if it persists. (Installation manual 6 720 817 984, p. 66)
-
Outlet water went over 194 F; the burner shut off to prevent scalding and restarts after cooling.E1
Outlet water went over 194 F; the burner shut off to prevent scalding and restarts after cooling. (Installation manual 6 720 817 984, p. 66)
What you can check
- If it repeats, reduce the setpoint temperature. (Installation manual 6 720 817 984, p. 66)
For a technician
- Purge the water circuit to remove air. (Installation manual 6 720 817 984, p. 66)
-
Exhaust got too hot (often scale buildup); the burner shut off.E3
Exhaust got too hot (often scale buildup); the burner shut off. (Installation manual 6 720 817 984, p. 67)
What you can check
- Reset the error: press and hold the on/off button for 3 seconds. (Installation manual 6 720 817 984, p. 64)
For a technician
- Descale appliance (section 7.3). (Installation manual 6 720 817 984, p. 67)
- Check flue sensor [15] resistance; replace if out of spec. (Installation manual 6 720 817 984, p. 67)
-
The cabinet air got too hot; the burner shut off.E4
The cabinet air got too hot; the burner shut off. (Installation manual 6 720 817 984, p. 67)
What you can check
- Reset the error: press and hold the on/off button for 3 seconds. (Installation manual 6 720 817 984, p. 64)
For a technician
- Check for flue gas leakage inside the cabinet or concentric vent; check sensor [18]. (Installation manual 6 720 817 984, p. 67)
-
The condensing heat exchanger flue got very hot (usually scale).E5
The condensing heat exchanger flue got very hot (usually scale). (Installation manual 6 720 817 984, p. 67)
What you can check
- Reset the error: press and hold the on/off button for 3 seconds. (Installation manual 6 720 817 984, p. 64)
For a technician
- Descale appliance (section 7.3). (Installation manual 6 720 817 984, p. 67)
- Check sensor [16] resistance. (Installation manual 6 720 817 984, p. 67)
-
Internal control error.E7
Internal control error. (Installation manual 6 720 817 984, p. 67)
What you can check
- Reset the error: press and hold the on/off button for 3 seconds. (Installation manual 6 720 817 984, p. 64)
For a technician
- Replace electronic control unit if it persists. (Installation manual 6 720 817 984, p. 67)
-
The control failed its flame-sensing self-test.E8
The control failed its flame-sensing self-test. (Installation manual 6 720 817 984, p. 67)
For a technician
- Replace electronic control unit. (Installation manual 6 720 817 984, p. 67)
-
The thermal fuse (over 237 F) has opened.E9
The thermal fuse (over 237 F) has opened. (Installation manual 6 720 817 984, p. 67)
By model: Service manual: 'Thermofuse open. Temperature above 237 °F.' (bw-53328 p. 62).
For a technician
- Replace thermal fuse. (Installation manual 6 720 817 984, p. 67)
-
The burner did not light (service manual: flame not detected 9 times in a row).EA
The burner did not light (service manual: flame not detected 9 times in a row). (Installation manual 6 720 817 984, p. 67)
By model: bw-53328 p. 62: 'Flame not detected. Ionization loss 9 consecutive times.'
What you can check
- Reset by closing and opening all hot water faucets, limited to 3 times per hour. (Installation manual 6 720 817 984, p. 68)
For a technician
- Check gas inlet pressure; perform gas and air tuning; check ignition and ionization electrodes. (Installation manual 6 720 817 984, p. 67)
-
Internal control error.EB
Internal control error. (Installation manual 6 720 817 984, p. 67)
What you can check
- Reset the error: press and hold the on/off button for 3 seconds. (Installation manual 6 720 817 984, p. 64)
For a technician
- Replace electronic control unit if it persists. (Installation manual 6 720 817 984, p. 67)
-
The flame kept going out while running (service manual: partial ionization loss 5 times).EC
The flame kept going out while running (service manual: partial ionization loss 5 times). (Installation manual 6 720 817 984, p. 67)
What you can check
- Reset by closing and opening hot water faucets (limited to 3 times per hour). (Installation manual 6 720 817 984, p. 68)
For a technician
- Check gas inlet pressure; perform gas and air tuning. (Installation manual 6 720 817 984, p. 67)
-
The gas valve’s modulating coil is disconnected.EE
The gas valve’s modulating coil is disconnected. (Installation manual 6 720 817 984, p. 67)
For a technician
- Check gas valve wiring; replace gas valve/wiring/ECU and perform gas and air tuning. (Installation manual 6 720 817 984, p. 67)
-
The heater is set for one gas type but is getting the other.EF
The heater is set for one gas type but is getting the other. (Installation manual 6 720 817 984, p. 67)
For a technician
- Check gas type (section 6.7). (Installation manual 6 720 817 984, p. 67)
-
Internal control error.F2, F3, F7, F8
Internal control error. (Installation manual 6 720 817 984, p. 68)
By model: Service manual lists F7 as 'A flame is detected before gas valve open.' (bw-53328 p. 63); the 2023 I&O groups F7 with internal errors.
