No hot water, and nothing else works either
Dave found this in November: a water heater with no gas, and the heater was fine. The valve had tripped. He reset it and got the hot water back.
Read the job →Gas lines · Earthquake valves
When the stove, the water heater and the furnace all quit at once, the earthquake valve at the gas meter has often tripped. A bump can do it. Here’s how to tell, and how to reset it safely.
Dan (left) and Dave. Text a photo of the meter or the spot and Dan will tell you what it looks like.
Before you reset it
If you smell gas anywhere, don’t reset anything. Leave and call SoCalGas at 1-800-427-2200 from outside.
It’s a small round valve on the gas pipe right after the meter, usually with a brand name like Little Firefighter on the cap.
Turn the stove and oven knobs off and close the fireplace key, so no gas flows to an open burner when the gas comes back.
On most valves you unscrew the top cap and pull the stem up slowly until it stays up. Some have a lever instead. Go slowly, and stop if you hear gas rushing.
The water heater, the furnace and a gas fireplace each need their pilot relit. If you’re not comfortable doing it, call Dan or SoCalGas.
What we see
Dave found this in November: a water heater with no gas, and the heater was fine. The valve had tripped. He reset it and got the hot water back.
Read the job →A knock from a ladder, a mower or a kid’s ball can trip a sensitive valve. One mounted crooked trips more easily.
The valve may be worn out or installed off level. We check it and replace it if it’s done.
Some cities require one when a house sells or gets a big remodel. Malibu is one of them. It goes on the pipe right after the meter.
Gas work in Malibu →Then it isn’t the earthquake valve. It’s that appliance or its line.
No hot water →Turn the valve off again by pushing the stem back down, leave and call SoCalGas.
Smell gas →Want one installed, or one that keeps tripping replaced? We do it at the meter, test for leaks and relight everything.
From our jobs
In October Dave put a 3/4-inch Little Firefighter earthquake valve on the gas meter at a house in Los Angeles. It closes the gas automatically in strong shaking, an added safeguard if pipe breaks in a quake. In November he reset a tripped one for a customer with no hot water.
From the jobsite
Common questions
Every gas appliance quits at once, and the stem on top of the valve has dropped down. If only one appliance is out, it’s something else.
Yes, if you don’t smell gas. Turn off open burners first, reset it the way the label says, then relight the pilots. If you smell gas at any point, stop, leave and call SoCalGas.
A hard bump can trip it. So can a valve that is worn out or installed off level. If it keeps happening, the valve needs a look.
Some cities require one when a house sells or gets a large remodel. Malibu is one of them. Even where it isn’t required, it shuts the gas off if a quake breaks a pipe.
A licensed plumber. It goes on the house side of the meter, gets a support bracket, and the system is tested for leaks before the pilots are relit.