What you can check
- Reset the error: press and hold the on/off button for 3 seconds. (Installation manual 6 720 817 984, p. 64)
For a technician
- Reconfigure the appliance (region, power, type, gas type) and run combustion adjustment if needed; replace electronic control unit. (Installation manual 6 720 817 984, p. 68)
-
The control’s gas valve driver has a fault.F9
The control’s gas valve driver has a fault. (Installation manual 6 720 817 984, p. 68)
For a technician
- Check gas valve wiring; replace wiring and/or ECU. (Installation manual 6 720 817 984, p. 68)
-
A gas valve is not sealing (gas leaking through the valve).FA
A gas valve is not sealing (gas leaking through the valve). Safety lockout. (Installation manual 6 720 817 984, p. 68)
For a technician
- Replace the gas valve and/or gas manifold, then gas and air tuning. (Installation manual 6 720 817 984, p. 68)
-
A button was held more than 30 seconds.FC
A button was held more than 30 seconds. (Installation manual 6 720 817 984, p. 68)
By model: Indoor K/L only (not in the outdoor K table).
What you can check
- Release the button. (Installation manual 6 720 817 984, p. 68)
-
The display cannot talk to the control board.Display shows '--'
The display cannot talk to the control board. (Installation manual 6 720 817 984, p. 68)
What you can check
- Unplug the heater for at least 10 seconds and plug it back in. (Installation manual 6 720 817 984, p. 68)
For a technician
- Replace display, wiring or ECU. (Installation manual 6 720 817 984, p. 68)
-
The flue gas limiter tripped: over 230 F inside the cabinet (possible flue gas leak).A2 (RTG-199HE/ME)
The flue gas limiter tripped: over 230 F inside the cabinet (possible flue gas leak). (Installation manual 6 720 811 617, p. 44)
By model: Different meaning from K/L A2 (external tank sensor).
For a technician
- Check flue gas limiter continuity, heat exchanger seals for flue leakage, and connectors. (Installation manual 6 720 811 617, p. 44)
-
A wire harness is defective.A3 (RTG-199HE/ME)
A wire harness is defective. (Installation manual 6 720 811 617, p. 44)
For a technician
- Check wire harness resistance (115-120 ohm) and diagnostic menu 1P. (Installation manual 6 720 811 617, p. 44)
-
The backflow (exhaust) temperature sensor is disconnected or shorted.A4 (RTG-199HE/ME)
The backflow (exhaust) temperature sensor is disconnected or shorted. (Installation manual 6 720 811 617, p. 44)
By model: K/L A4 means cabinet air sensor instead.
For a technician
- Check backflow sensor connection; replace exhaust temperature sensor. (Installation manual 6 720 811 617, p. 44)
-
Outlet sensor reads below 36 F or above 210 F (can trip from freezing).A7 (RTG-199HE/ME)
Outlet sensor reads below 36 F or above 210 F (can trip from freezing). (Installation manual 6 720 811 617, p. 44)
What you can check
- Protect the heater from freezing; freezing damage is not covered. (Installation manual 6 720 811 617, p. 44)
For a technician
- Check outlet sensor wiring; descale if water is hard; check sensor. (Installation manual 6 720 811 617, p. 44)
-
Outlet temperature sensor defect.A8 (RTG-199HE)
Outlet temperature sensor defect. (Installation manual 6 720 811 617, p. 44)
By model: Not in the RTG-199ME table.
For a technician
- Check wire connection at outlet sensor; descale if needed; check sensor. (Installation manual 6 720 811 617, p. 44)
-
Status: the heater is not reaching the set outlet temperature (often low gas pressure).A9 flashing (RTG-199HE/ME)
Status: the heater is not reaching the set outlet temperature (often low gas pressure). (Installation manual 6 720 811 617, p. 44)
For a technician
- Check gas pressure, 120 VAC grounded supply, outlet sensor wiring. (Installation manual 6 720 811 617, p. 44)
-
Bypass valve solenoid problem.C5 (RTG-199HE)
Bypass valve solenoid problem. (Installation manual 6 720 811 617, p. 44)
By model: Not in the RTG-199ME table.
For a technician
- Check wire connection at the bypass valve. (Installation manual 6 720 811 617, p. 44)
-
The fan is turning too slowly (long/blocked vent, low voltage, low gas).C6 (RTG-199HE/ME)
The fan is turning too slowly (long/blocked vent, low voltage, low gas). (Installation manual 6 720 811 617, p. 45)
What you can check
- Look outside for a blocked vent or intake termination. (Installation manual 6 720 811 617, p. 45)
For a technician
- Check fan wiring, 120 VAC grounded supply, venting (length, elbows, blockage), termination clearances, gas pressure. (Installation manual 6 720 811 617, p. 45)
-
No speed signal from the fan.C7 (RTG-199HE/ME)
No speed signal from the fan. (Installation manual 6 720 811 617, p. 45)
For a technician
- Check fan wiring and connectors; check 120 VAC supply. (Installation manual 6 720 811 617, p. 45)
-
Status: water flow over 10 gpm.CA flashing (RTG-199HE/ME)
Status: water flow over 10 gpm. (Installation manual 6 720 811 617, p. 45)
For a technician
- Check water valve wiring; keep water pressure under 150 psi and flow under 10 gpm. (Installation manual 6 720 811 617, p. 45)
-
Outlet water over 185 F.E1 (RTG-199HE/ME)
Outlet water over 185 F. (Installation manual 6 720 811 617, p. 45)
For a technician
- Check outlet sensor wiring; descale if water is hard. (Installation manual 6 720 811 617, p. 45)
-
Inlet sensor fault; may trip below 36 F (freezing).E2 (RTG-199HE/ME)
Inlet sensor fault; may trip below 36 F (freezing). (Installation manual 6 720 811 617, p. 45)
For a technician
- Check inlet sensor wiring and sensor. (Installation manual 6 720 811 617, p. 45)
-
Exhaust over 194 F; burner locks off (condensing model).E3 (RTG-199HE)
Exhaust over 194 F; burner locks off (condensing model). (Installation manual 6 720 811 617, p. 45)
By model: HE (condensing) only. K/L E3 is a similar flue over-temperature but with different limits.
For a technician
- Clean the heat exchangers, reduce maximum power or water temperature. (Installation manual 6 720 811 617, p. 45)
-
Exhaust backflow over 309 F; burner locks (non-volatile).E4 (RTG-199HE/ME)
Exhaust backflow over 309 F; burner locks (non-volatile). (Installation manual 6 720 811 617, p. 45)
For a technician
- Check vent pipes, secondary fan connections (HE), vent length/elbows. (Installation manual 6 720 811 617, p. 45)
-
The overheat sensor (ECO) is open; resets when below 220 F.E9 (RTG-199HE/ME)
The overheat sensor (ECO) is open; resets when below 220 F. (Installation manual 6 720 811 617, p. 45)
For a technician
- Check overheat sensor wiring, venting, descaling; test sensor continuity. (Installation manual 6 720 811 617, p. 45)
-
The burner did not light.EA (RTG-199HE/ME)
The burner did not light. (Installation manual 6 720 811 617, p. 46)
What you can check
- Verify that all manual gas shut off valves are open; reset and open a hot tap several times to purge air. (Installation manual 6 720 811 617, p. 46)
For a technician
- Have a licensed gas technician purge air from the gas line; check ignition wiring, gas pressure, venting, minimum fan speed, flame and CO2. (Installation manual 6 720 811 617, p. 46)
-
The flame signal was lost while running.EC (RTG-199HE/ME)
The flame signal was lost while running. (Installation manual 6 720 811 617, p. 46)
For a technician
- Check gas type, ignition wiring, venting, gas pressure, CO2 and minimum fan speed. (Installation manual 6 720 811 617, p. 46)
-
Internal control or memory errors.F1, F2, F3, F4, F5, F6, E7, F0, E5, E6 (RTG-199HE)
Internal control or memory errors. (Installation manual 6 720 811 617, p. 46)
By model: HE table only. K/L uses E5/E7/F2/F3 for different things.
For a technician
- Replace ECU if the errors repeat. (Installation manual 6 720 811 617, p. 46)
-
The fan does not stop when it should.F8 (RTG-199HE)
The fan does not stop when it should. (Installation manual 6 720 811 617, p. 46)
For a technician
- Check fan harness and rotation in standby; replace ECU. (Installation manual 6 720 811 617, p. 46)
-
Internal control failure.E0 (RTG-199ME)
Internal control failure. (Installation manual 6 720 811 615, p. 46)
By model: ME table only.
What you can check
- Turn the heater off and back on, then use the reset button. (Installation manual 6 720 811 615, p. 46)
For a technician
- Check control board and chassis ground connections; call manufacturer. (Installation manual 6 720 811 615, p. 46)
-
Flame sensing error while idle.F7 (RTG-199ME)
Flame sensing error while idle. (Installation manual 6 720 811 615, p. 46)
By model: ME table only.
For a technician
- Check the flame ionization rod connection; rod or control may be damaged. (Installation manual 6 720 811 615, p. 46)
-
The gas valve circuit is not closing properly.FA (RTG-199ME)
The gas valve circuit is not closing properly. (Installation manual 6 720 811 615, p. 46)
By model: ME table only.
For a technician
- Check gas valve wiring and 24 VDC at the valve; gas valve may be defective. (Installation manual 6 720 811 615, p. 46)
No Bradford White code matches that. Check the number on the display again, or look at the other brands.
Read this first
Where Bradford White’s own documents disagree
In a few places, two Bradford White documents say different things about the same code. Here’s what each one says, with the page, so you can check yours.
- 6 blinks on Ultra Low NOx (URG) tanks. The 2024 owner’s manual says 6 blinks is a water leak found by the leak accessory module, and it leaves out 10 blinks. The URG service manual and the 2019-and-later quick service guides say 6 blinks is the chamber door temperature sensor, and 10 blinks is not enough air. (Owner’s manual 238-53393-00G, p. 23; Service manual 238-51546-00C, p. 9; Quick service guide 238-55594-00A, p. 1; Quick service guide 238-55595-00A, p. 1)
- 6 blinks on the URG2DV (Ultra Low NOx direct vent). The 2018 service manual says it’s the leak module. The 2019-and-later Ultra Low NOx quick service guides, which cover direct vent models too, say it’s the chamber door sensor. (Service manual 238-51635-00B, pp. 7-8; Quick service guide 238-55594-00A, p. 1; Quick service guide 238-55595-00A, p. 1)
- The temperature sensor on power vent and damper tanks. The sequence-of-operation text in the service manuals says an open temperature sensor flashes 8 then 3. Every troubleshooting chart and the 2019-and-later quick service guides list it as 8 then 2. (Service manual 238-51540-00E; Quick service guide 238-55597-00A, p. 1; Quick service guide 238-55599-00A, p. 1)
- Clearing a high-temperature (4 blinks) lockout on a power vent tank. The same service manual gives two ways: turn the knob to its minimum for 6 seconds, or turn it to LOW and wait 5 minutes. (Service manual 238-51540-00E, pp. 13, 27)
Clearing a code
How to reset a Bradford White, and when to stop
To clear a code
- After a 4-flash over-temperature (ECO) lockout on standing-pilot ICON controls: turn the gas control knob to OFF, wait at least 5 minutes, then relight using the lighting label. (Service manual 238-51542-00E, p. 25)
- Same 4-flash reset (knob OFF, wait a minimum of 5 minutes, relight) for the Honeywell control on pre-2015 Defender models and Ultra Low NOx direct vent models. (Service manual 238-44943-00D, p. 21)
- Owner’s manual: for 5, 7 or 8 flashes, turn the set point knob to OFF, then to PILOT, and light the pilot; the gas valve is replaced if the code persists. (Owner’s manual 238-51012-00T, p. 23)
- Solid LED after turning the knob OFF: wait until the LED goes out before relighting. (Service manual 238-51542-00E, p. 9)
- Pre-2015 ECO-Defender: for 4 flashes rotate the knob to OFF, then follow the lighting instructions; for 7 flashes turn the knob OFF and then follow the lighting instructions. (Service manual 47132A, p. 14)
- Electronic-ignition tanks, 4-flash ECO lockout: rotate the temperature knob to the minimum setting for at least 6 seconds, then back to the desired setting. (Service procedure page 27 of the same manual instead says turn to LOW and wait 5 minutes before relighting.) (Service manual 238-51540-00E, p. 13)
- Flammable vapor sensor / simulated resistive load lockout lasts indefinitely; cycle power to restart. Soft lockouts retry after 5 minutes; hardware errors self-clear after the fault is gone 15 seconds. (Service manual 238-51540-00E, p. 10)
- Pre-2015 power vent: reset a 7-flash flammable vapor sensor fault by cycling power to the appliance or cycling the ON/OFF switch, only after verifying no gasoline vapors are present. (Service manual 238-46238A-00A, p. 14)
- 8-3 and 8-4 gas control faults: interrupt the power supply (owner’s manual: reset the control on/off switch); replace the control if the code returns. (Owner’s manual 238-54331-00B, p. 33)
- ICON E electric: for 5 amber flashes move the setpoint knob back and forth several times and cycle power; for 6 amber flashes move the knob and return it (normal operation for 72 hours). (Service manual 238-55036-00A, p. 9)
- AeroTherm: press either arrow button to stop the beeping (not for F2, F11, F17 or bAd linE); for F11 fill the tank, press ENTER, then cycle power. (Quick guide 238-52324-00B, p. 9)
- AeroTherm service mode: hold UP arrow + Enter 5 seconds to enter; in View Faults and Counters hold Enter 5 seconds to clear all fault codes and counters. (Quick guide 31-75036-1, p. 1)
- Infiniti GS/GR: press the Power button to clear a hard-lock code; soft-lock codes clear themselves when the condition goes away. (Installation manual 238-54627-00B, p. 74)
- Infiniti K/L: press and hold the on/off button for 3 seconds. Codes marked 4) (C1, C2, CE, CF, E3, EA, EC) reset by closing and opening all hot water faucets, limited to 3 times per hour. (Installation manual 6 720 817 984, p. 68)
- Infiniti RTG-199HE/ME: press the reset button to remove the error code. (Installation manual 6 720 811 617, p. 44)
Bradford White’s safety notes
- WHAT TO DO IF YOU SMELL GAS: Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Immediately call your gas supplier from a neighbor’s phone. If you cannot reach your gas supplier, call the fire department. (Service manual 238-51542-00E, p. 3)
- Lighting label (owner): wait five minutes to clear out any gas, then smell for gas including near the floor; if you smell gas, STOP. If the pilot will not stay lit after several tries, turn the gas control knob to OFF and call your technician or gas supplier. (Owner’s manual 238-51012-00T, p. 17)
- Do not open the inner door and attempt to light the pilot by hand. Use only your hand to turn the knob; never use tools; if the knob will not turn, call a qualified service technician. (Owner’s manual 238-51012-00T, p. 17)
- Do not use this appliance if any part has been under water; call a qualified service technician to replace any part of the control system that has been under water. (Owner’s manual 238-51012-00T, p. 17)
- Should overheating occur or the gas supply fail to shut off, turn off the manual gas control valve to the appliance and call a qualified service technician. (Owner’s manual 238-51012-00T, p. 20)
- Replace water heater if involved in flammable vapors incident. Do not operate the water heater with jumpered, altered or absent controls. (Owner’s manual 238-51012-00T, p. 21)
- For your safety, do not attempt repair of combination gas control, burners or gas piping. Refer repairs to a qualified service technician. (Owner’s manual 238-51012-00T, p. 22)
- With the inner door removed the Bradford White Defender Safety System will be deactivated; flammable vapors could then cause a fire or explosion. (Service manual 238-51542-00E, p. 35)
- 7 flashes on pre-2015 power vent: WARNING: EXPLOSION HAZARD. Indicates gasoline vapors were detected at potentially explosive levels. Verify no gasoline vapors are still present before resetting. (Service manual 238-46238A-00A, p. 14)
- Resettable thermal switch: the overheating condition must be determined before putting the heater back in service; a flammable vapor incident means replace the water heater. (Service manual 238-51542-00E, p. 37)
- Infiniti GS/GR code 40 (gas leakage detected): If you smell gas, STOP! Follow the gas-smell instructions and call a qualified service technician or the fuel gas utility. (Installation manual 238-54627-00B, p. 75)
- Infiniti GS/GR: if flue gas is continuously escaping from the condensate drain tubing, it is a serious problem; call a qualified service technician. (Installation manual 238-54627-00B, p. 80)
- Infiniti K/L: automatic blockage resets (C1, C2, CE, CF, E3, EA, EC) are limited to 3 times per hour. Maintenance must be done by a trained or qualified contractor. (Installation manual 6 720 817 984, p. 68)
- AeroTherm: For your safety, DO NOT attempt repair of electrical wiring, controls, heating elements or other safety devices. Refer repairs to qualified service personnel. (Quick guide 238-52324-00B, p. 9)
- AeroTherm: never replace a part based solely on a fault code; the control can generate a false fault. (Installation manual 238-52169-00C, p. 28)
- Hydrogen gas can build up in a heater not used for two weeks or more; run a hot faucet for several minutes before using electrical appliances, with no smoking or open flame nearby. (Service manual 238-51542-00E, p. 3)
Heater getting old, or the same code keeps coming back? Repair or replace? Three taps and Dan’s answer → Or see what a water heater repair usually involves.
Which one do you have?
The Bradford White heaters these codes cover
- ICON 1.0 standing-pilot control (through serial code TA, Jan 2019)RG1 / RG2 / LG2 atmospheric (RG130T ... RG2100H, LG255H, LG275H), MI, M4, M1XR, M2XR, M2C pre-2015 Defender models (gas control labeled 'Honeywell'), RG2DV40S, RG2DV50S, RG2DV50H, LG2DV50H50 (direct vent), URG2DV40S, URG2DV50S, URG2DV50H, ULG2DV50H50 (Ultra Low NOx direct vent, Honeywell WV8840), UDS140S, UDS150S, UDH1504T, UDH165T, UDH175S (archived ULN direct vent) · Green LED on the gas control flashes a count, pauses about 3 seconds, then repeats. Count the flashes between pauses. Knob has OFF / PILOT / temperature settings; powered by the pilot thermopile (no plug).
- ICON 2.0 standing-pilot control (colored light, after Jan 2019)RG1 / RG2 / LG2 atmospheric, RG2DV / LG2DV direct vent, URG2DV / ULG2DV Ultra Low NOx direct vent · Colored LED on the gas control flashes a count, pauses about 3 seconds, then repeats. Note the color as well as the count.
- ICON standing-pilot control, third supplierRG1 / RG2 / LG2 atmospheric, RG2DV / LG2DV direct vent · Green LED on the gas control flashes a count, pauses about 3 seconds, then repeats. Count the flashes between pauses.
- Eco-Defender Ultra Low NOx tank, ICON 1.0URG130T, URG140T, URG150T, URG230T, URG240S, URG240T, URG250L, URG250H, URG250T, URG250S · Green LED on the gas control flashes a count, pauses about 3 seconds, then repeats. Count the flashes between pauses.
- Eco-Defender Ultra Low NOx tank, ICON 2.0URG1 / URG2 atmospheric (same models as uln-atm-v1, newer control) · Colored LED (green/yellow/red) flashes a count, pauses about 3 seconds, then repeats.
- Eco-Defender Ultra Low NOx tank, before 2015U130T, U140T, U1403S, U1503, U150L, U1504S, U430T, U440T, U4403S, U4503, U1XR403S · Red LED on the gas control flashes a count, pauses about 3 seconds, then repeats.
- Power vent and power direct vent (2013 and later)RG1PV40S, RG1PV50S, RG1PV55H, RG2PV40S/T, RG2PV50S/T/H, RG2PV60T, RG2PV75H, LG1PV55H, LG2PV50H, LG2PV75H, RG2PDV40S, RG2PDV50S, RG2PDV50H, RG2PDV75H, LG2PDV50H60, LG2PDV75H80, URG1PV40S, URG1PV50S, URG2PV40T, URG2PV50T, URG2PV50H, ULG2PV50H · Green LED on the gas control. Single counts (2-5, 7) or two-part counts (6-1 = six flashes, then one flash, then a 3-second pause). Plug-in 120 V unit with an ON/OFF switch on the gas control.
- eF Series condensing power ventRC2PV50H, LC2PV50H76, RC2PDV50H, LC2PDV50H76 · Same LED scheme as ei-pv-wv4462.
- Power vent and powered direct vent, before 2015M1TW40S, M1TW50S, M1TW60T, M2TW50T, M2TW65T, M4TW40T, M4TW50T, M4TW60T, TW450S65F, TW465S65F, PDX140S, PDX150S, PDX250T, PDX265T, PDX275T, PDX440S, PDX450S, U1TW40S, U1TW50S, U1TW60T, U2TW50T, U2TW65T, U4TW40T, U4TW50T, U4TW60T · Green LED, same flash scheme as ei-pv-wv4462 except the 8-x codes (see 8-3 blinks).
- D Series flue damper tankRG1D30T, RG1D40S · Green LED, two-part flash codes like ei-pv-wv4462; 2, 3 and 6-2 flashes point to the damper instead of a pressure switch.
- Ultra Low NOx D Series damper tankURG1D30T, URG1D40S, URG1D40T, URG1D50T, URG2D40S, URG2D50S · Same as ei-damper plus 9-1 and 9-2 codes.
- RG2F high-efficiency tank with a built-in blowerRG2F40S, RG2F50S · Same as ei-pv-wv4462, plus 'one short flash every two seconds' (Sabbath mode).
- Electric tank with the ICON E controlERE240S, ERE240L, ERE250S, ERE250L, ERE250T, ERE255T, ERE340S, ERE340T, ERE350S · LED on the upper control flashes green, amber or red in counts, then is off for 4 seconds.
- AeroTherm heat pump (RE2H50S, RE2H65T, RE2H80T)RE2H50S*-1NCTT, RE2H65T*-1NCTT, RE2H80T*-1NCTT, RE2H50S*-1NCWT, RE2H65T*-1NCWT, RE2H80T*-1NCWT · Fault code (F2, FC, bAd linE...) on the front display; most codes appear only after a set number of fault counts; alarm beeps.
- AeroTherm heat pump, earlier (RE2H50R10, RE2H80R10B)RE2H50R10-1NCWW, RE2H50R10B-1NCWT, RE2H80R10B-1NCWT · Fault code on the front display after the fault count is reached; read faults and counters in Service Mode.
- Infiniti GS and GR tanklessRTGS150N1/X1, RTGS199N1/X1, RTGR150N1/X1, RTGR199N1/X1 · 'Er.xx' flashes on the front display (two-digit number). Hard lock = needs manual reset; soft lock = clears itself.
- Infiniti K and L Series tanklessRTG-K-160N1/X1, RTG-K-199N1/X1, RTG-K-160N2/X2, RTG-K-199N2/X2, RTG-L-160N1/X1, RTG-L-199N1/X1 · Two-character code (letter + digit/letter, e.g. EA, C1) on the display or the outdoor unit’s built-in panel.
- Infiniti RTG-199HE and RTG-199ME (older)RTG-199HE, RTG-199ME · Two-character code on the LCD; some codes flash as status messages.
Which ICON control you have matters for a few codes. Bradford White says ICON 1.0 tanks were built through serial date code “TA” (January 2019) and ICON 2.0 after.
Common questions
Bradford White error code questions
Why is my Bradford White water heater blinking?
The status light on the gas control blinks to show what the heater is doing. On a standard ICON tank with a pilot, a single blink then a pause means the pilot is lit, and 1 blink per second means the burner is on and heating. A set number of blinks, then a 3-second pause, is a code. Count the blinks and find your tank type here.
What does 7 blinks mean on a Bradford White?
On a power vent, power direct vent, damper or RG2F tank, it’s a flammable vapor sensor lockout. On a standard atmospheric tank with a pilot, it means the gas control’s electronics found a fault.
Does 6 blinks mean the same thing on every Bradford White?
No. On standard tanks it’s the leak detector, if one is installed. On Ultra Low NOx URG tanks, the Southern California models, Bradford White’s documents conflict: its service manual and newer quick service guides say it’s the combustion chamber door sensor, but its 2024 owner’s manual says it’s a water leak. We show both in the list of conflicts on this page.
Why is the light on my Bradford White gas control off?
On a standard tank with a pilot, the light is off because the pilot is out. The pilot powers the control, so with no pilot there’s no light and no heat. Relight it by following the lighting instructions on the heater, unless you smell gas. Then leave and call the gas company.
Where this comes from
Sources
Every meaning, cause and step on this page is from Bradford White’s own documents, checked November 13, 2026. Page numbers are the printed page. We left out codes we only found on forums.
- Service Manual: Troubleshooting Guide and Instructions for Service, DEFENDER Safety System, Flammable Vapor Ignition Resistant Water Heaters (atmospheric) Bradford White Corporation · 238-51542-00E · REV 08/22 · Models: RG130T, RG140T, RG150T, RG140S, RG150L, RG150S, RG230T, RG240S, RG240T, RG250H, RG250L, RG250S, RG250T, RG250R, RG255H, RG275H, RG2100H, LG255H, LG275H, LG250H65
- Quick service guide: Atmospheric Vent Water Heaters - ICON Bradford White Corporation · not printed · not printed (same file is posted for prior-NAECA M-series models) · Models: RG series, M series (MI, M4, M1XR, M2XR)
- Installation and Operation Instruction Manual, atmospheric vent gas water heaters (owner’s manual) Bradford White Corporation · 238-51012-00T · REV 01/24 · Models: RG1 / RG2 atmospheric vent residential models
- Service Manual: DV Series Direct Vent Water Heaters Bradford White Corporation · 238-51636-00D · REV 10/20 · Models: RG2DV40S, RG2DV50S, RG2DV50H, LG2DV50H50
- Service Manual: UDV Series Ultra Low NOx Direct Vent Water Heaters Bradford White Corporation · 238-51635-00B · REV 10/18 · Models: URG2DV40S, URG2DV50S, URG2DV50H, ULG2DV50H50
- Service Manual: UDS / UDH Series Ultra Low NOx Direct Vent Water Heaters (archived) Bradford White Corporation · 238-49640-00A · not printed · Models: UDS140S, UDS150S, UDH1504T, UDH165T, UDH175S, UDH50T45FR, UDH65T45FR, UDH75T50FR
- Service Manual: Troubleshooting Guide and Instructions for Service, Defender Safety System (archived, pre-2015 models) Bradford White Corporation · 238-44943-00D · not printed · Models: MI30T, MI40T, MI403S, MI50L, MI504S, M430T, M440T, M4403S, M4503, M1XR403S, M2XR504T, M2XR65T
- Service Manual: ECO-DEFENDER Safety System, Ultra Low NOx Gas Water Heaters Bradford White Corporation · 238-51546-00C · REV 11/20 · Models: URG130T, URG140T, URG150T, URG230T, URG240S, URG240T, URG250L, URG250H, URG250T, URG250S
- Quick service guide: Ultra Low NOx Atmospheric Vent - ICON Bradford White Corporation · not printed · not printed (identical file posted for URG atmospheric, URG power vent, URG damper and archived U-series pages) · Models: URG series, U series
- Installation and Operation Instruction Manual, Ultra Low NOx Gas Water Heater (owner’s manual) Bradford White Corporation · 238-53393-00G · REV 03/24 · Models: URG1 / URG2 atmospheric models
- Service Manual: ECO-DEFENDER Series (archived, pre-2015 Ultra Low NOx models) Bradford White Corporation · 47132A · not printed · Models: U130T, U140T, U1403S, U1503, U150L, U1504S, U430T, U440T, U4403S, U4503, U1XR403S
- Service Manual: PV Series Power Vent Gas Water Heaters Bradford White Corporation · 238-51540-00E · 4/19 · Models: RG1PV40S, RG1PV50S, RG1PV55H, RG2PV40T, RG2PV50H, RG2PV50T, RG2PV75H, RG2PV60T, LG1PV55H78, LG2PV50H65, LG2PV75H76
- Service Manual: PV Series Through-The-Wall Gas Water Heaters - 19 Models Bradford White Corporation · 238-53838-00B · REV 04/22 · Models: RG1PV40S..19, RG1PV50S..19, RG2PV40S..19, RG2PV50S..19, RG2PV50H..19, RG2PV40T..19, RG2PV50T..19, RG2PV60T..19, RG2PV75H..19, LG1PV55H..19, LG2PV50H..19, LG2PV75H..19
- Service Manual: PDV Series Power Direct Vent Gas Water Heaters Bradford White Corporation · 238-51541-00C · 6/21 · Models: RG2PDV40S, RG2PDV50S, RG2PDV50H, RG2PDV75H, LG2PDV50H60, LG2PDV75H80
- Service Manual: UPV Series Ultra Low NOx Through-The-Wall Gas Water Heaters Bradford White Corporation · 238-51548-00D · 12/20 · Models: URG1PV40S, URG1PV50S, URG2PV40T, URG2PV50T, URG2PV50H, ULG2PV50H56
- Service Manual: UPV Series Ultra Low NOx Through-The-Wall Gas Water Heaters - 19 Models Bradford White Corporation · 238-53837-00B · REV 04/22 · Models: URG1PV40S..19, URG1PV50S..19, URG2PV40T..19, URG2PV50T..19, URG2PV50H..19, ULG2PV50H..19
- Quick service guide: Power Vent, Power Direct Vent, & Fan Assisted Water Heaters - ICON Bradford White Corporation · not printed · not printed · Models: RG/LG PV, RG/LG PDV, RG2F
- Installation and Operation Instruction Manual, Power Vent Gas Water Heater (owner’s manual) Bradford White Corporation · 238-54331-00B · REV 03/24 · Models: RG1/RG2 PV 40/50 gal
- Service Manual: Condensing PV Series (eF Series residential) Through-The-Wall Gas Water Heaters Bradford White Corporation · 238-51526-00B · 08/18 · Models: RC2PV50H, LC2PV50H76
- Service Manual: Condensing PDV Series (eF Series) Power Direct Vent Models Bradford White Corporation · 238-53795-00A · REV 11/19 · Models: RC2PDV50H, LC2PDV50H76
- Service Manual: TTW Series Through-The-Wall Gas Water Heaters (archived, pre-2015) Bradford White Corporation · 238-46238A-00A · not printed · Models: M1TW40S, M1TW50S, M1TW60T, M4TW40T, M4TW50T, M4TW60T, M2TW50T, M2TW65T, TW450S65F, TW465S65F
- Service Manual: PDX Series Powered Direct Vent Gas Water Heaters (archived) Bradford White Corporation · 238-49770-00B · not printed · Models: PDX140S, PDX150S, PDX440S, PDX450S, PDX250T, PDX265T, PDX275T, PDX50S60F, PDX65S65F, PDX75S70F
- Service Manual: TTW Eco-Defender Residential Ultra Low NOx Gas Water Heaters (archived) Bradford White Corporation · 238-48509-00A · not printed · Models: U1TW40S, U1TW50S, U1TW60T, U4TW40T, U4TW50T, U4TW60T, U2TW50T, U2TW65T, UTW450S60FR, UTW465S60FR
- Quick service guide: Power Vent and Power Direct Vent Water Heaters (archived pre-2015 page) Bradford White Corporation · not printed · not printed · Models: TTW M1/M2/M4, U-TW, PDX
- Service Manual: Residential D Series (flue damper) Gas Water Heaters Bradford White Corporation · 238-51637-00C · 6/21 · Models: RG1D30T, RG1D40S
- Quick service guide: Damper Equipped Atmospheric Water Heaters - ICON Bradford White Corporation · not printed · not printed · Models: RG D series, URG D series
- Service Manual: Ultra Low NOx Residential D Series Gas Water Heaters Bradford White Corporation · 238-51673-00D · 6/21 · Models: URG1D30T, URG1D40S, URG1D40T, URG1D50T, URG2D40S, URG2D50S
- Service Manual: High EF Atmospheric Vent Gas Water Heater Bradford White Corporation · 238-51617-00C · (10/20) · Models: RG2F40S, RG2F50S
- Service Manual: Residential Electric Water Heaters with ICON E Electronic Control Bradford White Corporation · 238-55036-00A · REV 11/22 · Models: ERE240S, ERE240L, ERE250S, ERE250L, ERE250T, ERE255T, ERE340S, ERE340T, ERE350S
- Quick Start Guide: ICON System Control - ICON E Bradford White Corporation · 238-54399-00B · Rev. 11/22 · Models: ERE residential electric with ICON E
- Heat Pump Water Heater Installation & Operation Instruction Manual (AeroTherm) Bradford White Corporation · 238-52169-00C · ECO 8424, Effective Feb 2022 · Models: RE2H50S-1NCTT, RE2H65T-1NCTT, RE2H80T-1NCTT
- Heat Pump Water Heater Quick Guide (AeroTherm, owner) Bradford White Corporation · 238-52324-00B · 08/18 · Models: RE2H50S-1NCWT, RE2H65T-1NCWT, RE2H80T-1NCWT
- Bradford White Heat Pump Water Heater RE2H50, RE2H80 service quick reference (fault codes, service mode) Bradford White Corporation · 31-75036-1 · 03-15 · Models: RE2H50R10-1NCWW, RE2H50R10B-1NCWT, RE2H80R10B-1NCWT
- Bradford White Heat Pump Water Heater RE2H50R10-1NCWW service quick reference Bradford White Corporation · 238-50804-00A (31-75034) · 03-14 · Models: RE2H50R10-1NCWW
- Installation and Operation Instructions for Infiniti GS Series Gas Condensing Water Heater Bradford White Corporation · 238-54627-00B · Rev 06/24 · Models: RTGS199N1, RTGS199X1, RTGS150N1, RTGS150X1
- Installation and Operation Instructions for Infiniti GR Series Gas Condensing Water Heater with Recirculation Bradford White Corporation · 238-54628-00B · Rev 06/24 · Models: RTGR199N1, RTGR199X1, RTGR150N1, RTGR150X1
- Installation and Operation instructions, Infiniti Tankless K-Series Indoor Model Bradford White Corporation · 6 720 817 984 · 2023/06 · Models: RTG-K-199N1, RTG-K-160N1, RTG-K-199X1, RTG-K-160X1
- Installation and Operation instructions, Infiniti Tankless L-Series (built-in recirculation) Indoor Model Bradford White Corporation · 6 721 827 274 · 2023/06 · Models: RTG-L-199N1, RTG-L-160N1, RTG-L-199X1, RTG-L-160X1
- Installation and Operation instructions, Infiniti Tankless K-Series For Outdoor Installations Only Bradford White Corporation · 6 720 813 642 · 2023/06 · Models: RTG-K-199N2, RTG-K-160N2, RTG-K-199X2, RTG-K-160X2
- Service Manual: Infiniti Series Tankless (Condensing) Gas Water Heater, K and L Series Bradford White Corporation · 238-53328-00B · REV 6/21 · Models: RTG-K-160/199-N1/X1/N2/X2, RTG-L-160/199-N1/X1
- Installation and Operation instructions, Indoor Model RTG 199 HE (Infiniti high efficiency) Bradford White Corporation · 6 720 811 617 / 238-50793-00B · 2016/01 · Models: RTG-199HE
- Installation and Operation instructions, Indoor Model RTG 199 ME (Infiniti mid efficiency) Bradford White Corporation · 6 720 811 615 / 238-50792-00A · 2014/05 · Models: RTG-199ME
- Memo: ICON System name on controls for gas water heaters (with ICON System sell sheet) Bradford White Corporation · ICON20-US-SS1020 (sell sheet) · October 14, 2020 · Models: All Bradford White residential and commercial gas controls
- Bulletin: ICON 1.0 gas valve kits discontinued and replaced with ICON 2.0 gas valve kits Bradford White Corporation · not printed · April 8, 2019 · Models: RG1, RG2, RG275, M2XR75, RG2100, MI100, URG2, URG275, URG2100, LG2, ULG2
- Quick Service Guide / Service Manual Supplement: Atmospheric and Direct Vent Water Heaters - ICON 1.0, Serial Date Code TA (Jan 2019) and Prior Bradford White Corporation · 238-55592-00A · not printed · Models: RG/LG atmospheric, RG2DV/LG2DV direct vent, M-series
- Quick Service Guide / Service Manual Supplement: Atmospheric and Direct Vent Water Heaters - ICON 2.0, Serial Date Code TA (Jan 2019) and Later Bradford White Corporation · 238-55593-00A · not printed · Models: RG/LG atmospheric, RG2DV/LG2DV direct vent
- Quick Service Guide / Service Manual Supplement: Ultra Low NOx Atmospheric & Direct Vent - ICON 1.0, Serial Date Code TA (Jan 2019) and Prior Bradford White Corporation · 238-55594-00A · not printed · Models: URG atmospheric, URG2DV direct vent
- Quick Service Guide / Service Manual Supplement: Ultra Low NOx Atmospheric Vent and Direct Vent - ICON 2.0, Serial Date Code TA (Jan 2019) and Later Bradford White Corporation · 238-55595-00A · not printed · Models: URG atmospheric, URG2DV direct vent
- Quick Service Guide / Service Manual Supplement: TTW / PDX / GXTW (Pre ICON System), Serial date code KA (July 2007 - January 2013) Bradford White Corporation · 238-55596-00A · not printed · Models: TTW, PDX, GXTW
- Quick Service Guide / Service Manual Supplement: Power Vent (PV) Power Direct Vent (PDV) Fan Assist (RG*F) Models With ICON System, Serial date code KA (January 2013 and later) Bradford White Corporation · 238-55597-00A · not printed · Models: RG/LG PV, RG/LG PDV, RG2F
- Quick Service Guide / Service Manual Supplement: Ultra Low NOx Power Vent (PV) & Power Direct Vent (PDV) Models With ICON System, Serial date code KA (January 2013 and later) Bradford White Corporation · 238-55598-00A · not printed · Models: URG PV, URG PDV
- Quick Service Guide / Service Manual Supplement: (U)RG Atmospheric Damper Models With ICON System, Serial date code KA (January 2013 and later) Bradford White Corporation · 238-55599-00A · not printed · Models: RG1D, URG1D, URG2D